• Title/Summary/Keyword: Spot test

Search Result 630, Processing Time 0.028 seconds

A Study on Behavior of Fracture and Stress Distribution in Spot Welds (점熔接材 의 破壞擧動 과 應力分布)

  • 송삼홍;김부동
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.3
    • /
    • pp.224-231
    • /
    • 1984
  • Having found by means of a tension-shear test an optimal spot welding condition under which the maximum weld strength is to be brought forth, this study made an examination of behavior of fracture concerned with behavior of stress distribution, observed around the nugget periphery of the specimens prepared under the optimal conditions, with one point spot welded mild steel sheets. The resultant findings are as follows: (1)There remarkably exists an optimal spot welding condition to indicate the maximum weld strength, and fracture of the specimens spot welded under that condition occurs outside the nugget boundary. (2)An experiment on the basis of a photoelastic model reveals that the maximum stress is distributed along the center line of the steel plate width but occurs on the region corresponding to heat affected zone of spot welds. (3)Heat affected zone of spot welds consists of coarse grains with considerably low micro Vickers hardness value and of fine grains of high micro Vickers hardness value, and in this unbalanced structure weak region are represented in coarse grain region, where fracture is initiated and continues its propagation.

The Impact of Index Future Introduction on Spot Market Returns and Trading Volume: Evidence from Ho Chi Minh Stock Exchange

  • NGUYEN, Anh Thi Kim;TRUONG, Loc Dong
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.8
    • /
    • pp.51-59
    • /
    • 2020
  • The objective of this study is to enrich the literature by investigating the impact of introduction of index future trading on spot market returns and trading volume in Vietnam. Data used in this study mainly consist of daily VN30-Index and market trading volume series during the period from February 6th, 2012 to December 31st, 2019. Using OLS, GARCH(1,1) and EGARCH(1,1) models, the empirical findings consistently confirm that the introduction of index future trading has no impact on the spot market returns. In addition, the results of the EGARCH(1,1) model indicate that the leverage effect on the spot market volatility is existence in HOSE. Specifically, bad news has a greater effect on the market volatility than good news of the same size. Moreover, our empirical findings reveal that the introduction of index future contracts has the positive impact on the underlying market trading volume. Specifically, the trading volume of the post-index futures introduction increases by 7.5 percent compared with the pre-index futures introduction. Finally, the results obtained from the Granger causality test for the relationship between the spot market returns and the future trading activity confirm that only uni-directional causality running from the market returns to the future trading activity exists in HOSE.

Weldability of Aluminized Sheet Steels for Automobile Application(I) (Metallurgical Behavior of Resistance Spot Weld) (자동차용 알루미늄도금 강판의 용접성(I) (저항 점용접부의 금속학적 거동))

  • 김기철;차준호;이조영
    • Proceedings of the KWS Conference
    • /
    • 2003.05a
    • /
    • pp.99-101
    • /
    • 2003
  • This study deals with the resistance spot welding of aluminized steels. According to the test results it was clear that the weldability of aluminized steels was equivalent to or better than that of Zn coated steel. Microstructural inspection revealed that molten aluminum that was repelled from the weld during the process, piled up at the split zone. The test results also demonstrated that the weld metal of aluminized steels could hardly produce the weld crack even higher welding heat Input was applied.

  • PDF

Systematic review: agreement between the latent tuberculosis screening tests among patients with rheumatic diseases

  • Pyo, Junhee;Cho, Soo-Kyung;Kim, Dam;Sung, Yoon-Kyoung
    • The Korean journal of internal medicine
    • /
    • v.33 no.6
    • /
    • pp.1241-1251
    • /
    • 2018
  • Background/Aims: To estimate the level of agreement and positivity rates of latent tuberculosis infection (LTBI) tests prior to the use of tumor necrosis factor (TNF) inhibitors in relation to underlying rheumatic diseases and endemic tuberculosis levels. Methods: The Ovid-Medline, Embase, and Cochrane Libraries were searched for articles before October 2013 involving LTBI screening in rheumatic patients, including rheumatoid arthritis (RA), ankylosing spondylitis (AS), juvenile idiopathic arthritis (JIA), and psoriatic arthritis. Results: In pooled analyses, 5,224 rheumatic patients had undergone both a tuberculin skin test (TST) and an interferon-gamma release assay (IGRA) before TNF inhibitors use. The positivity of TST, QuantiFERON-TB Gold In Tube (QFT-GIT), and T-SPOT.TB (T-SPOT) tests were estimated to be 29%, 17%, and 18%, respectively. The agreement percentage between the TST and QFT-GIT, and between the TST and T-SPOT were 73% and 75%. Populations from low-to-moderate endemic TB presented with slightly less agreement (71% between TST and QFT-GIT, and 74% between TST and T-SPOT) than patients from high endemic countries (73% between TST and QFT-GIT, and 81% between TST and T-SPOT). By underlying disease stratification, a lower level of agreement between TST and QFT-GIT was found among AS (64%) than among JIA (77%) and RA patients (73%). Conclusions: We reaffirm the current evidence for accuracy of LTBI test done by TST and IGRA among rheumatic patients is inconsistent. Our stratified analysis suggests different screening strategies might be needed in clinical settings considering the endemic status in the patient's country of origin and the precise nature of underlying diseases.

An Evaluative Study on ESD(Entrance Surface Dose) by Posture Changes for Fluoroscopy (투시 검사 시 체위 변화에 따른 입사표면선량의 평가 연구)

  • Yang, Hae-Doo;Hong, Seon-Sook;Park, Eun-Seong;Seong, Min-Sook;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.177-183
    • /
    • 2011
  • This study intends to investigate patients' exact exposure doses by comparatively measuring ESD (Entrance Surface Dose) with the DAP meter, which excludes scattered rays, and ESD with the Xi multifunction meter, which includes scattered rays, by posture changes for Esophagography test and UGI test. The materialwere examined through Sonialvision-SafireII SPEC overtube system. ESD was measured by using the DAP meter, and as a tool to measure ESD including scattered rays on the plane of incidence of human phantom, the Xi multifunction meter was used. The average fluoroscopic time of Esophagography test was 4.192 minutes and the average number of images was 47.7, while the average fluoroscopic time of UGI test was 6.881 minutes and the average number of images was 37.8. The ratios of the incident dose of DAP meter and the ESD of Xi meter were calculated bydividing the fluoroscopic time and the number of images by each posture change. As for Esophagography test, the dose increased by 21.6~55.5% in the fluoroscopic test and by 4.8~24.7% in the spot test. In the front spot test, however, the does increased by as little as 5.3%. As for UGI test, the dose increased by 21.1~49.5% in the fluoroscopic test and by 10.1~34.9% in the spot test. It is expected that measuring doses in consideration of scattered rays by posture changes will be an important index in evaluating and managing patients' exact exposure doses for each test above. Furthermore, it is judged that this sort of study is inevitable and desirable to reduce patients' exposure doses after all.

  • PDF

Resistance Spot Weldability of Coated Steels for Automobile Applications (자동차용 도금강재의 저항 점용접부 특성)

  • Kim Ki Choi;Cha Joon Ho;Park Hwa Soon
    • Korean Journal of Materials Research
    • /
    • v.14 no.4
    • /
    • pp.239-245
    • /
    • 2004
  • Resistance spot weldability of coated steels for automobile applications was investigated. Test samples were prepared from commercial products of 0.8 mm in thickness. Based on the tensile-shear test, surface quality examination and cracking behavior, it was clear that aluminized steels showed good weldability. Microstructural inspection revealed that the coated materials was piled up at the split zone in the welding of aluminized steels. It was also demonstrated that no weld crack was found in the aluminized steel weld metal even the welding was carried out with higher current. However, through thickness cracks were detected at the weld metal of zinc coated steel. Small particles were found on the crack surface of zinc coated steel weld metal. It was thought that zinc vapor played key role to form the weld crack.

Spot Cooling System Development for Ever-bearing Strawberry by Using Low Density Polyethylene Pipe (연질 PE관을 이용한 여름딸기 부분냉방기술 개발)

  • Moon, Jong Pil;Kang, Geum Choon;Kwon, Jin Kyung;Lee, Su Jang;Lee, Jong Nam
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.6
    • /
    • pp.149-158
    • /
    • 2014
  • The effects of spot cooling on growing ever-bearing strawberry in hydroponic cultivation during summer by spot cooling system was estimated in plastic greenhouse located in Pyeongchang. The temperature of cooling water was controlled by heat pump and maintained at the range of $15{\sim}20^{\circ}C$. Cooling pipes were installed in root zone and very close to crown. Spot cooling effect was estimated by applying system in three cases which were cooling root zone, crown plus root zone, and crown only. White low density polyethylene pipe in nominal diameter of 16 mm was installed on crown spot, and Stainless steel flexible pipe in nominal diameter of 15A was installed in root zone. Crown and root zone cooling water circulation was continuously performed at flowrates of 300 ~ 600 L/hr all day long. Strawberry yields by test beds were surveyed from Aug. 1 to Sep. 30. The accumulated yield growth rate compared with a control bed of crown cooling bed was 25 % and that of crown plus root zone cooling bed was 25 % and that of root zone cooling bed was 20 %. The temperatures of root spot in root zone cooling was maintained at $18{\sim}23.0^{\circ}C$ and that of crown spot in crown cooling was maintained at $19{\sim}24^{\circ}C$. Also, the temperatures of root spot in crown plus root zone cooling bed was maintained at $17.0{\sim}22.0^{\circ}C$ and that of crown spot was maintained at $19{\sim}25^{\circ}C$.

A Homogeneous Immunoassay Method for Detecting Interferon-Gamma in Patients with Latent Tuberculosis Infection

  • Wu, Fei;Wang, Lin;Guo, Qiaomei;Zhao, Mingna;Gu, Hongchen;Xu, Hong;Lou, Jiatao
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.3
    • /
    • pp.588-595
    • /
    • 2016
  • IFN-γ release assays (IGRAs) have been developed as viable alternative diagnostic tools for detecting latent tuberculosis infection (LTBI). A customized homogeneous sandwich luminescent oxygen channeling immunoassay (LOCI) was used to quantify IFN-γ levels in IGRAs. Samples were collected from healthy volunteers (n = 40) who were T-Spot-negative and T-Spot-positive patients (n = 32) at rest. Then the amount of IFN-γ in the supernatant of IGRAs was measured by LOCI. The results demonstrated a low background, and high sensitivity, specificity, accuracy, and reproducibility, and a short assay time (only 30 min) with LOCI for IFN-γ. The recovery range was 81.63-102.06%, the coefficients of variation were below 5%, and the limit of detection was 19.0 mIU/ml. Excellent agreement between LOCI IFN-γ and the T-SPOT.TB test was obtained (97.2% agreement, κ = 0.94). The LOCI IFN-γ concentrations were significantly higher in T-Spot-positive patients than in the healthy group (p < 0.001). Moreover, as observed for the comparative LOCI IFN-γ assay, IFN-γ concentrations were related to the numbers of T-SPOT.TB spots. We have established an in vitro blood test for LTBI diagnosis, defined as LOCI IFN-γ. A high level of agreement between the LOCI IFN-γ method and T-SPOT.TB assay was observed in clinical studies that showed the LOCI IFN-γ method could determine LTBI. This study shows acceptable performance characteristics of the LOCI IFN-γ assay to diagnose LTBI.

Evaluation of Resistance Spot Weld Interfacial Fractures in Tensile-Shear Tests of TRIP 1180 Steels (인장전단시험을 이용한 TRIP1180강의 계면파단특성 평가)

  • Park, Sang-Soon;Choi, Young-Min;Nam, Dae-Geun;Kim, Young-Seok;Yu, Ji-Hun;Park, Yeong-Do
    • Journal of Welding and Joining
    • /
    • v.26 no.6
    • /
    • pp.81-91
    • /
    • 2008
  • The weldability of resistance spot welding of TRIP1180 steels for automobile components investigated enhance in order to achieve understanding of weld fracture during tensile-shear strength (TSS) test. The main failure modes for spot welds of TRIP1180 steels were nugget pullout and interfacial fracture. The peak load to cause a weld interfacial failure was found to be related to fracture toughness of the weld and the weld diameter. Although interfacial fracture occurred in the spot welded samples, the load-carrying capacity of the weld was high and not significantly affected by the fracture mode. Substantial part of the weld exhibits the characteristic dimple (or elongated dimple) fractures on interfacial fractured surface also, dimple fracture areas were drawmatically increased with heat input which is propotional to the applied weld current. In spite of the high hardness values associated with the martensite microstructures due to high cooling rate. The high load-carrying ability of the weld is directly associated with the area of ductile fracture occurred in weld. Therefore, the judgment of the quality of resistance spot welds in TRIP1180 steels, the load-carrying capacity of the weld should be considered as an important factor than fracture mode.