Three species of the genus Centropages(C. calaninus, C. orsinii, and C. sinensis) were newly collected from Korean waters. The Korean specimens were consistent with previous descriptions, but differ in the following characteristics: in C. orsinii male right antennule with spine on dorsoposterior surface of each segment XIII and XIV; distal end of segment XIX with humplike process on dorsal surface; in C. calaninus female long spinelike process on second exopodal segment of leg 5 of reaching 1/2 length of terminal spine on third exopodal segment; in male, first endopodal segment of leg 5 without inner seta; left second exopodal segment serrated on distal margin; and in C. sinensis male distal spine of left second exopodal segment of leg 5 not fused with segment. In this study, key characters for species identification also were provided.
Objective : Many biomechanical and clinical studies on adjacent segment degeneration (ASD) have addressed cranial segment. No study has been conducted on caudal segment degeneration after upper segment multiple lumbar fusions. This is a retrospective investigation of the L5-S1 segment after spinal fusion at and above L4-5, which was undertaken to analyze the rate of caudal ASD at L5-S1 after spinal fusion on and above L4-5 and to determine that factors that might have influenced it. Methods : The authors included 67 patients with L4-5, L3-5, or L2-5 posterior fusions. Among these patients, 28 underwent L4-5 fusion, 23 L3-5, and 16 L2-5 fusions. Pre- and postoperative radiographs were analyzed to assess degenerative changes at L5-S1. Also, clinical results after fusion surgery were analyzed. Results : Among the 67 patients, 3 had pseudoarthrosis, and 35 had no evidence of ASD, cranially and caudally. Thirteen patients (19.4%) showed caudal ASD, 23 (34.3%) cranial ASD, and 4 (6.0%) both cranial and caudal ASD. Correlation analysis for caudal ASD at L5-S1 showed that pre-existing L5-S1 degeneration was most strongly correlated. In addition, numbers of fusion segments and age were also found to be correlated. Clinical outcome was not correlated with caudal ASD at L5-S1. Conclusion : If caudal and cranial ASD are considered, the overall occurrence rate of ASD increases to 50%. The incidence rate of caudal ASD at L5-S1 was significantly lower than that of cranial ASD. Furthermore, the occurrence of caudal ASD was found to be significantly correlated with pre-existing disc degeneration.
The Journal of Korean Academy of Orthopedic Manual Physical Therapy
/
v.13
no.2
/
pp.12-20
/
2007
The purpose of this study was designed to find out the effectiveness of vertebral segment instability, muscle fatigue response on lumbar spine after apply lumbosacral stabilization exercise program to 4 patients with chronic low back pain and for 12 weeks. In this study, the lumbar spine motion with blind by MedX test machine and the difference of instability to lumbar vertebra segments in flexion, extension test of standing position and spinal load test(Matthiass Test) by Spinal Mouse. The stabilization exercise program was applied 2 times a week for 12 weeks in hospital and 2 times a day for 20 minutes at home. The results of the present study were as follows: 1. Instability test of lumbar vertebra segment is 2 type differential angle test between vertebrae segment and loading test of spine(matthiass) by Spinal Mouse. It appeared to improve stability of segments in sagittal plane after applying program. So lumbar spine curve increased lordosis toward anterior and was improved of the lumbar spine flexibility in flexion and extension. Specially, in matthiass test, (-) value was increased between lumbar vertebra segment when was the load on spine. And so applying stability improved after program. 2. Fatigue response test(FRT) results, in male, was raised muscle fatigue rate during increase weight, on the other hand female appeared lower than male. As a results, lumbosacral stabilization exercise was aided to improvement of lumbar spine vertebra segments stabilization. Spine instability patients will have a risk when in lifting a load or working with slight flexion posture during the daily of living life and it is probably to increase recurrence rate. Thus, not only lumbar extension muscle strength but also stability of vertebra segments in lumbar spine may be very important.
The purpose of this study was designed to find out the effectiveness of vertebral segment instability, muscle fatigue response on lumbar spine after apply lumbosacral stabilization exercise program to 4 patients with chronic low back pain and for 12 weeks. In this study, the lumbar spine motion with blind by MedX test machine and the difference of instability to lumbar vertebra segments in flexion, extension test of standing position and spinal load test(Matthiass Test) by Spinal Mouse. The stabilization exercise program was applied 2 times a week for 12 weeks in hospital and 2 times a day for 20 minutes at home. The results of the present study were as follows: 1. Instability test of lumbar vertebra segment is 2 type differential angle test between vertebrae segment and loading test of spine(matthiass) by Spinal Mouse. It appeared to improve stability of segments in sagittal plane after program. So lumbar spine curve increased lordosis toward anterior and was improved of the lumbar spine flexibility in flexion and extension. Specially, in matthiass test, ( - ) value was increased between lumbar vertebra segment when was the load on spine. And so stability improved after program. 2. Fatigue response test(FRT) results, in male, was raised muscle fatigue rate during increase weight, on the other hand female appeared lower than male. As a results, lumbosacral stabilization exercise was aided to improvement of lumbar spine vertebra segments stabilization. Spine instability patients will have a risk when in lifting a load or working with slight flexion posture during the daily of living life and it is probably to increase recurrence rate. Thus, not only lumbar extension muscle strength but also stability of vertebra segments in lumbar spine may be very important.
Cho, Pyung Goo;Ji, Gyu Yeul;Park, Sang Hyuk;Shin, Dong Ah
Asian Spine Journal
/
v.12
no.6
/
pp.1092-1099
/
2018
Study Design: In-vitro biomechanical investigation. Purpose: To evaluate the biomechanical effects of the degeneration of the biodegradable cervical plates developed for anterior cervical discectomy and fusion (ACDF) on fusion and adjacent levels. Overview of Literature: Biodegradable implants have been recently introduced for cervical spine surgery. However, their effectiveness and safety remains unclear. Methods: A linear three-dimensional finite element (FE) model of the lower cervical spine, comprising the C4-C6 vertebrae was developed using computed tomography images of a 46-year-old woman. The model was validated by comparison with previous reports. Four models of ACDF were analyzed and compared: (1) a titanium plate and bone block (Tita), (2) strong biodegradable plate and bone block (PLA-4G) that represents the early state of the biodegradable plate with full strength, (3) weak biodegradable plate and bone block (PLA-1G) that represents the late state of the biodegradable plate with decreased strength, and (4) stand-alone bone block (Bloc). FE analysis was performed to investigate the relative motion and intervertebral disc stress at the surgical (C5-C6 segment) and adjacent (C4-C5 segment) levels. Results: The Tita and PLA-4G models were superior to the other models in terms of higher segment stiffness, smaller relative motion, and lower bone stress at the surgical level. However, the maximal von Mises stress at the intervertebral disc at the adjacent level was significantly higher in the Tita and PLA-4G models than in the other models. The relative motion at the adjacent level was significantly lower in the PLA-1G and Bloc models than in the other models. Conclusions: The use of biodegradable plates will enhance spinal fusion in the initial stronger period and prevent adjacent segment degeneration in the later, weaker period.
Kim, Kang-San;Hwang, Hyung-Sik;Jeong, Je-Hoon;Moon, Seung-Myung;Choi, Sun-Kil;Kim, Sung-Min
Journal of Korean Neurosurgical Society
/
v.46
no.5
/
pp.437-442
/
2009
Objective : To characterize perioperative biomechanical changes after thoracic spine surgery. Methods : Fifty-eight patients underwent spinal instrumented fusions and simple laminectomies on the thoracolumbar spine from April 2003 to October 2008. Patients were allocated to three groups; namely, the laminectomy without fusion group (group I, n = 17), the thoracolumbar fusion group (group II, n = 27), and the thoracic spine fusion group (group III, n = 14). Sagittal (ADS) and coronal (ADC) angles for adjacent segments were measured from two disc spaces above lesions at the upper margins, to two disc spaces below lesions at the lower margins. Sagittal (TLS) and coronal (TLC) angles of the thoracolumbar junction were measured from the lower margin of the 11th thoracic vertebra body to the upper margin of the 2nd lumbar vertebra body on plane radiographs. Adjacent segment disc heights and disc signal changes were determined using simple spinal examinations and by magnetic resonance imaging. Clinical outcome indices were determined using a visual analog scale. Results : The three groups demonstrated statistically significant differences in terms of angle changes by ANOVA (p<0.05). All angles in group I showed significantly smaller angles changes than in groups II and III by Turkey's multiple comparison analysis. Coronal Cobb's angles of the thoracolumbar spine (TLC) were not significantly different in the three groups. Conclusion : Postoperative sagittal balance is expected to change in the adjacent and thoracolumbar areas after thoracic spine fusion. However, its prevalence seems to be higher when the thoracolumbar spine is included in instrumented fusion.
Park, Won-Man;Kim, Ki-Tack;Hong, Gyu-Pyo;Kim, Yoon-Hyuk;Oh, Taek-Yul
Korean Journal of Computational Design and Engineering
/
v.13
no.1
/
pp.58-66
/
2008
The artificial discs have recently used to preserve the motion of the treated segment in lumbar spine surgery. However, there have been lack of biomechanical information of the artificial discs to explain current clinical controversies such as long-term results of implant wear and excessive facet contact forces. In this study, we investigated the biomechanical effects of three artificial implants on the lumbar spinal segments by finite element analysis. The finite element model of intact lumbar spine(L1-S) was developed and the three implants were inserted in L4-L5 segment of the spine model. 5 Nm of flexion and extension moments were applied on the superior plate of L1 with 400 N of compressive load. Excessive motions and high facet contact forces at the surgical level were generated in the all three implanted models. In the flexion, the peak von-Mises stresses in the semi-constrained type implant was higher than those in the un-constrained type implant which would cause wear on the polyethylene core. The results of the study would provide a biomechanical guideline for selecting optimal surgical approach or evaluating the current design of the implants, or developing a new implant.
Journal of the Korean Society for Precision Engineering
/
v.20
no.10
/
pp.226-232
/
2003
Difficulties in the finite element modeling of human spine are evaded by using a stiffness matrix element whose properties can be characterized from experimentally measured stiffness of functional spinal units. Relative easiness is in that inter-vertebral discs, ligaments, and soft tissues connecting vertebrae do not need to be modeled as they are. The remarkable coupling effect between distinct degrees of freedom induced by the geometric complexity can be accommodated without much effort. An idealized block model with simple geometry for vertebra is employed to assess the feasibility of this method. Analyses are performed in both levels of motion segment and spinal column, and the result is compared with that from detail model. As far as the global behavior of spine is concerned, the simplification is found not to aggravate inaccuracy only if sufficient experimental data is provided and interpreted properly.
A new cyclopoid species belonging to the genus Acanthocyclops is described from several mountain springs in South Korea. This species is allied to A. kieferi species group in sharing 11-segmented antennules, but is, clearly distinguished from them by its single apical spine on the third endopodal segment of leg 4 and an extra spine on the distal segment of leg 5 in both sexes.
Study Design: This retrospective study was conducted including 18 patients who underwent posterior-only stabilization and fusion procedure for pseudoarthrosis in the ankylosed spine from October 2007 to May 2015. Purpose: This study aimed to describe the treatment outcomes in 18 patients with Andersson lesion (AL) who were managed using the posterior-only approach. Literature Review: AL is an unstable, localized, vertebral, or discovertebral lesion of the spine. It is observed in patients with ankylosing spondylitis. The exact etiology of this disorder remains unclear, and the treatment guidelines are not clearly described. Methods: We analyzed 18 patients with AL who were treated with posterior long segment spinal fusion without any anterior interbody grafting or posterior osteotomy. Pre- and postoperative radiography, computed tomography, and recent follow-up images were examined. The pre- and postoperative Visual Analog Scale score and the Oswestry Disability Index score were evaluated for all patients. Whiteclouds' outcome analysis criteria were applied at the follow-up. Moreover, at study completion, patient feedback was collected; all the patients were asked to provide their opinion regarding the surgery and were asked whether they would recommend this procedure to other patients and them self undergo the same procedure again if required. Results: The most common site was the thoracolumbar junction. The symptom duration ranged from 1 month to 10 years preoperatively. Most patients experienced fusion by the end of 1 year, and the fusion mass could be observed as early as 4 months. Pseudoarthrosis void of up to 2.5 cm was noted to be healed in subsequent imaging. In addition, clinically, the patients reported good symptomatic relief. No patient required revision surgery. Whiteclouds' outcome analysis score at the latest follow-up revealed goodto-excellent outcomes in all patients. Conclusions: ALs can be treated using the posterior-only approach with long segment fixation and posterior spinal fusion. This is a safe, simple, and quick procedure that prevents the morbidity of anterior surgery.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.