• Title/Summary/Keyword: Spillage

Search Result 85, Processing Time 0.034 seconds

Dosimetric Evaluation of Low-Dose Spillage Volumes for Head and Neck Cancer Using Intensity-Modulated Radiation Therapy and Volumetric Modulated Arc Therapy Treatment Techniques

  • Kumar, Gourav;Bhushan, Manindra;Kumar, Lalit;Kishore, Vimal;Raman, Kothanda;Kumar, Pawan;Barik, Soumitra;Purohit, Sandeep
    • Progress in Medical Physics
    • /
    • v.32 no.3
    • /
    • pp.70-81
    • /
    • 2021
  • Purpose: This study was designed to investigate the dosimetric difference between intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) in head and neck cancer (HNC). The study primarily focuses on low-dose spillage evaluation between these two techniques. Methods: This retrospective study involved 45 patients with HNC. The treatment plans were generated using the IMRT and VMAT techniques for all patients. Dosimetric comparisons were performed in terms of target coverage, organ-at-risk (OAR) sparing, and various parameters, including conformity index, uniformity index, homogeneity index, conformation number, low-dose volumes, and normal tissue integral dose (NTID). Results: No significant (P>0.05) difference in planning target volume coverage (D95%) was observed between IMRT and VMAT plans for supraglottic larynx, hard palate, and tongue cancers. A decrease in dose volumes ranging from 1 Gy to 30 Gy was observed for VMAT plans compared with those for IMRT plans, except for V1Gy and V30Gy for supraglottic larynx cancer and V1Gy for tongue cancer. Moreover, decreases (P<0.05) in NTID were observed for VMAT plans compared with that for IMRT plans in supraglottic larynx (4.50%), hard palate (12.80%), and tongue (7.76%) cancers. In contrast, a slight increase in monitor units for VMAT compared with those for IMRT in supraglottic larynx (0.46%), hard palate (2.54%), and tongue (7.56%) cancers. Conclusions: For advanced-stage HNC, both IMRT and VMAT offer satisfactory clinical plans. VMAT offers a conformal and homogeneous dose distribution with comparable OAR sparing and higher dose falloff outside the target volume than IMRT, which provides an edge to reduce the risk of secondary malignancies for HNC over IMRT.

A Study on the Japanese Maritime Oil Spillage Management System and Activities (일본의 해양유탁 방제체제와 방제활동에 관한 연구)

  • Choi, Young-Ho
    • Journal of Navigation and Port Research
    • /
    • v.26 no.4
    • /
    • pp.407-417
    • /
    • 2002
  • Japanese oil companies have begun to set up a mutual support system to prepare for any large scale oil spillages due to the huge increase in size of tankers since 1973. In 1990, the Petroleum Association of Japan established the Oil Spill Response Department and has been conducting researches on management of oil spill combatting materials and the effective prevention of maritime oil disasters. Japan Coast Guard, in accordance with the regulations of the OPRC in 1995, formulated the national contingency plan and built a mutual-contact network among the related government institutions. Its Guard & Rescue Department. Disaster Prevention Section has been working for the maintenance of oil spill combatting materials and coordinating related work with private organizations. The Japanese government has been strengthening the maritime oil spillage management system since the Nakhodka wreck incident in 1997.

Assessment of the Naktong River Pollution after Phenol Spillage from the Kumi Industrial Estates II, Korea (페놀오염사건 이후의 낙동강수 오염평가)

  • Kim, Doo-Hie;Jang, Bong-Ki;Hong, Sung-Chul;Moon, Hyo-Jung;Lee, Duck-Hee;Oh, Hae-Ju
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.2 s.42
    • /
    • pp.268-281
    • /
    • 1993
  • The aquatic quality of the Naktong river after two or three months in June, 1991 with phenol spillage from a electrical factory in Kumi was investigated. The samples were collected at six sites of the Naktong river basin and Kachang and Kongsan lakes. Phenol was not detected from all water samples. Turbidity was very much increased to the down stream in the Naktong river. The BOD and COD values exceeded the 2nd grade(3mg/l) of the Korean standard quality of Environmenal Water Act at the all sampling sites of the Naktong river. Especially, the value of COD at Kaejin (12.5mg/l) was poorly classified as to the 5th grade of water class for the environmental quality standards. Organophosphorous pesticides such as parathion, malathion, fenitrothion and diazinon were investigated but not detected. Diazinon was only detected at the Ilsan bridge(1.42ppb), Okkye stream(6.95ppb), Waekwan bridge(0.32ppb), Gangjung reservior(0.13ppb), Kaejin (0.05ppb). Of the carbamates such as carbanyl, isoprocarb and cabofuran, the carbofuran was detected all sites except tap water, and Kachang and Kongsan lakes. The content of heavy metals such as Cd, Pb, Zn, Fe, Mn, Hg were not exceeding for drinking water standards at the all sampling region, but only mecury was detected from Okkye stream(0.018ppb) and Kaejin (0.09ppb). In the regions of Kachang and Kongsan lakes, the content of heavy meatals were lower than that of reservior of Naktong river.

  • PDF

Effect of Biomass Co-firing Ratio on Operating Factors of Pulverizer in 500 MW Coal-fired Power Plant (500 MW 석탄화력 발전소에서 바이오매스 혼소율이 미분기 운전인자에 미치는 영향)

  • Geum, Jun Ho;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.18 no.3
    • /
    • pp.28-40
    • /
    • 2022
  • As the proportion of renewable energy generation is expected to increase, public power generation businesses need to actively consider implementing the expansion of biomass mixing, In this study, the biomass co-firing rate is being changed from 0wt.% to 5.0wt.% at 500MW coal-fired power plant, measuring the major operation characteristics of the pulverizer. First, the composition analysis and grinding characteristics of lignocelluosic biomass were examined, and the effect of volume increase on dirrerential bowl pressure difference, motor current, coal spillage, outlet temperature, and internal fire count was analyzed. As the co-firing rate increased, it was confirmed that the difference in the differential bowl pressure, motor current, and coal spillage treated increased, and the outlet temperature was minimal. The number of internal fires is difficult to find a clear correlation, but it has been confirmed that it is highly likely to occur in combination with other driving factors.

  • PDF

Functioning Parathyroid Carcinoma - A Case Report - (기능성 부갑상선암)

  • Lim Dae-Jin;Choi Jin-Sub;Han Jee-Young;Lim Seung-Kil;Park Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.9 no.1
    • /
    • pp.56-62
    • /
    • 1993
  • The parathyroid carcinoma is a rare cause of primary hyperparathyroidism. There was approximately 170 reports in the would literature. and only two documented cases in Korean literature. It is still difficult to distinguish. histologically, benign from malignant parathyroid tumors. However, if diagnotic criteria are that strict, it can be suscessfully cured by initial operation. The initial operation should be an en bloc resection of the tumor, avoiding rupture of the tumor capsule and spillage of tumor cells. This report details the management of a 51 year old female with functioning parathyroid carcinoma who underwent an en bloc resection of the tumor at the time of initial operation.

  • PDF

Posterior Thoracotomy under the Prone Position in Children - Report of 3 Cases - (소아에서 복와위하의 개흉술 3례 보고)

  • 김기봉
    • Journal of Chest Surgery
    • /
    • v.24 no.10
    • /
    • pp.1000-1004
    • /
    • 1991
  • Children`s small airway precludes the use of standard methods of bronchial separation. So, we performed the posterior thoracotomy under the prone position in 3 cases to avoid endobronchial gravity spillage of secretion and infected debris from the diseased lung to the contralateral sound lung. The advantages of the posterior thoracotomy under the prone position was discussed. In two cases, empyema with total collapse of left lung and congenital cystic adenomatoid malformation [CCAM] of right lung, copious secretion was spilled through the endotracheal tube but could be removed successfully by the endotracheal suction. In the third case of bilateral peripleural abscess, bilateral posterior thoractomy was done without position change. All procedures were performed without any technical difficulty and complication.

  • PDF

Optimal Design of a Quick-Acting Hydraulic Fuse using Genetic Algorithm and Complex Method (유전자 알고리즘과 콤플렉스법에 의한 고성능 유압휴즈의 최적 설계)

  • Lee, S.R.
    • Journal of Drive and Control
    • /
    • v.11 no.4
    • /
    • pp.32-38
    • /
    • 2014
  • The hydraulic fuse, which responds to the suddenly increased flow on rupture of a line and shuts off the fluid flow, would prevent large spillage of liquid. The quick-acting hydraulic fuse, which is mainly composed of a poppet, a seat, and a spring, must be designed to minimize the leaked flow and to prevent high collision speed between the poppet and seat during fuse operation on a line rupture. The optimal design parameters of a quick-acting hydraulic fuse were searched using the genetic algorithm and the complex method that are kinds of constrained direct search methods. The dynamic behavior of a quick-acting hydraulic fuse was researched using computer simulations that applied the obtained optimal design parameters.

A case of Esophageal Cancer with Pneumopericardium (식도암에 동반된 심막기종)

  • Hwang, Jin-Su;Choi, Soo-Mi;Lee, Heung-Bum;Lee, Yong-Chul;Rhee, Yang-Keun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.6
    • /
    • pp.1305-1309
    • /
    • 1998
  • A diabetic 73-year-old man had admitted and examined gastrofiberoscopy due to dyspagia and weight loss of 6 kg during two months. He was confirmed diagnosis of esophageal squamous cell carcinoma. During the esophgography, we found the dye spillage into pericardia! space from the esophagus with air collection A following chest roentgenogram revealed a typical pneumopericardium with pericardial air filling. Although intensive care was done. he expired 4 days later. We report a case of typical pnemopericardium caused secondary to esophageal cancer.

  • PDF

Overview of Major Oil Spill at Sea and Details of Various Response Actions 2. Analysis of Marine Oil Pollution Incidents in Korea (대형 기름유출사고와 방제조치에 관한 연구 2. 국내 해양 기름오염사고 분석)

  • Kim, Kwang-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.5
    • /
    • pp.467-475
    • /
    • 2013
  • In order to seize quantitative materials as part of studies on measures for oil pollution prevention and control, the statistics of oil pollution incidents in Korean coastal waters for 10 years from 2003 to 2012 were analyzed with relation to the number of oil spills and the volume of oil spilt according to causes, sources and sea areas of spills. Total number and total volume of oil spills for 10 years were found to be 2,833 cases and 17,877 kL, respectively. 50.4 %(1,429 cases) of total number of oil spills were caused by negligence, although oil spillage due to negligence was 294 kL(1.7 %). While oil spillage caused by marine accidents was 17,400 kL(97.3 %), marine accidents accounted for 27.9 %(790 cases) of total number of oil spills. While negligence had a great influence on the number of oil spills, marine accidents had a huge impact on the amount of oil spilt. Fishing boats accounted for 42.7 %(1,210 cases) of the number of oil spills, and although oil tankers accounted for 9.2 %(261 cases) of the number of oil spills, oil spillage from oil tankers was 15,488kL(86.7 %). It means that oil tankers such as VLCC or ULCC may be the main sources of major oil spills and a few very large spills are responsible for a high percentage of the amount of oil spilt. While the number of oil spill incidents was closely related to the accidents of fishing boats, the volume of oil spilt was greatly affected by the major oil spill incidents of oil tankers such as M/T Hebei Spirit. The number and volume of oil spills were shown to be 1,613 cases(56.9 %) and 3,804 kL(21.3 %) in South Sea, 700 cases(24.7 %) and 13,501 kL(75.5 %) in West Sea, and 520 cases(18.2 %) and 572 kL(3.2 %) in East Sea of Korea, respectively. The highest number of oil spills was found in South Sea and the most volume of oil spilt was shown in West Sea of Korea for 10 years.

Studies on the Nutrition under Abnormal Environment(I) -Nutrition under Vibration- (이상환경하(異常環境下)의 영양문제(營養問題) 연구(硏究)(제1보) -진동하(振動下)의 영양문제(營養問題)-)

  • Yu, Jong-Yull
    • Journal of Nutrition and Health
    • /
    • v.4 no.4
    • /
    • pp.15-23
    • /
    • 1971
  • On the assumption that the supplementation of certain nutrients or foods to the rice diet (low protein, low fat, and low vitamins) may decrease, to some extent, the degree of suffering from abnormal environments, such as vibration, noises, gases, dusts, smog etc. a series of experiments were started. As the first report the nutrition under vibration was studied in this experiment. Sixty (60) young growing male rats weighing about 65 grams were used, grouping to five (5) groups, twelve (12) rats each group. They were fed on the following five (5) experimental diets: rice diet (basal diet), rice diet+casein, rice diet+vitamins, rice $diet+{\alpha}-tocopherol$, and rice diet+ginseng powder (see the tables 1 and 2) for the period of 14 weeks experiment. During the experiment period the half number of the rats of each group were exposed to the three (3) hours vibration every day. The protective effect of each diet against the vibration may be summarized as follows. 1. The growth of rice diet group was impaired significantly under vibration, However, those of other groups (protein-supplemented, vitamin-supplemented, ${\alpha}-tocopherol-supplemented$ and ginseng-supplemented groups) were impaired much less compared with rice diet group. 2. The feed efficiency of the rice diet group was decreased significantly under vibration. It is estimated that the biological availability of nutrients was impaired under this environment. On the other hand, the feed efficiencies of protein supplemented, of vitamin supplemented, and of ginseng supplemented groups were not decreased under vibration, statistically. 3. There is tendency that the food spillages of vibration groups are higher than those of non-vibration groups. Especially it seems true in the case of rice diet group. The food spillage may be, to some extent, related with mental nervousness of animals. From the point that the food spillage of ginseng supplemented group is significantly lower than those of other groups it is thought ginseng acts some good role in protecting nervous system from suffering from vibration. 4. In all groups except protein supplemented group, liver fat of vibration group tends to be higher than that of non-vibration group. 5. It shows that, in general, the serum alkaline phosphatase activity of the vibration group is significantly higher than that of the non-vibration group. It seems that there may be, to some extent, corelation between the amount of liver fat and serum alkaline phosphatase activity. 6. There is tendency that, in rice diet group, the organs of vibration group are smaller than those of non-vibration group, especially lung is so. It is thought that this may be due to the poor growth of whole body size in vibration group.

  • PDF