• 제목/요약/키워드: Spiral imaging

검색결과 90건 처리시간 0.023초

뇌전산화단층검사에서 방사선량 저감을 위한 최적화 프로토콜 연구 (Optimization of Brain Computed Tomography Protocols to Radiation Dose Reduction)

  • 이재승;권대철
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권3호
    • /
    • pp.116-123
    • /
    • 2018
  • This study is a model experimental study using a phantom to propose an optimized brain CT scan protocol that can reduce the radiation dose of a patient and remain quality of image. We investigate the CT scan parameters of brain CT in clinical medical institutions and to measure the important parameters that determine the quality of CT images. We used 52 multislice spiral CT (SOMATOM Definition AS+, Siemens Healthcare, Germany). The scan parameters were tube voltage (kVp), tube current (mAs), scan time, slice thickness, pitch, and scan field of view (SFOV) directly related to the patient's exposure dose. The CT dose indicators were CTDIvol and DLP. The CT images were obtained while increasing the imaging conditions constantly from the phantom limit value (Q1) to the maximum value (Q4) for AAPM CT performance evaluation. And statistics analyzed with Pearson's correlation coefficients. The result of tube voltage that the increase in tube voltage proportionally increases the variation range of the CT number. And similar results were obtained in the qualitative evaluation of the CT image compared to the tube voltage of 120 kVp, which was applied clinically at 100 kVp. Also, the scan conditions were appropriate in the tube current range of 250 mAs to 350 mAs when the tube voltage was 100 kVp. Therefore, by applying the proposed brain CT scanning parameters can be reduced the radiation dose of the patient while maintaining quality of image.

전산화단층촬영 단말장치와 개인용 컴퓨터에서 재구성한 두부 3차원 전산화단층영상의 비교 (Comparison of personal computer with CT workstation in the evaluation of 3-dimensional CT image of the skull)

  • 강복희;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제31권1호
    • /
    • pp.1-7
    • /
    • 2001
  • Purpose : To evaluate the usefulness of the reconstructed 3-dimensional image on the personal computer in comparison with that of the CT workstation by quantitative comparison and analysis. Materials and Methods : The spiral CT data obtained from 27 persons were transferred from the CT workstation to a personal computer, and they were reconstructed as 3-dimensional image on the personal computer using V-works 2.0/sup TM/. One observer obtained the 14 measurements on the reconstructed 3-dimensional image on both the CT workstation and the personal computer. Paired Nest was used to evaluate the intraobserver difference and the mean value of the each measurement on the CT workstation and the personal computer. Pearson correlation analysis and % incongruence were also performed. Results: I-Gn, N-Gn, N-A, N-Ns, B-A, and G-Op did not show any statistically significant difference (p>0.05), B-O, B-N, Eu-Eu, Zy-Zy, Biw, D-D, Orbrd R, and L had statistically significant difference (p<0.05), but the mean values of the differences of all measurements were below 2 mm, except for D-D. The value of correlation coefficient y was greater than 0.95 at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and it was 0.75 at B-O, 0.78 at D-D, and 0.82 at both Orbrd Rand L. The % incongruence was below 4% at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and 7.18%, 10.78%, 4.97%, 5.89% at B-O, D-D, Orbrd Rand L respectively. Conclusion : It can be considered that the utilization of the personal computer has great usefulness in reconstruction of the 3-dimensional image when it comes to the economics, accessibility and convenience, except for thin bones and the landmarks which are difficult to be located.

  • PDF

Molecular gas and star formation in early-type galaxies

  • Bureau, Martin
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.65-65
    • /
    • 2011
  • Early-type galaxies represent the end point of galaxy evolution and, despite pervasive residual star formation, are generally considered "red and dead", that is composed exclusively of old stars with no star formation. Here, their molecular gas content is constrained and discussed in relation to their evolution, supporting the continuing importance of minor mergers and/or cold gas accretion. First, as part of the Atlas3D survey, the first complete, large, volume-limited survey of CO in normal early-type galaxies is presented. At least of 23% of local early-types possess a substantial amount of molecular gas, the necessary ingredient for star formation, independent of mass and environment but dependent on the specific stellar angular momentum. Second, using CO synthesis imaging, the extent of the molecular gas is constrained and a variety of morphologies is revealed. The kinematics of the molecular gas and stars are often misaligned, implying an external gas origin in over a third of all systems, more than half in the field, while external gas accretion must be shot down in clusters. Third, many objects appear to be in the process of forming regular kpc-size decoupled disks, and a star formation sequence can be sketched by piecing together multi-wavelength information on the molecular gas, current star formation, and young stars. Fourth, early-type galaxies do not seem to systematically obey all our usual prejudices regarding star formation (e.g. Schmidt-Kennicutt law, far infrared-radio continuum correlation), suggesting a greater diversity in star formation processes than observed in disk galaxies and the possibility of "morphological quenching". Lastly, a first step toward constraining the physical properties of the molecular gas is taken, by modeling the line ratios of density- and opacity-sensitive molecules in a few objects. Taken together, these observations argue for the continuing importance of (minor) mergers and cold gas accretion in local early-types, and they provide a much greater understanding of the gas cycle in the galaxies harbouring most of the stellar mass. In the future, better dust masses and dust-to-gas mass ratios from Herschel should allow to place entirely independent constraints on the gas supply, while spatially-resolved high-density molecular gas tracers observed with ALMA will probe the interstellar medium and star formation laws locally in a regime entirely different from that normally probed in spiral galaxies.

  • PDF

전산화단층영상에서 절치관 및 순측 치조골 폭경에 관한 연구 (The width of the incisive canal and labial alveolar bone of the incisive canal: an assessment on CT images)

  • 노양균;장현선;김병옥;김진수
    • Imaging Science in Dentistry
    • /
    • 제36권3호
    • /
    • pp.145-149
    • /
    • 2006
  • Purpose : To assess the width of the labial alveolar bone of the incisive canal and the width of the incisive canal on spiral computed tomographic images of the anterior portion of the maxilla. Materials and Methods : Study materials included 38 CT scans taken for preoperative planning of implant placement. Axial cross-sectioned image entirely showing the incisive canal was selected and scanned with 600 DPI resolution. The width of the labial alveolar bone of the incisive canal at an orifice to the oral cavity, middle portion, and an orifice to the nasal cavity and the diameter of the incisive canal at the middle portion were determined by two specialist using Digora for Windows 2.1 The statistical analyses were carried out using SPSS 12.0.1. Results : When the maxillary central incisors remained, the mean labial alveolar bone width were $6.81{\pm}1.41mm,\;6.46{\pm}1.33mm$, and $7.91{\pm}1.33mm$. When the maxillary central incisors were missed the mean width were $5.42{\pm}2.20mm,\;6.23{\pm}2.29mm$, and $7.89{\pm}2.13mm$. Conclusions : The labial alveolar bone width at middle portion and an orifice to the nasal cavity were of no statistical significant difference according to presence of the maxillary central incisors (P>0.05). The width between oral cavity and nasal cavity, middle portion and to nasal cavity revealed statistically significant difference (P<0.05).

  • PDF

Airway Reactivity to Bronchoconstrictor and Bronchodilator: Assessment Using Thin-Section and Volumetric Three-Dimensional CT

  • Boo-Kyung Han;Jung-Gi Im;Hak Soo Kim;Jin Mo Koo;Hong Dae Kim;Kyung Mo Yeon
    • Korean Journal of Radiology
    • /
    • 제1권3호
    • /
    • pp.127-134
    • /
    • 2000
  • Objective: To determine the extent to which thin-section and volumetric three-dimensional CT can depict airway reactivity to bronchostimulator, and to assess the effect of different airway sizes on the degree of reactivity. Materials and Methods: In eight dogs, thin-section CT scans were obtained before and after the administration of methacholine and ventolin. Cross-sectional areas of bronchi at multiple levels, as shown by axial CT, proximal airway volume as revealed by three-dimensional imaging, and peak airway pressure were measured. The significance of airway change induced by methacholine and ventolin, expressed by percentage changes in cross-sectional area, proximal airway volume, and peak airway pressure was statistically evaluated, as was correlation between the degree of airway reactivity and the area of airways. Results: Cross-sectional areas of the bronchi decreased significantly after the administration of methacholine, and scans obtained after a delay of 5 minutes showed that normalization was insufficient. Ventolin induced a significant increase in cross-sectional areas and an increase in proximal airway volume, while the effect of methacholine on the latter was the opposite. Peak airway pressure increased after the administration of methacholine, and after a 5-minute delay its level was near that of the control state. Ventolin, however, induced no significant decrease. The degree of airway reactivity did not correlate with airway size. Conclusion: Thin-section and volumetric spiral CT with three-dimensional reconstruction can demonstrate airway reactivity to bronchostimulator. The degree of reactivity did not correlate with airway size.

  • PDF

가토에서 VX2 단일간암모델과 CT 소견 (Solitary Hepatic VX2 Tumor Model and Its CT Findings in Rabbits)

  • 이해범;이기창
    • 한국임상수의학회지
    • /
    • 제23권4권
    • /
    • pp.388-392
    • /
    • 2006
  • 80두의 가토 간에 $1{\sim}2mm^3$ 크기의 VX2 종양세포를 직접 주입하여 단일간암모델을 만들고, 종양이식 후1주, 2주, 3주째에 CT촬영을 실시하여 생성된 종양의 크기와 조영 양상을 관찰하고 조직병리학적검사로 종양의 진위 여부를 확인하였다. 80두 중 66두(82.5%)에서 단일 종양이 만들어졌다. 나머지 12두 중 1두에서 간외종앙의 생성, 그리고 다른 1두에서 육아종성 종괴가 관찰되었으며, 4두는 폐사하였다. 나머지 8두에서는 종양이 생성되지 않았다. 조영 CT에서 관찰된 종양의 크기는 1주, 2주 그리고 3주째에 각각 $7.4{\times}6.3,\;14.2{\times}10.8,\;16.2{\times}12.6cm$로 측정되었다. 모양은 둥글거나 타원형이었으며, 동맥기에서 중앙에 저감쇠와 변연에 조영증강을 보였으며, 문맥기에는 저감쇠를 나타내었다. 종양조직의 이식은 균질한 단일종양모델을 만드는데 매우 유용하고 적합한 방법이며, 조영 CT 촬영술은 간종양 진단 및 다양한 치료방법 적용 후 추적검사에 매우 유용하게 활용될 것으로 판단된다.

개에서 다중나선형 CT촬영에 의한 동맥혈전색전증의 평가 (Assessment of Systemic Arterial Thromboembolism with Multi-Slice Spiral CT in a Dog)

  • 신승호;이기창
    • 한국임상수의학회지
    • /
    • 제24권2호
    • /
    • pp.208-213
    • /
    • 2007
  • 호흡곤란과 후지마비 및 발등부위의 괴사를 나타낸 수컷 진돗개가 전북대학교 동물의료센터에 내원하였다. 초기 검사에서 심장 사상충 감염이 확인되었다. 흉부방사선 외측상에서 폐동맥의 확장과 후엽의 간질패턴, 그리고 복배상에서 주 폐동맥의 뚜렷한 확장등이 관찰되어 심장사상충증을 뒷받침하였고, 복부 외측상 및 복배상에서 복부세부음영 소실이 관찰되어 복수를 의심하였다. 초음파상에서 복수와 불규칙한 간변연 그리고 신장양극의 피질에서 쐐기모양의 국소적 고에코상을 관찰하였으며 복부대동맥에서 분지하여 주행하는 바깥장골동맥의 3상형 동맥파형이 분지부 근위에서 관찰되었으나 이 후 대퇴동맥의 파형은 확인되지 않았다. 혈액화학검사에서 백혈구증다증, 빈혈, 혈색소 뇨, 고빌리루빈혈증, 저 알부민혈증, 전해질불균형, 그리고 간장 및 신장효소치의 상승등이 관찰되어 광범위한 장기의 손상이 의심되었다. 특히 글루코스는 정상적인 전지와 마비를 보이는 후지에서 비교한 결과 후지의 글루코스 수치가 현저하게 낮았다. 전산화단층촬영술 후 3차원으로 재구성한 영상을 이용하여 후지 마비의 원인으로 여겨지는 후지 동맥의 혈전색전증과 폐동맥혈전색전증 및 신장경색 등을 확인하였다. 예후불량으로 판단되었으며 실험적 중재적 방사선술을 시도하였으나 마취에서 깨어나지 못했다. 3차원 재구성 CT 영상은 색전증의 빠르고 정확한 진단에 유용하며 효과적인 치료 계획을 수립하는데도 큰 도움이 된다고 판단된다.

파라미터의 변경에 따라 나선형 전산화 단층 촬영의 체적 변화 (Volume Change of Spiral Computed Tomography due to the Changed in the Parameters)

  • 이준행
    • 한국방사선학회논문지
    • /
    • 제7권4호
    • /
    • pp.307-311
    • /
    • 2013
  • 본 논문에서는 피폭선량 절감을 위해 기존의 선량보다 낮은 선량으로 CT검사를 했을 경우에 병변의 유무를 충분히 가릴 수 있는지 scan parameter(절편두께, Helical Pitch)와 3차원으로 영상재구성시 threshold값의 설정에 따른 영상의 변화정도를 3차원 영상화를 통하여 시료의 체적 변화를 알아보고, 피폭선량절감을 위한 CT에서 허용 가능한 scan parameter를 찾고자 연구를 시도하였다. 실험방법으로는 실리콘을 이용하여 시료를 제작하였으며, 이때 시료의 크기는 직경이 50, 40, 30, 20, 10mm로 10mm 간격으로 5개의 구형 모형을 제작하였고, 5개의 시료를 관전압, 관전류를 각각 120Kvp, 50mA로 고정하고, 단면두께(1.0, 2.0, 3.0, 5.0, 7.0mm), Helical Pitch(1.5, 2.0, 3.0)를 각각 변화시켜 Scan 하고 영상 간의 interval은 (1.0, 2.0, 3.0, 5.0, 7.0mm)로 구성하여, 영상을 workstation으로 전송하고, Volume Rendering Technique를 사용하여 threshold(-200,-50,50 ~1,000) 값을 변화시키면서 3차원 영상으로 재구성하고, 시료의 체적을 측정하였다. 실험결과 Helical pitch가 1.5일 때 체적변화가 가장 적었고, Helical pitch가 3.0일 때 체적변화가 가장 많이 감소하였으며, 절편두께가 증가할수록 시료의 체적도 실측치보다 감소한다는 것을 실험을 통해 확인 할 수 있었다. 또한 3차원 영상재구성시 threshold 범위를 -200~1,000으로 설정한 경우, 시료의 체적의 변화가 가장 적은 것으로 나타났다.

직장암 병기결정에서 직장 CT의 진단능: 직장 MRI 및 병리결과와의 비교분석 (Diagnostic Performance of Rectal CT for Staging Rectal Cancer: Comparison with Rectal MRI and Histopathology)

  • 손석윤;서윤석;윤정희;허보윤;배재석;김세형
    • 대한영상의학회지
    • /
    • 제84권6호
    • /
    • pp.1290-1308
    • /
    • 2023
  • 목적 직장암 병기결정에서 직장 CT의 진단능을 고해상도 직장 MRI 및 병리결과와 비교분석 하였다. 대상과 방법 초음파 젤을 이용하여 직장을 팽창시킨 후 얻은 직장 CT와 고해상도 직장 MRI를 촬영한 66명의 직장암 환자가 포함되었다. 두 명의 위장관 영상의학과 의사가 직장 CT와 MRI에서 항문피부선/항문직장경계까지의 거리, 직장간막근막까지의 거리, 벽외침범 깊이, 직장간막외 림프절 침범, 벽외정맥침범, 및 T/N 병기를 평가하였다. 동시화학방사선요법을 시행 받지 않고 근치적 수술을 시행한 20명의 환자의 CT 소견을 병리결과와 비교하였다. 급내상관분석 및 카파 분석을 이용하여 통계 분석하였다. 결과 항문피부선/항문직장경계까지의 거리 측정에서 두 명의 영상의학과 의사 모두 CT와 MRI 간에 높은 상관관계를 보였다. 벽외침범 깊이, 직장간막근막까지의 거리, 림프절의 유무, 직장간막외 림프절 침범, 벽외정맥침범, T 병기 결정에서 CT와 MRI 간의 높은 일치도를 보였다. 수술을 시행받은 20명의 환자에서 T 병기, 측방절제연 침범, 벽외정맥침범, 림프절 전이 결정에서 CT는 병리결과와 만족할만한 일치율을 보였다. 결론 직장암 전용 CT는 직장암 환자의 병기 결정에 중요한 정보를 제공하며, 진단능은 고해상도 직장 MRI와 유사하다.

비글과 시츄견에서 호기말 양압에 따른 전산화 단층촬영상의 폐밀도의 평가 (Assessment of Computed Tomographic Lung Density in Beagle and Shihtzu Dogs : Influence of Position and Positive End Expiratory Pressure)

  • 김태훈;장진화;윤석주;윤정희;장동우
    • 한국임상수의학회지
    • /
    • 제27권3호
    • /
    • pp.273-283
    • /
    • 2010
  • 이 연구의 목적은 정상폐의 의존적 부위와 비의존적 부위에서 중력과 호흡이 폐밀도에 어떤 영향을 미치는지 그리고 폐첨부, 중부, 기저부의 부위별 밀도 차이가 어떻게 존재하며 호기말 양압에 따른 폐실질의 변화상을 알아보고 흉부 전산화 단층촬영에서 호기말 양압과 중력에 의해 가장 영향을 적게 받는 최적의 자세와 압력을 결정하고자 한다. 비글 8마리와 시츄 8마리에서 자발 호흡을 억제시킨 상태에서 호기말양압을 0 mmHg, 10 mmHg, 20 mmHg를 가하여 배측 횡와 자세와 복측 횡와 자세, 좌 우측 횡와자세에서 전산화 단층 촬영을 실시하였다. 폐의 첨부와 중부기저부 (각각 대동맥궁, 기관 분기부, 횡격막 직상방) 세부위의 슬라이스를 선택하였다. 스캔한 세 부위에서 대혈관은 포함시키지 않고 흉벽에서 5 mm 떨어진 폐 주변부에서 전부, 후부, 측부 세 곳을 정하여 50 mm2 면적을 갖는 원형의 관심영역을 설정한 후 그 면적의 밀도를 측정하였다. 폐밀도는 품종과 자세, 호기말 양압에 상관없이 호기말 양압이 0 mmHg, 10 mmHg에서 중력방향에 영향을 받은 폐의 의존적인 부분이 비의존적인 부분보다 더 높게 측정이 되었으나 호기말 양압이 20 mmHg일때는 시츄견의 배측 횡와 자세를 제외하고는 폐밀도에 차이가 없었다. 4가지 자세 모두에서 폐의 첨부의 폐밀도가 폐의 기저부 보다 더 높게 측정이 되었으며 압력이 증가함에 따라 동일부위에서 측정한 폐밀도는 감소하는 경향으로 관찰되었다. 같은 압력과 같은 자세에서 폐의 첨부와 중부, 기저부의 슬라이스에서 전부, 후부, 측부를 비교 평가한 결과에서는 비글과 시츄견 모두에서 복측 횡와 자세와 좌 우측으로 횡와한 자세, 20 mmHg에서 폐밀도간에 차이가 없는 것으로 확인되었다. 따라서 흉부 전산화 단층촬영을 위한 최적의 자세와 호기말 양압은 비글과 시츄견 모두에서 복측 횡와 자세와 좌 우측으로 횡와한 자세 와 20 mmHg로 확인되었으며 이러한 결과들을 바탕으로 폐질환이 의심되는 동물에 있어서 전산화 단층 촬영상 판독을 위한 기초 자료를 구축할 수 있었다.