• 제목/요약/키워드: Spread Rate

Search Result 998, Processing Time 0.026 seconds

Experimental analysis of very long range spread spectrum underwater acoustic communication using vertical sensor array (수직 배열 센서를 이용한 초장거리 대역확산 수중음향통신의 실험 분석)

  • Youn, Chang-hyun;Ra, Hyung-in;An, Jeong-ha;Kim, Ki-man;Kim, In-soo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.2
    • /
    • pp.150-158
    • /
    • 2022
  • This paper presents the results of a sea trial for very long range spread spectrum underwater acoustic communication conducted in the East Sea in September 2021. Signals were collected through 8 vertical sensors, and the range between the transmitter and receiver was about 160 km. 30 bps Multi-Code Spread Spectrum (MCSS) method and 100 bps Chirp Spread Spectrum method were used for the transmitting signal generation. The results show that when the channel coding technique was not used in a single channel, the uncoded bit error rate was high, but when the Equal Gain Combining (EGC) diversity technique was used after frame synchronization in each receiving channel, the uncoded bit error rate was reduced to 0.1 or less.

A Framework to Determine the Loan Rate of the Government Loan Program based on Rationales of the Government Loan Program (고객만족수준과 고객만족을 위한 지출 및 재무적 성과의 관계에 관한 연구)

  • Im, Sin-Suk;Lee, Ho-Gap
    • 한국벤처창업학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.327-352
    • /
    • 2007
  • The loan rate of the government loan program offered by the Small Business Corporation(SBC) can be determined as a sum of three factors such as a reference interest rate, a policy aim spread, and a credit risk spread. However the loan rate has been lower than the loan rate in the banking sector. The profit has continually run in the red figures and hence the stability the fund managed by the SBC has been damaged. Even though a policy aim spread could be emphasized, the stability and profitability of the fund should be prioritized. This means that the loan rate of the SBC should be determined such that the loss might not be occurred. This requires the policy aim spread to change from relatively large negative to near zero.

  • PDF

Assessment of Grid Sensitivity in the FDS Field Model to Simulate the Flame Propagation of an Electric Cable Fire (케이블 화재의 화염전파 해석을 위한 FDS 모델의 격자민감도 평가)

  • Kim, Sung-Chan;Lee, Seong-Hyuk
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.30-35
    • /
    • 2008
  • The present study has been conducted to examine the effect of grid resolution on the predicted results for electric cable fire using pyrolysis model in FDS(Fire Dynamics Simulator, version 5). The grid independent test for different grid resolutions has been performed for a PE coating cable and the grid resolution is defined by the non-dimensional characteristic length of fire and mean grid size. The calculated maximum heat release rate and mean flame spread rate were almost constant for higher grid resolution of 20${\sim}$25 and the computing time for the grid resolution takes approximately 20hours to solve flame propagation with pyrolysis model. The geometrical simplification of a electric cable dose not greatly affect on the maximum heat release rate and flame spread rate and the rectangular approximation of cable shape gives acceptable result comparing with the round cable with stepwise grid.

Fuzzy Test of Hypotheses by Rate of Internal Division (내분비에 의한 퍼지 가설 검정)

  • Kang, Man-Ki;Jung, Ji-Young
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.425-428
    • /
    • 2012
  • We propose some properties for fuzzy hypotheses testing by the principle of the rate of internal division on delta-levels. By the rate of internal division, we show that the acceptance and rejection degree for fuzzy the fuzzy hypotheses and reduce the spread of the fuzzy variance with average of the center and left or right spread of fuzzy number data.

Experimental Study on Downwardly Spreading Flame over Inclined Polyethylene-insulated Electrical Wire with Applied AC Electric Fields (교류전기장이 인가된 폴리에틸렌으로 피복된 기울어진 전선을 통해 하향으로 전파하는 화염에 대한 실험적 연구)

  • Lim, Seung Jae;Park, Jeong;Kim, Min Kuk;Chung, Suk Ho;Osamu, Fujita
    • Journal of the Korean Society of Combustion
    • /
    • v.19 no.4
    • /
    • pp.1-7
    • /
    • 2014
  • An experimental study on downwardly spreading flame over slanted electrical wire, which is insulated by Polyethylene (PE), was conducted with applied AC electric fields. The result showed that the flame spread rate decreased initially with increase in inclination angle of wire and then became nearly constant. The flame shape was modified significantly with applied AC electric field due to the effect of ionic wind. Such a variation in flame spread rate could be explained by a thermal balance mechanism, depending on flame shape and slanted direction of flame. Extinction of the spreading flame was not related to angle of inclination, and was described well by a functional dependency upon the frequency and voltage at extinction.

A Chirp Rate Allocation Scheme for Multiple Access Interference Reduction in Chirp Spread Spectrum Systems (처프 확산 대역 시스템에서 다중 접속 간섭의 감소를 위한 처프율 할당 기법)

  • Kim, Kwang-Yul;Lee, Seung-Woo;Kim, Yong-Sin;Lee, Jae-Seang;Kim, Jin-Young;Shin, Yoan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.11
    • /
    • pp.1420-1422
    • /
    • 2016
  • In order to guarantee the multiuser transmission performance of a chirp spread spectrum system, the cross-correlation coefficient (CCC) among multiple users should be carefully considered. In this paper, we propose a chirp rate allocation scheme for reducing the multiple access interference based on the cross-correlation coefficient. The simulation results show that the proposed scheme can improve the multiple access interference performance.

A Closed-Form BER Expression for Overlap-Based CSS System Design (오버랩 기반 CSS 시스템 설계를 위한 닫힌꼴 비트 오류율 표현)

  • Yoon, Tae-Ung;Lee, Young-Yoon;Lee, Myung-Soo;Song, Iick-Ho;Yoon, Seok-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.4C
    • /
    • pp.469-475
    • /
    • 2009
  • Overlap is one of the techniques for increasing bit rate in chirp spread spectrum (CSS). More overlaps can offer higher data throughput; however, they may cause more intersymbol interference (ISI) at the same time, resulting in serious bit error rate (BER) performance degradation. Thus, the number of overlaps should be decided according to the required BER performance. In this paper, we derive a closed form expression for BER of the overlap-based CSS system, exploiting the approximated Gaussian Q function. The derived BER expression includes the number of overlaps as a parameter, and thus, would be very useful in determining the number of overlaps for a specified BER. The numerical results demonstrate that the BER derived in a closed form closely agrees with the simulated BER.

EFFECT OF TOP END CONDITION OF FUEL BED CONTAINER ON DOWNWARD SMOLDER SPREAD

  • Sato, Kenji;Sakai, Yasuhiro
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.146-153
    • /
    • 1997
  • An experimental study was performed of natural-convection downward smolder spread across a sawdust bed peripherally enclosed with an insulating container, to examine the effect of the open- ing condition at the top end on downward smolder spread. Experiments were conducted by using relatively coarse sawdust and 25-cm-long cylindrical container The variations of temperature profiles along the bed axis with time were determined far different opening conditions and were com-pared with those in smolder spread from open top to open bottom. It was shown that the smolder zone initiated from open top toward closed bottom penetrates the bed with keeping high peak temperature like the case of open top to open bottom spread, although mean spread rate is smaller. This indicates that the downward smolder zone can be sustained stably if sufficient air or oxygen Is supplied from the back of it by natural convection even if upward draft entering from the bottom of the bed is absent. When the top end was partially closed by mounting a cover after stable smolder spread had begun from open top toward open bottom, the temperature at the peak decreased more than 200 K and the smolder zone became to spread with thickening residue. In this case, the shape of temperature profiles continuously changed or decayed until end-effect at the open bottom end enhanced the reaction. The temperature at the shrunk peak, free from the end-effect, was almost identical with the temperature at the exothermic oxidative-degradation zone in smolder spread from open top to open bottom. from these results, it can be inferred for natural-convection downward smolder spread that the oxidation reaction of the char is very sensitive to the oxygen supply by natural convection in the space above the smolder zone, and that the top end opening condition strongly alters the completeness of reactions, structure, and behavior of the smolder zone.

  • PDF

Comparison a Forest Fire Spread variation according to weather condition change (기후조건 변화에 따른 산불확산 변화 비교)

  • Lee, Si-Young;Park, Houng-Sek
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.490-494
    • /
    • 2008
  • We simulated a forest fire which was occurred in Yangyang area on 2005 and compared a results between two different weather conditions(real weather condition and mean weather condition since 1968) using FARSITE, which is a forest fire spread simulator for preventing and predicting fire in USDA. And, we researched a problem in the transition for introducing, so we serve the basic method for prevention and attacking fire. In the result, severe weather condition on 2005 effected a forest fire behavior. The rate of spread under real weather condition was about 4 times faster than mean weather condition. Damaged area was about 10 time than mean weather condition. Therefore, Climate change will make a more sever fire season. As we will encounter to need for accurate prediction in near future, it will be necessary to predict a forest fire linked with future wether and fuel condition.

  • PDF

The FEC decoder design of the spread spectrum basis which utilizes the VHDL (VHDL을 이용한 대역확산 시스템 기반의 FEC 디코더 설계)

  • 이재성;정운용;강병권;김선형
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2003.06a
    • /
    • pp.300-303
    • /
    • 2003
  • In this paper, a baseband module of the spread spectrum system with FPGA is designed. A spread spectrum system spreads the signal bandwidth necessary for information transmission. We focused on the design of FEC decoder, especially the convolutional code fo constraint length K=3, rate R=l/2, is designed. For the VHDL design the Xilinx Foundation 3.1 is used. As results, a spread spectrum modem with convolutional coding is designed and we have plan to apply this modem to short distances wireless communication.

  • PDF