DOI QR코드

DOI QR Code

Design and Analysis of a Control System for Variable-Rate Application of Granular Fertilizers

입제 비료 변량 살포 제어시스템의 분석 및 설계

  • Kim Y.H. (Dept. of Biosystems Engineering, Seoul National University) ;
  • Rhee J.Y. (Dept. of Biosystems Engineering, Seoul National University) ;
  • Kim Y.J. (Dept. of Biosystems Engineering, Seoul National University) ;
  • Yu J.H. (Dept. of Biosystems Engineering, Seoul National University) ;
  • Ryu K.H. (Dept. of Biosystems Engineering, Seoul National University)
  • Published : 2006.06.01

Abstract

This study was conducted to improve the control performance of a current variable-rate controller for granular fertilizers. Simulation model was developed. Optimized proportional, integral and derivative gains were determined by simulation model using 2nd order PID gain learning algorithm, and these control gains were evaluated through the field tests. Important results of this study are as follows; 1. Principles of pre-existing variable-rate application of granular fertilizers were investigated. 2. Simulation model of a PID controller that could simulate the control system was developed by using Matlab/Simulink program. The program was to determine PID control coefficients through the simulation model and 2nd order PID gain learning algorithm. 3. PID control coefficients obtained from the simulation were applied to the developed model. When the step input was given, Maximum overshoot were 1.96%, rise time were 0.05 sec, settling time were 0.06 sec and steady state error were 0.21 % respectively. 4. The simulation model was verified through field tests. The errors of maximum overshoot were 10%, rise time were 0.11 sec, settling time were 0.40 sec and steady state error were 8% because of loads and noises. Rise time was decreased to one third of that of the pre-existing system. 5. If the speed of a fertilizing machine is $0.3{\sim}0.6\;m/s$ and the maximum rotation speed of a discharging roller is 64 rpm, rise time would be 0.26 sec and fertilizing machine would cover the distance of $0.07{\sim}0.15\;m$ with settling time of 0.4 sec, fertilizing machine would cover the distance of $0.12{\sim}0.24\;m$.

Keywords

References

  1. 손승용. 2004 입제 변량살포를 위한 제어시스템 개발. 서울대학교 석사 학위 논문
  2. 유지훈. 2005. 입제 비료의 변량살포를 위한 제어기 개발. 서울대학교 석사 학위 논문
  3. 이은오. 2000. 반복학습제어방법에 의한 DC 서보 모터 속도제어기의 PID 이득 자동조정 프로그램 기법. 단국대학교 석사 학위 논문
  4. Zhuang, S., Komatsu, M. 1996. Automatic Control of fertilizer Applicator and Seeder Based on Running Speed(Part 1 )-Development of Control Device and Feeding Performances of Seed and Fertilizer-日本 農業機械學會誌 58(1). pp.40-55