• Title/Summary/Keyword: Spiral test

Search Result 195, Processing Time 0.022 seconds

The Fluidity and Hardness of the Recycled Thermoplastic Elastomer in the Injection Molding process (엘라스토머 재생재의 사출성형시 유동성과 경도)

  • Noh, Byeong-Su;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.1 no.1
    • /
    • pp.39-44
    • /
    • 2007
  • In recent, recycling of plastic material has became a major issue due to the landfills and environmental problem. This study investigated fluidity and hardness of thermoplastic vulcanizate(TPV), which is used for automobile component parts such as weather strip in order to replace ethylene propylene rubber (EPDM). So, using the spiral flow test mold, we conducted an experiment on fluidity and hardness of TPV according to injection molding conditions. As results of injection molding experiment, the recycled TPV's flow length was a little bit longer than virgin TPV and the hardness was decreased in case of using the recycled resin. Also, we investigated the morphology study by SEM photo.

  • PDF

An Experimental Study on Seismic Performance of RC Bridge Columns with Interlocking spirals and Interlocking circular hoops (결합나선철근 및 결합원형띠철근 교각의 내진성능에 관한 실험적 연구)

  • 고성현;이재훈;서진원;이지영;손혁수;최진호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.943-948
    • /
    • 2003
  • The experimental study for oblong section was carried out by the column test in weak axis. The column specimens had 3 types of transverse steel configurations, such as interlocking spirals, interlocking circular hoop ties and rectangular ties. The oblong columns with interlocking spirals and with interlocking circular hoop ties showed better seismic performance than the rectangular columns with rectangular hoops and cross-ties. The objectives of this study were to provide experimental data on the behavior of interlocking spiral columns under cyclic loading, to compare the performance of columns with interlocking spirals to columns with various transverse steel configurations, to study the flexural detailing of interlocking spirals, interlocking circular hoops, and other transverse steel configurations as the transverse reinforcement, and to make recommendations for the design of bridge columns incorporating interlocking spirals, circular hoops as the transverse reinforcement.

  • PDF

PD Measurement in oil with defects (결함별 절연유중 부분방전 측정 연구)

  • Sun, J.H.;Yi, S.H.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.67-69
    • /
    • 2004
  • Since partial discharges in power transformers weaken their insulation performance the detection of partial discharge is very important for prevention of fatal incidents. This study describes use of electromagnetic coupler for measurement of partial discharge of transformers. Spiral antennas of which bandwidth is 0.5GHz to 3GHz were used as coupler and setup in chamber for partial discharge tests. Test results showed that outputamplitudes are increased with PD increase and frequencies of signal measured by these antennas are mostly distributed below about 800MHz.

  • PDF

A Study about Micro Mold for Polymer Injection (고분자소재 성형용 마이크로 금형에 관한 연구)

  • Heo Y. M.;Shin K. H.;Yoon G. S.;Jung W. C.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.10a
    • /
    • pp.271-275
    • /
    • 2004
  • In recent industry, according to pursuit the miniaturization and high-precision of machine part with development of new technology as IT and BT, the development of mold manufacturing technology for mass production is accompanied. This study proposes the design of micro mold-base, predicts the error of product through estimating transformation of injection process using FEM. Therefore the mold-base which is suitable for micro injection proposed in this study. Finally, the error of feature is analyzed by measuring the manufactured micro mold-base.

  • PDF

A Study on Heat Transfer Performance of Horizontal Ground Heat Exchanger (수평형 지중열교환기의 열전달 성능에 관한 연구)

  • Chung Minho;Park Seongryong;Ra Hosang;Baik Youngjin;Yoon Hyungkee;Chang Kichang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.684-687
    • /
    • 2005
  • Ground source heat pump systems are used for heating, ventilating and air-conditioning systems in commercial buildings, schools, and factories because of low operating and maintenance costs. These systems use the earth as a heat source in heating mode and a heat sink in cooling mode. Ground heat exchangers are classified by a horizontal type and vertical type according to the installation method. A horizontal type means that a heat exchanger is laid in the trench bored in 1.2 to 1.8 m depth. The solar heat and the rainwater are affected by the performance of heat exchanger and causes mutual influence among heat exchangers. In this study, to evaluate the performance of straight type, slinky type, and spiral type of horizontal ground heat exchangers designed on 1 RT scale, test sections are buried on the earth and experimental apparatus is installed. Therefore the performance of these is estimated.

  • PDF

Simulation on the Corona Characteristics of Low Aeolian Noise Conductor Bundles for 765 kV Transmission Line (765kV 송전선로용 저풍소음 복도체 방식의 코로나 특성 모의실험)

  • Ju, M.N.;Yang, K.H.;Shin, K.Y.;Lee, D.I.;Min, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.131-133
    • /
    • 2000
  • Single phase simulations were carried out in order to determine a solutive conductor to the aeolian noise which will be locally applied to 765 kV transmission lines Basic solutive conductors have already been proposed including conductors equipped with spiral rod. low noise conductor of a special shape and others. A low aeolian noise conductor, however, should have excellent corona characteristics in addition to aeolian noise reduction function. In this paper, we compared the performances of the audible noises and radio interferences of 6 candidate conductor bundles by using corona cage. We also developed two programs to need for evaluating environmental effects of each conductor bundle. Those are a program to calculate the conductor surface gradient of various special bundles and a conversion program of single phase data to the model of transmission line. The future determination on the final low aeolian noise conductor will be made through a long-term test to verify environmental impacts at the full-scale Kochang 765 kV test line.

  • PDF

Effect of Air Admission on Pressure Pulsation in a Francis Turbine (급기가 프란시스 수차의 수압 맥동에 미치는 영향)

  • Jeon, Yunheung;Park, Sihoon;Choi, Hansu;Park, Jungwan
    • New & Renewable Energy
    • /
    • v.10 no.4
    • /
    • pp.9-15
    • /
    • 2014
  • In this study pressure and shaft torque pulsation were measured with variation of head and flow during the model test for a 15 MW Francis Turbine. Pressure pulsations were measured at the inlet of the spiral casing and 4 points in the cone of the diffuser and shaft torque pulsation at the upper position of the turbine. The maximum amplitude of pressure pulsation appeared 2.03% of the maximum rated head with the frequency of 25% of the rated revolution and at the guide vane opening of $10^{\circ}$. Shaft torque pulsation appeared 0.01% of the rated shaft torque, fairly low value. Air was admitted through the cone and pressure pulsation gradually decreased with increase of air flow and kept nearly constant after 5% of the rated flow. A new Francis turbine of which specific speed is 115 m-kW had been designed to rehabilitate the old one and the model test was performed at EPFL. The commercial code, STAR-$CCM^+$ was used for numerical simulation of flow.

Design of a Free Bulge Test Coil Using Electromagnetic Forces and Comparison between Experimental and Numerical Results (전자기력 자유벌지 실험을 위한 성형코일 설계 및 3-D 해석비교)

  • Kim, H.K.;Noh, H.G.;Kang, B.S.;Kim, J.
    • Transactions of Materials Processing
    • /
    • v.23 no.7
    • /
    • pp.431-438
    • /
    • 2014
  • For electromagnetic forming(EMF) the most important feature is a forming coil which creates the electromagnetic force(Lorentz force), using current density and a magnetic field. Most previous papers have concentrated on the final configuration of the blank or the efficiency of EMF process. Studies focused on the design parameters affected by the forming coil performance have not been conducted. In order to design a suitable forming coil for an object, the current study uses LS-DYNA EM-Module to not only optimize the coil but also to examine the effect of coil performance. By this method a suitable forming coil was made and tested to determine whether or not good formability was achieved in a free bulge test Numerical analysis was also used. The workpiece was Al 1100-O with a thickness of 1.27mm and the coil was made from copper CW004A, which has good electrical conductivity and is suitable for electrical components.

On the Analytical Model of Automotive Steering Hoses Containing Tuner and Its Practical Application (튜너 내장 자동차 조향호스의 해석 모델과 실용적 응용)

  • Lee, J.C.;Oh, S.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • This study presents an analytical model of an automotive steering hose containing tuner(flexible spiral metal tube) to reduce the ripple pressure induced by steering vane pump. The double-wall side branch composed in a steering hose containing tuner was analogically considered as a filter in a conduit. Specialized test equipment was manufactured for the estimation of speed of sound in a conduit and measurement of amplitude ratio between the propagated ripple pressures of inlet and outlet of the steering hose. Experimental data of entire frequency ranges can be obtained through the test once in short time. The results of three points' measurement method and cross-correlation method to estimate the speeds of sound in a hose, tuner, and side branch respectively reveal that cross-correlation method can be used practically. The results of simulation and experiment were so close, especially in the range of engine idling speed, that the proposed analytical model in this study was validated. Sensitivity analyses and experiments show that longer tuner is preferable, and that the positive-positive composition of the steering hoses containing tuner is superior to others to attenuate ripple pressure.

  • PDF

Experimental study on two types of new beam-to-column connections

  • Ma, Hongwei;Jiang, Weishan;Cho, Chongdu
    • Steel and Composite Structures
    • /
    • v.11 no.4
    • /
    • pp.291-305
    • /
    • 2011
  • The new structure consisting of continuous compound spiral hoop reinforced concrete (CCSHRC)column and steel concrete composite (SCC) beam has both the advantages of steel structures and concrete structures. Two types of beam-to-column connections applied in this structural system are presented in this paper. The connection details are as follows: the main bars in beam concrete pass through the core zone for both types of connections. For connecting bar connection, the steel I-beam webs are connected by bolts to a steel plate passing through the joint while the top and bottom flanges of the beams are connected by four straight and two X-shaped bars. For bolted end-plate connection, the steel I-beam webs are connected by stiffened extended end-plates and eight long shank bolts passing through the core zone. In order to study the seismic behaviour and failure mechanisms of the connections, quasi-static tests were conducted on both types of full-scale connection subassemblies and core zone specimens. The load-drift hysteresis loops show a plateau for the connecting bar connection while they are excellent plump for bolted end-plate connection. The shear capacity formulas of both types of connections are presented and the values calculated by the formula agree well with the test results.