• Title/Summary/Keyword: Spot fire

Search Result 97, Processing Time 0.022 seconds

A Risk Assessment in According to Spot Measures and Analysis in Dust Generation Area (분진발생지역의 현장실측과 분석을 통한 위험성 평가)

  • Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.103-110
    • /
    • 2008
  • In terms of electrical safety, environmental impact assessment and revision of domestic regulation are needed for the electric facilities. In this paper, risk of electric facilities is assessed by the spot measures and analysis in dust generation area. Adhesion dust in a surface of insulated materials cause electrical accidents. In a mechanism of these accidents, when the dust lie on electric facilities, a leakage current is flowed and the surface of insulated material is carbonized. Hereafter, electrical fire is generated due to Joule's heat. As the results, dusts are found in protection devices or panel board and sampled dusts vary in sampled amounts and conductivity severally. For the most part, sodium is detected but zinc and calcium are detected in case of reclaimed rubber factory by the ICP-AES(Inductively Coupled Plasma-Atomic Emission Spectroscopy). In a sewerage, the ingredients such as sodium, magnesium, iron, calcium, aluminium, etc are detected uniformly. So that, results of the spot measures and analysis of dusts are become the important data for the assessment of electrical hazard in dust generation area.

Quality comparison of musk products using a chromatographic pattern analysis (사향의 크로마토그램 패턴 분석을 통한 품질비교 연구)

  • Cho, Chong Woon;Gao, Dan;Kang, Jong Seong;Jung, Hyo won;Park, Yong-Ki
    • The Korea Journal of Herbology
    • /
    • v.36 no.4
    • /
    • pp.41-50
    • /
    • 2021
  • Objectives : This study is to check the quality of Moschus products in Korean markets using a chromatographic analysis. Methods : We collected musk products, two genuine products from Russia (A, B), two authentic products from Hong Kong (C) and Korea (D), the Ministry of Food and Drug Safety (MFDS) standard (E), and two fire ants products (E, F). Results : For identification, TLC analysis of 60% ethanol extracts of each product showed that A, B, C, and E have the suitable patterns before color development at 365 nm UV light for the MFDS regulation in Korea. A clear red spot was observed from the E at Rf 0.6 with 365 nm UV light after color development, but this spot was not found in A and B. For the purity test, a distinct violet spot with Rf 0.87 was observed from the A and B in TLC analysis of methanol extracts of each product at white light, however, this spot was not matched with the impurities of E and F. In HPLC-UV pattern analysis, a similar peak pattern was shown in A, B and E, and similar peaks were observed C, although the similarity was weaker than that of A, B, and E. The F and G showed different peak patterns compared with the peak patterns of other samples. Conclusions : Hence, it is considered that the test methods need flexibility in application for identification and purity test depending on the type of sample.

Qualitative analysis of some kinds of petroleum (thinner, gasoline, kerosene, and diesel oil) by gas chromatography (기체 크로마토그래피를 이용한 몇 가지 석유류(시너, 휘발유, 등유 및 경유)의 정성분석)

  • Hyun, Joon-Ho;Park, Jong-Heon;Kim, Sang-Soo;Choi, Jong-Moon
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.512-518
    • /
    • 2006
  • The evidence containing some kind of petroleum at the fire spot was analyzed by gas chromatography to identify a fire's sources. To extract some petroleum from fire evidence, 10.0 mL of n-hexane was added in this solution, and it was shaken for 30 minutes. To identify a kind of petroleum in fire evidence, the prepared n-hexane solution was injected and analyzed in the gas chromatograph. The chromatogram of sample was different from those of thinner and gasoline that have low boiling point, and shown different peak pattern to heating and boiler oils. But it was similar to the chromatogram of diesel oil. After small amount of diesel oil was added to the sample, the area of characteristic peaks was increased more than those of raw sample. From the results, the kind of petroleum in the fire evidence was diesel oil.

Research of Accelerated Aging According to Long-term Stability of Vegetable Oil (식물성절연유의 가속열화에 따른 장기적 안정성 분석)

  • Choi, Sun-Ho;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1148-1152
    • /
    • 2012
  • The vegetable-based insulating oils are substitutes for mineral oils in oil-filled transformer. The important properties of vegetable insulating oil is their higher flash/fire point and biodegradability than conventional mineral oils. The large oil-filled transformer eliminate the risk of explosion and fire should the transformer fail and oil ignite owing to high flash/fire point of vegetable insulating oil. In addition, higher biodegradability of vegetable insulating oils can let the oil spill damage reduced. In this experiment, the real oil-filled transformers using mineral oil and vegetable oil have accelerated aging. After working on the 100% accelerated aging experiment were conducted comparing the transformer. The hottest-spot temperature using thermal coefficients were calculated to determin the degree of accelerated aging. As a result, apply mineral oil transformer in accordance with the accelerated aging life come to an end. In contrast, vegetable insulating oils showed the opposite characteristics. Vegetable insulating oil compared to the mineral oil are found to be an long life. As a result, the vegetable oil has a long-term stability.

Action Plan of Security Service against a Fire case in a Tall Building Event (경호행사시 초고층건물 화재 대응방안)

  • Son, Kyung-Hwan
    • Korean Security Journal
    • /
    • no.39
    • /
    • pp.37-61
    • /
    • 2014
  • Nowadays the world is threatened because of terrors that take aim at Soft-Targets available and easy to access to the people rather than more secured Hard-Targets. The inspection department of the Presidential Security Service develops and acts a perfect safety plan wherever the President stays so that it is possible to get immediate actions for various contingencies. Some events, in which the President take part, could be held in a lower or higher store in a tall building. Additional to the routine work at this case it is to emphasize on a plan of fire precaution to check the spot and respond to a real fire situation, so that the damage could be minimized. First, the agents of the President Security Service should possess basic knowledge concerning to the fire accidents and be trained on their manuals, even in a busy events plan. An organization, whatever it is, could be improved in that it tries to develop not only the personal abilities, but also education programs of the organization continually. And enhanced abilities of the members lead to the driving force for the advance. The knowledge of fire accident should be able to adapt to the real situation. Second, related to the event, it should be cooperated with the relevant departments, so that it is possible to conduct and control the system. It is urgently required to know that the security event could not be done perfectly with only one part or department. Third, from the time of recognizing of the event it is necessary for the fire department to get an action plan with fire fighting measures, evacuation measures based of the instructions given by the Security Service. Fourth, on the knowledge of the action plan of the fire department the Security Service should inspect the safety activities of the spot and establish the practical operation plan through the fire fighting and evacuation plan. Fifth, the Security Service should share final informations and plan of fire fighting in a high-rise building with the other relevant departments. If not, it could cause a great confusion that could lead to a great damage.

  • PDF

A Study on the Improvement of Fire Alarm System in Special Buildings Using Beacons in Edge Computing Environment (에지 컴퓨팅 환경에서 비콘을 활용한 특수건물 화재 경보 시스템 개선 방안 연구)

  • Lee, Tae Gyu;Choi, Kyeong Seo;Shin, Youn Soon
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.11 no.7
    • /
    • pp.217-224
    • /
    • 2022
  • Today, with the development of technology and industry, fire accidents in special buildings are increasing as special buildings increase. However, despite the rapid development of information and communication technology, human casualties are steadily occurring due to the underdeveloped and ineffective indoor fire alarm system. In this study, we confirmed that the existing indoor fire alarm system using acoustic alarm could not deliver a sufficiently large alarm to the in-room personnel. To improve this, we designed and implemented a fire alarm system using edge computing and beacons. The proposed improved fire alarm system consists of terminal sensor nodes, edge nodes, a user application, and a server. The terminal sensor nodes collect indoor environment data and send it to the edge node, and the edge node monitors whether a fire occurs through the transmitted sensor value. In addition, the edge node continuously generate beacon signals to collect information of smart devices with user applications installed within the signal range, store them in a server database, and send application push-type fire alarms to all in-room personnel based on the collected user information. As a result of conducting a signal valid range measurement experiment in a university building with dense lecture rooms, it was confirmed that device information was normally collected within the beacon signal range of the edge node and a fire alarm was quickly sent to specific users. Through this, it was confirmed that the "blind spot problem of the alarm" was solved by flexibly collecting information of visitors that changes time to time and sending the alarm to a smart device very adjacent to the people. In addition, through the analysis of the experimental results, a plan to effectively apply the proposed fire alarm system according to the characteristics of the indoor space was proposed.

Local Imbalance of Emergency Medical Services(EMS): Analyses on 119 EMS Activity Reports of Busan (구급서비스의 지역 불균형: 부산시 119 구급활동일지 분석)

  • Lee, Dalbyul
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.3
    • /
    • pp.161-173
    • /
    • 2020
  • This study analyzed local imbalances in the supply and demand of emergency medical services in Busan using the 119 emergency activity reports of the Busan Fire & Disaster Headquarters. The data for EMS activity reports in 2017 was converted into Jimgyegu units. The spatial distribution of the indicators representing the local imbalance of emergency demand and supply (number of reports, number of reports relative to the population, average coefficient of variation and outlier of on-site arrival time, and number of dispatches outside the jurisdiction) was analyzed using Hotspot analysis of GIS spatial statistics analysis. As a result of the analysis, the hot spot area and the cold spot area where both supply and demand of emergency services are concentrated were clearly distinguished. This means that the supply and demand of emergency services in Busan are locally unbalanced. In particular, there was a difference in the demand and supply of emergency services in the original downtown and its surrounding areas, and in the outskirts of Busan.

An Analysis on the Spatial Pattern of Local Safety Level Index Using Spatial Autocorrelation - Focused on Basic Local Governments, Korea (공간적 자기상관을 활용한 지역안전지수의 공간패턴 분석 - 기초지방자치단체를 중심으로)

  • Yi, Mi Sook;Yeo, Kwan Hyun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.1
    • /
    • pp.29-40
    • /
    • 2021
  • Risk factors that threaten public safety such as crime, fire, and traffic accidents have spatial characteristics. Since each region has different dangerous environments, it is necessary to analyze the spatial pattern of risk factors for each sector such as traffic accident, fire, crime, and living safety. The purpose of this study is to analyze the spatial distribution pattern of local safety level index, which act as an index that rates the safety level of each sector (traffic accident, fire, crime, living safety, suicide, and infectious disease) for basic local governments across the nation. The following analysis tools were used to analyze the spatial autocorrelation of local safety level index : Global Moran's I, Local Moran's I, and Getis-Ord's G⁎i. The result of the analysis shows that the distribution of safety level on traffic accidents, fire, and suicide tends to be more clustered spatially compared to the safety level on crime, living safety, and infectious disease. As a result of analyzing significant spatial correlations between different regions, it was found that the Seoul metropolitan areas are relatively safe compared to other cities based on the integrated index of local safety. In addition, hot spot analysis using statistical values from Getis-Ord's G⁎i derived three hot spots(Samchuck, Cheongsong-gun, and Gimje) in which safety-vulnerable areas are clustered and 15 cold spots which are clusters of areas with high safety levels. These research findings can be used as basic data when the government is making policies to improve the safety level by identifying the spatial distribution and the spatial pattern in areas with vulnerable safety levels.

A Design of Fire Monitoring System Based On Unmaned Helicopter and Sensor Network (무인헬기 및 센서네트워크 기반 화재 감시 시스템 설계)

  • Yun, Dong-Yol;Kim, Sung-Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.2
    • /
    • pp.173-178
    • /
    • 2007
  • Recently, fires happen to occur owing to various factors. However, the demage caused by the fire is eyer increasing because timely actions could not be taken. To reduce the demage, a development of fire detection system which makes it possible to take adequate actions is requited. In this work, a sensor network-based fire detection system which utilizes both sensor nodes equipped with smoke sensor and unmaned helicopter is proposed. The proposed system is composed of unmaned helicopter which can gather the measurement data from the deployed sensor nodes and the embedded system which can get visual information on the firing spot and transmit these images to a remote server computer. The proposed system is applied to actual test bed to verify its feasibility.

Survey on the Occurrence of Apple Diseases in Korea from 1992 to 2000

  • Lee, Dong-Hyuk;Lee, Soon-Won;Choi, Kyung-Hee;Kim, Dong-A;Uhm, Jae-Youl
    • The Plant Pathology Journal
    • /
    • v.22 no.4
    • /
    • pp.375-380
    • /
    • 2006
  • In the survey from 1992 to 2000, twenty-eight parasitic diseases were observed in major apple producing areas in Korea. The predominant apple diseases were white rot(Botryosphaeria dothidea), Marssonina blotch(Marssonina mali), Valsa canker(Valsa ceratosperma), Alternaria leaf spot(Alternaria mali), and bitter rot(Collectotrichum gloeosporioides and C. acutatum). Apple scab that reappeared in 1990 after disappearance for 15 years was disappeared again since 1997. A viroid disease(caused by apple scar skin viroid) was newly found in this survey. The five diseases, fire blight(Erwinia amylovora), black rot(Botryosphaeria obtusa), scab(Cladosporium carpophilum), Monochaetia twig blight(Monochaetia sp.), and brown leaf spot(Hendersonia mali), which had once described in 1928 but no further reports on their occurrence, were not found in this survey. However, blossom blight(Monilinia mali), brown rot(Monilinia fructigena), and pink rot(Trichothecium roseum), which did not occur on apple after mid 1970s, were found in this survey.