• 제목/요약/키워드: Speed of Current

검색결과 4,460건 처리시간 0.031초

영구자석 표면부착형 동기전동기의 전류제어기를 이용한 센서리스 기동방법 및 속도제어 (Sensorless Speed Control and Starting Algorithm using Current Control of SPM Synchronous Motor)

  • 백인철;이주석;김학원
    • 전력전자학회논문지
    • /
    • 제18권6호
    • /
    • pp.523-529
    • /
    • 2013
  • A sensorless speed control of a permanent magnet synchronous motor(PMSM) which utilizes MRAS based scheme to estimate rotor speed and position is presented. Considering an error between real and estimated rotor position values, a state equation of PMSM in the synchronous d-q reference frame is represented. A state equation of model system which uses estimated speed and nominal parameter values is expressed. To minimize the errors between the derivatives of d-q axis currents of real and model system, MRAS based adaptation mechanisms for the estimation of rotor speed and position are derived. On the other hand, for the acceleration stage of motor just before the sensorless operation, an acceleration scheme using only d-axis current control is proposed. To show the validity of the proposed scheme, experimental works are carried out and evaluated. During acceleration stage, the acceleration scheme using only d-axis current command shows good acceleration performance and controlled current level. For the sensorless operation, at low speed (5% of rated speed), a good performance is observed.

가변주파수에 있어서 유도잔동기특성의 도식산정법에 관한 연구 제3보 (A Study of the Current-Diagram Method for Calculating Induction Motor Characteristics with Adjustable Frequency)

  • 박민호
    • 전기의세계
    • /
    • 제18권5호
    • /
    • pp.20-25
    • /
    • 1969
  • The development of the frequency convertors using semiconductors devices makes it possible to control the speed of A.C. motors easily. It is now economically feasible to provide them with power at adjustable frequency using silicon-controlled rectifier (or thyristor) inverters. In such a case, in order to operate an induction motor efficiently over a wide speed range, it must be supplied from a variable frequency source of which frequency is adjustable over the speed range of the motor. It is desired to observe the changes in characteristics as primary current, torque-speed of induction motor etc. at any optional frequency. Although the characteristics can be obtained by means of the conventional methods, they require very complicated precedures of calculations. The Current Diagram Method in this paper suggests a new approach to simpler calculations of the characteristics, using the motor constants at reference frequency. The conclusions of this study are summarized as follows: 1) The equations of stator current at adjusted frequency were derived to construct graphical chart and the current circle required for the Current Diagram Method. 2) The radius, center of the current circle and the vector locus, the basis for calculating the characteristics, at any desired frequency could be easily determined with the aid of both the derived graphical chart and current circle at reference frequency. 3) The method was shown to be applicable to the various types of 3-phase induction motors and also dealt with its application to the split-phase, condenser motors.

  • PDF

초전도 한류기용 고속 고장전류 검출장치 (High-Speed Fault Current Detector for Superconducting Fault Current Limiter)

  • 이우영;박경엽;송기동;이병윤
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.300-302
    • /
    • 2002
  • In this paper the high-speed fault current detector for superconducting fault current limiter is described. Detecting and interrupting the fault currents as quickly as possible is required in order not to exceed the thermal capacity of superconducting fault current limiter. A detecting method of an instantaneous fault current magnitude is adopted in the equipment described in this paper and a current signal through an analog/digital(A/D) converter would be compared with the reference in the digital signal processor(DSP). Around 20ms has elapsed for detecting the fault current. It is necessary to establish the appropriate trade-off between the reliability and detection speed.

  • PDF

고속철도차량의 이선빈도가 귀선전류에 미치는 영향 (The Influence on Traction Return Current by Pantograph Detachment Frequency of High-speed Train)

  • 이성근;조영만;고광철
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.8-13
    • /
    • 2014
  • Currently it is major problem of electric railway with increasing drive speed such as the arc generated by the pantograph detachment and the distortion current in the motor-block high speed switching. When physical contact between the pantograph and the catenary line is separated, the pantograph detachment arcing occurs and it makes up the conductive noise to the return feeder. We made the EMTP modeling of the railway traction system and the pantograph arc by circuit elements and switches. The influence of pantograph detachment frequency is investigated by changing some frequencies. The over-current occurs in each detachment and it oscillates some time at beginning and stabilizes gradually. The magnitude of over-current is decided by instantaneous value of existing traction return current. If the detachment occurs at a point of peak value or distortion current, the over-current will be more harmful to the power systems connected with the return feeder and will become to arise with increasing detachment frequency.

전류정보를 이용한 가변속냉동시스템의 열교환기 실시간 고장 진단 (On-line Fault Detection and Diagnosis for Heat Exchanger of Variable Speed Refrigeration System Based on Current Information)

  • 이동규;정석권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.88-94
    • /
    • 2007
  • This study deals with on-line fault detection and diagnosis for heat exchanger of variable speed refrigeration system. Conventional studies about fault of heat exchanger in refrigeration system have used temperature and pressure information. The temperature and pressure are able to be used valuably for faults detection of constant speed refrigeration system. However in case of variable speed refrigeration system, the temperature and pressure are no longer useful information for fault detection due to compensation effect of feedback controller. While current information is possible to detect faults of variable speed refrigeration system. The current information was detected in an inverter, it was used after transforming rms value. The faults of variable speed refrigeration system are divided into electrical faults and mechanical faults. We performed fault detection and diagnosis about heat exchanger among mechanical faults such as condenser fouling and evaporator fan fouling through some experiments.

  • PDF

스위치드 릴럭턴스 전동기 구동을 위한 히스테리시스 전류 제어형 공진형 C-Dump 컨버터 (A Hysteresis Current Controlled Resonant C-Dump Converter for Switched Reluctance Motor)

  • 윤용호;김재문
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.72-78
    • /
    • 2008
  • The speed variation of SRM is fulfilled throughout a transition from chopping control to single pulse operation. (i,e., low speed to high speed operation). It is unsatisfied with performance at all operational regimes. In this paper, the operational performance of SRM can be improved by using current hysteresis control method. This method maintains a generally flat current waveform. At the high speed, the current chopping capability is lost due to the development of the back-EMF. Therefore SRM operates in single pulse mode. By using zero-current switching and zero-voltage switching technique, the stress of power switches can be reduce in chopping mode. When the commutation from one phase winding to another phase winding, the current can be zero as fast as possible in this period because several times negative voltage of DC-source voltage produce in phase winding. This paper is compared to performance based on conventional C-dump converter topology and the proposed resonant C-dump converter topology. Simulation and experimental results are presented to verify the effectiveness of the proposed circuit.

치과 핸드피스용 고속 PMSM의 정현파 구동을 위한 인버터 직류 링크전압 제어기법 (DC link voltage control method in the sinusoidal current drive system for dental hand-piece PMSM)

  • 전금상;박상욱;박재성;김상희;안희욱
    • 한국기계가공학회지
    • /
    • 제12권4호
    • /
    • pp.16-21
    • /
    • 2013
  • This paper presents a DC link voltage control method to reduce the ripple current and the switching loss in the sinusoidal current drive system for the wide-speed range PMSM. The DC link voltage of the three phase inverter in the sinusoidal current drive system is designed by the back-EMF voltage at maximum speed of the PMSM. In general, the drive systems have used the constant DC link voltage without reference to the motor speed. The current ripple causes hysteresis loss and makes noise. In addition, the switching loss on the inverter increases in proportion to the rise in the DC link voltage. In this paper, we propose the variable DC link voltage control method to reduce the current ripple in the PMSM drive system. We show reduction effect of the current repple and the switching loss through simulation results.

동해의 쓰시마난류 분포역에서 음속의 변동 (Variation of Sound Speed in the Tsushima Warm Current Region of the East Sea)

  • 이충일;조규대;김상우
    • 한국수산과학회지
    • /
    • 제36권2호
    • /
    • pp.170-177
    • /
    • 2003
  • This study is to analyze the influence of the Tsushima Warm Current (TWC) on the variation of sound speed in the southern part of the East Sea. Sound speed is calculated by method of Chen and Millero (1977:, based on the CTD data measured in June of 1996. Sound speed in the central part of the TWC is about $45ms^{-1}$ more fast than that in the other regions without the TWC. Sound speed minimum layer (SML) in the TWC region exists between loom and 341 m, while it exists between 260m and 290m in the non-TWC region. SML distributes along the path of TWC over continental shelf in the coastal waters of Japan.

고속 전류 구동 Analog-to-digital 변환기의 설계 (Design of A High-Speed Current-Mode Analog-to-Digital Converter)

  • 조열호;손한웅;백준현;민병무;김수원
    • 전자공학회논문지B
    • /
    • 제31B권7호
    • /
    • pp.42-48
    • /
    • 1994
  • In this paper, a low power and high speed flash Analog-to-Digital Converter using current-mode concept is proposed. Current-mode approach offers a number of advantages over conventional voltage-mode approach, such as lower power consumption small chip area improved accuracy etc. Rescently this concept was applied to algorithmic A/D Converter. But, its conversion speed is limited to medium speed. Consequently this converter is not applicable to the high speed signal processing system. This ADC is fabricated in 1.2um double metal CMOS standard process. This ADC's conversion time is measured to be 7MHz, and power consumption is 2.0mW, and differential nonlinearity is less than 1.14LSB and total harmonic distortion is -50dB. The active area of analog chip is about 350 x 550u$m^2$. The proposed ADC seems suitable for a single chip design of digital signal processing system required high conversion speed, high resolution small chip area and low power consumption.

  • PDF

Fault Diagnosis of Variable Speed Refrigeration System Based on Current Information

  • Lee, Dong-Gyu;Jeong, Seok-Kwon;Hua, Li
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권4호
    • /
    • pp.137-144
    • /
    • 2008
  • This study deals with on-line fault detection and diagnosis(FDD) for heat exchangers of a variable speed refrigeration system(VSRS) based on current information. The current residual which is the difference between real detected current from current sensors and estimated current from no fault model was utilized to diagnose faults of the heat exchangers. Comparing to the conventional FDD of constant refrigeration system based on temperature and pressure information, the suggested FDD method shows better robustness to the VSRS which has a feedback control loop. Moreover the suggested method can be expected more precise and faster diagnosis of faults about heat exchangers. Throughout some experiments, the validity of the method was verified.