• Title/Summary/Keyword: Squirrel

Search Result 257, Processing Time 0.031 seconds

Numerical Analysis Method of 2-D Dynamic Characteristics of Magnetic Field in Squirrel Cage Induction Motor Considering End-ring (농형회전자의 엔드링(End-ring)을 고려한 유도전동기 자계의 2차원적 동특성 수치해석 방법)

  • 김영중;임달호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.9
    • /
    • pp.1003-1012
    • /
    • 1992
  • This paper presents and analysis method for designing a squirrel cage induction motor, which is aimed at analyzing the dynamic characteristics of magnetic field. This scheme is capable of estimating the effects of slot harmonics due to the rotation of rotor by utilizing Macro-airgap element combination, Voltage source treatment and Time difference algorithm. Furthermore, this strategy presents and approach which effectively compensates for end-ring of rotor. And direct convergence method is applied for considering a magnetic nonlinearity in core. In addition to the precision and the convergence study of algorithm, comparisons with experimental values prove the accuracy of this analysis method.

A Study of the Detection of Broken Bars and the Effect on the Performance in the Squirrel Cage Induction Motor (유도전동기 회전자 불량 진단 및 특성고찰)

  • Jung, Yong-Bae;Kim, Chang-Eob;Jeung, Chang-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.130-132
    • /
    • 1996
  • The squirrel cage rotors for induction motors may have several faults such as broken bars, bad spots in the end ring and abnormal skew caused by improper processing. These faults have bad effect on the performance of the induction motor. In this paper, these fault detection method is proposed, then the effects on the performance of the motor is analyzed using FEM.

  • PDF

A Study on The Broken Rotor Bars in Induction Motor and The Control Characteristics in Inverter

  • Kim K. W.;Lee K. J.;Kwon J. L.;Kim J. K.;Choi K. S.;Lee H. S.;Chang S. G.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.365-368
    • /
    • 2001
  • The advantage of the squirrel cage induction motor is the brush less rotor. This advantage for operation and maintenance turns out to be a disadvantage for the detection of the cage rotor bar and endring defects, which means that the detection of cage faults is due to the measurement and analysis of only the stator input signals. The monitoring task in an inverter drive is complicated mainly because the voltage and current waveforms are nonsinusoidal and the high dv/dt values from fast switching inverterd distort the measurements. In this paper, we are going to discuss the detection method of broken rotor bar of the inverter fed squirrel cage induction motor by the motor current signature analysis(MCSA) and the opening terminal voltage signal analysis.

  • PDF

Characteristics of an Unrecorded Hypoxylon sp. Occurred on the Bed-log of Oak-mushroom in Korea (표고골목에서 발생한 미기록 Hypoxylon sp., 회색버짐버섯(가칭)의 특성)

  • Bak, Won-Chull;Lee, Bong-Hun
    • The Korean Journal of Mycology
    • /
    • v.30 no.2
    • /
    • pp.170-172
    • /
    • 2002
  • An unrecorded Hypoxylon sp. was observed on the bed-log of oak-mushroom (Lentinula edodes) in Korea. The stroma of the fungus was formed on the bed-log (Quercus spp.) damaged by Korean squirrel (Sciurus vulgaris coreae). Perithecia were $200{\sim}400{\mu}m$, and asci containing 8 ascospores were $7{\sim}8{\times}150{\sim}230{\mu}m$ in size. Paraphysis was cylindrical shape, Ascospores were $5{\sim}9{\times}12{\sim}17.5{\mu}m$ in size, pale brown to dark brown, elliptical, and smooth. They have germination cleft and $1{\sim}2$ oil droplets.

Characteristics of an HTS Squirrel Induction Motor (고온초전도 농형유도전동기의 특성)

  • Sim, Jung-Wook;Lee, Kwang-Yeon;Cha, Guee-Soo;Lee, Jik-Wang
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.28-30
    • /
    • 2003
  • The speed-torque characteristics of the squirrel cage induction motor is determined by the rotor resistance. This paper presents the fabrication and test results of an HTS induction motor. Conventional end rings and short bars were replaced with HTS tapes in the rotor. Test result shows that the speeds of the HTS induction motor were the same with synchronous speed and the starting torque was about 19Nm.

  • PDF

Parameter estimation of the inverter-driven squirrel cage induction motor (인버터구동시 농형 유도전동기의 파라메타 추정)

  • Kang, Sei-Hyung;Ahn, Jong-Bo;Kim, Keun-Woong;Kim, Young-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.695-698
    • /
    • 1992
  • When the inverter driven Induction motor is compared with sinusoidal voltage driving, the loss is increased and efficiency in the same output is decreased by the time harmonics in inverter output. These are based on the eddy current on stator and the skin effects of rotor bar current induced from time harmonic. The aim of this paper is to estimate the equivalent circuit parameter of squirrel cage induction motor fed from inverter considering this effects.

  • PDF

Calculation of the Parameter according to the Slip in Squirrel-Cage Induction Motor (Slip에 따른 농형유도전동기의 회로정수 산정)

  • Lee, Su-Jin;Lee, Jeong-Jong;Kim, Sung-Il;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.738_739
    • /
    • 2009
  • This paper describes the calculation of the equivalent circuit parameters according to the slip in squirrel-cage induction motor. Recently, the induction motor is demanded of the various operation condition. In order to acquire the accurate characteristic for the operation condition of the motor, equivalent circuit parameters have to be calculated accurately. So the equivalent circuit parameters are computed by using the finite element method, the reliable characteristic analysis is carried out by application of the parameter to the equivalent circuit analysis. From the analysis result using this combined equivalent circuit and finite element method is compared with the experimental results by a detailed equivalent circuit, the validity of the method is proved.

  • PDF

Calculation of Resistance of Squirrel Cage Induction Motor End Ring using 3-D Finite Element Method (3차원 유한요소법을 이용한 농형유도전동기 단락환의 저항계산)

  • 박민우;이복용;이기석
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.2
    • /
    • pp.71-77
    • /
    • 1996
  • The end-ring may contribute a significant influence to the performance of machine. The induced currents flow through the bars of a cage rotor and complete their closed paths by passing around the end-ring. This dissertation is to describe a method for calculating end-ring resistance of squirrel cage rotor, based on 3-D finite element method(A-$\Phi$). The resistance under consideration of skin effect is calculated by using Joule's loss equation.

  • PDF

A Method for Rotor Vibration Detection of Induction Motor by Air-gap Flux Measurement (공급자속 측정에 의한 유도전동기의 회전자 진동 검출기법)

  • Hwang, Don-Ha;Han, Sang-Bo;Sun, Jong-Ho;Kang, Dong-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.379-384
    • /
    • 2007
  • In this paper, a new method for detecting rotor vibrations in a squirrel-cage induction motor is proposed. The air-gap flux variation analysis was done using search coils inserted in stator slots when rotor vibration conditions occurs. An accurate modelling and analysis of air-gap flux variation in the induction motor are developed using finite-element (FE) software packages, and treasuring the flux are made using search coils. In the FE analysis and experiment, the three-phase squirrel-gage induction motor with 380 [V], 7.5 [kW], 4 Poles, 1,768 [rpm] ratings is used. The simulation and experiment results can be useful for detecting rotor vibration of the induction motors.

  • PDF

The characteristics of deep slot outside rotor type IM (외측 회전형 심구형 유도전동기의 특성)

  • 안병원;박영산;노영오;배철오
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.547-552
    • /
    • 2000
  • This paper presents a developed squirrel cage induction motor for axial flow In. Nearly all of the induction motors for fan consists of two parts, rotor and stator, and the position of rotor is located inside of stator. This construction restricts the air flow rate, otherwise requires bending duct. But developed squirrel cage induction motor for axial flow fan exchanged the position each other. So, we can reduce the weight and size about 30%, and there are no bending duct to locate the fan motor.

  • PDF