Study on Following of Parmeter ${\alpha}$ of 2-DOF PID Controller Using Fuzzy Algorithm

  • Lee, Sang-Min;Cho, Yong-Sung;Park, Jong-Oh;Choo, Yeon-Gyu;Lim, Young-Do
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.307-311
    • /
    • 2003
  • 2-mass system is generally used as controller of the variable-speed to transfer electromotion power to mechanical load such as industrial robot, driving parts of electric vehicle, rolling machine system of steel plant and driving parts of elevator. In this case, PI controller is often used as a velocity controller because of simplicity of system. But PI control algorithm is not enough for obtaining the control characteristics required for this system. To solve this problem, 2-mass system based on the PID controller derives the optimum PID parameters by pole assignment and estimation of the ITAE performance index. In this case, the system have tenacious properties about disturbance, but it causes extreme overshoot and vibration because of rapidly output of controller in early transient response about desired value. And if speed control system is applied by 2-DOF parameter ${\alpha}$, a temporary value, we must induce most suitable parameter by complicate pole assignment and estimation of the ITAE performance index whenever ${\alpha}$ changes. In this paper, to solve this problem we suggest control algorithm to followed exactly value of ${\alpha}$ as 2-DOF parameter by using fuzzy algorithm . So, intelligence algorithm modeled by human knowledge, experience, teachability and judgment follow exact ${\alpha}$ value and it can compose the efficient 2-DOF PID controller to improve following performance, overshoot decrease.

  • PDF

Performance Simulation of a Turboprop Engine for Basic Trainer

  • Kong, Changduk;Ki, Jayoung;Chung, Sukchoo
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.839-850
    • /
    • 2002
  • A performance simulation program for the turboprop engine (PT6A-62), which is the power plant of the first Korean indigenous basic trainer KT-1, was developed for performance prediction, development of an EHMS (Engine Health Monitoring System) and the flight simulator. Characteristics of components including compressors, turbines, power turbines and the constant speed propeller were required for the steady state and transient performance analysis with on and off design point analysis. In most cases, these were substituted for what scaled from similar engine components'characteristics with the scaling law. The developed program was evaluated with the performance data provided by the engine manufacturer and with analysis results of GASTURB program, which is well known for the performance simulation of gas turbines. Performance parameters such as mass flow rate, compressor pressure ratio, fuel flow rate, specific fuel consumption and turbine inlet temperature were discussed to evaluate validity of the developed program at various cases. The first case was the sea level static standard condition and other cases were considered with various altitudes, flight velocities and part loads with the range between idle and 105% rotational speed of the gas generator. In the transient analysis, the Continuity of Mass Flow Method was utilized under the condition that mass stored between components is ignored and the flow compatibility is satisfied, and the Modified Euler Method was used for integration of the surplus torque. The transient performance analysis for various fuel schedules was performed. When the fuel step increase was considered, the overshoot of the turbine inlet temperature occurred. However, in case of ramp increase of the fuel longer than step increase of the fuel, the overshoot of the turbine inlet temperature was effectively reduced.

Design and Analysis of a Control System for Variable-Rate Application of Granular Fertilizers (입제 비료 변량 살포 제어시스템의 분석 및 설계)

  • Kim Y.H.;Rhee J.Y.;Kim Y.J.;Yu J.H.;Ryu K.H.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.3 s.116
    • /
    • pp.203-208
    • /
    • 2006
  • This study was conducted to improve the control performance of a current variable-rate controller for granular fertilizers. Simulation model was developed. Optimized proportional, integral and derivative gains were determined by simulation model using 2nd order PID gain learning algorithm, and these control gains were evaluated through the field tests. Important results of this study are as follows; 1. Principles of pre-existing variable-rate application of granular fertilizers were investigated. 2. Simulation model of a PID controller that could simulate the control system was developed by using Matlab/Simulink program. The program was to determine PID control coefficients through the simulation model and 2nd order PID gain learning algorithm. 3. PID control coefficients obtained from the simulation were applied to the developed model. When the step input was given, Maximum overshoot were 1.96%, rise time were 0.05 sec, settling time were 0.06 sec and steady state error were 0.21 % respectively. 4. The simulation model was verified through field tests. The errors of maximum overshoot were 10%, rise time were 0.11 sec, settling time were 0.40 sec and steady state error were 8% because of loads and noises. Rise time was decreased to one third of that of the pre-existing system. 5. If the speed of a fertilizing machine is $0.3{\sim}0.6\;m/s$ and the maximum rotation speed of a discharging roller is 64 rpm, rise time would be 0.26 sec and fertilizing machine would cover the distance of $0.07{\sim}0.15\;m$ with settling time of 0.4 sec, fertilizing machine would cover the distance of $0.12{\sim}0.24\;m$.

Network Adaptive Congestion Control Scheme to Improve Bandwidth Occupancy and RTT Fairness in HBDP Networks (HBDP 네트워크에서 대역폭 점유와 RTT 공정성 향상을 위한 네트워크 적응적 혼잡제어 기법)

  • Oh, Junyeol;Chung, Kwangsue
    • Journal of KIISE
    • /
    • v.42 no.9
    • /
    • pp.1162-1174
    • /
    • 2015
  • These days, the networks have exhibited HBDP (High Bandwidth Delay Product) characteristics. The legacy TCP slowly increases the size of the congestion window and drastically decreases the size of a congestion window. The legacy TCP has been found to be unsuitable for HBDP networks. TCP mechanisms for solving the problems of the legacy TCP can be categorized into the loss-based TCP and the delay-based TCP. Most of the TCP mechanisms use the standard slow start phase, which leads to a heavy packet loss event caused by the overshoot. Also, in the case of congestion avoidance, the loss-based TCP has shown problems of wastage in terms of the bandwidth and RTT (Round Trip Time) fairness. The delay-based TCP has shown a slow increase in speed and low occupancy of the bandwidth. In this paper, we propose a new scheme for improving the over shoot, increasing the speed of the bandwidth and overcoming the bandwidth occupancy and RTT fairness issues. By monitoring the buffer condition in the bottleneck link, the proposed scheme does congestion control and solves problems of slow start and congestion avoidance. By evaluating performance, we prove that our proposed scheme offers better performance in HBDP networks compared to the previous TCP mechanisms.

Determination of PID Coefficients for the Ascending and Descending System Using Proportional Valve of a Rice Transplanter

  • Siddique, Md. Abu Ayub;Kim, Wan-Soo;Baek, Seung-Yun;Kim, Yeon-Soo;Choi, Chang-Hyun;Kim, Yong-Joo;Park, Jin-Kam
    • Journal of Biosystems Engineering
    • /
    • v.43 no.4
    • /
    • pp.331-341
    • /
    • 2018
  • Purpose: This study was conducted to develop a linear Proportional-Integral-Derivative (PID) control algorithm for the ascending and descending system of a rice transplanter and to analyze its response characteristics. Methods: A hydraulic model using a single-acting actuator, proportional valve and a PID control algorithm were developed for the ascending and descending system. The PID coefficients are tuned using the Ziegler-Nichols (Z-N) method and the characteristics of unit step response are analyzed to select the PID coefficients at various pump speeds. Results: Results showed that the performance of the PID controller was superior in any condition. It was found that the highest settling time and maximum overshoot were less than 0.210 s and 5%, respectively at all pump speed. It was determined that the steady state errors were 0% in all the cases. The lowest overshoot and settling time were calculated to be nearly 2.56% and 0.205 s, respectively at the pump rated speed (2650 rpm). Conclusions: The results indicated that the developed PID control algorithm would be feasible for the ascending and descending system of a rice transplanter. Finally, it would be helpful to plant the seedlings uniformly and improve the performance of the rice transplanter.

A Driving Mechanism of Outdoor Security Robots for High Speed Applications (고속 주행용 실외 경비로봇을 위한 구동 메커니즘)

  • Jeong, Hae-Kwan;Koh, Doo-Yeol;Woo, Chun-Kyu;Kwak, Yoon-Keun
    • The Journal of Korea Robotics Society
    • /
    • v.4 no.2
    • /
    • pp.163-168
    • /
    • 2009
  • In this paper, a new driving mechanism of security robotswhich should overcome obstacles with stability even though movingin high speed is introduced. The driving mechanism has spring-based suspension and two wheels positively necessary to overcome obstacles. From the driving mechanism, it is mainly discussed how we can decrease overshoot and impulse occurred when the robot is in the process of overcoming obstacles. Finally, design parameters of the driving mechanism which guarantees stable motion while overcoming obstacles is deduced based on simulation results. Experiments are also followed to demonstrate how well the manufactured system works in its early stage of the practical use.

  • PDF

Speed Control of DC Motor Using Deadbeat Response Method (유한시간 정정응답에 의한 직류전동기의 속도제어)

  • 김영석;유완식
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1991.10a
    • /
    • pp.53-58
    • /
    • 1991
  • This paper presents the speed control of DC motor based on deadbeat response method. Since 송 deadbeat response systems are characterized by the discrete time control, the instabiliby of the systems caused by saturation and time lag problems is inevitable. In order to release these problems, we propose a compensator utilizing the predictive control so that the fast response can be also achieved in the saturation state. Experimental results demonstrated that outputs are able to settle final values in on sampling time for unsaturated reference inputs. For saturated reference inputs, outputs take one sampling time after getting free from the saturation state. Further we are able to settle the fast response with suppressed overshoot by appling the predictive control.

  • PDF

A Study on a Intelligence Depth Control of Underwater Flight Vehicle (Underwater Flight Vehicle의 지능형 심도 제어에 관한 연구)

  • 김현식;황수복;신용구;최중락
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.30-41
    • /
    • 2001
  • In Underwater Flight Vehicle depth control system, the followings must be required. First, It needs a robust performance which can get over the nonlinear characteristics due to hull shape. Second, It needs an accurate performance which has the small overshoot phenomenon and steady state error to avoid colliding with ground surface and obstacles. Third, It needs a continuous control input to reduce the acoustic noise. Finally, It needs an effective interpolation method which can reduce the dependency of control parameters on speed. To solve these problems, we propose a Intelligence depth control method using Fuzzy Sliding Mode Controller and Neural Network Interpolator. Simulation results show the proposed control scheme has robust and accurate performance by continuous control input and has no speed dependency problem.

  • PDF

Tuning-free Anti-windup Strategy for High Performance Induction Machine Drives (고성능 유도전동기 구동을 위한 자동 튜닝 Anti-windup 기법)

  • Seok Jul-Ki;Bae Sang-Gyu;Lee Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.312-315
    • /
    • 2004
  • This paper presents a tuning-free conditional integration anti-windup strategy for induction machine with Proportional-Integral (PI) type speed controller. The on/off condition of integral action is determined by the frequency domain analysis of machine torque command without a prior knowledge of set-point changes. There are no tuning parameters to be selected by users for anti-windup scheme. In addition, the dynamic performance of the proposed scheme assures a desired tracking response curve with minimal oscillation and settling time even in the change of operating conditions. This algorithm is useful in many high performance induction machine applications not to allow the oscillation and overshoot of speed/torque responses. The main idea can be extended to general applications such as chemical processes and industrial robots.

  • PDF

High performance Control of Induction Motor using Hybrid-PI Controller (Hybrid-PI 제어기를 이용한 유도전동기의 고성능 제어)

  • Choii, Jung-Sik;Ko, Jae-Sub;Kim, Kil-Bong;Chung, Dong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.260-262
    • /
    • 2006
  • This paper presents Hybrid-PI controller of induction motor drive using fuzzy control. In general, PI controller in computer numerically controlled machine process fixed gain. They may perform well under some operating conditions, but not all. To increase the robustness, fixed gain PI controller, Hybrid-PI controller proposes a new method based self tuning PI controller. Hybrid-PI controller is developed to minimize overshoot and settling time following sudden parameter changes such as speed, load torque, inertia, rotor resistance and self inductance. The results on a speed controller of induction motor are presented to show the effectiveness of the proposed gain tuner. And this controller is better than the fixed gains one in terms of robustness, even under great variations of operating conditions and load disturbance.

  • PDF