• 제목/요약/키워드: Splint

검색결과 334건 처리시간 0.026초

측두하악관절 환자의 전방재위치장치 치료 전후의 임상증상 및 자기공명영상을 이용한 관절원판 변화의 분석 (ANALYSIS OF THE CLINICAL SYMPTOMS AND THE TEMPOROMANDIBULAR JOINT DISK BY MAGNETIC RESONANCE IMAGING AFTER CONSERVATIVE TREATMENT WITH ANTERIOR REPOSITIONING SPLINT)

  • 명신원;박재억
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권2호
    • /
    • pp.136-142
    • /
    • 2006
  • Temporomandibular joint(TMJ) disorders have characteristic clinical findings such as pain, joint sound, and abnormal jaw function. With the rapid progress in TMJ imaging techniques, magnetic resonance imaging(MRI) especially provides the clinician and researcher with the ability to evaluate TMJ disorders(effusion, anterior disk displacement) and the hard and soft tissue of the TMJ. In order to manage the internal derangement of TMJ such as anterior disk displacement, the so-called appliance therapy is commonly used. This technique became the treatment of choice before surgical intervention by many practitioners. The purpose of the present study was to evaluate and determine the efficacy of anterior repositioning splint by means of the change of the position of the disk through pre- and post-treatment MRI. MRI and clinical symptom were carefully recorded in TMJ disorder patients. The relationship between TMJ symptoms such as pain, clicking sound, and disk displacement and effusion in MRI were analyzed. Then, splint therapy was applied for 3 months according to our protocol; at day 1, patients should wear 24 hours, in order to accomodate the splint and then, wearing time is reduced to 12 hours per day for one month. During next 2 months, it is tapered to 8 hours per day according to the evaluation of the clinical symptoms. Post-treatment MRI was obtained after 3 month protocol. This treatment strategy improved the clinical symptoms of TMJ disorder, and effusion and articular disk position showed a significant change. In conclusion, a treatment modality using an anterior repositioning splint therapy is an appropriate method for temporomandibular disorder patients.

Computerized analysis of occlusal contacts in bruxism patients treated with occlusal splint therapy

  • Gumus, Hasan Onder;Kilinc, Halil Ibrahim;Tuna, Suleyman Hakan;Ozcan, Nihal
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.256-261
    • /
    • 2013
  • PURPOSE. Occlusal splints are commonly used to prevent tooth wear caused by bruxism. However, the effects of splints on occlusion are still unclear. Although it is rarely alluded in literature, splints can provoke severe occlusal alterations and other complications. This study was aimed to identify differences in the responses of individuals with bruxism and healthy individuals to a full-arch maxillary stabilization splint in terms of occlusal changes. MATERIALS AND METHODS. Occlusal contacts in 20 (5 male, 15 female) bruxism patients and 20 (5 male, 15 female) controls with normal occlusion were evaluated before and after occlusal splint therapy. T-Scan III, a computerized occlusal analysis system, was used to simultaneously measure occlusion and disclusion times as well as left-right and anterior-posterior contact distributions before splint therapy and 3 months after therapy. Wilcoxon and Mann-Whitney U tests were used for statistical analyses (${\alpha}$=.05). RESULTS. No differences were found in the posterior contact of bruxism patients before and after stabilization splint treatment. However, differences in posterior contact were observed between bruxists and normal individuals prior to treatment, and this difference disappeared following treatment. CONCLUSION. The results of this study showed the use of a stabilization splint may not have an effect on occlusion. However, the area of posterior occlusal contact among bruxists was found to be greater than that of normal individuals. According to this study, the clinical use of splints may be harmless.

부목과 목발을 이용한 보행이 20대 여성의 에너지대사량에 미치는 영향 (Affect of gait with splint and crutch has on basal metabolism young women)

  • 이지연;박정서;이대희;한슬기
    • 한국산학기술학회논문지
    • /
    • 제12권9호
    • /
    • pp.4001-4007
    • /
    • 2011
  • 본 연구는 부목과 목발을 이용한 보행 시 에너지 소모 정도를 알아보고자 건강한 20대 여성 10명을 대상으로 4주간 정상보행, 부목보행, 부목 목발보행 시 각각의 운동강도, 환기량, 산소소모량, 호흡교환율, 칼로리 그리고 환기당량을 측정하였다. 부목의 무게는 평균 1.2 kg이었으며, 보행은 연구대상자들이 부목을 착용하고 가장 편안하다 고 느낀 2.74 km/h의 속도로 30분간 실시하였다. 실험결과 부목 목발보행이 정상보행과 부목보행에 비해 운동강도가 높았으며, 환기량과 산소소모량에서도 부목 목발보행이 정상보행과 부목보행에 비해 더 많았고 통계학적으로도 유의 하였다(p<0.05). 칼로리는 부목 목발보행이 정상보행과 부목보행에 비해 더 높았으나 통계학적으로 유의하지 않았으며, 호흡교환율과 환기당량에서도 세 조건 간에 통계학적으로 유의한 차이가 없었다.

3D 프린팅을 사용해 제작한 새로운 손 보조기 적용 사례연구 (A case study on the application of new hand splint using 3D printing)

  • 신수정;안조근;박경영
    • 융합정보논문지
    • /
    • 제7권2호
    • /
    • pp.25-29
    • /
    • 2017
  • 본 연구의 목적은 손을 기능적 자세로 만들어주는 새로운 디자인의 보조기를 환자에게 적용하여 손기능에 어떠한 영향을 주는지 알아보고자 하는 것이었다. 새로운 보조기는 엄지와 검지의 샅공간(web space)을 넓히는 새로운 디자인이다. 보조기 착용 후 환자는 엄지 벌림의 자세를 유지할 수 있었고 작은 물건 잡기가 가능하게 되었다. 환자는 손 기능에서 향상을 보였고 Box and Block 검사의 수행이 가능해져 1분에 8개의 블록을 옮길 수 있게 되었다. 그러나 물건에 손바닥의 접촉이 요구는 잡기는 이전보다 더 어려웠고 일상에서 착용시 물이 닿으면 고정되지 못한다는 단점 또한 있었다. 본 연구는 3D 프린팅을 이용한 첫 보조기 적용 연구라는 점에서 의미가 있으며 앞으로 작업치료분야에서 3D 프린팅을 통해 다양한 환자 맞춤형 보조기가 개발될 수 있을 것이라 기대한다.

사용자의 요구조건을 반영 할 수 있는 디자인 가이드라인을 이용한 손가락 보조기 디자인 제안 - FDM 방식의 3D 프린팅 기술을 이용하여 - (Proposal of finger splint design using design guidelines to reflect user requirements - Using FDM 3D printing technology -)

  • 신이열;오광명
    • 디자인융복합연구
    • /
    • 제18권3호
    • /
    • pp.1-14
    • /
    • 2019
  • 국내에서 제작되고 판매되는 일반적인 손가락 보조기는 신체 기관의 손상으로 장애를 가지는 환자에게 많은 도움을 줄 수 있다. 하지만 보조기의 착용은 감추고 싶은 착용자의 장애를 환기시키는 계기가 된다. 그리고 착용자의 심리적 측면에서 자괴감, 우울함 등의 부정적인 영향을 끼친다. 착용자가 착용을 꺼리거나 거부하게 된다면, 보조기는 재활의 역할을 상실하게 된다. 본 연구에서는 사용자의 요구조건을 잘 반영할 수 있는 3D프린터를 이용한 제작방식을 채택하였다. 다음으로 본 연구는 기존 선행연구들을 조사하여 각각의 연구들이 가지는 특징과 기준을 확인하였다. 또한, 현재, 보조기 시장에서 판매되고 있는 의료용 손가락 보조기를 조사하고 각각의 보조기의 사용자 조사를 종합 및 해석하여 평가 기준을 도출하였다. 도출된 평가 기준을 토대로 FDM 방식의 3D프린터를 이용하여 손가락 보조기 제작을 위한 디자인 가이드라인을 제시하였다. 마지막으로, 제시한 디자인 가이드라인에 맞추어 손가락보조기 디자인을 제안하였다.

교합균형이 자세 중심(重心)에 미치는 영향에 관한 연구 (Effect of occlusal balance on center of gravity in body)

  • 이윤;최대균;이성복
    • 구강회복응용과학지
    • /
    • 제19권2호
    • /
    • pp.57-67
    • /
    • 2003
  • Suppose that dental occlusion is related to body posture. We want to find out that improving occlusal balance may affect vibration and distribution of C.O.P. in which way, by measuring change of posture and center of gravity (center of pressure, C.O.P.) which plays important role in measuring balance sensation. Total 11 students at Kyung Hee dental college students, 4 females and 9 males (age: 23-30) participated in this test, who have normal occlusion (Angle's classification I), no TMJ problems. All of the participants have no tooth loss except 3rd molar, no prosthesis over single tooth restoration, no orthopedic problems which affect balance sensation, and no otorhinolaryngological problems. First, we registrated bite by centric relation, and then fabricated stabilization splint that is increased 3.5mm vertical dimension around premolar region. By F-scan (Tekscan Inc., Boston, Mass), we measured discrepancy of average contact pressure of left and right foot. And we also measured discrepancy of vibration of C.O.P(center of pressure). before setting stabilization splint and after wearing stabilization splint at intervals of 1 week, 2 weeks, 3 weeks after. In normal human beings, improved occlusal balance by stabilization splint leads to decrease of vibration of C.O.P. (P<0.05). One week after wearing stabilization splint, vibration of C.O.P. decreased reliably (P<0.05), two weeks after wearing stabilization splint, vibration of C.O.P. decreased similarly comparing to before wearing and one week after wearing. (P<0.05) After two weeks and three weeks, however, it was hard to find reliability. (P>0.05) Difference between average contact pressure of right and left foot also decreased. (P<0.05) We could find decrease after one week of wearing stabilization splint (P<0.05) and two weeks after, the decrease was more reliable than one week after. (P<0.05) After two weeks and three weeks, however, it was hard to find reliability. Improvement of occlusal balance leads to decrease of vibration of C.O.P. and decrease of difference between right and left average contact pressure.

교합고경의 인위적인 증가에 따른 저작계의 반응에 관한 연구 (THE STUDY ABOUT THE CHANGES OF MASTICATORY SYSTEM SUBSEQUENT TO RANDOMLY INCREASING THE VERTICAL DIMENSION)

  • 김남중;이성복;최대균;박남수
    • 대한치과보철학회지
    • /
    • 제33권4호
    • /
    • pp.731-752
    • /
    • 1995
  • This study was performed to research the changes of masticatory system subsequent to randomly increasing the vertical dimension. The subjects were twenty seven persons, twenty two men and five women, with a mean age of 24.3(age ranged from 22 to 26). The subjects had a complete or almost complete set of natural teeth and reported no subjected symptoms of pain or dysfunction in the masticatory system. The occlusal splint increased vertical dimension was made on semiadjustable articulator. The subjects were randomly divided to three groups according to the vertical dimension, at which the occlusal splint was made. Group I occlusal splints were made at 2mm form the occlusal vertical dimension, group II occlusal splints at 5mm, group III occlusal splints at 8mm. The occlusal splints were almost weared for 2 weeks except meal-time. Clinical examination, muscle activity, changes of free-way space, movement of mandible and articular condyle were recorded and analyzed by means of biopak system(Bioresearch Inc, Millwakee Wisconsin.) and radiograph. 1. In clinical examination, various symptoms were reported by all subjects immediately after the placement of occlusal splint. At the end of experiment, symptoms were lasted by 1 subject in Group I, 2 subjects in Group II, 6 subjects in Group III. At the other subjects, the most of symptoms were disappered within 2-4 days after the placement of occlusal splints. 2. The average free-way space before the startof experiment was 1.77mm in all twenty seven subjects. Immediately after the placement of occlusal splints, 0.67mm at Group I, 0.49mm at Group II, 0.41mm at Group III, At 2 weeks after the placement of occlusal splint 0.93mm, 0.79mm, 0.78mm each other, 1.94mm, 1.77mm, 2.3 mm at immediately after the removal of occlual splint. At 1 week after the removal of occlusal splint, free-way space was recovered to the pre-experimental state 3. In cephalometric radiograph, following either the placement or the removal of the occlusal splints, the movements of mandible in an antero-posterior direction were not statistically significant(p>0.05). 4. In transcranial radiograghs of TMJ, 1 week after the placement of occlusal splint the movement of most superior position on condyle in all group shoed antero-inferior position than before the experiment(p<0.001) and also showed antero-inferior position in mandibular postural rest position than in certric occlusion(p<0.001). Following either the placement or the removal of the splints, the amount of movement of most superior position on condyle was group III. group II and group I in order(p<0.001). 5. In anterior temporal and superficial masseter muscle, muscle activity at postural rest position decreased at 2 weeks after the placement of occlusal splint in group I and group II (p>0.05), but significantly increased in group III(p<0.001). At 1 week after the removal of the occdusal splint, muscle activity at postural rest position was recovered preconditional state 6. In anterior temporal and superficail masseter muscle, muscle activity at clenching in all group was significantly decreased after placement of the occlusal splint, slightly increased during experimental period and recovered to the original state at 1 week after removal of the occlusal splint. But was not statistically significat(p>0.05)s.

  • PDF

Resin-Bonded Splint와 직접 복합레진 비니어를 이용한 전치의 심미적 수복

  • 김현경;조영곤
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2002년도 춘계학술대회
    • /
    • pp.318-319
    • /
    • 2002
  • 심미적으로 고안된 resin-bonded splint와 직접 복합레진 비니어 수복의 병행은 심한 치주질환으로 인한 심미적인 불편감과 기능적인 문제를 호소하는 증례에서 적절히 사용된다면, 치아의 심미성과 기능성을 다소 해결재 줄 수 있는 방법으로 고려할 수 있을 것이다.

  • PDF

유리 섬유 의치상 레진 강화재와 열 순환이 의치상 굽힘 강도에 미치는 영향 (The Effect of Glass Fiber Reinforcing Materials and Thermocycling on the Transverse Strength of Denture Base Resin)

  • 진성은;조인호
    • 구강회복응용과학지
    • /
    • 제29권4호
    • /
    • pp.327-336
    • /
    • 2013
  • 본 연구에서는 두 종류의 유리 섬유 의치상 강화재인 Quarts Splint$^{TM}$Mesh와 SES MESH$^{(R)}$의 의치상 보강 효과와 열 순환이 의치상의 굽힘 강도와 강화재의 강화 효과에 미치는 영향을 알아보고자 하였다. 시편은 $2.5{\times}10.0{\times}65.0mm$ 크기로 강화재를 사용하지 않은 대조군, 금속 격자 강화재, Splint$^{TM}$Mesh, SES MESH$^{(R)}$로 보강한 시편을 각각 20개씩 제작하였으며 그 중 10개에는 열 순환을 시행하였다. 3점 굽힘 실험을 시행하여 의치상의 굽힘 강도를 측정하였다. Quarts Splint$^{TM}$Mesh와 SES MESH$^{(R)}$로 강화한 군은 대조군보다 유의하게 높은 굽힘 강도를 나타내었으며(P<.05), 금속 격자 강화재로 보강한 군보다 유의하게 낮은 굽힘 강도를 나타내었다(P<.05). 모든 군에서 열 순환을 시행한 경우가 열 순환을 시행하지 않은 경우에 비해 낮은 굽힘 강도를 나타내었지만 대조군에서만 유의한 차이를 나타내었다(P<.05).