• Title/Summary/Keyword: Split angle

Search Result 148, Processing Time 0.031 seconds

Load Transfer Mechanism of a Hybrid Beam-Column Connection System with Structural Tees

  • Kim, Sang-Sik;Choi, Kwang-Ho
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.3E
    • /
    • pp.199-205
    • /
    • 2006
  • The composite frame system with reinforced concrete column and steel beam can be improved in its structural efficiency by complementing the shortcomings of the two systems. The system, however, has many inherent problems in practical design and construction process due to the dissimilarities of the materials. Considering these circumstance, this research aims for the development of a composite structural system which connects the steel beams to the R/C columns with higher structural safety and economy. Basically, the proposed connection system is composed of four split tees, structural angles reinforced by a stiffener, high strength steel rods, connecting plates and shear plates. Structural tests have been carried out to investigate the moment transfer mechanism 1Tom the beam flange to steel rods or connecting plates through the structural angle reinforced by a stiffener. The four prototype specimens have been tested until the flange of the beam reached a plastic state. The test results indicated that no distinct material dissimilarities between concrete and steel have been detected for the proposed hybrid beam-column connection system and that the stress transfer through the structural angle between the beam flange and steel rods or connecting plates was very encouraging.

SOFT TISSUE CHANGES AFTER DOUBLE JAW ROTATION SURGERY IN SKELETAL CLASS III MALOCCLUSION (골격성 III 급 부정 교합자에서 양악 회전 수술 후 연조직 변화에 대한 연구)

  • Jeong, Mi-Hyang;Choi, Jeong-Ho;Kim, Byuong-Ho;Kim, Seong-Gon;Nahm, Dong-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.6
    • /
    • pp.559-565
    • /
    • 2006
  • The aim of this study was to evaluate the amount and interrelationship of the soft and hard tissue changes after simultaneous maxillary clockwise rotation and mandibular setback surgery in skeletal class III malocclusion. The sample comprised of 16 adult patients who had anteroposterior skeletal discrepancy. These patients had received presurgical orthodontic treatment and surgical treatment which consisted of Le fort I Osteotomy and bilateral saggital split ramus osteotomy. The presurgical (T1) and postsurgical (T2) lateral cephalograms were evaluated. The computerized statistical analysis was carried out with SPSS/PC program. The results demonstrated a decrease in the vertical dimension in the soft and hard tissue. The nasolabial angle was increased and the mentolabial angle was decreased. The results showed also many statistically significant correlations(p<0.05). The lower lip closely followed the skeletal movement of the B- point in the horizontal plane. The double jaw rotation surgery can afford a good solution to solve the problems of class III malocclusion cases.

A Study on the Integrated Dynamic Control System to Improve the Lateral Dynamics and Ride Comfort of SUV Vehicles (SUV 차량의 횡방향 운동 및 승차감 개선을 위한 제동장치를 이용한 통합운동제어장치의 연구)

  • Song, Jeonghoon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.4
    • /
    • pp.70-75
    • /
    • 2018
  • This paper describes an Integrate Dynamic Control system with Brake System (IDCB) for SUV vehicles. The system was developed to stabilize the lateral dynamics, maintain the steerability and improve the ride comfort on various roads. A fuzzy logic control method is used to design the IDCB. The performance of the IDCB is validated under different road and driving conditions. The results show that the IDCB tracks the reference yaw rate under all tested conditions; in addition, it reduces the body slip angle and roll angle. When a vehicle runs on a split-${\mu}$ road and a brake input is applied, the IDCB virtually eliminates the lateral dynamics. Thus, the IDCB improves the lateral stability, preserves the steerability and enhances the ride comfort of vehicles.

A Study on the Ink Transfer Using the Roughness and Substrate Energy of Substrate in Roll to Roll Printing Systems (롤투롤 인쇄 시스템에서의 기판 소재의 거칠기와 표면에너지를 이용한 잉크 전이에 대한 연구)

  • Shin, Kee-Hyun;Kim, Ho-Joon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.2
    • /
    • pp.103-109
    • /
    • 2010
  • An ink transfer is modeled and experimentally verified using roll-to-roll electric direct gravure printing process. The ink transfer model based on the physical mechanism for the maximum ink transfer rate is proposed, and experimented by the electric printing machine in FDRC for the relations of the maximum ink transfer rates to the printing pressure, the operating speed, the operating tension, the surface roughness of substrates, and the contact angle between substrate and silver ink. The free ink split coefficient and immobilized ink under the maximum ink transfer rate are calculated by the physical parameter in a printing process and contact angle between substrates and ink. Numerical simulations and experimental studies were carried out to verify performances of the proposed ink transfer model. Results showed that the proposed ink transfer model was effective for the prediction of the amount of transferred ink to the substrate in a direct gravure printing systems.

Real-time Measurement of Full Field Retardation Near Quarter Wavelength

  • Liu, Longhai;Zeng, Aijun;Yuan, Qiao;Zhu, Linglin;Fang, Ruifang;Huang, Huijie
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.457-461
    • /
    • 2012
  • A real-time method to measure full field retardation near quarter wavelength is proposed. The circularly polarized beam passes through a sample with a large aperture. The measuring beam then goes through a quarter-wave plate and is then split by a Wollaston prism. An image with two sub-images is then detected by a high-speed image sensor. The full field retardation near quarter wavelength can be obtained in real time by processing the image. The measured retardation is independent of the fast axis angle of the sample and the fluctuation of the initial intensity. In experiments, a wedge waveplate is measured with different fast axis angle and initial intensity, and the full field retardations are acquired. The maximum and standard deviation of the full field retardation is $1.5^{\circ}$ and $0.4^{\circ}$. The validity of the method is verified.

MORPHOLOGIC AND POSITIONAL CHANGE OF THE PROXIMAL SEGMENTS AFTER INTRAORALVERTICAL RAMUS OSTEOTOMY OF THE MANDIBULAR PROGNATHISM ON SUBMENTOVERTEX CEPHALOGRAM (하악골 전돌증환자의 구내 하악골상행지 수직골절단술후 이하두정 계측방사선사진상에서의 근심골편의 형태 및 위치 변화)

  • Chung, Jae-Hyung;Park, Hyung-Sik;Hwang, Chung-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.1
    • /
    • pp.26-34
    • /
    • 2003
  • Intraoral Vertical Ramus Osteotomy,along with Sagittal Split Ramus Osteotomy,is an popular surgical technique performed on mandibular prognathism. However Intraoral Vertical Ramus Osteotomy has been suspected for an initial mobilization at the healing phase of segment because it does not employ the rigid fixation between segments. To execute a study on the healing phase of segment after Intraoral Vertical Ramus Osteotomy on the horizontal plane, 102 patients (204 parts) who were diagnosed mandibular prognathism and took Intraoral Vertical Ramus Osteotomy at the Yonsei University dental hospital were observed during the period of before operation, immediately postoperation, 1 month, 3 months, 6 months, and 12 months. The change in the width of segment and horizontal angle of proximal segment and condylar head on the Submentovertex Cephalogram taken from those patients represented following results. 1. The width of proximal and distal segment decreased with the lapse of time. It decreased into 84.5% between immediate postoperative and 6M and even continued to decrease till 12M. 2. The horizontal angle of the proximal segment did medial rotation according as the lapse of time and rigorously continued till 3M. The rotation angle of condylar head indicated its tendency of recurrence to the original position but the entire recurrence was not allowed. The bigger an initial angle was, the higher was the tendency of recurrence after the operation while the rotation angle remained still bigger. 3. After grouping into group 1, group 2,and group 3 based on the extent of the variation of rotation angle of condylar head at immediate postoperative, the variation of rotation angle was measures in each group. The result presented that the initial rotation angle of condylar head had correlation with that of proximal segment but had no relation with the extent of setback of the mandible. However a quantitative analysis alone is not a sufficient method for analyzing the healing phase of segment on the horizontal plane.Therefore a multilateral analysis using 3 dimensional data such as CT is recommendable for the future study.

Postoperative Stability and Occlusal Plane Alternation by Orthognathic Surgery of Skeletal Class III Malocclusion with Anterior Open Bite (전치부 개교를 동반한 골격성 III급 부정교합 환자의 악교정 수술 후 교합평면의 변화와 안정성에 관한 연구)

  • Shin, Soo-Jung;Hwang, Byung-Nam;Lee, Jung-Keun;Rhee, Seung-Hoon
    • The korean journal of orthodontics
    • /
    • v.29 no.1 s.72
    • /
    • pp.113-127
    • /
    • 1999
  • The purpose of this study is to investigate the stability of counterclockwise rotation of mandible by sagittal split ramus osteotomy to correct the skeletal Class III malocclusion with anterior open bite. Twenty five skeletal Class III open bite patients(mean age 20.6 years) who were treated by the sagittal split ramus osteotonues with rigid fixation were examined in this study. Cephalometric radiographs were taken for each Patients Preoperative(T1), ewly Postoperative(T2), and late postoperative Period(T3). Mean postoperative period was 8.0 months. Cephalometric analysis was done and data from T1, T2, and T3 were analyzed statistically by Paired t-test and Pearson correlation analysis. The following results were obtained. 1. Mandibular plane angle decreased $2.9^{\circ}$ and mandibular occlusal plane angle related to SN Plane decreased $2.7^{\circ}$ after orthognathic surgery(T2). At 6 months after orthognathic surgery(T3), mandibular plane angle increased $1.0^{\circ}$, but mandibular occlusal plane angle did not changed. 2. The amount of horizontal relapse long time after orthognathic surgery(T3) was 1.6 mm at B point and it was $22\%$ of the total posterior movements. There was no vertical relapse in the anterior facial height. 3. The related factor with horizontal relapse at late postoperative period was mandibular plane angle(p<0.01). The related factors with decreasing posterior facial height were amount of mandibular setback(p<0.01), increasing of mandibular ramus height(p<0.01), and decrease of the mandibular plane angle during operation(p<0.01). 4. There was no relationship between the amount of changes in mandibular occlusal plan angle during operation and the amount of relapse after surgery.

  • PDF

Elastic properties of addition silicone interocclusal recording materials (부가중합형 실리콘 교합인기재의 탄성 특성)

  • Lee, Young-Ok;Kim, Kyoung-Nam
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.3
    • /
    • pp.513-520
    • /
    • 2012
  • Objectives : In this study, contact angle and shore D hardness were measured, and a shark fin test was conducted after selecting five addition silicon(Blu-Mousse, BM; EXABITE II, EX; PERFECT, PF; Regisil$^{(R)}$ Rigid, RE; Silagum$^{(R)}$, SI) in order to figure out the properties of elastomeric interocclusal recording materials and reduce errors at interocclusal recording. 8) Methods : A contact angle was measured using a contact angle analyzer. After placing a drop of liquid on the surface of the specimens of interocclusal recording materials, a contact angle was photographed with a CCD camera on the equipment. In terms of a shark fin test, interocclusal recording materials were mixed for the time proposed by the manufacturer and inserted into the split ring of the Shark fin device. Twenty (20) seconds exactly, a metal rod was removed to make the materials slowly absorbed. Once they hardened, fin height was measured with a caliper after separating molds and trimming the specimens. The shore D hardness was measured with a shore D hardness tester(Model HPDSD, Hans Schmidt & Co. Gmbh, Germany) in sixty (60) minutes after fabricating specimens. In each experiment, five specimens, mean and standard deviation were calculated. A one-way ANOVA test was performed at the p>0.05 level of significance. In terms of correlation among the tests, Pearson correlation coefficient was estimated. For multiple comparison, Scheffe's test was carried out. Results : A contact angle was the highest in EX with $99.23^{\circ}$ (p<0.05) while the result of the shark fin test was the longest in RE with 5.45mm. SI was the lowest (0.27mm) with statistical significance. Among the interocclusal recording materials, significant difference was observed in terms of means (p<0.05). The shore D hardness was the highest in SI with 31.0 while RE was significantly low with 16.4 (p<0.05). Among the materials, statistically significant difference was observed in terms of means when compared to the rest materials (RE), BM, RE and SI (PF and EX) and the remaining materials (BM and SI) (p<0.05). In terms of correlations among the tests, a negative correlation occurred between shore D hardness and shark fin test(r=-0.823, p=0.000). Conclusions : According to the study above, it is necessary to understand the properties of interocclusal recording materials and consider contact angle, shark fin test and properties of shore D hardness to select appropriate materials.

SKELETAL RELAPSE AFTER ORTHOGNATHIC SURGERY OF CLASS III SKELETAL OPEN-BITE (개구교합을 가진 3급 부정교합환자의 악교정수술후 재발에 관한 연구)

  • Song, Jae-Chul;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.15 no.3
    • /
    • pp.229-237
    • /
    • 1993
  • This study was intended to evaluate a post-operative relapse tendency in mandibular prognathism patients with open-bite. 18 patients with or without open-bite have undergone sagittal split ramus osteotomy and were investigated radiologically with cephalogram. The results were as following 1. The preoperative anterior facial height, mandibular plane angle and mandibular gonial angle were larger in open-bite patients than in nonopen-bite patients.(p>0.05) 2. There was significant correlation between surgical change of SNA, mandibular plane length and long-term relapse.(p<0.01). 3. There was relatively stable postoperative anterior facial height in open bite patients. 4. There was no significant correlation between the surgical change of mandibular plane angle, amount of mandibular setback and long-term relapse.(p>0.01) 5. This study showed that horizontal relapse was more significant than vertical relapse.

  • PDF

Acoustic Target Strength of Live Japanese Common Squid(Todarodes pacifica) for Applying Biomass Estimation (살오징어 (Todarodes pacifica)의 음향 반사강도 측정)

  • KANG Donhyug;HWANG Doojin;MUKAI Tohru;IIDA KohjI;LEE Kyounghoon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.4
    • /
    • pp.345-353
    • /
    • 2004
  • Target strength (TS) of Japanese common squids (Todarodes pacificus) were measured using 38 and 120 kHz split beam scientific echosounders under the live condition. For the TS measurement of an individual, a total of 3 squids (mantle length (ML): 22.8, 25, and 27 cm) were used using small fishhook method, whereas for measurement of swimming angle, a total of 8 squids (ML: 21-27 cm) were used under live condition, confined with net cage with 2 m diameter At the same time, two underwater video cameras enabled continuous monitoring of squid behavior. Considering normal behavior, the mean TS at 38 and 120 kHz varied from -48.6 to -45.9 dB, and from -46.5 to -44.6 dB, respectively In both frequencies, mean TS at 120 kHz is relatively higher than that of 38 kHz, approximately 1.3-2.5 dB. From free living condition, the mean swimming angle of the squlds was $-24^{\circ}$. The results of the measurement will be provided basic information for conducting acoustic surveys of the squid.