• 제목/요약/키워드: Spin test

검색결과 158건 처리시간 0.027초

S, J, K 주파수영역에서 $MgFe_2O_4$ 단결정의 강자성공명 연구 (FMR Study of $MgFe_2O_4$ Single Crystal in S, J, K-band)

  • 박만장;김기현;이혜정;김영호
    • 한국자기학회지
    • /
    • 제6권5호
    • /
    • pp.298-304
    • /
    • 1996
  • 2~35 GHz(S, G, J, X, K, Q-영역) FMR(ferromagnetic resonance) 장치를 제작하였다. 제작된 FMR장치로 ESR(electron spin resonance) 표준시료 DPPH에 대한 공명흡수선을 관측한 결과 Q값이 189~1096으로 장치가 잘 제작 되었음을 알 수 있었다. 한편 자성반도체 $MgFe_2O_4$ 단결정을 S, J, K-영역에서 강자성 공명실험을 한 결과 g값이 S, J, K-영역에서 각각 2.02, 1.89, 2.01, 이방성상수 $K_{1}$이 각각 $-2.9{\times}10^{4}erg/cm^{3}$, $-2.2{\times}10^{4}erg/cm^{3}$, $-2.8{\times}10^{4}erg/cm^{3}$이었다. 이들 값은 X-영역에서 보고된 값들과 잘 일치하였다.

  • PDF

간 전이환자에서 최적의 펄스시퀀스에 따른 SPIO 특이성 조영제의 국소병변검출: Case review (Focal Lesion Detection of SPIO-specific agent Compared with Optimized Pulse Sequences in the Hepatic Metastases: Case Review)

  • 구은회
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.57-61
    • /
    • 2012
  • To compare the accuracy of breath-hold magnetic resonance imaging sequences to establish the most effective superparamagnetic iron oxide-enhanced sequence for detection of hepatic metastases. A total of 100 patients(50men and 50women, mean age: 60years) with liver disease(including malignant and benign liver lesions) were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) with 8Ch body coil. Pulse sequence for MR imaging decided to the FS-T2-FSE-RT(TR/TE/Thick./Freq./Phase=12857ms/100ms/7mm/512/384), MGRE(TR/TE/Thick./Freq./Phase=100ms/9.7ms/7mm/384/288), in-out of phase echo(TR/$TE_1$, $TE_2$/Thick./Freq./Phase=140ms/2.4, 5.8ms/7mm/352/300), Images obtained before the injection of SPIO. Six sequences were optimized for lesion detection: FS-T2-FSE-RT, multigradient recalled echo data image(MGRE), T2-weighted MGRE with an 9.7msec echo time. Images were reviewed independently by five blinded observers. The accuracy of each sequence was measured by using picture archiving communication system analysis. All results were correlated with findings at multidectator computed tomography examination. Differences between the mean results of the six observers were measured by using paired student t-test analysis. Postcontrast T2-weighted MGRE sequences were the most accurate and were significantly superior to postcontrast FS-T2-FSE-RT, T2-weighted MGRE, in-out of phase MR sequences(p < .05). For all lesions that were malignant or smaller than 1 cm, respectively, contrast to noise ratio of pre and postcontrast sequences were -1and -0.3 for T2-weighted FSE, 0.53 and 4.5 in-out of phase, 7, 7.08, 5.08, 3.32, 1.7, 1.16, 0.79, 0.68 for GRE with 2.9, 7.5, 12.1, 16.6, 21.2, 25.8, 30.4, 35.0 TE values. Breath-hold various TE precontrast sequences offer improvement in sensitivity compared with fixed multigradient recalled echo sequences alone.

  • PDF

Rotational Properties of the Maria Asteroid Family

  • Kim, Myung-Jin;Choi, Young-Jun;Moon, Hong-Kyu;Byun, Yong-Ik;Brosch, Noah;Kaplan, Murat;Kaynar, Suleyman;Uysal, Omer;Guzel, Eda;Behrend, Raoul;Yoon, Joh-Na;Mottola, Stefano;Hellmich, Stephan;Hinse, Tobias C.;Eker, Zeki;Park, Jang-Hyun
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.66.2-66.2
    • /
    • 2014
  • We carried out photometric observations of Maria family asteroids during 134 nights spanning from July 2008 to May 2013, and derived synodic rotational periods for 51 objects including obtained periods of 34 asteroids for the first time. In this study, we found that there is a significant excess of fast and slow rotators. The one-sample Kolmogorov-Smirnov test confirms that the spin rate distribution is not consistent with the Maxwellian at a 92% confidence level. From the correlations between rotational period, amplitude of lightcurve, and size, we conclude that rotational properties of Maria family have been changed considerably by the non-gravitational force such as the Yarkovsky and the YORP effect. Using the lightcurve inversion method, we successfully determined the pole orientation for the 13 Maria members, and found the excess of prograde objects versus retrograde with a ratio ($N_p/N_r$) of 3. This implies that retrograde rotators could have been ejected by the 3:1 resonance to the inner Solar System since the generation of Maria family. We estimate that approximately 37 - 75 kilometer-sized Maria asteroids have entered to near-Earth space every 100 Myr.

  • PDF

The Influence of Hydrotalcite Intercalated with Benzoate on UV Stability of Acrylic Coating

  • Nguyen, Thuy Duong;Nguyen, Anh Son;Thai, Thu Thuy;Pham, Gia Vu;To, Thi Xuan Hang;Olivier, Marie-Georges
    • Corrosion Science and Technology
    • /
    • 제19권1호
    • /
    • pp.16-22
    • /
    • 2020
  • It is important to realize that benzoate was intercalated into hydrotalcite (HTC-Bz) by the co-precipitation method. In this case, acrylic coating with 0.5 wt% HTC-Bz was deposited on carbon steel using the spin coating method. Next, the HTC-Bz structure was characterized by Field emission scanning electron microscopy (FESEM), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FT-IR). In fact, an ultraviolet vision spectroscopy (UV-Vis) was used to determine the benzoate content in HTC-Bz, and the UV absorption ability of HTC-Bz. Using electrochemical techniques, water contact angle measurement, and thermal-gravimetric analysis, we compared the protective properties before and after QUV test, hydrophobicity and the thermal stability of acrylic coating containing HTC-Bz. The obtained results showed that HTC-Bz with a plate-like structure was successfully synthesized; benzoate was intercalated into the interlayer of hydrotalcite with a concentration of 28 wt%. Additionally, it was noted that HTC-Bz has an UV absorption peak at 225 nm. In conclusion, the addition of HTC-Bz enhanced the UV stability, hydrophobicity and the thermal stability of acrylic coating.

SoP-L 기술 기반의 반도체 기판 함몰 공정에 관한 연구 (Study on the Buried Semiconductor in Organic Substrate)

  • 이광훈;육종관;박세훈;유찬세;이우성;김준철;강남기;박종철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.33-33
    • /
    • 2007
  • SoP-L 공정은 유전율이 상이한 재료를 이용하여 PCB 공정이 가능하고 다른 packaging 방법에 비해 공정 시간과 비용이 절약되는 잠정이 있다. 본 연구에서는 SoP-L 기술을 이용하여 Si 기판의 함몰에 판한 공정의 안정도와 함몰 시 제작된 때턴의 특성의 변화에 대해 관찰 하였다. Si 기판의 함몰에 Active device를 이용하여 특성의 변화를 살펴보고 공정의 안정도를 확립하려 했지만 Active device는 측정 시 bias의 확보와 특성의 민감한 변화로 인해 비교적 측정이 용이하고 공정의 test 지표를 삼기 위해 passive device 를 구현하여 함몰해 보았다. Passive device 의 제작 과정은 Si 기판 위에 spin coating을 통해 PI(Poly Imide)를 10um로 적층한 후에 Cr과 Au를 seed layer로 증착을 하였다. 그리고 photo lithography 공정을 통하여 photo resister patterning 후에 전해 Cu 도금을 거쳐 CPW 구조로 $50{\Omega}$ line 과 inductor를 형성하였다. 제작 된 passive device의 함몰 전 특성 추출 data와 SoP-L공정을 통한 함몰 후 추출 data 비교를 통해 특성의 변화와 공정의 안정도를 확립하였다. 차후 안정된 SoP-L 공정을 이용하여 Active device를 함몰 한다면 특성의 변화 없이 size 룰 줄이는 효과와 외부 자극에 신뢰도가 강한 기판이 제작 될 것으로 예상된다.

  • PDF

Spray coating of electrochemically exfoliated graphene/conducting polymer hybrid electrode for organic field effect transistor

  • Kim, Youn;Kwon, Yeon Ju;Hong, Jin-Yong;Park, Minwoo;Lee, Cheol Jin;Lee, Jea Uk
    • Journal of Industrial and Engineering Chemistry
    • /
    • 제68권
    • /
    • pp.399-405
    • /
    • 2018
  • We report the fabrication of organic field-effect transistors (OFETs) via spray coating of electrochemically exfoliated graphene (EEG) and conducting polymer hybrid as electrodes. To reduce the roughness and sheet resistance of the EEG electrodes, subsequent coating of conducting polymer (poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS)) and acid treatment was performed. After that, active channel layer was developed by spin coating of semiconducting poly(3-hexylthiophene) on the hybrid electrodes to define the bottom gate bottom contact configuration. The OFET devices with the EEG/PEDOT:PSS hybrid electrodes showed a reasonable electrical performances (field effect mobility = $0.15cm^2V^{-1}\;s^{-1}$, on/off current ratio = $10^2$, and threshold voltage = -1.57V). Furthermore, the flexible OFET devices based on the Polydimethlsiloxane (PDMS) substrate and ion gel dielectric layer exhibited higher electrical performances (field effect mobility = $6.32cm^2V^{-1}\;s^{-1}$, on/off current ratio = $10^3$, and threshold voltage = -1.06V) and excellent electrical stability until 1000 cycles of bending test, which means that the hybrid electrode is applicable to various organic electronic devices, such as flexible OFETs, supercapacitors, organic sensors, and actuators.

진공 척을 이용한 마이크로 LED 대량 전사 공정 개발 (Micro-LED Mass Transfer using a Vacuum Chuck)

  • 김인주;김용화;조영학;김성동
    • 마이크로전자및패키징학회지
    • /
    • 제29권2호
    • /
    • pp.121-127
    • /
    • 2022
  • 마이크로 LED는 크기가 100 ㎛ 이하인 LED 소자로 기존 LED에 비해 해상도, 밝기 등 여러 면에서 우수한 성능을 보일 뿐 아니라 유연 디스플레이, VR/AR 등 다양한 분야에 적용이 가능하다. 마이크로 LED 디스플레이를 제작하기 위해선 LED 웨이퍼로부터 최종기판으로 마이크로 LED를 옮기는 전사 공정이 필수적이며, 본 연구에서는 진공 척을 이용하여 마이크로 LED를 고속 대량 전사하는 방식을 제안하고 이를 검증하였다. MEMS 기술을 이용한 PDMS 마이크로 몰딩 공정을 통해 진공 척을 제작하였으며, PDMS 몰딩 공정을 제어하기 위해 댐 구조를 이용한 스핀 코팅 공정을 성공적으로 적용하였다. 솔더볼을 이용한 진공 척 구동 실험을 통해 진공 척을 이용한 마이크로 LED의 대량 전사 가능성을 확인하였다.

Polarity affects the antioxidant and antimicrobial activities of jellyfish (Acromitus hardenbergi) extracts

  • Khong, Nicholas M.H.;Foo, Su Chern;Yau, Sook Kun;Chan, Kim Wei;Yusoff, Fatimah Md.
    • Fisheries and Aquatic Sciences
    • /
    • 제25권4호
    • /
    • pp.189-201
    • /
    • 2022
  • Jellyfish is an emerging aquaculture species, farmed for Oriental cuisines and nutraceutical ingredients. This study aimed to examine antioxidative and antimicrobial potentials of various fractions of the jellyfish, Acromitus hardenbergi. The bell and oral arms of the jellyfish were sequentially extracted with petroleum ether (PE), dichloromethane (DCM), chloroform (CHCl3), methanol (MeOH), and water (H2O) to extract its bioactive in an increasing polarity gradient. Test fractions were assayed for antiradical activities using electron spin resonance spectrometry, β-carotene-linoleate model and Folin-Ciocalteu assay; and antimicrobial activity against 2 Gram-negative bacteria, 4 Gram-positive bacteria and 2 fungal species using the disc diffusion assay. All fractions were also subjected to Fourier Transform Infrared (FTIR) analysis to identify types of functional groups present. It was found that the hydrophilic extracts (H2O fractions) possessed the most effective radical scavenging activity (p < 0.05) while the lipophilic extracts (PE fractions) the most active antimicrobial activity, especially against Gram-positive bacteria (p < 0.05). Total oxidation substrates content was found to be highest in the PE fractions of jellyfish bell and oral arms (p < 0.05). FTIR data showed that the H2O and MeOH fractions contains similar functional groups including -OH, -C=O, -N-H and -S=O groups, while the PE, DCM, and CHCl3 fractions, the -CH3, -COOH groups. This study showed that A. hardenbergi contains antioxidants and antimicrobials, thereby supporting the traditional claim of the jellyfish as an anti-aging and health-promoting functional food. Bioassay-guided fractionation approach serves as a critical milestone for the strategic screening, purification, and elucidation of therapeutically significant actives from jellyfish.

응력에 의한 밀도증가의 영향과 액상화 원심모형실험을 위한 모형지반성형법 (The Influence of Stress-induced Densification and Centrifuge Model Preparation Method for Soil Liquefaction)

  • 박성식
    • 한국지반공학회논문집
    • /
    • 제22권11호
    • /
    • pp.151-158
    • /
    • 2006
  • 균일한 모래지반을 이용한 원심모형실험에서는 지표면근처에서 액상화가 발생한 후에 점차적으로 깊은 곳으로 전파되는 경향을 보였다. 이와 같은 현상은 실내실험에서 상재하중효과를 고려했을 때 관찰되는 액상화현상과 상반되는 것처럼 보인다. 그러나, 응력증가에 따른 모형지반의 상대밀도증가가 구속압증가에 따른 액상화저항감소를 상쇄시킨다. 이와 같은 응력증가에 따른 상대밀도증가는 실제 원심모형실험에서 발생하고 있으나, 모형지반성형법에서는 고려되고 있지 않다. 따라서, 본 논문에서는 원심모형실험에서 발생할 수 있는 상대밀도증가를 고려한 새로운 원심모형지반성형법을 제안하였다. 새로운 모형지반성형법은 액상화에 관한 $K_0$ 효과를 연구하는데 사용될 수 있으며, 본 연구에서는 수치해석방법을 이용하여 그 실용성을 증명하였다.

Benefit of Using Early Contrast-Enhanced 2D T2-Weighted Fluid-Attenuated Inversion Recovery Image to Detect Leptomeningeal Metastasis in Lung-Cancer Staging

  • Kim, Han Joon;Lee, Jungbin;Lee, A Leum;Lee, Jae-Wook;Kim, Chan-Kyu;Kim, Jung Youn;Park, Sung-Tae;Chang, Kee-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제26권1호
    • /
    • pp.32-42
    • /
    • 2022
  • Purpose: To evaluate the clinical benefit of 2D contrast-enhanced T2 fluid-attenuated inversion recovery (CE-T2 FLAIR) image for detecting leptomeningeal metastasis (LM) in the brain metastasis work-up for lung cancer. Materials and Methods: From June 2017 to July 2019, we collected all consecutive patients with lung cancer who underwent brain magnetic resonance image (MRI), including contrast-enhanced 3D fast spin echo T1 black-blood image (CE-T1WI) and CE-T2 FLAIR; we recruited clinico-radiologically suspected LM cases. Two independent readers analyzed the images for LM in three sessions: CE-T1WI, CE-T2 FLAIR, and their combination. Results: We recruited 526 patients with suspected lung cancer who underwent brain MRI; of these, we excluded 77 (insufficient image protocol, unclear pathology, different contrast media, poor image quality). Of the 449 patients, 34 were clinico-radiologically suspected to have LM; among them, 23 were diagnosed with true LM. The calculated detection performance of CE-T1WI, CE-T2 FLAIR, and combined analysis obtained from the 34 suspected LM were highest in the combined analysis (AUC: 0.80, 0.82, and 0.89, respectively). The inter-observer agreement was also the highest in the combined analysis (0.68, 0.72, and 0.86, respectively). In quantitative analyses, CNR of CE-T2 FLAIR was significantly higher than that of CE-T1WI (Wilcoxon signed rank test, P < 0.05). Conclusion: Adding CE-T2 FLAIR might provide better detection for LM in the brain-metastasis screening for lung cancer.