• Title/Summary/Keyword: Square tank

Search Result 80, Processing Time 0.03 seconds

Fluid effect on the modal characteristics of a square tank

  • Jhung, Myung Jo;Kang, Sung-Sik
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.1117-1131
    • /
    • 2019
  • Tanks are used extensively in many engineering areas for spent fuel pool structures at nuclear power plants or for water storage tanks in bulk carriers. To ensure the structural integrity of such tanks when under dynamic loads, modal characteristics such as natural frequencies, participation factors and mode shapes should be known. Investigated in this study are the modal characteristics of a square tank by the finite element method. This approach can be used with subsequent dynamic analyses such as a response spectrum analysis or a harmonic analysis. Finite element models are prepared to determine the natural frequencies and mode shapes, which are easy to find the modal characteristics of a fluid-filled square tank. The effects of the fluid contained in the tank and the boundary conditions at top and bottom ends on the modal characteristics are assessed by several finite element analyses.

Comparison of Hydrodynamic Coefficients obtained through Implementation of Diverse Methods in Square Tank

  • Kang, Seunghyun;Yoon, Hyeon Kyu
    • Journal of Navigation and Port Research
    • /
    • v.38 no.1
    • /
    • pp.11-18
    • /
    • 2014
  • To confirm whether the square tank at Changwon National University (CWNU) can be used for estimation of maneuverability, planar motion mechanism (PMM) test and circular motion (CM) test were performed for various conditions. PMM test can be implemented using an XY carriage and a yaw table in the square tank. However, sometimes test section is insufficient for PMM test owing to low length-breadth ratio of the tank. In addition, the speed of a towing carriage is also quite limited. Therefore, it would be useful if PMM test could be effectively performed diagonally, by establishing coupled control logic to drive three servomotors. In addition, Froude number dependency on the estimated hydrodynamic coefficients was checked. Furthermore, CM tests, which cannot be completed in a conventional linear towing tank, were performed, and its results were compared with the results of PMM test. The results of the PMM tests in the diagonal direction were consistent with the results of the test performed in the direction parallel to the sidewall. However, the results of the CM test were greater than those of the PMM test. This tendency was also observed in the results published at Ulsan University.

Wind loads and wind-resistant behaviour of large cylindrical tanks in square-arrangement group. Part 1: Wind tunnel test

  • Liu, Qing;Zhao, Yang;Cai, Shuqi;Dong, Shilin
    • Wind and Structures
    • /
    • v.31 no.6
    • /
    • pp.483-493
    • /
    • 2020
  • Large cylindrical floating-roof tanks, constructed as oil containers, are usually distributed regularly in open area and easily exposed to severe wind loads. However, wind pressures around these grouped squat tanks appear to have not been clearly given in design codes or thoroughly studied in existing researches. This paper conducts a detailed investigation on wind loads on the external wall of a four-tank group in square arrangement. To achieve that, wind tunnel tests are carried out on both empty and full tank groups, considering various wind angles and spacing. Results show that 3 regions in elevation can be identified on the tank shell according to the circumferential wind pressure distribution. The upper 2 regions cover a relatively small portion of the shell where excessive negative pressures are spotted, setting an alarm to the design of the top angle and stiffening rings. By comparing results on grouped tanks to those on an isolated tank, grouping effects concerning wind angle, tank position in group and spacing are discussed. Deviations on pressure distributions that will compromise structural safety are outlined, including the increase of negative pressures, the shift of maximum pressure locations as well as the change of positive pressure range. And, several potentially unfavourable wind pressure distributions are selected for further analyses.

Analysis for Water tank model simulation of parallel plate electrodes (병렬판상전극의 수조모델 시뮬레이션 해석)

  • Koh, Hee-Seog;Kim, Sung-Sam;Lee, Chung-Sik;Choi, Jong-Kyu;Ryoo, Hee-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.280-282
    • /
    • 2003
  • In this paper we tried to analyze through the water tank model to solve these kinds of problems about the square plate earth electrode using general facilities with being compared with the theory formula announced before. The square plate earth electrode that haven't investigated so far is analyzed by being based on laid rod electrode. And the each kind of calculation model was investigated with the experiment of water tank. An experiment of the vertical square Plate electrode about laying depth in the center of the surface of the water has already done with the practical models that have different forms of electrodes.

  • PDF

Wind loads and wind-resistant behaviour of large cylindrical tanks in square-arrangement group. Part 2: CFD simulation and finite element analysis

  • Liu, Qing;Zhao, Yang;Cai, Shuqi;Dong, Shilin
    • Wind and Structures
    • /
    • v.31 no.6
    • /
    • pp.495-508
    • /
    • 2020
  • To investigate the structural behaviour of grouped tanks under wind loads, 2 problems need to be figured out, wind pressures on tank shells and critical loads of the shell under these pressure distribution patterns. Following the wind tunnel tests described in the companion paper, this paper firstly seeks to obtain wind loads on the external wall in a squarely-arranged cylindrical tank group by numerical simulation, considering various layouts. The outcomes demonstrate that the numerical method can provide similar results on wind pressures and better insights on grouping effects through extracted streamlines. Then, geometrically nonlinear analyses are performed using several selected potentially unfavourable wind pressure distributions. It is found that the critical load is controlled by limit point buckling when the tank is empty while excessive deformations when the tank is full. In particular, significant reductions of wind resistance are found on grouped full tanks compared to the isolated tank, considering both serviceability and ultimate limit state, which should receive special attention if the tank is expected to resist severe wind loads with the increase of liquid level.

Earthquake-Induced Wall Pressure Response Analysis of a Square Steel Liquid Storage Tank (지진하중을 받는 정사각형 강재 액체저장탱크의 벽면 압력 응답 해석)

  • Yun, Jang Hyeok;Kang, Tae Won;Yang, Hyunik;Jeon, Jong-Su
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.5
    • /
    • pp.261-269
    • /
    • 2018
  • This study examines earthquake-induced sloshing effects on liquid storage tanks using computation fluid dynamics. To achieve this goal, this study selects an existing square steel tank tested by Seismic Simulation Test Center at Pusan National University as a case study. The model validation was firstly performed through the comparison of shaking table test data and simulated results for the water tank subjected to a harmonic excitation. For a realistic estimation of the wall pressure response of the water tank, three recorded earthquakes with similar peak ground acceleration are applied:1940 El Centro earthquake, 2016 Gyeongju earthquake, and 2017 Pohang earthquake. Wall pressures monitored during the dynamic analyses are examined and compared for different earthquake motions and monitoring points, using power spectrum density. Finally, the maximum dynamic pressure for three earthquakes is compared with the design pressure calculated from a seismic design code. Results indicated that the maximum pressure from the El Centro earthquake exceeds the design pressure although its peak ground acceleration is less than 0.4 g, which is the design acceleration. On the other hand, the maximum pressure due to two Korean earthquakes does not reach the design pressure. Thus, engineers should not consider only the peak ground acceleration when determining the design pressure of water tanks.

Experiment for the Relation Between Arrangement,Numbers and Pumping Rates of Well (관정의 배열수 및 양수량의 상호관계에 관한 실험)

  • 권무남
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.11 no.3
    • /
    • pp.1707-1718
    • /
    • 1969
  • The purpose of this experiment is to determine the relations between numbers, arrangements and pumping rates of wells. In this experiment, well pipes were vertically set up in an artificial water-bearing sand layer of homogeneous quality. Wells were arranged in different ways and their number was varied in order to observe the variation of pumping rates. Sands were filled in a square tank, $183cm{\times}91.5cm{\times}91.5cm$ so as to secure a water-bearing layer. Water was constantly supplied from a supply tank located at an end of the tank. The number of well pipes was varied from one to four. Well pipes were connected by a horizontal header pipes were connected by a horizontal header pipe located above them and one pump was used. Pumping rates were measured, when they were arranged in longitudinal and lateral directions, They were also arranged in a square and triangle. The main results thus obtained are presented as follows: (1) When well pipes are laid out in a longitudinal line, i. e., in a flow direction, the ratios of pumping rates of one-pipe well and wells 2-, 3- and 4- pipe t, are 1.903, 2.506 and 2.66, respectively. (2) When well pipes are laid out in a lateral line, i.e., in a perpendicular direction to flow, the same ratios as (1) are 1.912, 2.527 and 2.88. (3) When four pipes are laid out in a square and three pipes are laid out in a triangle, pumping rates are deereased, Comparing with the cases when pipes are laid out in a straight line.

  • PDF

Evaluation of the Tank Model Optimized Parameter for Watershed Modeling (유역 유출량 추정을 위한 TANK 모형의 매개변수 최적화에 따른 적용성 평가)

  • Kim, Kye Ung;Song, Jung Hun;Ahn, Jihyun;Park, Jihoon;Jun, Sang Min;Song, Inhong;Kang, Moon Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.4
    • /
    • pp.9-19
    • /
    • 2014
  • The objective of this study was to evaluate of the Tank model in simulating runoff discharge from rural watershed in comparison to the SWAT (Soil and Water Assessment Tool) model. The model parameters of SWAT was calibrated by the shuffled complex evolution-university Arizona (SCE-UA) method while Tank model was calibrated by genetic algorithm (GA) and validated. Four dam watersheds were selected as the study areas. Hydrological data of the Water Management Information System (WAMIS) and geological data were used as an input data for the model simulation. Runoff data were used for the model calibration and validation. The determination coefficient ($R^2$), root mean square error (RMSE), Nash-Sutcliffe efficiency index (NSE) were used to evaluate the model performances. The result indicated that both SWAT model and Tank model simulated runoff reasonably during calibration and validation period. For annual runoff, the Tank model tended to overestimate, especially for small runoff (< 0.2 mm) whereas SWAT model underestimate runoff as compared to observed data. The statistics indicated that the Tank model simulated runoff more accurately than the SWAT model. Therefore the Tank model could be a good tool for runoff simulation considering its ease of use.

Development of a Wave Absorbing System Using an Inclined Punching Plate (경사형 타공판을 이용한 소파장치 개발)

  • 조일형;홍석원
    • Journal of Ocean Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • In this paper, the performance of a wave absorbing system using an inclined punching plate, was investigated. Using the multi-domain boundary element method (BEM), the reflection coefficients of an inclined punching plate were tested with various design parameters, such as inclined angle, porosity, and wave frequencies. To confirm the numerical solutions, the systematic model test was conducted at 2-D tank and square tank. The numerical results were in good agreement with the experimental results within the entire frequency range. It was found that an inclined punching plate had an excellent wave absorbing efficiency, compared to a horizontal one. Also, the optimal range of an inclined angle had an excellent wave absorbing efficiency, compared to a horizontal one the optimal range of the inclined angle is 10°<β<20°. The developed wave absorber was installed at KRISO's square basin, and is working effectively for various model tests.

Analysis and Suggestion of Estimation Equation for Sedimentation in Square Manholes with Straight Path (사각형 중간맨홀에서의 유사 퇴적 분석 및 산정식 제안)

  • Kim, Jung-Soo;Song Ju-Il;Rim Chang-Soo;Yoon, Sei-Eui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.177-189
    • /
    • 2012
  • Sediment load deposited in sewers and manholes reduces not only the capacity of pipes but also the efficiency of the whole sewer system. This causes the inundations of the low places and overflows at manholes, Moreover, sulfides and bad odor can occur due to deposited sediment with organic loads in manholes. Movements of sediment load in manholes are complicated depending on manhole size, location, inside structure, sediment load type, and time. Therefore, it is necessary to understand the movements of sediment load in manholes by experiments. In this study, experiments were implemented by a square manhole with straight path to measure deposited sedimentation quantity. The experimental apparatus was consisted of a high water tank, an upstream tank, test pipes, a sediment supplier, a manhole, and a downstream tank to measure the experimental discharge. The quantity of deposited sediment load was measured by different conditions, such as the inflow condition of sediment(continuous and certain period), the amount of inflow sediment, discharge, and the type of sediment. Jumoonjin sand(S=2.63, D50=0.55mm), general sand(GS, S=2.65, D50=1.83mm) and anthracite (S=1.45, D50=0.80mm) were employed for the experiment. The velocities in inflow pipe were 0.45 m/s, 0.67 m/s, and 0.9 m/s. Sediment load movement and sedimentation quantity in manhole were influenced by many factors such as velocity, shear stress, viscosity, amount of sediment, sediment size, and specific gravity. Suggested regression equations can estimated the quantity of deposited sediment in the straight path square manholes. The connoted equations that were evaluated through the experimental study have velocity range from 0.45 to 0.9m/sec. The study results illustrates that appropriation of design velocity ragne between 1.0 and 2.0m/sec could implement to maintain and manage manholes.