• Title/Summary/Keyword: Spray Nozzle

Search Result 674, Processing Time 0.028 seconds

Influence of Ultra-high Injection Pressure and Nozzle Hole Diameter on Diesel Flow and Spray Characteristics under Evaporating Condition (증발 조건에서 초고압 분사와 노즐 홀 직경이 디젤 유량 및 분무 특성에 미치는 영향에 대한 연구)

  • Cho, Wonkyu;Park, Youngsoo;Bae, Choongsik;Yu, Jun;Kim, Youngho
    • Journal of ILASS-Korea
    • /
    • v.20 no.1
    • /
    • pp.43-52
    • /
    • 2015
  • Experimental study was conducted to investigate the effects of ultra-high injection pressure and nozzle hole diameter on diesel flow and spray characteristics. Electronically controlled ultra-high pressure fuel injection system was made to supply the fuel of ultra-high pressure consistently. Three injection pressures, 80, 160, and 250MPa were applied. Four type of injectors with identical eight nozzle holes were used. The four injectors have nozzle hole diameters of 115, 105, 95, and $85{\mu}m$ respectively. Injection quantity and rate were measured to investigate flow characteristics according to injection pressures and nozzle hole diameters. Mie-scattering and shadowgraph were performed to visualize liquid and vapor phases of diesel spray in a constant volume combustion chamber (CVCC). Ambient conditions of high pressure and high temperature in a diesel engine were simulated by using CVCC.

A Study on Nozzle Flow and Spray Characteristics of Piezo Injector for Next Generation High Response Injection (차세대 고응답 분사용 피에조 인젝터의 노즐유동 및 분무특성에 관한 연구)

  • Lee Jin-Wook;Min Kyoung-Doug
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.6 s.249
    • /
    • pp.553-559
    • /
    • 2006
  • Most diesel injector, which is currently used in high-pressure common rail fuel injection system of diesel engine, is driven by the solenoid coil energy for its needle movement. The main disadvantage of this solenoid-driven injector is a high power consumption, high power loss through solenoid coil and relatively fixed needle response's problem. In this study, a prototype piezo-driven injector, as a new injector mechanism driven by piezoelectric energy based on the concept of inverse piezo-electric effect, has been designed and fabricated to know the effect of piezo-driven injection processes on the diesel spray structure and internal nozzle flow. Firstly we investigated the spray characteristics in a constant volume chamber pressurized by nitrogen gas using the back diffusion light illumination method for high-speed temporal photography and also analyzed the inside nozzle flow by a fully transient simulation with cavitation model using VOF(volume of fraction) method. The numerical calculation has been performed to simulate the cavitating flow of 3-dimensional real size single hole nozzle along the injection duration. Results were compared between a conventional solenoid-driven injector and piezo-driven injector, both equipped with the same micro-sac multi-hole injection nozzle. The experimental results show that the piezo-driven injector has short injection delay and a faster spray development and produces higher injection velocity than the solenoid-driven injector. And the predicted simulation results with the degree of cavitation's generation inside nozzle for faster needle response In a piezo-driven injector were reflected to spray development in agreement with the experimental spray images.

An Experimental Study of Spray Nozzle Desalination Facility (담수화 설비 스프레이 노즐에 대한 실험적 연구)

  • SHIN HYUN-KYOUNG;JOO HYUN-TAE;PARK MIN-HO;PARK KYOUNG-MIN;KIM JIN-YOUNG;LIM JIN-YOUNG
    • Journal of Ocean Engineering and Technology
    • /
    • v.20 no.1 s.68
    • /
    • pp.26-31
    • /
    • 2006
  • Experimental research was undertaken to develop a domestic spray nozzle used on equipment for desalination. First, we made a test set-up in order to confirm nozzle efficiency of spray and distribution under different pressure conditions. Then, we found a maximum spray condition after verifying reliability of this facility. An optimum arrangement of the nozzle, based on the test result, was made using CATIA V5 and EXCEL.

Study on K-factor for temperature variation of working fluid in spray nozzle with orifice (오리피스형 분사노즐에서 작동유체의 온도변화에 따른 K-factor에 관한 연구)

  • Bae, K.Y.;Chung, H.T.;Kim, C.H.;Kim, H.B.
    • Journal of Power System Engineering
    • /
    • v.12 no.3
    • /
    • pp.12-18
    • /
    • 2008
  • In the present study, the numerical simulation has been performed to investigate K-factor for temperature variation of working fluid in spray nozzle with orifice. The commercial CFD software, Fluent with the proper modeling was applied for analyzing the internal of the spray nozzle. Numerical result for K-factor at $20^{\circ}C$ agrees with the experimental result that it applied n=0.5 within about 7% error. The pressure drop inside nozzle is showed 20% passing swirler, 70% in the region between the outlet of swirler and the orifice and 10% at the outlet of orifice. As the operating pressure is increased, K-factor is decreased by effect of flow resistance at it's inlet before pass swirler. The temperature increase of working fluid reduced the flow rate according to reducing of density, and average 1.23% decrease is showed in the present research.

  • PDF

Ultrasonic Spray Nozzle System with Piezoelectric Device for Chemicals Dispersion (압전체를 이용한 약품 분사용 초음파 분사 노즐 시스템)

  • 고재석;김용현;김형수;조순행;최승철
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.4
    • /
    • pp.65-71
    • /
    • 2003
  • A new type of ultrasonic spray nozzle was fabricated employing a piezoelectric device. The spray nozzle was designed to disperse chemicals in a water treatment mixing tank. The piezoelectric properties in ultrasonic spray nozzles were optimized to improve the dispersion of chemicals. The piezoelectrics were packaged in an aluminum case with silicone resin for the aqueous solution proof packaging. Chemicals were dispersed with high efficiency and the chemicals consumption was reduced by the ultrasonic fine particle spraying. The concentration of Escherichia coli in mixing tank was decreased remarkably using ultrasonic spray nozzle dispersion compared to the conventional methods.

  • PDF

An Experimental Study on Nozzle Spray Characteristics for the Design of Heat Exchangers of a Nano-Silver HVAC System (은나노 공조시스템의 열교환기 설계를 위한 노즐의 분무특성 실험)

  • Heo, Ju-Yeong;Kang, Byung-Ha
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.534-537
    • /
    • 2008
  • Growing attention has been given to sterilizing and antibacterial effects of nano-silver, recently. Nano-silver solution can be applied to the heat exchanger in an air conditioner to prevent bad smell or bacteria. The present study is directed at the nozzle spray characteristics over a heat exchanger. This problem is of particular interest in the design of a nano-silver HVAC system. The effects of nozzle position and flow rate on the spray area over a horizontal surface have been investigated for various nozzles. The results obtained indicate that spray area is increased as the height of spray position is increased or mass flow rate is increased. The wetted area over a practical heat exchanger is also studied at a given nozzle height. It is found that the wetted area is gradually increased with an increase in the flow rate. However, the effect of flow rate on the wetted area is a little affected by flow rate in the range of too much flow rate. It is also found that the wetted area is decreased as the inclination angle of a heat exchanger is increased.

  • PDF

Thermal Characteristics of Foams and Discharge of Fire-Protection Foam Spray Nozzle (폼 분무 노즐 방사 분포 및 폼의 열적 특성 연구)

  • Kim, Hong-Sik;Kim, Youn-Jea
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.151-158
    • /
    • 2005
  • A characteristic of discharge for a foam spray nozzle with various parameters was investigated. The discharge patterns from a fire foam spray nozzle are important to evenly spray over a maximum possible floor area. Two parameters of a foam spray nozzle were chosen, and compared with those from the standard one. Also, in order to evaluate the performance of discharged foam agents used to protect structures from heat and fire damages, the thermal characteristics of fire-protection foams were experimentally investigated. A simple repeatable test for fire-protection foams subjected to fire radiation was developed. This test involves foam generation equipment, a fire source for heat generation, and data acquisition techniques. Results show that the bubble size of foam is increased by large inside diameter of orifice or closed air hole, but phenomenon of discharge angle and expansion ratio is opposite. For the case of the open air hole, liquid film of a circular cone discharges with formation, growth, split and fine grain. In case of the closed air hole, a pillar of foam solution discharges with that. Though the temperature gradient in the foam increases with increased foam expansion ratio. it is not change with increased intensity of heat flux.

Spray Characteristics of the Rotating Fuel Nozzle with Orifice Geometry (회전연료노즐 형상변경에 따른 분무특성)

  • Jang, Seong-Ho;Choi, Hyun-Kyung;Lee, Dong-Hun;You, Gyung-Won;Choi, Seong-Man
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.240-243
    • /
    • 2008
  • An experimental study was conducted to understand spray characteristics of rotating fuel nozzle by using high speed rotational system. The experimental apparatus consist of a fuel injection system, high speed rotational system, and acrylic case. The test is performed with several diameters and number of injection orifices. Spray characteristics such as droplet size and velocity are measured by PDPA(Phase Doppler Particle Analyzer). From the test results, we could understand the spray characteristics of rotating fuel nozzle with orifice number and diameter.

  • PDF

Ultrasonic Spray Nozzle System with Piezoelectric Device for Chemicals Dispersion (압전체를 이용한 약품 분사용 초음파 분사노즐 시스템)

  • Koh Jea Seok;Kim Yong Hyun;Choi Seung Chul
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2003.11a
    • /
    • pp.278-281
    • /
    • 2003
  • A new type of ultrasonic spray nozzle was fabricated with piezoelectric devices. The spray nozzle was designed for the chemicals dispersion in the water purification bath. The piezoelectric properties in ultrasonic spray nozzles were optimized for the better dispersion of chemicals for purification process. Ultrasonic spray nozzle was packaged in metal case with silicone resin for the water proof application.

  • PDF

An Experimental Study on Breakup Mode of Epoxy Paint Discharging from a Fan Spray Nozzle (선형분무노즐로부터 분무되는 에폭시계 도료의 분열기구에 대한 실험적 연구)

  • Kang, S.I.;Lee, S.Y.;An, S.M.;Ryu, S.U.
    • Journal of ILASS-Korea
    • /
    • v.12 no.3
    • /
    • pp.138-145
    • /
    • 2007
  • In the present work, the breakup mechanism of highly viscous epoxy paints discharged from a fan spray nozzle was examined experimentally. The paints tested were non-Newtonian fluids, composed of epoxy resin, solid particles and other additives. The paint spray discharged from the nozzle was visualized and recorded using a digital camera with back illumination. Due to presence of the solid particles, perforation of liquid sheet was observed in most cases, even at low-Reynolds number conditions (Re < 15,000) where the aerodynamic-wave breakup mode is used to be dominant for pure liquids. However, with the increase of the particle concentration, the sheet became longer and the thickness at breakup became thinner to some extent. This is because, with higher concentration of solid particles, the stabilizing effect by the viscosity increase predominates over the destabilizing effect by perforation.

  • PDF