• 제목/요약/키워드: Spectrum Leakage

검색결과 101건 처리시간 0.026초

단일 주파수를 갖는 음향 인텐시티의 누설오차 개선 (Leakage Error Improvement of the Intensity with a single freqency)

  • 정의봉;안세진;정호경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1156-1161
    • /
    • 2001
  • Acoustic intensity is usually estimated by the cross-spectrum of acoustic pressure at two adjacent microphones. The cross-spectrum calculated by digital Fourier transform technique will unavoidally have leakage error since the period of signal will not be usually coincident with record length. Therefore, the acoustic intensity estimated by the conventional FFT analyzer will show distorted value. In this paper, the expression of the Fourier transformed date of a harmonic signal with a single frequency is formated when there is leakage error. The method to elimate the effect of leakage error from the contaminated data is also proposed. Some numerical examples show the validation of the proposed method.

  • PDF

가변 윈도우를 이용한 CELP 부호화기의 음질 향상에 관한 연구 (A Study on a Improvement of the Speech Quality with Variable Window in CELP Vocoder)

  • 주상규
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2010년도 춘계학술발표논문집 1부
    • /
    • pp.265-268
    • /
    • 2010
  • There have been proposed two types of low bit rate vocoder upto now : One is MBE type using the spectrum modeling and another is CELP type using the hybrid coding method. CELP type vocoder has mainly studied between them. Specially, much of intensity is concentrated in CELP vocoder due to the emergence of Internet Phone and PCS in a domestic. In order to improve the speech quality in CELP vocoder, in this paper, we proposed a new spectrum analysis algorithm with variable window. In CELP vocoder, the spectrum of the synthesised speech signal is distorted because the fixed size windows is used for spectrum analysis. So we have measured the spectral leakage and in order to minimize the spectral leakage have adjusted the window size. Applying this method G.723.1 ACELP, we can get SD(Spectral Distortion) reduction 0.084(dB), residual energy reduction 6.3% and MOS(Mean Opinion Score) improvement 0.1.

  • PDF

Optimization of the Emission Spectrum of Red Color in Quantum Dot-Organic Light Emitting Diodes

  • Jeong, Byoung-Seong
    • 공업화학
    • /
    • 제32권2호
    • /
    • pp.214-218
    • /
    • 2021
  • We investigated the optimal stacked structure from the perspective of process architecture (PA) through emission spectrum analysis according to the wavelength of quantum dot (QD)-organic light-emitting diodes (OLED). We confirmed that the blue-light leakage through the QD can be minimized by increasing the QD filling density above a critical value in the red QD (R-QD) layer. In addition, when the thickness of red-color filter (R-CF) at the upper part of the R-QD increased to more than 3 ㎛, the leakage of blue light through the R-CF was effectively blocked, and a very sharp emission spectrum in the red wavelength band could be obtained. According to these outstanding results, we expect that the development of QD-OLED displays with very excellent color gamut can be possibly realized.

인접 채널 누설이 에너지 검파 기반 스펙트럼 센싱에 미치는 영향 (Effects of Adjacent Channel Leakage on an Energy Detection Based Spectrum Sensing)

  • 임창헌;김형중;김창주
    • 한국전자파학회논문지
    • /
    • 제25권5호
    • /
    • pp.542-547
    • /
    • 2014
  • 1차 사용자(primary user)는 자신에게 할당된 대역을 사용하여 통신을 수행하는데, 이때 송신 신호의 전력은 대부분 해당 대역에 집중되어 있지만, 일부는 인접 대역으로 넘어간다. 이 때문에 인접 대역이 비어 있더라도 오경보율이 예상보다 크게 발생할 수가 있다. 이전 연구 중에 인접 대역 누설 현상이 스펙트럼 센싱에 미치는 영향을 분석한 것이 있지만, 이때 페이딩을 고려하지 않았다. 본 논문에서는 페이딩 채널 환경에서 인접 대역 누설이 에너지 기반 스펙트럼 센싱 성능에 미치는 영향을 검파 확률과 오경보 확률 측면에서 분석하고자 한다.

환경조건에 따른 EPDM 고분자 애자의 누설전류파형과 스펙트럼 분석 (Leakage Current Waveforms and Spectrum Analysis of EPDM Polymer Insulator according to Environment Condition)

  • 박재준;김정부;송영철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.82-86
    • /
    • 2004
  • This research is about the result of leakage current waveform about the situation of surface leakage current and environmental changes(Salt fog, clean fog and rain) by EPDM polymer insulators' amount of salt. The researcher presents the result of changing about fundamental harmonic, 3rd harmonic and 5th harmonic from starting point of supplying power to flashover. In this study, researched environmental affects (clean fog, salt fog and rain) about surface aging of polymer insulators and used frequency spectrum of leakage current waveform to develop the diagnostic technique of surface aging. When amount of salt contents changed, surface aging stage and the degree of aging (distortion factor) about 3rd and 5th harmonic waveform on low frequency harmonic wave. The distortion factor which is harmonic percentage about basic harmonic is important pointer to evaluate the surface condition of polymer insulators.

  • PDF

충격햄머 실험에서 다자유도 주파수 응답스팩트럼의 개선 (An Enhancement of Multi-Dof Frequency Response Spectrum From Impact Hammer Testing)

  • 안세진;정의봉
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.623-629
    • /
    • 2002
  • The spectrum of impulse response signal from an impulse hammer testing is widely used to obtain frequency response function(FRF) of the structure. However the FRFs obtained from impact hammer testing have not only leakage errors but also finite record length errors when the record length for the signal processing is not sufficiently long. The errors cannot be removed with the conventional signal analyzer which treats the signals as if they are always steady and periodic. Since the response signals generated by the impact hammer are transient and have damping, they are undoubtedly non-periodic. It is inevitable that the signals be acquired for limited recording time, which causes the finite record length error and the leakage error. In this paper, the errors in the frequency response function of multi degree of freedom system are formulated theoretically. And the method to remove these errors is also suggested. This method is based on the optimization technique. A numerical example of 3-dof model shows the validity of the proposed method.

  • PDF

최적화 기법을 이용한 다자유도 충격응답스펙트럼의 오차 개선 (The Improvement of Multi-dof Impulse Response Spectrum by Using Optimization Technique)

  • 안세진;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제12권10호
    • /
    • pp.792-798
    • /
    • 2002
  • The spectrum of impulse response signal from an impulse hammer testing is widely used to obtain frequency response function (FRF) of the structure. However the FRFs obtained from impact hammer testing have not only leakage errors but also finite record length errors when the record length for the signal processing is not sufficiently long. The errors cannot be removed with the conventional signal analyzer which treats the signals as if they are always steady and periodic. Since the response signals generated by the impact hammer are transient and have damping, they are undoubtedly non-periodic. It is inevitable that the signals be acquired for limited recording time, which causes the finite record length error and the leakage error. In this paper, the errors in the frequency response function of multi degree of freedom system are formulated theoretically. And the method to remove these errors is also suggested. This method is based on the optimization technique. A numerical example of 3-dof model shows the validity of the proposed method.

CELP 부호화기에서 가변 윈도우 스펙트럼 분석에 의한 성능 향상에 관한 연구 (A Study on an Improvement of the Performance by Spectrum Analysis with Variable Window in CELP Vocoder)

  • 민소연;김은환;배명진
    • 한국컴퓨터정보학회논문지
    • /
    • 제10권6호
    • /
    • pp.233-238
    • /
    • 2005
  • CELP 계열 음성부호화기는 대략 4.8kbps의 전송률로 음질 면에서 우수한 특성을 지닌다. 이중에서 인터넷폰과 화상회의를 위해 개발되어진 G.723.1 음성부호화기는 5.3kbps ACELP와 6.3kbps MP-MLQ 이중 전송률로 구성된다. 본 논문에서는 CELP 계열 음성부호화기의 음질 개선을 위해 가변 윈도우를 이용한 새로운 스펙트럼 분석 알고리즘을 제안한다. 기존의 방법에서는 스펙트럼 분석시 고정 윈도우를 사용하기 때문에 합성음의 스펙트럼의 경우 왜곡이 발생한다. 그러므로 스펙트럼 누설을 최소화하기 위해 조절되어진 윈도우를 사용하였다. 제안한 알고리즘을 G.723.1 ACELP에 적용한 실험결과에서 스펙트럼 왜곡은 0.084dB 정도 감소, 잔차 에너지는 6.3$\%$ 감소하였으며 이에 반해 MOS는 0.1 정도 개선되었다.

  • PDF

충격 햄머 실험에서 다자유도 주파수 응답 스펙트럼의 개선 (An Enhancement of Multi-Dof Frequency Response Spectrum from Impact Hammer Testing)

  • Ahn, Se-Jin;Jeong, Weui-Bong
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.363.2-363
    • /
    • 2002
  • The spectrum of impulse response signal from an impulse hammer testing is widely used to obtain frequency response function(FRF) of the structure. However the FRFs obtained from impact hammer testing have not only leakage errors but also finite record length errors when the record length for the signal processing is not sufficiently long. The errors cannot be removed with the conventional signal analyzer which treats the signals as if they are always steady and periodic. (omitted)

  • PDF

A Study on Electric Properties of Polyamide Film due to Temperature Change

  • Lee, Sung Ill
    • Elastomers and Composites
    • /
    • 제54권1호
    • /
    • pp.1-6
    • /
    • 2019
  • In this study, we measured the leakage current at $30{\sim}80^{\circ}C$ and $90{\sim}170^{\circ}C$ under a voltage of 200~980 V applied to samples (ordinary temperature) and polyamide film specimens degraded at $170^{\circ}C$ for 20 minute respectively. After the specimen was degraded at $130^{\circ}C$ and $50^{\circ}C$, a voltage of 200 to 800 V was applied for 10 to 60 minutes. The measurement of the leakage current resulted in the following conclusions. In the case of using Al and Cu as the main electrode, it was confirmed that the leakage current also increased in high temperatures as the voltage increased. Regardless of the type of main electrode, when the temperature was constant at $130^{\circ}C$ and $50^{\circ}C$, the leakage current increased as the voltage increased, and gradually decreased with time. As a result of the FTIR measurement, the main absorption of the infrared absorption spectrum was C=O at about $1650cm^{-1}$ and N-H diagonal vibration occurred at around $1550cm^{-1}$. There was no change in the material, so no effect of temperature was observed. By the results of SEM measurements, as the temperature of degradation increases, cracks in the specimen disappear. This may be because the amide bond (-CO-NH-) is absorbed by the material.