• Title/Summary/Keyword: Spraying rate

Search Result 240, Processing Time 0.027 seconds

The influence of spraying conditions to the coating layer properties of Fe-Cr-Ni-Mo-Si-B alloy using the HVOF (HVOF를 이용한 Fe-Cr-Ni-Mo-Si-B계 고성능 합금 용사층의 특성에 미치는 용사조건의 영향)

  • 권기봉;조대형;장영권;백영남
    • Journal of the Korean institute of surface engineering
    • /
    • v.35 no.1
    • /
    • pp.5-10
    • /
    • 2002
  • This study was performed to investigate the influence of spraying condition to the coating layer properties of Fe-Cr-Ni-Mo-Si-B alloy using the HVOF. The investigations, such as thickness measurement, surface roughness, hardness, friction coefficient, resistance of corrosion were carried out. Matrix is prepared by gritting and coating layer is made of Fe-Cr-Ni-Mo-Si-B alloy powder using HVOF. Alumina gritting layers are superior to steel gritting layers. The less spaying distance, the more coating layer properties confirmed. The optimum spraying condition, in this study, was proved as 13inch spraying distance with feed rate 350rpm (78g/min).

Formulation of Erythromycin Enteric-coated Pellets (에리스로마이신 장용성 펠렛의 제제 설계)

  • 이승우;박은석;지상철
    • YAKHAK HOEJI
    • /
    • v.39 no.6
    • /
    • pp.593-599
    • /
    • 1995
  • Erythromycin was formulated as enteric-coated pellets in order to reduce degradation in stomach and gastromtestmal irritation, and to maximize the absorption in intestine followmg its oral administration. Core pellets were prepared using fluid-bed granulator with two different methods (powder layering and solvent spraying) and enteric-coated with two different coating polymers (HPMCP and Eudragit E30D). Physical characteristics md dissolution rates of core pellets and enteric-coated pellets were evaluated to optimize the formulation. Powder layering method resulted in shorter initial dissolution time than solvent spraying method, but physicochmical properties of the product were worse than solvent spraying method with respect to hardness, ftiability and density. The dissolution rate of the drug was increased with the addition of surfactants, showing concentration-dependence. The scanning electron microscopic observation of pellets revealed significant differences on the surface appearances prepared with solvent spraying method. The core pellet made with powder layering method had crystals on the surface, which resulted in poor physical properties of the pellets. The dissolution profiles of erythromycin pellets coated with HPMCP or Eudragit L30D were close to that of commercially available erythromycin enteric-coated product.

  • PDF

INDUCTION PLASMA DEPOSITION TECHNOLOGY FOR NUCLEAR FUEL FABRICATION

  • I. H. Jung;K. K. Bae;Lee, J. W.;Kim, T. K.;M. S. Yang
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.216-221
    • /
    • 1998
  • A study on induction plasma deposition with ceramic materials, yttria-stabilized-zirconia ZrO$_2$-Y$_2$O$_3$ (m.p 264O $^{\circ}C$), was conducted with a view developing a new method for nuclear fuel fabrication Before making dense pellets more than 96%TD., the spraying condition was optimized through the process parameters, such as chamber pressure, plasma plate power powder spraying distance, sheath gas composition, probe position, particle size and powders different morphology. The results with a 5mm thick deposit on rectangular planar graphite substrates showed a 97.11% theoretical density when the sheath gas flow rate was Ar/H$_2$120/20 l/min, probe position 8cm, particle size -75 ${\mu}{\textrm}{m}$ and spraying distance 22cm by AMDRY146 powder. The degree of influence of the main effects on density were powder morphology. particle size, sheath gas composition, plate power and spraying distance, in that order. Among the two parameter interactions, the sheath gas composition and chamber pressure affects density greatly. By using the multi-pellets mold wheel type, the pellet density did not exceed 94%T.D., owing to the spraying angle.

  • PDF

Development of a Control System for Uniform Application Rate on a Self-Propelled Boom Sprayer (붐방제기의 균일량 살포를 위한 제어시스템 개발)

  • 조성인;정창주;이동훈;이중용
    • Journal of Biosystems Engineering
    • /
    • v.21 no.4
    • /
    • pp.406-413
    • /
    • 1996
  • A control system for a self-propelled boom sprayer to spray at uniform application rate was developed and evaluated. The ground speed of the sprayer was converted into voltage. The voltage was used as an input signal. Output signal was current of a servo motor, that controlled application pressure of the sprayer with a feedback control system. Spraying was executed at the pressure of 20~55 psi and the speed of 0.640~0.696 km/hr and 1.040-1.131 km/hr. Although the pressure and the speed of sprayer were changed continuously, application rate was tried to keep a nearly constant amount of 666.67 L/ha. This result showed that the developed control system for uniform application rate was adoptable for the self-propelled sprayer.

  • PDF

Optimization of HVOF Spray Parameters for $Cr_3C_2 - 7wt%NiCr$ Coating Powder by Experimental Design Method (실험계획법에 의한 $Cr_3C_2 - 7wt%NiCr$ 용사분말의 HVOF 용사변수 최적화)

  • 김병희;서동수
    • Journal of Welding and Joining
    • /
    • v.15 no.1
    • /
    • pp.125-134
    • /
    • 1997
  • This study was conducted by L9 orthogonal array to obtain optimum spray parameters for This study was conducted by L9 orthogonal array to obtain optimum spray parameters for $Cr_3C_2 - 7wt%$(80wt%Ni-20wt%Cr) coating powder. The factors were hydrogen flow rate, oxygen flow rate, gun-to-work distance, powder feed rate. And evaluation methods for the coating were surface roughness, oxygen concentration, micro-hardness, pore size and distribution, low angle ($30^{\circ}$) erosion rate, and microstructure of coating. The optimum HVOF spray conditions were proved as follows : hydroen flow rate ; 681 SLPM, oxygen flow rate ; 215 SLPM $H^2/O^2 ratio= 3.16), gun-to-work distance ; 22cm, powder feed rate; 25g/min. The hardness (Hv300) was 1147 and the erosion rate ($30^{\circ}$degree) was $3.16\times10^{-4}$g/g. It is believed that the optimized spray conditions can be improved the wear-resistance and anti-erosion characteristics of the coating.

  • PDF

A Study on Droplet Charging of an High Voltage Spraying System (고전압 분사시스템의 액적 하전 특성연구)

  • Son, Seung-Woo;Yoo, Kyoung-Hoon;Kim, Yoon-Shin
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.893-898
    • /
    • 2003
  • An experiment was conducted to characterize water droplet charging performance of an electrostatic spraying nozzle for an electrostatic wet scrubber. Charge-to-mass ratios, the nozzle currents divided by the mass flow rate of water were obtained with respect to the applied voltage to the ring-electrode for 2 different flow conditions. It was shown that the charge-to-mass ratio increased in proportion to the applied voltage and tended to saturate at a certain higher voltage.

  • PDF

Variation of Mechanical Properties with Powder Spraying Conditions in Mo and Co Alloy (Mo 및 Co계 분말의 용사조건에 따른 기계적 특성 변화)

  • 하국현
    • Journal of Powder Materials
    • /
    • v.2 no.3
    • /
    • pp.201-207
    • /
    • 1995
  • In general, the characteristics of plasma spray coating are strongly dependent on process conditions. In this paper, Mo and Co alloy coating layers were made by plasma spraying with different spray parameters and characterized using X-ray diffraction, scanning electron microscopy(SEM), hardnass test, and wear test. It was found that the coating characteristics were mainly affected by phase composition of the powder, spray distance, arc current, and gas flow rate.

  • PDF

Development of Accelerator Control System for Wet Shotcrete Spraying Equipment (습식 숏크리트 뿜칠 장비의 급결제 유량 제어 시스템 개발)

  • Tae-Ho, Kang;Soo-Ho, Chang;Soon-Wook, Choi;Jin-Tae, Kim;Bong-Gyu, Kim;Chulho, Lee
    • Tunnel and Underground Space
    • /
    • v.32 no.6
    • /
    • pp.353-362
    • /
    • 2022
  • The wet shotcrete refers to a method in which all materials are mixed and then supplied to the spraying device, compressed air is added to the nozzle, and the spraying speed is improved to spray on the target surface. In order to reproduce the amount of shotcrete used in the wet method in the field and the situation at the laboratory scale, it is essential to control the discharge amount of the equipment. In this study, in order to increase the reproducibility of field conditions at the laboratory scale, a flow control system for shotcrete mortar spraying equipment was developed and applied to the equipment. To verify the developed equipment, a discharge control test using water and mortar was performed. In the developed control system, the discharge was smoothly controlled according to the user input value for the mono pump, but the discharge was not properly controlled according to the input value for the screw pump because of a reducer. When a speed reducer is attached, it is necessary to adjust the operation rate of the screw pump close to the target flow rate by increasing the operation rate of the screw pump while lowering the operation rate of the mono pump.

Thermal Analysis Comparison of IMO with USCG Design Condition for the INGC During the Cool-down Period (급냉각기간에서 IMO설계조건과 USCG 설계조건에 대한 LMGC 화물탱크의 열해석 비교)

  • Lee, Jung-Hye
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1390-1397
    • /
    • 2004
  • This study is concerned with the thermal analysis during the cool-down period of 135,000㎥ class GT-96 membrane type LNG carrier under IMO and USCG design condition. During the cool-down period, the spraying rate for the NG cooling decreases as the temperature of NG falls down from -4$0^{\circ}C$ to -l3$0^{\circ}C$, and the spraying rate for the cooling of the insulation wall increases as the temperature gradient of the insulation wall is large. It was confirmed that there existed the largest temperature decrease at the first barrier and the first insulation, which are among the insulation wall, especially in the top side of the insulation wall under IMO and USCG design condition. Also, as the NG temperature distribution is fixed, the outer temperature condition under the design condition has influence on the temperature variation at the insulation. By the 3-D numerical calculation about the cargo tank and the cofferdam during the cool-down period, the temperature variation in hulls and insulations is precisely predicted under IMO and USCG design condition. From the comparison between two conditions; IMO design condition shows more severe temperature gradient than USCG design condition, therefore, it provides the conservative estimation of the BOG.

Thermal Analysis for the GT-96 Membrane Type LNGC during the Cool-down Period (GT-96 멤브레인형 LNGC의 급냉기간에서의 열해석)

  • Lee, Jung-Hye;Choi, Hyun-Kue;Choi, Soon-Ho;Oh, Cheol;Kim, Myoung-Hwan;Kim, Kyung-Kun
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1346-1351
    • /
    • 2004
  • This study is concerned with the thermal analysis during the cool-down period of 135,000 $m^3$ class GT-96 membrane type LNG carrier under IMO design condition. The cool-down is performed to cool the insulation wall and the natural gas in cargo tank for six hours to avoid the thermal shock at the start of loading of $-163^{\circ}C$ LNG. During the cool-down period, the spraying rate for the NG cooling decreases as the temperature of NG falls clown from $-40^{\circ}C$ to $-130^{\circ}C$ and the spraying rate for the insulation wall cooling increases as the temperature gradient of the insulation wall is large. It was confirmed that there existed the largest temperature decrease at the 1 st barrier and 1st insulation, which are among the insulation wall, especially in the top side of the insulation wall. By the 3-D numerical calculation about the cargo tank and the cofferdam during the cool-down period, the temperature variation in hulls and insulations is precisely predicted.

  • PDF