• 제목/요약/키워드: Speed-up test

검색결과 711건 처리시간 0.034초

목질(木質)의 열수추출(熱水抽出) 및 CaCl2 첨가(添加)가 목질(木質)-세멘트 보드의 휨강도(强度) 및 팽윤율(膨潤率)에 미치는 영향(影響) (The Effects of Hot Water Extraction of Wood Meal and the Addition of CaCl2 on Bending Strength and Swelling Ratio of Wood-Cement Board)

  • 안원영;신동소;최돈하
    • Journal of the Korean Wood Science and Technology
    • /
    • 제13권3호
    • /
    • pp.49-53
    • /
    • 1985
  • The effects of pre-treatments, the hot water extraction of wood meal and the addition of chemical ($CaCl_2$) to wood-cement water system on the properties of wood-cement composite such as modulus of rupture (MOR), modulus of elasticity (MOE), water sorption ratio and swelling ratio of resulting boards were studied in this experiment. The wood meals through 0.83mm(20 mesh) and retained on 0.42mm(35 mesh) screen were prepared from Pinus densiflora S. at Z. and Larix leptolepsis G. For hot water extraction, 500 grams of wood meal for each species were heated to boiling with 1,500ml of distilled water in 2-liter beaker for 6 hours. Every 2 hours, the wood meals were washed with boiling distil1ed water and reheated to boiling again. After 6 hours boiling, the boiled wood particles were collected by pouring this particles on 200 mesh screen. The collected particles then washed twice with hot distilled water and dried for 24 hours in an oven at $109{\pm}20^{\circ}C$. A mixture of 663.4 grams of cement with 331.7 grams of wood meal based on oven-dry weight were dry-mixed in a plastic vessel. The mixture was kneaded with 497.6ml of distilled water in the ratio of 1.5ml of water to a gram of wood meal. To add calcium chloride to the mixture as an accelerator, $CaCl_2$ 4% solution by weight per volume, was added to pine-or larch-cement board in the ratio of 3% to cement weight. To set wood-cement board, this mixture was clamped at 30cm ${\times}$ 30cm, in thickness of 1.5cm for 3 days at room temperature, declamped and then placed at open condition for 17 days. The target density was 1.0. The four specimens sized to 5cm in width and 28cm in length were used for MOR and MOE test for each treatment. After MOR test, the tested specimens were cut to the size of 5cm ${\times}$ 5cm for water sorption and swelling test. The twenty specimens used to measure the water sorption ratio (soaking 24 hours) and ten of these were used for swelling ratio measurement The results obtained were as follows: 1) Larch was not suitable for wood-cement boards because larch-cement board developed no strength, but pine showed 97.9kg/$cm^2$ by hot water extraction. 2) To increase MOR, hot water extraction was more effective than the addition of $CaCl_2$ in pine and larch because the $CaCl_2$ addition was seemed to speed up the ratio of cement hydration without reacting with the wood substances. 3) The water sorption ratio was lowered by the addition of $CaCl_2$ to wood-cement system because the chemical additive accelerated the rate of cement hydration. 4) In pine-cement board, the swelling ratio from 0.37 to 0.42 percent was observed in length and the swelling ratio from 0.88 to 2.0 percent in thickness. As a rule, the swelling ratio of wood-cement board was very low and the swelling ratio in thickness was higher than in length.

  • PDF

혁신형 중소기업의 재무적 제약과 배당스무딩간의 관계 (The Relations between Financial Constraints and Dividend Smoothing of Innovative Small and Medium Sized Enterprises)

  • 신민식;김수은
    • 중소기업연구
    • /
    • 제31권4호
    • /
    • pp.67-93
    • /
    • 2009
  • 본 연구는 1999년 1월 1일부터 2007년 12월 31일까지 한국거래소의 유가증권시장과 코스닥시장에 상장된 혁신형 중소기업을 대상으로 재무적 제약과 배당스무딩간의 관계를 실증분석 하였으며, 주요한 분석결과는 다음과 같다. 기업들은 목표 배당성향을 가지고 있으며, 실제 배당성향이 목표 배당성향에서 이탈하면 다시 배당지급을 부분적으로 조정한다. 배당조정속도는 Lintner(1956)의 배당조정모형의 핵심변수인 전기 주당배당과 당기 주당이익을 사용하여 거의 대부분 측정할 수 있으며, 잔여배당이론과 그 이후에 등장한 배당신호이론, 대리인이론, 케이터링 이론 및 거래비용이론에 관한 대용변수들은 배당조정속도에 부분적으로 영향을 미친다. 그리고 전기 주당배당은 당기 주당이익보다 배당조정속도에 더 큰 영향을 미치는데, 이는 기업들이 특별한 이유가 없는 한 전기 주당배당 수준을 장기적으로 유지하는 안정적인 배당정책을 선호한다는 증거가 된다. 혁신형 중소기업은 비혁신형 중소기업보다 배당조정속도가 더 빠르다. 혁신형 중소기업은 R&D 투자에 따른 미래의 성장성과 수익성을 담보로 하여 장기적으로 안정적인 배당정책을 유지할 수 있다. 다시 말해, 혁신형 중소기업은 배당지급이 목표 배당성향에서 이탈하더라도, R&D 투자에 따른 미래의 성장성과 수익성을 담보로 하여 목표 배당성향을 향하여 배당지급을 신속하게 조정하여 배당스무딩을 효과적으로 달성할 수 있다. 그리고 혁신형 중소기업 중에서도 재무적 비제약 기업은 재무적 제약 기업보다 배당조정속도가 더 빠르다. 이는 재무적 비제약 기업일수록 자본시장을 통한 외부 자금조달이 용이하기 때문에 주당배당을 신속하게 조정한다는 증거가 된다. 따라서 자본시장 접근성이 용이하여 재무적 제약을 적게 받는 기업일수록 외부 자금조달이 용이하기 때문에 배당지급을 더 신속하게 조정함으로써 배당스무딩을 더 효과적으로 달성할 수 있다. 그리고 중소기업청이 정책적 목적으로 분류한 혁신형 중소기업(벤처기업, 이노비즈기업, 경영혁신형기업)은 비혁신형 중소기업보다 배당조정속도가 더 빠르다. 중소기업청에서 정책적 목적으로 분류한 혁신형 중소기업은 신용보증지원, 정책자금지원, 조세혜택, 공공입찰 우선권 부여 등과 같은 다양한 정책적 혜택으로 인해 재무적 제약을 적게 받기 때문에 배당지급을 더 신속하게 조정할 수 있다. 결론적으로, 한국거래소의 유가증권시장과 코스닥시장에 상장된 혁신형 중소기업은 비혁신형 중소기업보다 배당조정속도가 더 빠르고, 혁신형 중소기업 중에서도 재무적 비제약 기업은 재무적 제약 기업보다 배당조정 속도가 더 빠르다. 다시 말해, 중소기업 중에서도 R&D 집중도가 높은 혁신형 중소기업은 R&D 투자에 따른 미래의 성장성과 수익성을 담보로 하여 배당스무딩을 신속하게 할 수 있고, 혁신형 중소기업 중에서도 자본시장 접근성이 좋은 기업은 재무적 제약을 적게 받기 때문에 배당스무딩을 더 신속하게 할 수 있다. 따라서 중소기업 경영자는 R&D 집중도를 증가시키고 자본시장 접근성을 높여 재무적 제약을 회피함으로써 신속한 배당스무딩을 통해 장기적으로 안정적인 배당정책을 유지할 수 있다고 생각한다. 그리고 중소기업청이 정책적 목적으로 분류한 혁신형 중소기업(벤처기업, 이노비즈기업, 경영혁신형기업)의 경우에도 배당조정속도가 비혁신형 중소기업보다 더 빠르게 나왔다. 이러한 결과는 배당정책의 측면에서 중소기업청의 혁신형 중소기업 정책을 지지하는 실증적인 증거가 된다.

글래스 아이오노머 이장재와 복합레진간의 결합강도에 관한 연구 (A STUDY ON THE BOND STRENGTHS BETWEEN GLASS IONOMER CEMENT BASES AND COMPOSITE RESINS)

  • 김민희;김신;정태성
    • 대한소아치과학회지
    • /
    • 제26권3호
    • /
    • pp.520-527
    • /
    • 1999
  • 본 연구는 현재 널리 쓰이고 있는 sandwich technique을 임상에 적용함에 있어서, GIC 이장재에 대한 이중중합형 레진과 비교적 근래에 소개된 compomer의 결합력을 측정하여 기존의 광중합형, 화학중합형 복합레진과 비교하고, 가장 우수한 결합력을 보이는 glass ionomer-composite resin의 조합을 밝혀내고자 시도되었다. 이장용 재료로는, 광중합형 GIC인 Vitrebond와 화학중합형 GIC인 Ketac-fil을 사용하였으며, 이 두 가지의 이장재에 대해, 광중합형 복합 레진인 Z-100, 화학중합형 복합 레진인 Clearfil, compomer인 Dyract, 그리고 이중중합형 복합 레진인 Bis-core를 축조하여 각 군당 10개씩, 총 80개의 시편을 제작하였다. 제작된 시편은 $37^{\circ}C$의 증류수에 24시간동안 보관한 후, full load scale 50kg, cross-head speed 1mm/min 조건의 만능 시험기에서 그 전단결합강도를 측정하였으며 실험결과는 student t-test로 검정하였다. 본 연구의 결과는 다음과 같다. 1. Vitrebond를 이장재로 사용한 경우, Z-100이 가장 낮은 결합강도를 보였으며, 나머지 세 재료는 결합력의 차이를 보이지 않았다(P>0.05). 2. Ketac-fil을 이장재로 사용한 경우, Clearfil이 가장 높은 결합강도를 보였고, Dyract, Bis-core가 중등도의 결합강도를, Z-100이 가장 낮은 결합강도를 보였다(P<0.05). 3. Clearfil은 Vitrebond 상방에서는 타 재료들과 비슷한 결합강도를 보였으나, Ketac-fil 상방에서는 가장 강한 결합강도를 보임으로써, GIC 이장재의 종류에 따른 결합력의 차이를 보였으나 (P<0.05), 나머지 세 재료의 경우에는 차이를 보이지 않았다(P>0.05). 4. Vitrebond를 사용할 때보다 Ketac-fil을 이장재로 사용할 때, 상부에 축조되는 복합레진의 종류에 따른 결합력의 차이가 더 크게 나타났다(P<0.05).

  • PDF

산부식 전처리에 따른 2단계 자가부식 접착제의 연마 법랑질에 대한 미세인장결합강도 (The micro-tensile bond strength of two-step self-etch adhesive to ground enamel with and without prior acid-etching)

  • 김유리;김지환;심준성;김광만;이근우
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.148-156
    • /
    • 2008
  • 자가부식 접착제는 사용하기 쉽고, 술식 민감성이 적은 장점이 있으나 특히 산도가 약한 자가부식 접착제의 법랑질에 대한 결합력은 논란이 되고 있다. 본 연구에서는 2단계 자가부식 접착제인 Clearfil SE Bond (Kuraray, Okayama, Japan)의 연마 법랑질에 대한 미세인장 결합강도를 측정하여 3단계 산부식수세 접착제인 Scotchbond Multi-Purpose (3M ESPE, St. Paul, MN, USA) 및 1단계 자가부식 접착제인 iBond (Heraeus Kulzer Gmbh, Hanau, Germany)의 결합강도와 비교하고자 하였고, 2단계 자가부식 접착제에 산부식 전처리를 시행하는 것이 법랑질에 대한 결합강도를 높일 수 있는지 알아 보고자 하였다. 실험군은 2단계 자가부식 접착제인 Clearfil SE Bond만 사용한 비산부식 군과 35% 인산 (Scotchbond Etchant, 3M ESPE)으로 산부식 후 Clearfil SE Bond를 사용한 산부식 군, 그리고 1단계 자가부식 접착제인 iBond를 사용한 군으로 나누었다. 대조군은 3단계 산부식수세 접착제인 Scotchbond Multi-Purpose를 사용한 군으로 정하였다. Bovine 전치의 순면을 십자가형으로 4등분하여 각 군으로 무작위로 배분하였다. 각 치아의 순면을 800-grit 실리콘 카바이드 지로 연마한 후 삭제된 법랑질면에 제조사의 설명서에 따라 각 군의 접착제를 적용하고 Light-Core (Bisco)로 적층 충전하였다. 시편은 $37i{\acute{E}}$, 증류수에 일주일 동안 보관한 후 low speed precicion diamond saw (TOPMENT Metsaw-LS, R&B, Daejeon, Korea)를 이용하여 약 $0.8{\times}0.8mm$ 단면이 되도록 시편을 절단하여 미세시편을 제작하였다. 일주일마다 증류수를 교환하면서 한 달, 세 달 동안 $37i{\acute{E}}$, 증류수에 미세시 편을 보관한 후 각각의 미세인장결합강도를 측정하였다. 미세인장결합강도 (MPa)는 파절 시에 가해진 힘 (N)을 접착면적 ($mm^2$)으로 나누어 계산하였다. 접착계면에서의 파절 양상은 실물현미경 (Microscope-B nocular, Nikon)을 이용하여 분류하였다. 미세인장결합강도에 대한 통계분석은 one-way ANOVA를 이용하여 유의수준 5%에서 검정하였고, 사후감정은 Least Significant Difference 방법을 이용하였다. 중합 후 1개월 뒤 측정된 각각의 접착제의 평균 미세인장결합강도는 유의수준 5%에서 모든 접착제 간에 유의한 차이가 없었다. 3개월 뒤 측정된 각각의 접착제의 평균 미세인장결합강도는 유의수준 5%에서 iBond 와 Clearfil SE Bond 비산부식 군과 Scotchbond Multi- Purpose 간에는 각각 유의한 차이가 없었다. 본 연구에서는 2단계 자가부식 접착제인 Clearfil SE Bond의 연마 법랑질에 대한 미세인장결합강도가 3단계 산부식수세 접착제인 Scotchbond Multi-Purpose 와 비교하여 유의한 차이가 없었으며 (P>0.05), 3개월 후의 결과에서 Clearfil SE Bond 비산부식 군의 미세인장결합강도가 Clearfil SE Bond 산부식 군보다 유의하게 낮았다 (P<0.05). 즉 35% 인산으로 산부식 전처리를 시행한결과 Clearfil SE Bond 의 법랑질에 대한 결합강도가 증가하였다.

치아의 활주 이동시 브라켓 폭이 브라켓과 호선 사이의 마찰력에 미치는 효과 (The effect of bracket width on frictional force between bracket and arch wire during sliding tooth movement)

  • 최원철;김태우;박주영;곽재혁;나효정;박두남
    • 대한치과교정학회지
    • /
    • 제34권3호
    • /
    • pp.253-260
    • /
    • 2004
  • 치아의 활주 이동시 교정용 브라켓과 호선 사이의 마찰력은 많은 요인들, 예를 들면 브라켓과 호선의 크기, 형태 그리고 재료, 결찰방법 그리고 브라켓-호선간 각도 등과 관련이 있다. 이런 요인들 대부분에 관하여 명확한 결론이 내려져 있지만 브라켓 폭이 마찰력에 미치는 효과에 관해서는 논란이 있다. 이번 연구는 임상에서와 비슷한 모의 치아 이동시 브라켓 폭이 발생되는 마찰력의 양에 미치는 효과를 조사하기 위해 고안되었다. 폭이 다른 세 가지 브라켓 $(0.018{\times}0.025\;standard)$ 즉 좁은 것 (2.40mm), 중간 것 (3.00mm), 그리고 넓은 것(4.25mm) 등을 $0.016{\times}0.022$ 스테인레스 스틸 호선과 함께 사용하였다 세 가지 브라켓-호선 조합들은 분속 0.5mm로 4분 동안 장치 에서 움직이도록 하였고 각각 7회씩 반복 측정하였다. 생물학적인 상태를 재현하기 위해 치 아 치조 모형은 치근막과 유사한 탄성을 갖는 재료를 이용하는 간접법으로 제작되었다. 게다가 결찰력의 효과를 최소화하기 위하여 브라켓에 레진을 덧붙여서 고무로 결찰함으로써 브라켓 폭의 차이를 보상해주었다. 결과는 다음과 같다: 1. 각 브라켓-호선 조합의 최대 마찰력은; 좁은것(2.40mm): $m4.69gmf$ 중간것 (3.00mm): $72.7\pm54.98gmf$ 넓은것(4.25mm): $72.5\pm94.54gmf$ 2. 호선이 브라켓 슬롯을 지나서 나아갈수록 마찰력은 증가하였다. 3. ANOVA 사후검정 결과 임상과 비슷한 모의 실험에서 브라켓 폭은 마찰력에 아무런 영향을 미치지 않았다(p>0.05).

탈지대두박(脫脂大豆粕)에서 추출(抽出)한 분리대두단백(分離大豆蛋白)의 식품학적(食品學的) 성질(性質) (Functional Properties of Soy Protein Isolates Prepared from Defatted Soybean Meal)

  • 변시명;김철진
    • 한국식품과학회지
    • /
    • 제9권2호
    • /
    • pp.123-130
    • /
    • 1977
  • 동방유량(東邦流糧)에서 공급(供給)받은 저변성(低變成) 탈지대두박(脫脂大豆粕)을 0.02N NaOH액(液)으로 추출(抽出)하여 Soy Protein Isolate (SPI)의 수율(收率)을 증류수나 염용액(鹽溶液)으로 추출(抽出)할때 보다 높이는 과정(過程)(84 % 수율(收率))을 확립(確立)하였으며 제조(製造)된 SPI는 92.1 %의 단백질(蛋白質)을 함유(含有)하였다. SPI를 $70^{\circ}C$에서 moisture heat를 하면 80분간(分間)에 5 %의 변성(變性)이 일어났으나 $95^{\circ}C$에서는 20분(分) 처리(處理)에 의(依)하여 95 %의 변성(變性)이 일어났다. SPI의 alkali 현탄액 (dope solution)은 SPI의 농도(濃度) 15 %, NaOH 농도(濃度) 0.6 %일때 7분(分)만에 60 poises를 나타내고 계속 안정(安定)된 점도(粘度)를 유지하였다. NaOH의 농도(濃度)가 0.9 %일 때는 시간(時間)이 경과(經過)함에 따라 점도(粘度)는 증가(增加)하였다가 감소(減少)하는 경향(傾向)을 보였다. syringe needle (dia. 0.3 mm)로서 모의(模擬) 실험(實驗) 결과(結果) 점도(粘度)가 $28^{\circ}C$에서 60 Poises일때 가장 적합한 단백질섬유(蛋白質纖維)의 texture를 보여주었다. 가열(加熱)에 의(依)한 SPI의 gelation은 8 %이상(以上)의 SPI농도(濃度)일 때 gel이 형성(形成)되기 시작하였으며 $100^{\circ}C$까지 안정(安定)한 gel을 형성(形成)하였고 SPI의 농도(濃度)가 12 %일때 $120^{\circ}C$에서 30분(分) 가열(加熱)에 의(依)하여 20,000 Poises의 좋은 점도(粘度)를 가졌으나 $120^{\circ}C$이상에서는 gel의 continuity가 떨어져 과립상(果粒上)의 gel이 생성(生成)되었다. SPI의 유화력(乳化力)은 pH가 8.7, NaCl의 농도(濃度)가 2 %일때 가장 큰 유화력(乳化力)을 나타냈다. milk casein과 비교(比較) 실험(實驗) 결과(結果) 유화력(乳化力)은 약간 낮았으나 염(鹽)이 존재(存在)하는 경우는 근사한 유화력(乳化力)을 보였다. 그러나 SPI의 foaming capacity는 foaming stability 면(面)에서 egg albumin이나 milk casein과 비교(比較)하여 양호(良好)한 결과(結果)를 보여주었다.

  • PDF

고준위 방사성 폐기물 처분 시스템 실증 실험용 KENTEX 장치에서의 열-수리-역학 연동현상 해석 (Coupled T-H-M Processes Calculations in KENTEX Facility Used for Validation Test of a HLW Disposal System)

  • 박정화;이재완;권상기;조원진
    • 방사성폐기물학회지
    • /
    • 제4권2호
    • /
    • pp.117-131
    • /
    • 2006
  • 한국의 고준위폐기물 기준 처분 시스템의 공학적 방벽에서의 T-H-M(Thermo-Hydro-Mechanical) 거동 실증을 위한 KENTEX(KAERI Engineering-scale T-H-M Experiment for Engineered Barrier System)실험 장치를 대상으로 열-수리-역학 연동현상 해석을 하여 온도, 포화도 및 응력의 변화를 예측하였다. 그리고 이들 변수와 열-수리-역학의 연동현상에 사용된 세물성법칙인 탄성물성법칙, 공극탄성 물성법칙 및 공극탄성-소성 물성법칙과의 관계를 분석하였다. 열-수리-역학 연동현상을 계산하는 데는 상용 유한요소 코드인 ABAQUS를 사용하였다. 열 계산에서 벤토나이트 내 온도는 히터 가열 후 초기에는 급격히 증가하다가 얼마의 시간이 경과한 후에는 거의 일정한 값에 도달하였다. 이 도달시간은 약 37.5일로 반경방향의 모든 지점(H=0.68m 일때)에서 정상상태에 도달한 것을 알 수 있었다. 즉, 히터와 벤토나이트 경계면에서는 $90^{\circ}C$, 벤토나이트와 외부 셀 경계면에서는 약 $70^{\circ}C$를 유지하였다. 열-수리-역학 연동현상 계산에서 시간에 따른 벤토나이트 포화도는 탄성 물성법칙, 공극탄성 물성법칙 및 공극탄성-소성 물성법칙의 세 경우 모두 거의 차이가 없었다. 열-수리-역학 계산 결과와 수리-역학 계산 결과의 비교에서 온도의 증가는 탄성 물성법칙 및 공극탄성 물성법칙 각각에 대해 시간이 경과함에 따라 포화도가 증가함을 초래해 포화가 빨리 진행됨을 알 수 있었다. 특히 히터에 가까운 쪽에서는물이 침투하고 있는 쪽 보다 포화도 증가가 큰 것으로 나타나 벤토나이트가 물로 포화되기 전의초기상태가 온도의 영향을 많이 받는 것을 알 수 있었다. 또한 응력은 세 물성 법칙 모두 시간의 경과에 따라 증가하는 경향을 보이나 탄성 물성법칙의 경우가 다른 두 경우보다 현저한 변화를 보이는데 이는 변형율이 탄성한계를 넘어서도 계속 작용하여 공극비 변화를 고려한 다른 두 물성법칙과 차이가 있음을 나타내고 있다. 그러나 공극탄성 물성법칙 및 공극탄성-소성 물성법칙의 경우에 열-수리-역학 계산 결과와 수리-역학 계산 결과를 비교하면 시간이 경과함에 따라 응력은 증가하지만 온도의 변화에 따른 서로의 응력의 차이는 작은 것을 알 수 있다. 즉 온도변화의 영향보다는 시간에 따른 포화도 변화의 영향이 더 큰 것으로 생각된다. 따라서 벤토나이트의 열-수리-역학 연동현상 해석에서 벤토나이트는 온도의 증가로 포화가 빨라지고, 포화도 증가는 응력을 증가시키는 결과를 보이므로 공극비, 열팽창 및 팽윤압 등의 영향을 받고 있는 것으로 이해된다. 그래서 벤토나이트의 열-수리-역학 연동현상 해석에서 벤토나이트는 공극비, 열팽창 및 팽윤압 등의 영향을 받으므로 탄성과 소성을 동시에 고려할 수 있는 물성법칙을 선택하는 것이 바람직하다.

  • PDF

Chlorhexidine 처리가 상아질 접착제의 미세인장결합강도에 미치는 영향 (EFFECT OF CHLORHEXIDINE ON MICROTENSILE BOND STRENGTH OF DENTIN BONDING SYSTEMS)

  • 오은화;최경규;김종률;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제33권2호
    • /
    • pp.148-161
    • /
    • 2008
  • 본 연구는 상아질 혼성층의 교원섬유를 가수분해하는 효소인 MMPs (Matrix metalloproteinses)의 억제제로 알려진 chlorhexidine (CHX)을 적용 후 결합강도를 측정하였으며, 이를 각각 열순환 처리 후 결합강도를 측정하였다. 또한 주사전자현미경으로 접착계면에서의 파괴 양상을 비교 분석하였다. 우식이 없는 발거한 32개의 제3대구치의 교합면 상아질을 노출시키고 GI그룹에서는 dentin conditioner를 처리 후 2% chlorhexidine을 적용시키고, 산부식 접착제 그룹에서는 인산 산부식을 시행하고 2% chlorhexidine을 적용 후 3단계 산부식형 상아질 접착제 (Scotchbond Multipurpose, SM), 2단계 산부식형 상아질 접착제 (Single Bond, SB)를 도포하고, 자가부식 접착제 그룹에서는 2% chlorhexidine 적용 후 자가부식 상아질 접착제 (Clearfil Tri-S, TS)를 도포한다. 이후 복합 레진 (Z-250)과 GI (Fuji-II LC)를 충전한 시편을 $1\;mm^2$의 단면을 갖는 beam으로 제작하여 열순환 하지 않거나, 10,000회 열순환 ($5\;{\sim}\;55^{\circ}C$)하였다. Universal testing machine (EZ-test; Shimadzu, Japan)에서 cross head speed 1 mm/min로 인장력을 가하여, 미세인장결합강도를 측정하였다. 실험 결과는 유의수준 0.05 level에서 two-way ANOVA를 이용하여 통계분석하였다. 그 후 파절된 시편의 파괴 양상을 현미경 (SEM)으로 관찰하여 다음과 같은 결론을 얻었다; 1. 2% CHX을 적용한 모든 실험군에서 상아질과의 미세인장결합강도가 증가하였고, 열순환은 상아질과의 미세인장결합강도를 감소시켰다 (P > 0.05). 2. CHX 적용 후 열순환 한 군은 CHX을 적용하지 않고 열순환한 군에 비하여 상아질과의 미세인장결합강도가 높았으며, 특히 GI와 TS군에서 유의한 차이를 나타내었다 (P < 0.05). 3. 파괴 양상 분석 결과, 혼성층에서의 접착성 파괴를 보이며, CHX을 적용하면 혼성층 기저부에서 상부로 파괴 부위가 옮겨가는 양상을 나타내었다. 이상의 연구 결과를 토대로, MMPs 억제제인 2% CHX은 글래스 아이오노머 시멘트와 상아질 접착제의 초기 미세인장결합강도에는 영향을 미치지 않으며, CHX 적용이 접착내구성을 유지하는데 도움이 되었다.

컴퓨터 및 스마트폰 사용이 근골격계질환으로 인한 업무능력 저하에 미치는 영향 : 근골격계 질환의 매개효과 (The Effect of using Computer & Smart-phone on Decreased Work Efficiency due to Musculoskeletal Disorders ; Mediating Effect of Perceived Musculoskeletal Disorders)

  • 박종호
    • 유통과학연구
    • /
    • 제14권3호
    • /
    • pp.55-62
    • /
    • 2016
  • Purpose - Average using time of smart-phone for Korean people is 3 hours 39 minutes and most people who are using a computer at home and their workplace can be affected over force to neck and shoulder due to unstable body posture. musculoskeletal disorders which caused by unstable body posture can affect strongly to decrease work efficiency. So this research is designed to measure the effect of using computer & smart-phone on decreased work efficiency due to musculoskeletal disorders and mediating effect between decreased work efficiency and musculoskeletal disorders. Research Design, Data, and Methodology - The author has developed a questionnaire with 6 hypothesis on the basis of previous research result with 5 constructs. The questionnaires were also made by interview and E-mail. 300 copies of questionnaires were distributed and 282 questionnaire were used for the analysis as valid data responses. SPSS ver.21.0 were used and made Cronbach's α and reliability test, correlation, Baron & Kenny 3 step mediated regression analysis. Result - Cronbach's α shows 0.770~0.954 and C.R. is 0.963~0.997 which is higher than 0.7. and AVE was 0.867~0.933. So the data are all acceptable condition. Using for a long time of a computer & smart-phone has a positive effect on musculoskeletal disorders. This means, it can cause musculoskeletal disorders if people use a computer & smart-phone for a long time due to unstable body posture. And musculoskeletal disorders can effect strongly decrease work efficiency. This study also found out that a long time of using computer can cause musculoskeletal disorders rather than using smart-phone a long time. To check mediate effect of musculoskeletal disorders between using a computer & smart-phone and Decreased Work Efficiency, author used 3-step mediated regression analysis of Baron & Kenny (1986). Using a computer for a long time mediate partially and using a smart-phone for a long time mediate completely. This means that using a smart-phone a long time is not the actual reason to decrease work efficiency. But using level of smart-phone is increasing rapidly day by day. So we need to make additional research about this matter seriously. Conclusion - Nowadays, people can not live on without a computer & smart-phone even a moment. But, using a computer for a long time will affect to cause musculoskeletal disorders and it will effect strongly to decrease work efficiency. Before, we thought over that musculoskeletal disorders were diseases of elder people. But, we found out from this study that musculoskeletal disorders can be happen to any people, even children, or workers in heavy industry or engaged in brain work. So we need to be careful when we use a computer for a long time. People also need to be careful to keep correct body posture when using both a computer and smart-phone since a smart-phone became more popular and using time level became longer. Due to increased income and living standard of people, physical growth of young people is so rapid. But the physical environment of society is not suitable for them since it can not follow up the speed of growth. Suitable work table is very important to prevent musculoskeletal disorder which can affect decrease work efficiency. For a person, a society or country, increased productivity is very important since it can directly connected to the job satisfaction. Education and reeducation for the people is also important, but to teach them how to keep good condition of health will be more important since it can increase the quality of work efficiency and quality of life. Computer and Smart-phone is one the best invention of modern society, but it can cause mental and physical disease which can affect decrease work efficiency and productivity. So it is necessary to observe attentively for the situation continually.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF