• Title/Summary/Keyword: Square pulse

Search Result 259, Processing Time 0.215 seconds

가중 쳐프 신호를 사용한 초음파 고조파 영상 기법

  • 김동열;이종철;권성재;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.61-72
    • /
    • 2002
  • In this parer, a new harmonic imaging technique is Proposed and evaluated experimentally. In the Proposed method. a weighted chirp signal with a hanning window is transmitted. The RF samples obtained on each array element are individually compressed by correlating with the reference signal defined as the 2nd harmonic component($2f_0$) of a transmitted chirp signal generated in a square-law system. The correlator output will then consist of the compressed version of the $2f_0$ component generated in tissue and the crosscorrelation sequence of the fundamental($f_0$) and 2f$_{0}$components. The Proposed method uses the compressed $2f_0$ component to form an image. for which the crosscorrelation term should be suppressed below at least -50dB. The Proposed method has two process, 2f$_{0}$-correlation and $2f_0$-correlation(PI) . $2f_0$-correlation can successfully eliminate the $f_0$ component with a single transmit-receive events and therefore is more efficient than the conventional Pulse inversion method in terms of the frame rate. 2i)-correlation(Pl) Performs pulse compression after applying pulse inversion method for the 2nd harmonic image with high resolution and SNR. Another advantage of the proposed method is that the SNR of 2nd harmonic imaging can be improved without limitation by increasing the duration of the chirp signal. The proposed method was verified through both the computer simulations and actual experiments .ts .

Change of RIII Reflex of Primary and Secondary Hyperalgesia Site by High Voltage Pulsed Current (고전압맥동전류에 의한 일차 및 이차통각과민대의 RIII 반사의 변화)

  • Kim, Su-Hyon;Choi, Sug-Ju;Lee, Jung-Woo;Jeong, Jin-Gyu;Kim, Tae-Youl;Kim, Gye-Yeop
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.4 no.1
    • /
    • pp.1-12
    • /
    • 2006
  • This study conducted RIII reflex measurement to examine degree of pain depending on polarity of high voltage pulsed current of primary and secondary hyperalgesia site in hyperalgesia rat by local thermal injury. Hind paw which was injury site was taken as primary hyperalgeisa site, sole which was injury adjacent site was taken as secondary hyperalgesia site, and mechanical pain threshold, thermal pain threshold and root mean square of RIII reflex were measured. This study was conducted with control group I of hyperalgesia rat at hind paw by thermal injury and experimental groups divided into cathodal high voltage treatment group II, anodal high voltage treatment group III and alternate high voltage treatment group IV, applied active electrode of high voltage pulsed current to hind paw directly, placed reference electrode on the sole of injury adjacent site and applied pulse frequency. It measured RIII reflex and obtained the following results: Root mean square of RIII reflex at primary hyperalgeisa site was significantly reduced in group II after 2 days of hyperalgesia. Group II showed significant decrease after 5 and 6 days of hyperalgesia. Root mean square of RIII reflex at secondary hyperalgesia site showed significant reduction in group II after 6 days of hyperalgesia. Consequently it was found that application of high voltage pulsed current of hyperalgesia site reduced RIII reflex at primary hyperalgeisa site and secondary hyperalgesia site by electrical stimuli. Effects by polarity of high voltage pulsed current showed the greatest reduction of pain threshold when cathodal active electrode was used.

  • PDF

Development of a Low frequency Operating Electronic Ballast for Fish Attracting Lamps (저주파 구동형 집어등용 전자식 안정기 개발)

  • Kil Gyung-suk;Kim Il-kwon;Song Jae-yong;Han Ju-seop;Shin Gwang-chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.5
    • /
    • pp.1052-1058
    • /
    • 2005
  • This paper dealt with the design and fabrication of a low frequency electronic ballast for ruh attracting lamps. The proposed electronic ballast was composed of a full-wave rectifier, a step don converter operated as a constant power controled current source, an inverter operated by 130 Hz square wave, and an ignition circuit. An acoustic resonance phenomenon of discharge lamps could be eliminated by application of 130 Hz square wave. Also, a circuit of high voltage pulse generation for lamp ignition was added to the ballast. From the experimental results, voltage and current of the lamp operated by the electronic ballast were estimated 132.5 V and 7.6 A, respectively. and the power consumption was about 1,000 W. The weight of the ballast, which is one of important advantages, was reduced to one-fifth of conventional magnetic ballasts.

Radioassay of Multiple Beta-Labeled Mixtures using Least-Square Method (최소자승법을 이용한 다수 베타 방출 핵종 혼합물의 방사능 분석)

  • Seon, Kwang-Il;Nam, Uk-Won;Kong, Kyoung-Nam;Kim, Chang-Kyu;Lee, Dong-Myung;Lee, Sang-Kook
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.375-384
    • /
    • 2001
  • It is possible to count and perform quench correction on two ${\beta}$ -label samples so long as the maximum ${\beta}$-energies are sufficiently different. However, when 4he conventional technique is applied to the radioassay of a mixture of more than three nuclides, the reliability of the activities determined is considerably reduced, resulting from the large overlapping of liquid scintillation pulse height distributions of each nuclide. A technique that allows the activities of multiple ${\beta}$-labeled samples to be radioassayed was proposed by using the least square method. The technique was applied to mixture samples of $^3H,\;^{14}C,\;^{36}Cl$, and $^{90}Sr$. The analytical values were in good agreement with the reference values within 7% relative error.

  • PDF

Effects of Panel Temperature on the Discharge Characteristics of Micro Discharge Cells

  • Shim, Kyung-Ryeol;Park, Chung-Hoo;Lee, Ho-Jun
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.5
    • /
    • pp.215-219
    • /
    • 2004
  • The effects of ambient temperature on the discharge characteristics of Ne-Xe based micro discharge cells for ac-PDP (plasma display panel) have been studied. In ramp voltage driving, which is generally used as a reset method of PDP, two dissimilar modes of strong and weak discharge were found. As the interval between the former sustaining discharge and ramp voltage discharge becomes greater, the probability of a strong discharge increases. This suggests that a sufficient number of priming particles is necessary for initiating weak mode (Townsend discharge). It was discovered that under higher ambient temperatures, weak discharge occurs more frequently. The discharge time lag observed in square pulse driving of single cells becomes surprisingly smaller under higher ambient temperatures for the constant gas number density condition.

Driving Characteristic Analysis of Brushless DC Motor Considering PWM Mode (PWM 모드를 고려한 브러시리스 DC 전동기의 구동 특성 해석)

  • Shin Hyun-Hun;Lee Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.98-107
    • /
    • 2005
  • Brushless DC motor(BLDCM) can be driven by 120[^{\circ}]$ square wave voltage and use PWM pulse patterns in two-phase feeding scheme to control the speed of the motor. This Paper introduces four PWM modes used BLDCM control system, and analyzes their different influences on the motor performances using a time-stepped voltage source finite element method. To verify the proposed computational method, we built the prototype motor for electrical power steering(EPS) and compared the predicted and the measured back EMF and phase current.

Error Performance of UWB-MIMO system according to channel detection methods (UWB-MIMO 시스템에서 채널 검파 방식에 따른 성능 비교분석)

  • Kang, Yun-Jeong;Baek, Sun-Young;Kim, Sang-Choon
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.113-114
    • /
    • 2008
  • In this paper, binary pulse-position modulation (2PPM) time-hoping (TH) ultra-wideband (UWB) system is applied to multiple input multiple output (MIMO) system using vertical bell lab layered space-time (V-BLAST) structure to achieve high-data-rate communications. This UWB-MIMO system and its receivers are analyzed, and its BER performances are evaluated. In the receiver, various MIMO detection algorithms such as zero-forcing (ZF), ZF-ordered successive interference cancellation (OSIC), minimum-mean-square-error (MMSE), MMSE-OSIC and maximum likelihood (ML) are comparatively studied.

  • PDF

Effects of Electrode Shape and Electrode Distance on the Properties of Xe Plasma Flat Fluorescent Lamp (LCD Backlight용 FFL(Flat Fluorescent Lamp)의 발광특성에 미치는 전극 형상 및 전극간 거리의 영향)

  • Kang, Jong-Hyeon;Lee, Yang-Kyu;Heo, Sung-Taek;Kim, Sang-Woo;Lee, Dong-Gu;Oh, Myung-Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.12
    • /
    • pp.1105-1110
    • /
    • 2008
  • In this study, plasma flat fluorescent lamps (FFLs) having two electrode type structures of surface discharge was fabricated by screen printing and were characterized using spectra-radiometer and square pulse power supply. Two types of FFLs (cross-type and line-type electrode structure) were compared with variation of discharge shape and electrode distance.

Emission Characteristics of Flat Fluorescent Lamp for LCD Backlight Using Inert Gas Mixture

  • Heo, Sung-Taek;Lee, Yang-Kyu;Kang, Jong-Hyun;Yoon, Seung-Il;Oh, Myung-Hoon;Lee, Dong-Gu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1522-1525
    • /
    • 2007
  • In this study, flat fluorescent lamps (FFLs) having surface discharge structures was fabricated by screen printing technique and were studied using spectraradiometer and square pulse power supply. Two types of FFLs having different shapes of electrodes (crosstype and line-type structure) were compared with variation of discharge shape and mixed gas ratio.

  • PDF

A Study on the SCR Frequency Converter With a Rotating Distributor (회전접촉자를 사용한 SCR 주파수 변환기에 관한 연구)

  • Chung Yon Tack
    • 전기의세계
    • /
    • v.24 no.1
    • /
    • pp.43-53
    • /
    • 1975
  • This paper describes a converter, which combines SCR bridge type rectifier circuit with a rotating distributor. This type of converter produces an adjustable low frequency output of three phase or single phase, from three phase or single phase power source. Output-waveforms of this converter are multi-pulse in three phase output, and square wave in single phase output. Problems about the operation of static switches, a commutation and output-waveforms are investigated, and experimental results verify that frequency can be adjusted satisfactorily from zero to 20 (Hz) and the expected output-waveforms are obtained without sparking on the distributor under various loading conditions. This converter can be utilized to low speed control of A.C. motors, and other lowfrequency loads.

  • PDF