• Title/Summary/Keyword: Speed change

Search Result 3,185, Processing Time 0.032 seconds

Optimal design of impeller in fan motor unit of cordless vacuum cleaner for improving flow performance and reducing aerodynamic noise (무선진공청소기 팬 모터 단품의 유량성능 향상과 공력소음 저감을 위한 임펠라 최적설계)

  • Kim, KunWoo;Ryu, Seo-Yoon;Cheong, Cheolung;Seo, Seongjin;Jang, Cheolmin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.5
    • /
    • pp.379-389
    • /
    • 2020
  • In this study, the flow and noise performances of high-speed fan motor unit for cordless vacuum cleaner is improved by optimizing the impeller which drives the suction air through flow passage of the cordless vacuum cleaner. Firstly, the unsteady incompressible Reynolds averaged Navier-Stokes (RANS) equations are solved to investigate the flow through the fan motor unit using the computational fluid dynamics techniques. Based on flow field results, the Ffowcs-Williams and Hawkings (FW-H) integral equation is used to predict flow noise radiated from the impeller. Predicted results are compared to the measured ones, which confirms the validity of the numerical method used. It is found that the strong vortex is formed around the mid-chord region of the main blades where the blade curvature change rapidly. Given that vortex acts as a loss for flow and a noise source for noise, impeller blade is redesigned to suppress the identified vortex. The response surface method using two factors is employed to determine the optimum inlet and outlet sweep angles for maximum flow rate and minimum noise. Further analysis of finally selected design confirms the improved flow and noise performance.

Development of Oxo-biodegradable Transparent Bio Films Using Biomass and Biodegradable Catalyst (바이오매스 및 생분해 촉매제를 이용한 산화생분해 투명 바이오 필름 개발)

  • You, Young-Sun;Kim, Young-Tae;Park, Dae-Sung;Choi, Sung-Wook
    • Clean Technology
    • /
    • v.23 no.2
    • /
    • pp.133-139
    • /
    • 2017
  • Bio-based plastics containing the biomass content higher than 25 wt% have been considered as environment-friendly materials due to their effects on the reduction in the $CO_2$ emission and petroleum consumption as well as biodegradability after use. In this study, poly vinyl chloride, plant-derived plasticizers, by adding a biodegradable catalyst was observed a change in the biodegradability and physical properties. To produce the oxidative decomposition transparent bio film, which is broken down in the initial percent elongation and physical properties such as tensile strength, it was to test the safety of the product as a food packaging material. Poly vinyl chloride, primary plasticizer, secondary plasticizer, anti fogging agent, the combined stabilizer were mixed in a high speed mixer, then extruded using an extrusion molding machine, after cooling, winding, to produce a oxidative decomposition transparent bio film and the control film, with a thickness of $12{\mu}m$ through winder role. Mechanical properties tensile strength, elongation, and the maximum load elongation and biodegradation test. Transparent bio film produced by biodegradation catalyst is compared with the control film. Tensile strength and elongation of films were found to be no significant difference. Further, as a result of the biodegradation test for 45 days based on the ASTM D6954-04 method, biodegrability of film is 61.4%.

An Investigation on the Magnetic Properties of Melt-Spun Fe-Pr-C Alloys (Melt-Spun Fe-Pr-C 합금의 자기적 특성 조사)

  • 장태석;조대형
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.4
    • /
    • pp.173-179
    • /
    • 1997
  • Change in phases, microstructures, and magnetic properties by the variation of quench rate and heat treatment were investigated for melt-spun $Fe_{77}Pr_{15}C_8$ ribbons. The amorphization of as-spun ribbons increased as the quench rate increased. As a result, the ribbon quenched at 40 m/s was almost entirely amorphous. Similarly to cast alloys, the primary phase in crystalline ribbons quenched at 10 m/s was $\alpha$-Fe followed by the secondary $Fe_{17}Pr_2C_x$. Crystalline phases were still dominant in the ribbon spun at 20 m/s, but in this case crystallization of $Fe_{17}Pr_2C_x$ was remarkable with a little suppression of $\alpha$-Fe. At 30 m/s an amorphous phase obviously dominated in the as-spun ribbons with small fraction of crystals. Therefore, substantial amount of hard magnetic $Fe_{14}Pr_2C$ was not obtained from the as-spun state but, as in cast alloys, produced only by a solid-state transformation. Within a few minutes fine grains of $Fe_{14}Pr_2C$ were easily obtained at relatively low temperature when the degree of amorphization of as-spun ribbons was higher. The grain size of $Fe_{14}Pr_2C$ was well less than 1${\mu}{\textrm}{m}$. The ribbons quenched at 20 or 30 m/s yielded higher coercivities after heat treatment.

  • PDF

Study on the Projectile Velocity Measurement Using Eddy Current Probe (와전류 탐촉자를 이용한 총구 탄속 측정에 관한 연구)

  • Shin, Jungoo;Son, Derac
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.3
    • /
    • pp.83-86
    • /
    • 2015
  • Nowadays the weapon systems are employed air bursting munition (ABM) as smart programmable 40 mm shells which have been developed in order to hit the target with programmed munition that can be air burst after a set distance in the battlefield. In order to improve the accuracy of such a bursting time, by measuring the speed of the munition from the barrel, weapon systems calculate the exact time of flight to the target and then the time information must be inputted to the munition. In this study, we introduce a device capable of detecting a shot at K4 40 mm automatic grenade. The shot is composed of a rotating copper band to convert linear motion into rotary motion when it passes through the barrel, the steel section is exert the effect of fragment and aluminum section to give fuze information. The aluminum section was used to detect munition using eddy current method. To measure muzzle velocity by means of non-contact method, two eddy current probes separated 10 cm was employed. Time interval between two eddy current probe detection times was used as muzzle velocity. The eddy current probe was fabricated U-shape Mn-Zn ferrite core with enamelled copper wire, and 200 kHz alternating current was used to detect inductance change. Measured muzzle velocity using the developed sensor was compared to the Doppler radar system. The difference was smaller than 1%.

Comparison on the Kinematic Variables of Racket Movement According to Velocity in Tennis Serve (테니스 서브 속도에 따른 라켓 움직임의 운동학적 변인 비교)

  • Lee, Dong-Jin;Oh, Cheong-Hwan;Jeong, Ik-Su;Park, Chan-Ho;Lee, Gun-Hee
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.2
    • /
    • pp.337-345
    • /
    • 2009
  • The purpose of this study were to find out the differences in kinematic variables of racket movement by performing the tennis serve. Three top male tennis players participated in this study. Three synchronized high-speed cameras were used to record the service action of top players for Three dimensional video analysis. The results of this study showed that (1) the velocity of the tennis racket at impact is important to the generation of racket velocity to Y-axis. This result indicates that forward motion and upward movement of the racket; (2) with respect to racket angular velocity at impact, the fast angular momentum of X-axis is important to generate the velocity of the tennis ball. This result indicate upward movement of the racket with a strong flexor of wrist joint; (3) the velocity of the tennis ball was influenced by the change of angular linking the Z-axis to -X-axis. This result indicates that the high velocity of the tennis ball is obtained from having the racket unitedly moving to the direction of the bill's flight at the acceleration interval and acquiring the distance of acceleration with the racket head vertically to the ground at the back scratching.

A Study on Fluid Flow Analysis of High Pressure Positive Displacement Pump without Clearance (클리어런스가 없는 초고압 회전용적형 헬리컬기어 펌프의 유동해석에 관한 연구)

  • Min, Se-Hong;Kim, Ho-Chul
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.33-38
    • /
    • 2015
  • For the purpose of high-pressure and suction of fixed amount, the development of ultra-high pressure rotating helical gear positive displacement pump with no clearance had been proceeded. The CFD analysis was performed to verify the internal pressure and the discharge flow velocity of the pump. Accordingly, a flow analysis were performed by FVM technique and we were unable to obtain a successful result since the fluid domain is separated because the grid is not configured in a row in FVM flow analysis of the fully enclosed type without clearance. Because of these problems, the flow analysis was performed by MPS method which grid configuration is not needed and the internal pressure and the discharge flow velocity of the pump were confirmed through the MPS flow analysis. At 1,000 rpm rotation speed of the rotor, the minimum internal pressure of the pump was 19.5 bar, maximum pressure was 44.6 bar and average pressure was 33.9 bar. And the minimum discharge flow velocity was 64.5 m/s, maximum discharge flow velocity was 84.8 m/s and average discharge flow velocity was 76.1 m/s. Through this study, we could confirm that MPS method was more suitable than FVM method in terms of flow analysis with no clearance. In addition, the relationship of the flow velocity according to the change of ultra-high pressure rotating helical gear positive displacement pump could be identified through this study.

The Effects of the Balance Training Program on the Excercise Performance and Injuries (정적균형훈련이 운동수행력 및 상해발생에 미치는 영향(탄성을 이용한))

  • Park, Sung-Hark
    • Journal of Korean Physical Therapy Science
    • /
    • v.11 no.3
    • /
    • pp.14-27
    • /
    • 2004
  • This study approaches the effects of Balance Training on excercise performance and the prevention from the injuries caused by excercise. The subjects of the Balance Training program are female exercise beginners and the research period covers 8 weeks from January 10 to March 7, 2003. The research objects are 19 female golf beginners in 30s to 40s, who live in Seoul or Seongnam in Gyeonggi province and have played golf less than 6 months. The programs of the Balance Training and exercise performance were conducted to an 11 experimental group among the 19 research objects at the same time, and only the exercise performance program was applied to an 8 control group for 8 weeks. Before and after 8 weeks' application of the research programs to each group, the research subjects were examined, especially the components of their bodies, the balance and the performance capability were measured both before and after the test. The frequency of injuries by exercise was measured after the test, and the difference of the frequency was compared with the frequency before exercise. First, the experimental group, in a measurement of balance, showed that SN, MB, SAr and SAg of static balance decreased in a situation of MEO, MEC, GEO, GEC, TBEO, TBO, FHEO, FEO(p <0.05), but the control group increased. Second, the analysis on the change of exercise performance indicated better improvement in distance, ball speed, and accuracy of the experimental group than the control group(p<0.05). Third, the experience of injuries showed that there were 2 injuries in the experimental group and 11 injuries in the control group. The injured parts were 2 cases in the hands and fingers of the experimental group, and 1 case in the shoulder, 4 in the elbows, 4 in the hands and fingers and 2 in the lumber of the control group. From the above-mentioned results, it is recognized that the Balance Training program improved the exercise performance of female golf beginners and had good effects on the prevention from injuries. Accordingly, if this program is applied to sports-beginners, it will contribute to the improvement of the public health.

  • PDF

Studies on the Effects $CCl_4$ on Exorine Pancreas (취외분비선에 미치는 사염화탄소의 영향)

  • Pae, Young-Sook
    • The Korean Journal of Pharmacology
    • /
    • v.11 no.1 s.17
    • /
    • pp.47-53
    • /
    • 1975
  • The metabolism of many drugs and also of steroid hormones is mediated by enzymes located in the microsomal fraction in smooth surfaced endoplasmic reticulum of mammalian liver. The duration and intensity of action of many drugs are largely determined by the speed at which they are metabolized in the body. Repeated administration of phenobarbital results in the induction of enzymes that metabolize a number of drugs. Lee et al. reported that daily administration of phenobarbital in rats significantly increased the activities of amylase in the pancreatobiliary juice, but the concentration of cholate in the bile was significantly lower in the treated group than that in the control group. After animals were treated with $CCl_4$, histological changes were shown in the endoplasmic reticulum, decreased microsomal enzyme activity and decreased hepatic protein synthesis were apparent. The purpose of the present report was to study the interaction between a 'microsomal-stimulating' agent such as phenobarbital and a 'microsomal- depressing' agent such as $CCl_4$ on hepatic and pancreatic functions in rats. The results obtained are summarized as follows: 1. The mortality rate of $CCl_4$ treated group was 34% and was decreased this figure to 15% with phenobarbital pretreatment. 2. In animals treated with phenobarbital the volume of biliary-pancreatic secretion was markedly elevated but the volume was decreased significantly in animals treated with $CCl_4$. 3. Total bilirubin output was elevated markedly in the $CCl_4$ treated group of rats pretreated with phenobarbital. The bilirubin concentration was increased in $CCl_4$ treated group and decreased in the group treated phenobarbital alone. 4. The concentration and total output of cholate in the bile were significantly lower in the all experimental group than control group. 5. In the animals treated with phenobarbital alone and phenobarbital plus $CCl_4$, the activity of lipase in pancreatobiliary juice was elevated, while in the animals treated with $CCl_4$ alone no change was observed. 6. The activity of amylase in the pancreatobiliary juice was decreased in the $CCl_4$ treated group, but elevated markedly in phenobarbital group and also elevated in phenobarbital-$CCl_4$ group. By the above results, it is concluded, when the liver was damaged by $CCl_4$, the exocrine function of pancreas and liver was decreased simultaneously. However, in the animals pretreated with phenobarbital, the toxicity of $CCl_4$ on the liver and pancreas was reduced.

  • PDF

Technology Level Evaluation Based On Technology Growth Model and Its Implication - In Case of 'Biochip and Biosensor Technology' (기술성장모형에 기반을 둔 기술수준평가 결과 및 시사점 - 바이오칩.센서기술을 중심으로)

  • Han, Min-Kyu;Kim, Byoung-Soo;Ryu, Ji-Yeon;Byeon, Soon-Cheon
    • Journal of Korea Technology Innovation Society
    • /
    • v.13 no.2
    • /
    • pp.252-281
    • /
    • 2010
  • In this paper, we analyze the result of the Technology Level Evaluation of 'Biochip and biosensor (BB) Technology' consisted of 3 sub-categorized technologies; biochip sensing (BS), lab on a chip and high-efficient customized health care technology. As an analysis tool, authors used a delphi (a repeated survey) and dynamic methodology with technology growth model to overcome limits of previous evaluations. As a result, levels of BB were evaluated 51.5% (Korea) and 75.1% (US), and the technology gap between two countries was 6.1 yrs. In 2013, these levels were expected to change to 60.1% (Korea), 78.4% (US) and 4.3 yrs, respectively. In comparison with other biotechnology, the gap of BB was smaller and expected to catch up with US faster. In the case of sub-categorized technologies, they showed the smallest gap and would have faster catch-up speed than other sub-categorized technologies in the Biotechnology field. Based on the result of the survey, relative superiority of BB in Korea was originated from competent researchers and research fund, but weak basic science would be weak points. We think that BB's characteristic as an emerging technology and concentrated research activities on BB are additional strong points. This research proposes the supporting and supplemented points to promote the BB in Korea.

  • PDF

Stand Growth Analysis and Carbon Storage/Removals Assesment using the Data of Forest Growth Monitoring Plots (고정조사구 자료를 이용한 임분생장 해석 및 탄소흡수${\cdot}$저장량 평가)

  • Kwon Soon Duk;Son Yeong Mo;Lee Kyeong Hak;Chong Se Kung;Kim Jung Myeong
    • Journal of Korea Foresty Energy
    • /
    • v.23 no.2
    • /
    • pp.1-8
    • /
    • 2004
  • This study looked into the change of tree growth of seven forest growth monitoring plots which were set up at the Undulyeong Hongchungun Kangwondo, and was accomplished to offer the basic data for the forest administration calculating carbon storage and removal in the Undulyeong area. Annual height and DBH growth were slowly progressed in the Pinus koraiensis and Larix kaempferi stand which was young stand, but the growth rate of the other stands was lower than those young stand. The diameter class of the mixed forest and Qurcus mongilica stand was predicted to be similar to the now and Pinus koraiensis and Larix kaempferi stand was predicted to move now diameter class to the high diameter class because thickening growth speed of the those stands were rapid. Now the end of 2003, total carbon storage of the Undulyeong model forest increased 149,000TC$(2.7\%)$ compared with the previous year. Seeing by forest types, occupied broad-leaved forest$(50\%)$, mixed forest$(34\%)$ and coniferous forest. During in 2003, total carbon which was removed and stored according to growth of the forest was 156,813TC and net carbon removal(148,664TC) increased into 2,613TC$(1.8\%)$ compared with the previous year. Seeing by forest types, occupied coniferous forest$(3.3\%)$, mixed forest$(3.1\%)$, broad-leaved forest$(2.8\%)$. Resultingly, the Undulyeong model forest is acting to net removal resource when see as green-gas side and net carbon removal are showing the tendency to increase recently little by little.

  • PDF