• Title/Summary/Keyword: Spot fire

Search Result 97, Processing Time 0.03 seconds

Effect of Harmonic Generation and Countermeasures (고조파발생에 따른 영향과 대책 연구)

  • Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.91-97
    • /
    • 2015
  • Skyscrapers, large business buildings, and IT consumers use many appliances, and the electrical power stems can cause fires by overheating. This can result in damaged capacitors, lost data, rising ground potential, and communication obstacles from linear or nonlinear high frequency. To make sure of that we investigated 7 spots of a building, among which 6-spots were fair but the other one needed high frequency control. Spots 3, 6, and 7 needed diagnostic workup, and spots 2, 3, and 5 considered 5 high frequency currents. A phase is all of good but the high frequency current is greater than the standard level except for spot 1. As a result, a zigzag transformer or active filter needs to be installed, and the efficiency needs to be upgraded by investigating load unbalance factors and power factors.

Estimation of Probability of Image Fusion to Improve Accuracy of NDVI Analysis (식생지수 분석의 정확도 향상을 위한 영상융합의 가능성 평가)

  • Song Yeong-Sun;Sohn Hong-Gyoo;Park Chung-Hwan
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.04a
    • /
    • pp.297-304
    • /
    • 2006
  • This paper estimates the probability of image fusion to improve accuracy of NDVl analysis. NDVI has been utilized in monitoring extensive forest or forest fire, and image fusion is a method to improve the resolution of multi-spectra image same resolution as high resolution panchromatic image. In this paper wavelet, PCA, IHS, Brovey and multiplicative method was applied to improve spatial resolution of SPOT-4 satellite image. NDVI images were generated from original and fused images and the correlation coefficient of fused and original image was calculated. The results of their comparison, PCA method showed best performance.

  • PDF

When mend piercing crack of large size mat basis, study of perforation and vottom repair that use water jet (대형매트기초의 관통균열 보수시 WATER JET을 이용한 천공과 저면보수에 관한 연구)

  • 박성우;한송수;이상헌;박찬규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.577-580
    • /
    • 2003
  • Problem of repairing by boring is that it deteriorates stabelety and durability of structure by permeation of seawater from underneath after damage and repair of reinforcing rod regarding of spot. The purpose of this study is to improve the porblem by using the repair method of general boring to mend the of large mat basis. Direction of thes experiment is to apply the new repair material and the method to control the blazing fire factor caused by the crack from the foundation of large mat and also to estimate it's integrity. New method of construction is method of contruction that do speace scurity in vertical drilling and bottom useing water jet. New material used bantonite and rubberized asphalt. Test result existent repair method of construction large size mat basis perforation is difficult and reinforcing rod can be damaged coule there were a lot of problems with re-water leakage of crack repair region, but overcomes existent short coming by method that apply in this study.

  • PDF

In Vitro Screening of Antibacterial Agents for Suppression of Fire Blight Disease in Korea (기내 검정법을 이용한 국내 과수 화상병 방제제 선발)

  • Lee, Min Su;Lee, Ingyeong;Kim, Sam Kyu;Oh, Chang-Sik;Park, Duck Hwan
    • Research in Plant Disease
    • /
    • v.24 no.1
    • /
    • pp.41-51
    • /
    • 2018
  • Since fire blight disease on apple and pear was produced in Korea in 2015, there were no registered chemicals to control against this disease. Instead, several antibacterial chemicals that were registered for other bacterial diseases such as soft rot and bacterial spot have been authorized by Rural Development Administration (RDA). However, these chemicals are not tested efficacy for fire blight disease except damage by those treatments on apple and pear in Korea. Thus, we evaluated efficiency using in vitro and in planta assays of antibacterial chemicals such as antibiotics and copper compounds including kasugamycin, oxytetracycline, oxolinic acid and streptomycin, and copper hydroxide, copper sulfate, oxine copper and tribasic copper sulfate, respectively. We also tested two kinds of biological agents. As expected, significant antibacterial effect was observed in vitro test of both antibiotics and copper-based chemicals. In planta test based on disease severity including ooze and water-soaked formation on immature pears, bacterial populations on blooms, and blight lesion formation in artificially inoculated shoots, kasugamycin, oxytetracycline and streptomycin have been shown the most efficiency among tested antibiotics. Four copper-based chemicals tested in this study, control effects are little bit lower than agricultural antibiotics but they seem to be available to use in terms of winter season. Biocontrol agents were also shown possibility to treat in eco-friendly farms. In addition, there are no antibiotic resistance genes in Korean isolates against antibiotics, which were selected for suppression of fire blight in this study.

Comparative Study on Waste Collection Factor in Jeju (제주도의 폐기물 수거요소 분석에 관한 비교 연구)

  • Kang, Hyun Choon;Kim, Tae Yoon;Yu, Seong Pil;Kang, Jin Young;Huh, Mock
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.1
    • /
    • pp.103-109
    • /
    • 2009
  • Analysis of collection factor was studied to compare various parameters such as collection time, transport time, amount of collection and number of man power by on-the-spot survey at one municipal area and one rural area in Jeju-do. Results showed that the amount of man and time to collect 1 ton of waste of rural area($5.853man{\cdot}hour\;per\;time$) was four times as much as that of municipal area($1.527man{\cdot}hour\;per\;time$). In case of a transport time, rural area(11.08 per km/hr) has similar value to municipal area(11.07 per km/hr) and has half or one third value to the restaurant(36.7km/hr), an apartment area(33.0km/hr) and a detached area(22.4km/hr).

Characteristic Analysis of Hot Spot Temperature according to Cooling Performance Variation of Natural Ester Transformer (식물성 절연유 변압기의 냉각특성 변화에 따른 최고점온도 특성 해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.236-240
    • /
    • 2015
  • Natural ester has a higher biodegradability, flash and fire points, and a greater permittivity compared to conventional mineral oils. However, natural ester also has a higher pour point, viscosity, and water content. These characteristics hamper circulation and the electrical properties of oil-filled transformer. Thus, this paper applied electromagnetic-thermal-flow coupled analysis method to predict temperature distribution inside 154kV single phase power transformer using natural ester. It modeled in the actual appearance for the tank and winding of the power transformer to improve the accuracy of analysis and applied heat flow analysis that considered hydromechanics and heat transfer at the same time. It calculated the power loss, the main cause of temperature rise, from winding and core with electromagnetic analysis then used for the heat source for the heat flow analysis. It then compared the reasonability of result of measurement analysis based on the result acquired from temperature rise test using FBG sensor on the power transformer.

The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition (일체형 주상용 몰드 변압기의 덕트에 따른 열해석 특성 연구)

  • 조한구;이운용;박영두
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.3
    • /
    • pp.348-352
    • /
    • 2004
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and ow loss, but it needs some cooling method because heat radiation between each winding is difficult. The life of transformer is significantly dependent on the thermal behavior in windings. Many transformer designers have calculated temperature distribution and hot spot point by finite element method(FEM) to analyze winding temperature rise. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

Temperature Rise Test and Temperature Distribution Analysis of Pole Mount Mold Transformer with One-body Molding (일체형 주상용 몰드 변압기의 온도분포 및 특성 비교)

  • Cho, Han-Goo;Lee, Un-Yong;Kang, Tack-Sou;Choi, In-Hyuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.12
    • /
    • pp.1154-1159
    • /
    • 2006
  • The mold transformers have been widely used in underground substations of large building and have some advantages when compared with oil-transformer. Those advantages are low fire risk, environmental compatibility, compact size and high reliability. The mold transformer is generally known to have cooling duct between low voltage and high voltage coil. To achieve better compact structure and low loss, mold transformers made by one body molding method has been developed. Nevertheless, such kinds of transformer need better cooling method because heat radiation between each winding is still of problem. The life of transformer is significantly dependent on the thermal behavior in windings. Many designers have calculated temperature distribution in transformers and hot spot point by finite element method(FEM) to analyze winding temperature rise. In this paper, the temperature distribution analysis of 100 kVA pole mold transformer for power distribution were investigated by FEM program and the thermal analysis results were compared with temperature rise test.

Preliminary Study of the Ecological Impact of Forest Fires in G. Massigit, G. Gede-Pangrango National Park, West Java

  • Abdulhadi, Rochadi;Adhikerana, A.S.;Ubaidillah, R.;Suharna, N.
    • The Korean Journal of Ecology
    • /
    • v.23 no.2
    • /
    • pp.125-129
    • /
    • 2000
  • Gunung Gede Pangrango National Park is one of the Long-term Ecological Research Site in Indonesia. In the late 1997, the fires have burnt and destroyed nearly 300 ha forest in this park. and G. Masigit was the largest burnt area (250 ha) of nine locations of hot spot recognized. Undergrowth vegetation got the most severe impacts. Almost undergrowth vegetation in various location were totally burnt. However, within three months following burning new seedlings such as Omalanthus populneus, Macaranga, Trema orientalis and Eupatorium appeared in the forest floor- The number of mycoflora recorded in burnt forest was interestingly increased in post forest fires site. Forest fires in G. Masigit had also affected the wild life population and diversity. For example, the number of bird species and the number of soil insects in burnt forest was significantly reduced. The forest fires had also great impact on soil. such as on soil organic contents, bulk density, colour, consistency, permeability and the activity of soil microorganisms.

  • PDF

The Design and Performance Test of Mold Transformer for Outdoor Pole (50 kVA 주상용 몰드변압기의 설계 및 특성평가)

  • Cho, Han-Goo;Lee, Un-Yong;HwangBo, Kuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.132-137
    • /
    • 2002
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. In this paper, the temperature distribution of 50 kVA pole mold transformer for power distribution are investigated by FEM program and the temperature rise test of designed mold transformer carried out and test result is analyzed compare to simulation data. In this result, the designed mold transformer is satisfied to limit value of temperature and the other property is good such as voltage ratio, winding resistance, no-load loss, load loss, impedance voltage and percent regulation.

  • PDF