An Outlook on the Draft-Tube-Surge Study

  • Nishi, Michihiro;Liu, Shuhong
    • International Journal of Fluid Machinery and Systems
    • /
    • 제6권1호
    • /
    • pp.33-48
    • /
    • 2013
  • If large pressure fluctuation is observed in the draft tube of a Francis turbine at part-load operation, we have generally called it draft-tube-surge. As occurrence of this phenomenon seriously affects the limit of turbine operating range, extensive studies on the surge have been made since proposal of surge-frequency criterion given by Rheingans. According to the literature survey of related topics in recent IAHR symposiums on hydraulic machinery and systems, in which state-of-the-art contributions were mainly presented, a certain review of them may be desirable for an outlook on the future studies in this research field. Thus, in this review paper, the authors' previous attempts for the last three decades to challenge the following topics: a rational method for component test of a draft tube, nature of spiral vortex rope and its behavior in a draft tube and cavitation characteristics of pressure fluctuations, are introduced together with other related contributions, expecting that more useful and significant studies will be accomplished in the future.

공기압축기의 인터쿨러 선정을 위한 열교환기의 형상별 성능해석 (Comparison of Various Heat Exchanger Performances in order for Air Compressor Intercooler Application)

  • 유상훈;박상구;윤정필;정지환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권1호
    • /
    • pp.73-81
    • /
    • 2008
  • Intercooling and aftercooling are required in order to operate air compressor, these are conducted through air-cooled or water-cooled heat exchangers. This study aims to find more suitable type of heat exchanger as a water-cooled intercooler of air compressor. Comparative performance evaluation among fin-tube heat exchanger and shell-and-tube (S&T) heat exchanger having various tubes such as circular tube, spiral tube, and internally finned tube was conducted. Thermal-hydraulic performance of each heat exchanger type is evaluated in terms of temperature drop and pressure drop. The comparisons show that shell-and-tube heat exchangers may have similar and larger heat transfer capacity to the fin-tube heat exchanger if tube diameter is reduced and multiple pass is adopted. For these cases, however, compressed air pressure drop in shell-and-tube heat exchanger become much larger than that in fin-tube heat exchanger.

수차에서 발생되는 유체여기진동 저감방안 연구 (A Research for Reducing Methods of Sub-synchronous Vibration in Water Turbines)

  • 박한영;조성수;라병필;김진훈;박종호;이연주
    • 한국유체기계학회 논문집
    • /
    • 제12권5호
    • /
    • pp.13-18
    • /
    • 2009
  • In this paper, it is intended to figure out the features and causes of the processes of creation, growth and disappearance of spiral-vortex-flow generated in Francis turbines generally. The spiral-vortex-flow generated in draft tubes of the Francis turbines is estimated to have negative effects on power plant structure and to the people inside the building as well as to lead to a low-frequency-vibration driven by sub-synchronous whirl vibration. Therefore, we intend to investigate how much the low-frequency-vibration has an influence upon the powerhouse structure and practice analyzing the effectiveness on the previously-introduced methods to reduce side-effects of sub-synchronous whirl vibration and finally we intend to show the optimal solutions through this paper.

Thermal Performance of a Finned-tube Heat Exchanger used in Condensing Gas Boiler

  • Kang, Hie-Chan;Lim, Bok-Bin;Lee, Jung-Man;Kim, Moo-Han
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권2호
    • /
    • pp.61-67
    • /
    • 2009
  • In the present study, an experiment was conducted to investigate the heat and mass transfer performance of heat exchangers used in the condensing gas boiler. Two types of spiral circular fin-tube heat exchangers and a plain tube were tested in the flue gas of propane and dry air. Heat and mass transfer coefficients were measured and compared with the previous correlations. The experimental data for the sensible heat transfer of the plain tube reasonably agreed with the previous correlations for dry air and flue gas. However, the mass transfer coefficient of the plain tube was greater than the previous correlations. The pH, $NO_x$, and $SO_x$ data of condensate were provided.

Furan Foundry Sand 유동층에서 열 전달 특성에 관한 연구 (An Experimental Study on Heat Transfer in the Furan Foundry Sand Fluidized Bed)

  • 박종순;백고길;김은영;전성택;이덕봉
    • 태양에너지
    • /
    • 제15권3호
    • /
    • pp.105-117
    • /
    • 1995
  • 본 연구소에서는 Furan foundry sand 유동층내에 Spiral coil tube를 설치하여 유동입자, 유동층내 온도, 유동율, 전열 관의 Pitch와 직경 비(p/Do) 및 전열 관의 Pitch와 유동입자의 크기의 비(p/dp) 등이 전열 관 표면 열 전달계수(ho)에 미치는 영향을 실험적으로 연구하고, 또한 최대 $Nu_{max}$수를 여러 변수들의 관계로 나타내었다. 전열 관 표면 열 전달계수는 유동층내 온도가 높아 질 수록, 유동율이 커질수록 증가한다. 그러나 유동입자의 크기가 커지면 열 전달계수는 감소한다. 전열 관의 Pitch와 직경 비(p/Do)와의 관계에서 p/Do=4.75일 때 가장 높은 열 전달계수를 얻었으며, 유동층내 온도가 상승하고, Re 수가 증가할 수록 p/Do=1.58일 때보다 p/Do=4.75일때가 Nu수의 증가율은 다소 감소하는 경향을 보였다. 또한 p/dp의 비가 클 경우 낮은 온도($75^{\circ}C$)에서, p/dp의 비가 작을 경우는 높은 온도($550^{\circ}C$)에서 열 전달 효과가 큰 것으로 나타났다. 본 실험범위에서 최대 $Nu_{max}$ 수와 Re 수, Prg 수, p/dp 및 p/Do의 관계를 무차원 식으로 다음과 같이 나타낼 수 있었다. $$Nu_{max}=1.01\;Re^{0.48}Prg^{0.4}(p/dp)^{0.28}(p/Do)^{0.05}$$.

  • PDF

대향류형 보텍스 튜브의 노즐형상 변화011 따른 튜브 내부의 온도분포에 관한 실험적 연구 (An Experimental Study on the Characteristics of Temperature Distribution in Internal Space of a Tube for the Formal Change of Counterflow Type Vortex Tube)

  • 황승식
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.69-76
    • /
    • 2002
  • The aim of this study is to provide fundamental informations that make it possible to use a cool stream and a hot stream simultaneously. We changed the pressure of compressed air that flows into a tube, the inner diameter of orifice that a cold stream exits, and the mass flow rate ratio. And in each case, we measured the temperature of a cold stream and a hot stream in each exit of a tube. Also we measured the axial and the radial temperature distribution in internal spare of a tube. From the study, fellowing conclusive remarks 7an be made. First, As the number of nozzles increase, separation point move into the hot exit. Second, When we use guide vane type nozzle, the axial temperature distribution constant over the 0.75 of air mass flow rate radio. Third, When we use Spiral type nozzle, axial and radial temperature distribution in the inner space is higher than another nozzle. Fourth, Axial and radial temperature distribution in the inner space vortex-tube is determined by separation point. And separation point is moved by changing of air mass flow rate ratio. At last, A heating apparatus is possible far vortex-tube to use.

수평 평활관과 마이크로핀 관내에서 HFC-134a의 응축 및 증발열전달 특성 (Condensation and evaporation heat transfer characteristics of HFC-134a in a horizontal smooth and a micro-finned tube)

  • 이상천;박병덕;한운혁;이재희
    • 대한기계학회논문집B
    • /
    • 제20권5호
    • /
    • pp.1725-1734
    • /
    • 1996
  • Experimental condensation and evaporation heat transfer coefficients were measured in a horizontal smooth tube and a horizontal micro-finned tube with HFC-134a. The test sections are straight, horizontal tubes with have a 9.52mm outside diameter and about 5000mm long. The micro-finned tube had 60 fins with a height of 0.12mm and a spiral angle of 25.deg.. The condensation test section was a double-pipe type with counter flow configuration. The evaporation test section employed an electic heating method. Enhancement factors which is defined as a ratio of the heat transfer coefficient for micro-finned tube to that for smooth tube, varied from 1.3 to 1.6(mass flux:110~190kg/m$^{2}$s) for condensation and 1.2 to 1.5 (mass flux:70~160kg/m$^{2}$s) for evaporation. The experimental data of condensation and evaporation heat transfer coefficients were compared to several empirical correlations. Based on these comparisons, modified correlations of the condensation and evaporation heat transfer coefficient for both smooth and micro-finned tubes were proposed.

평활관 및 미세휜관 내에서의 물을 이용한 열전달 및 압력강하 특성에 관한 실험 (Experimental study of heat transfer and pressure drop characteristics for flow of water inside circular smooth and micro-fin tubes)

  • 박혁범;유승문;윤백;유국철
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.454-461
    • /
    • 1997
  • Heat transfer and pressure drop for single phase flow of water in circular smooth and micro-fin tubes are measured. Copper tubes of 9.52 and 7mm outer diameter were used. The internal roughness in micro-fin tubes was formed by spiral grooves having $25^{\circ}$ helx angle, 0. 12mm fin height and 0.454mm pitch in 9.52mm tubes; $18^{\circ}$ helix angle, 0.15mm fin height and 0.322mm pitch in 7mm tubes. The measured friction factor and heat transfer coefficient are compared with relevant previous works, and the correlations for micro-fin tube are developed.

  • PDF

충격관을 이용한 $C_2H_2$의 폭굉특성연구 (A Study on the Detonation Characteristics of $C_2H_2$in Shock Tube)

  • 오규형
    • 한국안전학회지
    • /
    • 제11권4호
    • /
    • pp.64-71
    • /
    • 1996
  • Detonation phenomena of $C_2H_2$were invesgated using the various shock tube. To study the detonation characteristics according to the composition of $C_2H_2-0_2$$_2$ and $C_2H_2$-air mixtures, the composition were varied from 5 to 90% and 5 to 50% of acetylene each other. A spiral ring was installed in the shock tube to study the effect of obstacles in DDT phenomena. Detonation velocities were measured using the photodiode, and the DDT phenomena was visualized using the high speed schlieren photograph. From the experimental result, it was found that the detonation velocity was most high near the 1. 8times the stoichiometric ratio of acetylene. And from the visualization of DDT phenomena, it was found that the detonation wave was strengthened throuth the pile up of small compression wave of burned gas. And the obstacles in shock tube accelerate the detonation reaction by turblent effect of flammable gas mixture.

  • PDF

터보 냉동기용 핀 튜브에 관한 연구(II) - 비등 열전달에 관하여 - (A Study on Finned Tube Used in Turbo Refrigerator(II) - on boiling heat transfer -)

  • 한규일;김시영;조동현
    • 수산해양교육연구
    • /
    • 제5권2호
    • /
    • pp.119-127
    • /
    • 1993
  • This work studies for heat transfer and pressure drop performance of integral inner and outer fin tubes, designed to enhance the heat transfer performance of smooth tubes for in recipro and turbo refrigerator or high performance compact heat exchangers. Eight different inner spiral fin copper tubes with integral fin at outside surfaces were employed to improve boiling heat transfer coeffcient. For comparison, tests were made using a plain tube having the inside diameter and an outside diameter equal to that at the root of the fins for the finned tubes. Pool boiling heat transfer is investigated experimentally and theoretically on single tube arrangement. The refrigerant evaporates at a saturation state of 1 bar on the outside tube surface heated by hot water. The refrigerant R11 ($CFCl_3$) was used at a pressure of $P_s=1bar$ as a convenient test fluid with a boiling temperature of $T_s=23.6^{\circ}C$. The observed heat transfer enhancement of boiling for finned tubes significantly exceeded that to be expected on grounds of increased area. The maximum Vapor - side enhancement(i.e., vapor - side heat transfer coefficient of finned tube/vapor - side coefficient for plain tube) was found to be around 4 at 1299fpm - 30grooves tube.

  • PDF