• Title/Summary/Keyword: Split angle

Search Result 148, Processing Time 0.026 seconds

Optical Properties of Porous-Si Layers on Si-substrate and its Application of Polarization Devices (Porous Si layer의 광학특성과 편광소자에의 응용)

  • Koo, K.W.;Hwang, J.H.;Shiraishi, K.;Matsumura, K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2453-2455
    • /
    • 1999
  • We propose that we use a porous-Si for a new spatial walk-off polarizing material with a large split angle. The beam-split an91e f is determined by the filling factor g(or porosity p) of the columnar dielectric substance and the slant angle $\theta$. Theoretically, by the assuming that $n_2$=3.5, and $n_1$=1 one can predict that a large split angle, up to $27^{\circ}$, is possible if one can construct such films with $Si.^{[3]}$ To accomplish this, we use porous-Si. As a result of theoretical simulation, the best structural parameters for attaining the maximum split angle $\phi$=$27.5^{\circ}$ are $\theta$=$58.7^{\circ}$ and p=57.6%.

  • PDF

ANALYSIS OF SHORT FACE TENDENCY AND IT'S DETERMINANT FACTORS AFTER BILATERAL SAGITTAL SPLIT RAMUS OSTEOTOMY OF MANDIBULAR PROGNATHISM (하악전돌증 환자의 하악지시상분할골절단술 후 단안모화 경향과 그 결정인자에 대한 분석)

  • Kang, Ji-Yeon;Choi, Hee-Won;Kim, Kyoung-Won
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.6
    • /
    • pp.407-420
    • /
    • 2003
  • Purpose : The purpose of this study was to analyse the facial changes and factors contributing to then after bilateral sagittal split ramus osteotomy of mandibular prognathism. Materials and Methods : Forty patients with Class III dental and skeletal malocclusion who were treated with bilateral sagittal split ramus osteotomy were reviewed. Frontal and lateral cephalometric radiographs were taken preoperatively, immediate postoperatively and more than six months postoperatively in each patient. After tracing the cephalometric radiographs, various parameters were measured. Results : 1. Gonial angle at postoperative two days was decreased about $10.4^{\circ}$ than preoperatively and gonial angle at postoperative six months was increased about $6.8^{\circ}$ than postoperative two days. So, gonial angle at postoperative six months was decreased about $3.6^{\circ}$ than preoperative gonial angle. 2. Facial height postoperative two days was decreased about 0.8mm than preoperatively and facial height at postoperative six months was decreased about 0.7mm than postoperative two days. So, facial height at postoperative six months was decreased about 1.5mm than preoperative facial height. 3. Mandibular width postoperative two days was decreased about 1.0mm than preoperatively and mandibular width at postoperative six months was increased about 1.8mm than postoperative two days. So, mandibular width at postoperative six months was decreased about 2.8mm than preoperative mandibular width. 4. Amount of set back and mandibular plane angle were not influencing on relapse degree. Conclusion : It is thought that bilateral sagittal split ramus osteotomy in mandibular prognathic patients is effective to improve long face and steep gonial angle. More prudent operation and careful postoperative management is required to maintain stable face postoperatively. Further research for soft tissue changes and factors which are related with relapse is needed.

Feasibility Study of Laser Contact Angle Measurement for Nano-fiber Characterization (나노섬유의 특성분석을 위한 레이저 접촉각 측정기의 효율성 연구)

  • 신경인;안선훈;김성훈
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.5
    • /
    • pp.554-559
    • /
    • 2003
  • A newly developed contact angle measurement instrument by laser beam projection allows for rapid and direct determination of contact angles. The instrument may have a possibility to characterize newly developed nano-fibers. When the laser beam impinges on an edge of an interface of liquid and solid, projected beam were split across and made two straight lines on a tangent screen. From the result, it could measure the contact angle directly by reading the angle between two split beams. The purpose of this study was to prove reliability and reproducibility of the contact angle measurement instrument by laser beam projection compare to the conventional one by microscope through the comparative experiment and questionnaire. Test samples were selected by consideration of hydrophilic and hydrophobic, such as nylon 6 and polypropylene, respectively. The laser contact angle measurement has accurate, fast and convenient method to measure contact angle, and it can be a unique method to characterize nano-fibers.

The mixing characteristics of Unlike Split Triplet(F-O-O-F) Impinging-Jet Injector Elements (F-O-O-F 인젝터의 혼합 특성)

  • Lim Byoungjik;Jung Kihoon;Yoon Youngbin
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.283-286
    • /
    • 2002
  • The mixing of fuel and oxidizer and each mass distribution of unlike split triplet(F-O-O-F) injector for liquid rocket which are known to affect the combustion efficiency significantly, has been investigated using PLLIF technique. Experiment is conducted to investigate the effect of mixture ratio(MiR), momentum ratio(MoR) and impinging angle on mixing efficiency. The mixing efficiency, which is introduced by Rupe, gives the global chracteristic of spray mixing. Experiment far comparison with triplet injector(F-O-F), which has same momentum ratio and impinging angle with split triplet injector is conducted.

  • PDF

The Effect of Standard Keyboard and Fixed-Split Keyboard on Wrist Posture During Word Processing (문서입력 작업 시 컴퓨터 키보드 유형이 손목관절의 운동학적 특성에 미치는 영향)

  • Kwon, Hyuk-Cheol;Jeong, Dong-Hoon;Kong, Jin-Yong
    • Physical Therapy Korea
    • /
    • v.11 no.1
    • /
    • pp.35-43
    • /
    • 2004
  • There were two purposes of this study. The first was to research the effects of standard and fixed-split keyboards on wrist posture and movements during word processing. The second was to select optimal computer input devices in order to prevent cummulative trauma disorder in the wrist region. The group of subjects consisted of thirteen healthy men and women who all agreed to participate in this study. Kinematic data was measured from both wrist flexion and extension, and wrist radial and ulnar deviation during a 20 minute period of word processing work. The measuring tool was an electrical goniometer, and was produced by Biometrics Cooperation. The results were as follows: 1. The wrist flexion and extension at resting starting position were not significantly different (p>.05), however the angle of radial and ulnar deviation were significantly different in standard and split keyboard use during word processing (p<.05). 2. In the initial 10 minutes, the dynamic angle of wrist flexion and extension were not significantly different (p>.05), however the dynamic angle of radial and ulnar deviation was significantly different in standard and split keyboard use during word processing (p<.05). These results suggest that the split keyboard is more optimal than the standard keyboard, because it prevented excessive ulnar deviation during word processing.

  • PDF

GONIAL ANGLE REDUCTION DURING MANDIBULAR SAGITTAL SPLIT RAMUS OSTEOTOMY (하악지 시상 분할골절단술과 동시에 시행되는 우각부 절제술)

  • Kim, Jae-Seung;Chang, Hyun-Ho;Ryu, Sung-Ho;Kang, Jae-Hyun;Lee, Seung-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.258-265
    • /
    • 2001
  • A prognathic mandible and prominent gonial angle are considered to be unattractive in the Orient because it gives the face a square and muscular appearance. Requests for contouring of the mandibular angle are rare in the other race but are much more common in Korea and, through out the Orient. So, we often encounter a patient with a prognathic mandible and squarish or broad face who wishes to have his or her facial size reduced minimally or to acquire a round or slender appearance. But, mandibular angle is located in the deepest part of the operative field and the strong tension of the lateral soft tissue makes retraction difficult. It is extremely difficult to reduce the gonial angle with sagittal split ramus osteotomy by intraoral approach at the same time. We apply the method of gonial angle reduction during SSRO and had satisfactory results. We will present our results and hope to give some useful information for management of mandibular deformity.

  • PDF

The study on the Removal of Metallic Impurities with using UV/ozone and HF cleaning (금속불순물 제거를 위한 UV/ozone과 HF 세정연구)

  • Lee, Won-Jun;Jeon, Hyeong-Tak
    • Korean Journal of Materials Research
    • /
    • v.6 no.11
    • /
    • pp.1127-1135
    • /
    • 1996
  • 반도체 소자가 고집적화 됨에 따라 단위공정의 수가 증가하게 되었고 동시에 실리콘 기판의 오염에 대한 문제가 증가하였다. 실리콘 기판의 주 오염물로는 유기물, 파티클, 금속분순물 등이 있으며 특히, Cu와 Fe과 같은 금속불순물은 이온주입 공정, reactive ion etching, photoresist ashing과 같은 실 공정 중에 1011-1013atoms/㎤정도로 오염이 되고 있다. 그러나 금속불순물 중 Cu와 같은 전기음성도가 실리콘 보다 큰 오염물질은 일반적인 습석세정방법으로는 제거하기 힘들다. 따라서 본 연구에서는 Cu와 Fe과 같은 금속불순물을 제거할 목적을 건식과 습식 세정방법을 혼합한 UV/ozone과 HF세정을 제안하여 실시하였다. CuCI2와 FeCI2 표준용액으로 실리콘 기판을 인위적 오염한 후 split 1(HF-only), split 2 (UV/ozone+HF), split 3 (UV/ozone + HF 2번 반복), split 4(UV/ozone-HF 3번 반복)를 실시하였고 TXRF(Total Reflection X-Ray Fluorescence)와 AFM(Atomic Force Microscope)으로 금속불순물 제거량과 표면거칠기를 각각 측정하였다. 또한 contact angle 측정으로 세정에 따른 표면상태도 측정하였다. TXRF 측정결과 split 4가 가장 적은 양의 금속불순물 잔류량을 보였으며 AFM 분석을 통한 표면거칠기도 가장 작은 RMS 값을 나타내었다. Contact angle 측정 결과 UV/ozone 처리는 친수성 표면을 형성하였고 HF처리는 소수성 표면을 형성하였다.

  • PDF

A Study of the Effects of Split Injection on PM and NOx emission in a Common-Rail DI Diesel Engine (Common-Rail DI Diesel Engine에서 Split Injection이 PM및 NOx 배출에 미치는 영향에 관한 기초 연구)

  • Choi, Jin-Ho;Chung, Jae-Wook;Chang, Dong-Hoon;Lee, Jae-Wook;Chun, Kwang-Min
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.225-230
    • /
    • 2003
  • The major purpose of this study is to find the optimized split injection quantities and dwell angles for PM reduction without increasing NOx. The tests were performed on a Common-Rail DI Diesel Engine to obtain optimum injection timing and duration. In this study, total injection quantities were divided into the ratio of 25-75%, 50-50% and 75-25%. NOx and PM were measured on the condition of the same bsfc by increasing dwell angles. It was found that the split injection reduced NOx with dwell angle increase. For 50_50, 75_25% split injection cases, PM was reduced with 10 to 12(CAD) dwell angles. For 25_75% split injection 33% PM reduction was achieved with 8 to 12(CAD) dwell angles.

  • PDF

Effective adjacent baggage split method of Baggage Position Control System to prevent double loading of baggage

  • Song, Jae-Won;Kim, Dong-Chul
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.3
    • /
    • pp.33-40
    • /
    • 2018
  • In this paper, we propose a method to effectively split the adjacent baggage that is moving on high speed conveyor of airport. The proposed method calculate the Angle Histogram(AH) that inspects background pixels within radius r based on the center point of the adjacent baggage. After that, the adjacent baggage is segmented by finding split angles at the AH. We also improved the split quality of adjoining baggage by repeatedly correcting the center point to correctly split adjacent baggage of asymmetric size. And the calculation time of AH is reduced about 1/3 by using the symmetry property of the circle. Experiments have shown that 93% of all adjacent baggage images are correctly segmented and the proposed method is effective.

Biomechanical Analysis at the Start of Bobsleigh Run in Preparation for the 2018 Pyeongchang Winter Olympics

  • Park, Seungbum;Lee, Kyungdeuk;Kim, Daewoong;Yoo, Junghyeon;Jung, Jaemin;Park, Kyunghwan
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.4
    • /
    • pp.239-245
    • /
    • 2017
  • Objective: The bobsleigh shoes used in the start section are one of the most important equipment for improving the competition. Despite the importance of the start section, there are no shoes that are specific for bobsleigh athletes in Korea and Korean athletes have to wear sprint spike shoes and practice the start instead of wearing bobsleigh shoes. The objective of the present study was to provide data for improving the performance of Korean bobsleigh athletes by investigating the differences in their split time, plantar pressure, and forefoot bending angle based on skill levels at the start of a run under the same conditions as training conditions. Method: Six Korean bobsleigh athletes were divided into two groups, superior (n=3) and non-superior (n=3). A digital speedometer measured the split time at the start; the Pedar-X system (Novel, Germany) measured plantar pressure. Plantar pressures and split times were measured as the athletes pushed a bobsleigh and sprinted at full speed from the start line to the 10-m mark on the bobsleigh track. An ultra-high-speed camera was used to measure the forefoot bending angle during the start phase. Results: Significant between-group differences were found in split times (p<.000; superior = 2.38 s, non-superior = 2.52 s). The superior group had a larger rearfoot (p<.05) contact area, maximum rearfoot force (p<.01), and a larger change in angles 3 and 4 (p<.05). Conclusion: At the start of a bobsleigh run, proper use of the rearfoot for achieving effective driving force and increasing frictional resistance through a wider frictional force can shorten start time.