• Title/Summary/Keyword: Spherical equivalent

Search Result 140, Processing Time 0.033 seconds

Study on Evaluation of Refraction Measurement for Clinical Application (임상적 적용을 위한 굴절력 측정의 평가에 관한 연구)

  • Yoo, Jong-Sook;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.55-62
    • /
    • 2006
  • Clinical evaluation of the Closed-view autorefractor and Open-view autorefractor was performed to examine validity and repeatability compared with subjective refraction. Measurements of refractive error were performed on 126 eyes of 65 subjects (aged $26{\pm}7.5$ years) subjectively noncycloplegic. Intersession repeatability of the Closed-view and Open-view were also assessed on all 65 subjects together with Intersession repeatability on 7 to 14 days intervals. Spherical powers and spherical equivalent values of subjective refraction and autorefractions by Closed-view and Open-view were analyzed by paired T-test. The mean spherical powers of subjective refraction, Closed-view and Open-view were determined to be $-2.125{\pm}2.155D$, $-2.146{\pm}1.907D$, $-2.117{\pm}2.121D$, respectively. The mean spherical equivalent values of subjective refraction, Closed-view and Open-view were determined to be $-2.362{\pm}2.204D$, $-2.391{\pm}1.967D$, $-2.366{\pm}2.162D$, respectively. The results showed that the refractive errors as measured by the Closed-view and Open-view were found to be similar to the subjective refraction in all components.

  • PDF

A study on design of spherical hob for internal gear hobbing (내접치차 가공용 구형 호브의 설계에 관한 연구)

  • 박천경;박동삼
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.6
    • /
    • pp.1312-1319
    • /
    • 1988
  • Internal gear is the important part of the planetary reduction gear system. This study aims at developing the numerical analysis method for design of spherical hob to manufacture internal gear. Methods of calculation of hob tooth profile, generating tooth profile and tooth profile errors such as the errors of pressure angle, tooth thickness and pitch of spherical hob must be made smaller than those of standard tooth profile. And, the smaller the pressure angle and the number of equivalent pinion tooth become, the larger the tooth profile errors are. One design example of spherical hob is proposed.

Determination of Two Dimensional Axisymmetric Finite Element Model for Reactor Coolant Piping Nozzles (원자로 냉각재 배관 노즐의 2차원 축대칭 유한요소 모델 결정)

  • Choi, S.N.;Kim, H.N.;Jang, K.S.;Kim, H.J.
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.432-437
    • /
    • 2000
  • The purpose of this paper is to determine a two dimensional axisymmetric model through a comparative study between a three dimensional and an axisymmetric finite element analysis of the reactor coolant piping nozzle subject to internal pressure. The finite element analysis results show that the stress adopting the axisymmetric model with the radius of equivalent spherical vessel are well agree with that adopting the three dimensional model. The the radii of equivalent spherical vessel are 3.5 times and 7.3 times of the radius of the reactor coolant piping for the safety injection nozzle and for the residual heat removal nozzle, respectively.

  • PDF

Scotopic Pupil Size in Myopes (근시안에서 암순응상태의 동공크기)

  • Jeong, Woo-Jae;Jeon, In-Chul;Kang, Ji-Hun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.197-202
    • /
    • 2013
  • Purpose: This research was performed to measure and analyze scotopic pupil size in myopes and to figure out the factors that influence it. Methods: The pupil size of 191 healthy myopic subjects were measured with the pupillometer (Colvard pupillometer, OASIS medical, USA) in scotopic and analyzed with the age, corneal size, spherical equivalent refractive error, corneal curvature. In addition, it was compared with the measurements of intra-examiner and inter-examiner to verify reproducibility of pupillometer. Results: The mean (${\pm}$SD) scotopic pupil size was $6.64{\pm}0.68$ mm (range, 5.00~8.00 mm), the lower age and the larger corneal size, The bigger the pupil size. The lower spherical equivalent refractive error and steepper corneal curvature tends to be smaller. The reproducibility of intra-examiner and inter-examiner in pupillometer showed the reliability highly (Guttman splithalf point > 0.91). Conclusions: The pupil size associated with age, corneal size, spherical equivalent refractive error and corneal curvature in scotopic condition. It can refer to prevent inconvenience that may occur RGP contact lenses, cataract surgery and refractive surgery.

Analysis on Ocular Components Variation with the Difference of Both Refractive Errors (양안 굴절이상 차이에 의한 안광학상수 변화도 분석)

  • Lee, Hae-Jung;Lee, Eun-Hee;Jung, Mi-A
    • Journal of Digital Convergence
    • /
    • v.14 no.11
    • /
    • pp.435-440
    • /
    • 2016
  • The aim of study was to provide the preliminary data to find out characteristics of the difference between both refractive errors through analysis of ocular components variation. We measured spherical equivalent power and corneal radius with KR-8800, and axial length and anterior chamber depth with IOL Master, and the difference of measuring values between the right eye and left eye was applied as the absolute values in 100 adults aged 20~59 years. In all participants, the most common results showed that spherical equivalent power was $-1.83{\pm}2.17D$, axial length was 23.00~24.99mm, corneal radius was 7.50~7.89mm, and anterior chamber depth was 3.60~4.09mm. There are significant correlations between both eyes in axial length and anterior chamber depth with the difference of both spherical equivalent power. The difference of both axial lengths was the biggest with the difference of both refractive errors, and shown the highest correlation. The convergence complex study through classification by aspects is needed since the difference of both refractive errors is closely related with ocular components variation, and poor visual function would be caused by the difference of both refractive errors.

A Study of Eye Refraction State on Male Old Age (노인 남성의 안굴절 상태에 대한 연구)

  • Yoo, Jae Tae;Kim, Douk Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.21-25
    • /
    • 2000
  • The old age may experienced the visual acuity decrease according to refraction abnormality and they have a inconvenient real life style on viewing condition. So that, This study can provide the accurate information on the treatment of visual acuity of a male old ages by test of eye refraction state. The test was performed the visual acuity test by the object and subject methods.and the subjects was the Korean male over 55 old age. The eye types were 0.8 % positive for emmetropia, 15.2 % for myopia, and 84 % for hyperopia, respectively. The abnormal refraction eyes were 1.3 % positive for simple myopic astigmatism, 13.9 % for compound myopic astigmatism. 3.4 % for simple hyperopia and 3.1 % for simple hyperopic astigmatism, 77.5 % for mixed astigmatism, respectively. The asix of astigmatisms were 62% positive for against-the-rule astigmatism, 6% for with-the rule astigmatism, and 32 % for oblique astigmatism, respectively. On the total myopic spherical power, the $-0.50{\leq}$spheric equivalent <-2.00 diopter was 84.3%, the $-2.00{\leq}$spherical equivalent <-6.00.diopter was 15.7%. On the total hyperopic spherical power, the $+0.50{\leq}$spheric equivalent <+2.00 diopter was 74.2%, the $+2.00{\leq}$spherical equivalent <+6.00 diopter was 24.8%, and anything over the +6.00 diopter was 1%. On the astigmatic power, the $0.5{\leq}$cylinder <1.00 diopter was 54.1%, the $1.00{\leq}$cylinder <2.00 diopter was 32.4%, and anything over the 2.00 cylinder diopter was 13.5%.

  • PDF

Analysis Torque Characteristic and Improved Efficiency of Permanent Magnet Multi-D.O.F. Spherical Motor (영구자석형 다자유도 구형전동기의 토크특성 분석과 효율 향상에 대한 연구)

  • Lee, Ho-Joon;Kang, Dong-Woo;Park, Hyun-Jong;Hong, Kyung-Pyo;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.814-815
    • /
    • 2011
  • A surfaced permanent magnet spherical motor is capable of operating as three degree of freedom that used for the joints of the robot's arm, leg, and eyes. Ongoing research like new concept is essential part of motor field, it will make a great contribution in the future the overall portion of the motor, is becoming expected. The author analysis torque characteristics in spherical motor with state of rotating and positioning. And future design direction is smaller motors with equivalent or higher output. Solutions as torque and efficiency improvements are selecting the core with special processing type like powder metallurgy materials. Their special characteristic is high permeability and low eddy current losses at high speed, so improved the torque and efficiency.

  • PDF

Optimization of the Number and Position of Far Field Sources in Using the Equivalent Source Method (등가음원법에서의 원거리음원의 위치와 개수의 최적화 연구)

  • 백광현
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.10
    • /
    • pp.743-750
    • /
    • 2003
  • The equivalent source method(ESM) is used for the calculation of the internal pressure field for an enclosure which can have arbitrary boundary conditions and nay include internal objects which scatter the sound field. The advantage of using ESM is that it requires relatively low computing cost and is easy to model the internal diffracting objects. Typical ESM modeling uses two groups of equivalent source positions. One group includes the first order images of the source inside the enclosure. The Positions of the other group are usually on a spherical surface some distance outside the enclosure. The normal velocity on the surfaces of the enclosure walls is evaluated at a larger number of positions than there are equivalent sources. The sum of the squared difference between this velocity and the expected is minimized by adjusting the strength of the equivalent sources. This study is on the optimal far field sources positions when using the equivalent source method. In general, the far field sources are evenly distributed on a surface of a virtual sphere which is centered at the enclosure with a sufficiently large radius. In this study. optimal far field source locations are searched using simulated annealing method for various radii of spheres where far field sources are located. Simulation results showed that optimally located sources with adequate distance away from the enclosure center gave better result than sources with even distribution even with a smaller number of far field sources.

A study on the Optimal Far field Source locations in the Acoustic Modelling using Equivalent Source Method (등가소스법을 이용한 실내 음장 모델링에서의 원방 소스 최적화 연구)

  • Baek, Kwang-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.216-221
    • /
    • 2001
  • The equivalent source method(ESM) is used for the calculation of the internal pressure field for an enclosure which can have arbitrary boundary conditions and may include internal objects which scatter the sound field. The advantage of using ESM is that it requires relatively low computing cost and is easy to model the internal diffracting objects. In the ESM modelling, some of the equivalent positions are chosen to be the same as the first order images of the source inside the enclosure, some are positioned on a spherical surface some distance outside the enclosure. The normal velocity on the surfaces of the enclosure walls is evaluated at a larger number of positions than there are equivalent sources. The sum of the squared difference between this velocity and the expected is minimized by adjusting the strength of the equivalent sources. This study is on the optimal equivalent source positions, the far field sources. Typically, the far field sources are evenly distributed on a surface of a virtual sphere which is centered at the enclosure with a sufficiently large radius. In this study, optimal far field source locations are searched using simulated annealing method and simulation results showed that optimally located sources gave better accuracy even with a smaller number of far field sources.

  • PDF

Effects of photostrictive actuator and active control of flexible membrane structure

  • Gajbhiye, S.C.;Upadhyay, S.H.;Harsha, S.P.
    • Smart Structures and Systems
    • /
    • v.14 no.2
    • /
    • pp.71-83
    • /
    • 2014
  • The purpose of this paper is to investigate the flexible structure of parabolic shell using photostrictive actuators. The analysis is made to know its dynamic behavior and light-induced control forces for coupled parabolic shell. The effects of an actuator location as well as membrane and bending components under the control action have been analyzed considering the approximate spherical model. The parabolic membrane shell accuracy is being mathematically approximated and validated comparing the light induced control forces using approximate equivalent spherical shell model. The parabolic shell with kapton smart material and photostrictive actuators has been used to formulate the governing equation in the transverse direction. The Kirchhoff-Love assumptions are used to obtain the governing equation of shell with actuator. The mechanical membrane forces and bending moments for parabolic thin shell with actuator is used to analyze the dynamic effect. The results show that membrane control action is much more significant than bending control action. Photostrictive actuators oriented along circumferential direction (actuator-2) can give better control effect than actuators placed along longitudinal direction (actuator-1). The slight difference is observed between spherical and parabolic shell for a surface with focal length to the diameter ratio of 1.00 or more than unity. Space applications often have the shape of parabolical shells or shell of revolution, due to their required focusing, aiming, or reflecting performance. The present approach is focused that photostrictive actuators can effectively control the vibration of parabolical membrane shell. Also, the actuator's location plays an important role in defining the control force.