• 제목/요약/키워드: Stage-discharge relationship

검색결과 45건 처리시간 0.024초

양산천 수위-유량관계 특성에 관한 연구 (A Study on Characteristics of Stage-discharge Relationship for Yangsan River)

  • 이용희;이상배
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2000년도 춘계학술대회논문집
    • /
    • pp.91-98
    • /
    • 2000
  • Derivation of stage-discharge relationship and characteristics for Yangsan river is presented in this paper. This research has been conducted as the second one after the first trial of 1997. The determination of discharge at a Yangsan river gauging was best made by measuring the flow velocities with a current meter and rod float. The rating curve obtained through 52 stage-discharge measurements on Yangsan river basin in 1999 is represented by Q=15.3540-140.6076H+182.44372$H^2$, which is discovered to be most excellent among other curves in reliability analysis. The capability of the observed stage-discharge data for Yangsan river was tested by HEC-RAS program, and its capability to reproduce discharge was investigated and compared with the computational results. Rating curve stability is determined on the basis of deviations in the stage-discharge relationship, utilization of specific gauge, and absolute differences between sequential stream flow measurements and an analysis residuals. Therefore it seems necessary to research method to obtain rating curve in a rigorous and accurate manner.

  • PDF

양산천 수위-유량관계 특성에 관한 현장관측 분석 (Analysis of Field Observations on Characteristics of Stage-Discharge Relationshiup for Yangsan River)

  • 이용희;이상배
    • 한국항만학회지
    • /
    • 제14권1호
    • /
    • pp.107-114
    • /
    • 2000
  • Derivation of stage-discharge relationship and characteristics for Yangsan river is presented in this paper. This research has been conducted as the second one after the first trial in 1997. The determination of discharge at a Yangsan river gauging was best made by measuring the flow velocities with a current meter and rod float. The rating curve obtained through 52 stage-discharge measurements on Yangsan river basin in 1999 is represented by Q=15.3540-140.6076H+182.44372H$^2$, which is discovered to be most excellent among other curves in reliability analysis. The observed stage-discharge data for Yangsan river was tested by HEC-RAS program, and reproduction of discharge by the induced curve was investigated and compared with the computational results. The rating curve of Yangsan river shows characteristics of Yangsan river more accurately compared with those separated in terms of water levels.

  • PDF

자동계측이 이루어지는 관개용수로에서의 수위-유량관계 분석 (Analysis of Stage-Discharge Relationships in the Irrigation Canal with Auto-Measuring System)

  • 박창언;김진택;오승태
    • 한국농공학회논문집
    • /
    • 제54권1호
    • /
    • pp.109-114
    • /
    • 2012
  • Stage-discharge relationship is applied to convert water level into discharge at the auto-measuring station in many irrigation canals. The stage-discharge curve is very important for reliable application for the agricultural water management system. We made results of discharge measurement at 18 stations in the irrigation canal nearby the Idong reservoir from 2010 to 2011. Stage-discharge relationships for each 18 stations were drawn considering of different hydraulic and geometrical characteristics at each stations. R-squared over 0.91 at each stations show high reliability for application of these relationships.

원뿔형 벤츄리수로의 수리특성 (Hydraulic Characteristics in the Movable Venturi Flume with Circular Cone)

  • 김대근
    • 상하수도학회지
    • /
    • 제27권2호
    • /
    • pp.177-184
    • /
    • 2013
  • This study analyzed the hydraulic characteristics of a venturi flume with a circular cone using a 3-D numerical model which uses RANS(Reynolds-Averaged Navier-Stokes Equation) as the governing equation. The venturi flume with the circular cone efficiently measures the discharge in the low-flow to high-flow range and offers the advantage of accurate discharge measurements in the case of a low flow. With no influence of the tail-water depth, the stage-discharge relationship and the flow behaviors were analyzed to verify the numerical simulation results. Additionally, this study reviewed the effect of the tail-water depth on the flow. The stage-discharge relationship resulting from a numerical simulation in the absence of an effect by the tail-water depth showed a maximum margin of error of 4 % in comparison to the result of a hydraulic experiment. The simulation results reproduced the overall flow behaviors observed in the hydraulic experiment well. The flow starts to become influenced by the tail-water depth when the ratio of the tail-water depth to the total head exceeds approximately 0.7. As the ratio increases, the effect on the flow tends to grow dramatically. As shown in this study, a numerical simulation is effective for identifying the stage-discharge relationship of a venturi flume with various types of venturi bodies, including a venturi flume with a circular cone.

전자파와 수표면 영상을 이용한 산지하천 홍수유량 및 유속 계측 비교 연구 (Comparison of Flood Discharge and Velocity Measurements in a Mountain Stream Using Electromagnetic Wave and Surface Image)

  • 양성기;김동수;류권규;강명수;정우열;이준호;김용석;유호준
    • 한국환경과학회지
    • /
    • 제21권6호
    • /
    • pp.739-747
    • /
    • 2012
  • Due to the difficulties for measuring flood discharge in the dangerous field conditions, conventional instruments with relatively low accuracy such as float still have been widely utilized for the field survey. It is also limited to use simple stage-discharge relationship for assessment of the flood discharge, since the stage-discharge relationship during the flood becomes complicated loop shape. In recent years, various non-intrusive velocity measurement techniques such as electromagnetic wave or surface images have been developed, which is quite adequate for the flood discharge measurements. However, these new non-intrusive techniques have little tested in the flood condition, though they promised efficiency and accuracy. Throughout the field observations, we evaluated the validity of these techniques by comparing discharge and velocity measurements acquired concurrently during the flood in a mountain stream. As a result, the flood discharge measurements between electromagnetic wave and surface image processing techniques showed high positive relationship, but velocities did not matched very well particularly for the high current speed more 3 m/s. Therefore, it should be noted here that special cares are required when the velocity measurements by those two different techniques are used, for instance, for the validation of the numerical models. In addition, authors assured that, for the more accurate flood discharge measurements, velocity observation as well as stage height is strongly necessary owing that the unsteady flow occurs during the flood.

HPG로 산정한 합류부 배수영향 구간의 유량 평가 (An Evaluation of River Discharge Estimates in a Junction with Backwater effect using Interpolated Hydraulic Performance Graph)

  • 김지성;김원
    • 대한토목학회논문집
    • /
    • 제38권6호
    • /
    • pp.831-838
    • /
    • 2018
  • 본 논문에서는 합류부 배수영향을 받는 지점에서 유량을 산정할 수 있는 방법을 제안하였다. 먼저, 최근 2개의 홍수사상에 대한 HEC-RAS 부정류 모의를 수행하여 모형을 보정하였으며, 관심구간 상하류 수위와 유량과의 관계 그래프를 작성하고 크리깅 보간을 수행함으로써 HPG (Hydraulic Performance Graph)를 작성하였다. 대상 홍수기간 동안 HPG와 상하류 연속 수위 자료를 이용하여 구간 유량을 산정하였고, ADVM 같은 자동유량측정 자료와 비교하여 비교적 잘 일치하는 것을 확인하였다. 본 연구결과는 수위-유량 관계곡선의 이력현상이 큰 배수영향 구간에서 유량을 산정하는데 경제적이고 실용적인 방법을 제공할 것이다.

수치모형을 이용한 고리형 수위-유량 관계 분석 (Analysis on Looped Stage-Discharge Relation and Its Simulation using the Numerical Model)

  • 김지성;김원;김동구;김치영
    • 대한토목학회논문집
    • /
    • 제29권1B호
    • /
    • pp.1-9
    • /
    • 2009
  • 본 연구에서는 일반적으로 유량 자료의 생산을 위해 널리 사용되는 수위-유량관계의 고리형 특성 분석과 수치모형에 의해 이를 재현하는 것을 목적으로 하고 있다. 팔당대교 등 3개 지점의 연속적인 수위와 유량자료를 분석한 결과 여러 사상에서 매우 강한 고리형 특성이 발생하는 것을 확인하였다. 이는 기존 단일 수위-유량관계가 많은 오차를 포함할 수 있다는 것을 나타낸다고 할 수 있다. 한강 본류부에 일차원 수치모형을 이용하여 다양한 홍수사상에 적용하고, 그 결과를 실측 수위와 비교하여 검증하였다. 특히 2007년 홍수사상의 경우, 한강대교에 설치된 ADVM을 이용한 연속적인 유량측정 자료와 비교하여 수치모형에 의한 간접유량 산정의 적용성을 검증하였다. 검증된 수치해석 결과로부터 주요지점의 수위-유량관계를 작성한 결과 실측치와 유사한 형태를 구할 수 있었는데, 적절히 보정되고 검증된 수치모형을 이용하면 고리형 특성이 매우 강한 수위-유량관계의 재현이 가능함을 분석하였다. 본 연구 결과는 기존 단일 수위-유량관계의 오차 분석과 수치모형을 이용한 고리형 수위-유량관계 개발에 기여할 수 있을 것으로 판단된다.

수위-유량관계곡선의 자동구간분할을 위한 변동계수 활용기법의 개선 (Improvement of the Method using the Coefficient of Variation for Automatic Multi-segmentation Method of a Rating Curve)

  • 김연수;김정엽;안현욱;정관수
    • 한국수자원학회논문집
    • /
    • 제48권10호
    • /
    • pp.807-816
    • /
    • 2015
  • 일반적으로 수위-유량관계 곡선식은 선형성과 등분산성 가정을 기반으로 구축되지만, 측정단면의 형태, 단면 상 하류의 지형요인 등으로 인하여 영향을 받기 때문에 실질적인 수위 및 유량의 관계는 관계식 구축에 이용되는 가정에 위배된다. 이로 인한 오차를 줄이기 위하여 곡선식을 분할하여 이용하고 있으나, 측정단면의 변화를 고려한 관계자의 주관적인 판단이 구간분할의 주요 근거로 이용되고 있다. 따라서 본 연구에서는 이러한 주관성을 배제하고 관측데이터를 기반으로 객관화된 분할근거를 제시하고자 한다. 곡선식의 구간 분할을 위하여 변동계수를 이용한 기존의 연구를 바탕으로 변동계수가 정규분포를 따르는 것으로 가정하여, 계산된 변동계수가 전 단계에서 계산된 95% 신뢰구간 이내에 존재하지 않는 경우 구간을 분할하였다. 즉, 변동계수를 이용하여 집단 간의 특성을 비교하였으며, 변동계수의 분포를 이용하여 분할을 위한 기준 값을 제시하였다. 방법론의 추정능력 검토를 위하여 가상의 곡선으로부터 생성된 데이터에 제안된 방법론을 적용하였고, 실제유역에 적용성 검토를 위하여 금강에 위치한 무주 및 산계교 수위관측소 지점에 적용하였다. 결과적으로 자동으로 분할된 관계곡선식을 사용하여 추정의 정확도를 높일 수 있을 뿐만 아니라 외삽을 하는 경우 역시 그 정확도를 향상할 수 있음을 확인하였다. 마지막으로 실측값을 활용한 수위-유량관계 곡선식의 구축 시 구간 분할 전 후의 잔차 데이터에 대하여 Shapiro-wilk 정규성 검정을 수행하였으며, 구간분할 후 잔차가 정규성을 갖게 되는 것으로 나타났다.

인공함양 원수확보를 위한 돌망태 보의 저류 및 취수성능에 관한 연구 (Water Storage and Intake Performance of Gabion Weirs during Recharge)

  • 한일영;김규범
    • 지질공학
    • /
    • 제29권4호
    • /
    • pp.393-403
    • /
    • 2019
  • 취수보의 저류성능은 유량과 수심의 관계로 평가될 수 있다. 돌망태 취수보의 유량과 수심의 관계는 채움재의 물리적 특성에 따라 달라진다. 본 연구에서는 인공함양 원수확보를 위한 돌망태 취수보의 저류성능을 평가하는데 활용할 기존의 방류량 산출식들을 검토하였다. 채움재의 물리적 특성을 실험변수들과 관계식으로 표현한 기존의 방류량 산출식은 유량과 수심의 관계를 잘 표현하였다. 또한 채움재의 평균입경은 수심확보와 간접취수에 영향을 미치기 때문에 저류성능 뿐 아니라 취수성능에도 중요한 인자임을 알 수 있었다.