• Title/Summary/Keyword: Spray distance

Search Result 282, Processing Time 0.021 seconds

Film Boiling Heat Transfer Model of Spray Cooling Focusing on Rebound Motion of Droplets (액적의 리바운드 모션에 주목한 분무냉각 막 비등 열전달 모델)

  • Kim Yeung Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.2 s.233
    • /
    • pp.287-293
    • /
    • 2005
  • In the present study, to determine the flow rate of droplets supplied to heat transfer surface after (j-1)th rebound, $D_X[j{\ge}2]^{\ast}$, it was assumed that the rebound droplets are distributed according to the Gaussian distribution from 0 to L, in which the flight distance L is determined by maximum flight distance $L_{max}$. We also assumed that $L_{max}$ is dependent on the air flow velocity and mean size of droplets. The local heat flux of a dilute spray in high temperature region was predicted using the newly evaluated $D_X[j{\ge}2]^{\ast}$. In addition, the predicted results by the present model were compared with the existing experimental data.

Study on Minimum Heat Flux Point in Spray Cooling of Hot Plate (고온 평판의 분무냉각에 있어서 MHF점에 관한 연구)

  • 김영찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.974-981
    • /
    • 2001
  • In this study, the minimum heat flux conditions are experimentally investigated for the spray cooling of hot plate. The hot plates are cooled down from the initial temperature of about$ 900^{\circ}C$, and the local heat flux and surface temperatures are calculated from the measured temperature-time history. The results show that the minimum heat flux point temperatures increase linearly resulting from the propagation of wetting front with the increase of the distance from the stagnation point of spray flow. However, in the wall region, the minimum heat flux point temperature becomes independent of the distance. Also, the velocity of wetting front increases with the increase of the droplet flow rate.

  • PDF

Intermittent Atomization Characteristics of Multi-Hole and Single-Hole Diesel Nozzle

  • Lee, Jeekuen;Kang, Shin-Jae;Park, Byungjoon
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.12
    • /
    • pp.1693-1701
    • /
    • 2002
  • The intermittent spray characteristics of a multi-hole and a single-hole diesel nozzle were experimentally investigated. The hole number of the multi-hole nozzle was 5, and the hole diameter of the 5-hole and the single-hole nozzle was the same as d$\_$n/=0.32 ㎜ with the constant hole length to diameter ratio(l$\_$n//d$\_$n/=2.81). The droplet diameters of the spray, including the time-resolved droplet diameter, SMD (Sauter mean diameter) and AMD (arithmetic mean diameter) , injected intermittently from the two nozzles into the still ambient were measured by using a 2-D PDPA (phase Doppler particle analyzer). Through the time-resolved evolutions of the droplet diameter, it was found that the structure of the multi-hole and the single-hole nozzle spray consisted of the three main parts : (a) the leading edge affected by surrounding air. and composed of small droplets; (b) the central part surrounded by the leading edge and mixing flow region and scarcely affected by the resistance of air, (c) the trailing edge formed by the passage of the central part. The SMD decreases gradually with the increase in the radial distance, and the constant value is obtained at the outer region of the radial distance (normalized by hole diameter) of 7-8 and 6 for the 5-hole and single-hole nozzle, respectively. The SMD along the centerline of the spray decrease shapely with the increase in the axial distance after showing the maximum value near the nozzle tip. The SMD remains the constant value near the axial distance(normalized by hole diameter) of 150 and 180 for the 5-hole and the single-hole nozzle, respectively.

A Study on the Development of Emulsified Fuel Supplier and Spray Characteristics of Domestic Petroleum Boiler (가정용 보일러의 유화연료 공급장치 개발 및 분무 특성에 관한 연구)

  • Yoon, M.K.;Kim, Y.K.;Ryu, J.Y.
    • Journal of ILASS-Korea
    • /
    • v.3 no.4
    • /
    • pp.8-15
    • /
    • 1998
  • The spray characteristics of emulsified fuel of W/O type has been experimentally investigated. The mixture of light oil and water by using ultrasonic energy adding system is used as the emulsified fuel. The SMD of sprayed droplet of emulsified fuel is measured by using the particle size analyzer. Major parameters of the present experimental study are the volume fraction of water in emulsified fuel, $0\sim30%$ by 5%, injection pressure, $10kg_f/cm^2\sim18kg_f/cm^2$ by $2kg_f/cm^2$, and the measurement distance, $10\sim100mm$, between injection nozzle tip and analyzer beam. Compared with light oil, the SMD of emulsified fuel is larger gradually by increasing the volume fraction of water in emulsified fuel, heightening injection pressure and increasing the spray distance. Also, In considering the fact that the pattern of drop size distribution of emulsified fuel is alike that of light oil, the real time spray in coincidence with making emulsified fuel by adding ultrasonic energy can stabilize spray pattern without modificating the injection system used by now.

  • PDF

Development of A Boom Sprayer for Effective Pest-and-Disease Control on Densed Paddy Stems (수도(水稻) 기부(基部) 방제용(防除用) 붐-형(型) 주간(株間) 살포(撒布) 장치(裝置) 개발(開發)에 관(關)한 연구(硏究))

  • Chung, Chang Joo;Chang, Young Chang
    • Journal of Biosystems Engineering
    • /
    • v.10 no.1
    • /
    • pp.13-23
    • /
    • 1985
  • Spraying method from the paddy-field levee is known to give insufficient penetration of the spray droplets to the rice stem of the densely grown plants, which is generally encountered at the last stage of rice growth. This study was intended to investigate the spraying system to solve this existing problem. As an approach, it was attempted to develop the boom-with-nozzle, between-the-row application system. Several types of nozzles and their different arrangements in the boom were tested in the field to measure the penetration-reaching distance and the uniformity of spray droplet distribution. The results of the study are summarized as follows: 1. Field experiments by the spraying method from the paddy-field levee showed to have practically no penetration of the spray droplets to the portion of the plant stem with the normal flow volume generally applied and thus need for improving present spraying method. 2. It was found that, considering both the uniformity of the spray droplet distribution and performance rate, the most efficient type of nozzle in the between-the-row boom-type spraying system was one that has core-insert hollow-cone with some clearance between the cone and tip. 3. When tested by applying the spraying method of between-the-row, the nozzle pressure did not affect the uniformity of spray droplet distribution. However, the nozzle pressure had a positive effect on the penetrating-reaching distance of the facing side of the rice stem and did not affect much on that of the opposite face of the stem. It was also found that the maximum pressure to affect the penetration-reaching distance was about $10kg/cm^2$. 4. The uniformity of the spray droplet distribution in the between-the-row system was greatly affected by the height and orientation of the nozzles in the boom. Based on experimental work for the different type of the boom-with-nozzle arrangements, it is recommended that the position of nozzle is set at about 0.45 m above the ground and two nozzles in the boom are oriented to be faced with each other with some angle such that the droplet stream from the nozzle would not directly face with each other.

  • PDF

Behaviour of Ultra-High Pressure Diesel Spray on Electronic Hydraulic FuelInjection System (전자유압식 분사계에 의한 초고압 디젤분무의 거동에 관한 연구)

  • 장세호;김준효;안수길
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.2
    • /
    • pp.137-146
    • /
    • 1996
  • Behaviour of ultra-high pressure diesel spray and its structure in a constant-volume pressure chamber were studied with injection pressure ranging from 35 to 110MPa. Sprays were observed by using the back illumination scattering method and righ angle scattering method. The spray process mechanism were investigated with both photographs. As a result, the spray angle and air entrainment angle was larger as injection pressure and back pressure increase. It becomes clear that mean air-fuel ratio is increased by increasing the injection pressure.

  • PDF

Coverage Distribution of Blasted Droplets by an Orchard Sprayer (과수방제기 살포입자의 도포율 분포특성)

  • 구영모;김상헌;신범수
    • Journal of Biosystems Engineering
    • /
    • v.26 no.4
    • /
    • pp.355-362
    • /
    • 2001
  • Uniform application of agri-chemicals will improve orchard pest management. An air-blast(orchard) sprayer designed for vineyards has been used: however, few research on the uniformity and coverage of the sprays has been reported. Distributions of spray coverage were measured with artificial targets and analyzed to enhance the efficiency of spray application. A structure was built to place water sensitive papers, sampling spray droplets blasted from the orchard sprayer. The sampling cards were collected from five directions at three distances (2.5, 3.0 and 3.5m) for two fan speeds (2,075 and 3,031 rpm), and analyzed using an image analysis system. The distribution of the coverage percent area did not follow the wind velocity pattern. The coverage by the low fan speed was more uniform and higher than that by the higher fan speed. The coverage percent area decreased with an increase of distance. The distribution of droplet density was similar to that of coverage. However, the coverage contribution by smaller droplets became more significant as the distance increased. The upward blasting distance was limited within 3m, but the limit to the ground level was expanded the distance more than 3.5m because of the concentrated droplets.

  • PDF

Experimental and Numerical Investigation on DME Spray Characteristics as a Function of Injection Timing in a High Pressure Diesel Injector (고압 분사 인젝터의 분사 시기에 따른 DME 분무특성에 관한 실험 및 해석적 연구)

  • Kim, Hyung-Jun;Park, Su-Han;Lee, Chang-Sik
    • Journal of ILASS-Korea
    • /
    • v.14 no.3
    • /
    • pp.109-116
    • /
    • 2009
  • The purpose of this study is the experimental and numerical investigation on the DME spray characteristics in the combustion chamber according to the injection timing in a common-rail injection system. The visualization system consisted of the high speed camera with metal halide lamp was used for analyzing the spray characteristics such as spray development processes and the spray tip penetration in the free and in-cylinder spray under various ambient pressure. In order to observe the spray characteristics as a function of injection timing, the piston head shape of re-entrant type was created and the fuel injected into the chamber according to various distance between nozzle tip and piston wall in consideration of injection timing. Also, the spray and evaporation characteristics in the cylinder was calculated by using KlVA-3V code for simulating spray development process and spray tip penetration under real engine conditions. It was revealed that the high ambient pressure of 3 MPa was led to delay the spray development and evaporation of DME spray. In addition, injected sprays after BTDC 20 degrees entered the bowl region and the spray at the BTDC 30 degrees was divided into two regions. In the calculated results, the liquefied spray tip penetration and fuel evaporation were shorter and more increased as the injection timing was retarded, respectively.

  • PDF

Study on the Spray Characteristics of Liquid/Liquid Pintle Injector by Opening Distance (액체/액체 핀틀 분사기의 개도에 따른 분무특성 연구)

  • Yoon, Wonjae;Ahn, Jonghyeon;Ahn, Kyubok;Yoon, Hosung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.3
    • /
    • pp.14-25
    • /
    • 2021
  • An experimental study was conducted on the spray characteristics of the pintle injector by opening distance. The discharge coefficient of the pintle injector was investigated and the spray angle was measured by taking the spray image by test conditions. As a result of the measurement of the discharge coefficient, it was confirmed that the change in the discharge coefficient of the outer injector was not significant over the experimental conditions, but the change in the discharge coefficient of the inner injector was decreased as the flow rate increased. Measurement of the spray angle showed that the change in the spray angle was not significant in the conditions under which the spray was fully developed, but the spray was not fully developed at low flow rates. This confirmed the possibility of thrust control using the pintle injector.

Comparision of Spray Angles of Pintle-Type Gasoline Injector with Different Measuring Methods (측정방법에 따른 핀틀형 가솔린 인젝터의 분무각 비교)

  • Kim, K.J.;Rhim, J.H.;No, S.Y.;Moon, B.S.;Kim, J.Y.;Kang, K.G.
    • Journal of ILASS-Korea
    • /
    • v.4 no.4
    • /
    • pp.9-16
    • /
    • 1999
  • Spray angle, a parameter which is most commonly used to evaluate. spray distribution, is important because it affects the axial and radial distribution of the fuel. Spray angles were measured and compared for the pintle-type gasoline fuel injector with n-heptane as a test fuel with the three different measuring techniques, i.e. digital image processing, shadowgraphy and spray patternator, respectively. Fuel was injected with the injection pressures of 0.2-0.35MPa into the room temperature and atmospheric pressure environment. In digital image processing method, the transmittance level greatly influences the spray angle with the axial distance from the injector. From the experimental results by the shadowgraphy technique, it is obvious that the spray angle vary during the injection period. The results of spray angle from the spray patternator show that there exist the different spray angles in the different areas. The spray angles increase with the increase in the injection pressure for the three measurement techniques considered in this study. The spray angle is widely different, especially in the near region from the injector, according to the measurement techniques used in this experimental work.

  • PDF