• Title/Summary/Keyword: Spectral Contrast

Search Result 164, Processing Time 0.023 seconds

Contrast-Enhanced Spectral Mammography Versus Ultrasonography: Diagnostic Performance in Symptomatic Patients with Dense Breasts

  • Zhongfei Lu;Cuijuan Hao;Yan Pan;Ning Mao;Xin Wang;Xundi Yin
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.442-449
    • /
    • 2020
  • Objective: To compare the diagnostic performance of contrast-enhanced spectral mammography (CESM) versus ultrasonography (US) in symptomatic patients with dense breasts, while using histology as the gold standard. Materials and Methods: After obtaining approval from the local ethics board, this prospective study collected data from patients with symptomatic breasts who underwent CESM and US examinations from May 1, 2017 to September 30, 2017. We then selected those with dense breasts and pathological results as our sample population. Both CESM and US results were classified by a radiologist through the Breast Imaging Reporting and Data System, and the results were compared with their corresponding histological results. The chi-square test was conducted to compare the diagnostic performance of CESM and US, and the receiver operating characteristic curves for the two imaging modalities were obtained. Results: A total of 131 lesions from 115 patients with dense breasts were included in this study. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were 93.8%, 88.1%, 88.2%, 93.7%, and 90.8% for CESM, and 90.6%, 82.1%, 82.9%, 90.2%, and 86.3% for US, respectively. The p values for sensitivity, specificity, PPV, NPV, and accuracy were 0.687, 0.388, 0.370, 0.702, and 0.238, respectively. The area under the curve of CESM (0.917) was comparable with that of US (0.884); however, the differences between CESM and US were not statistically significant (p = 0.225). Eight false-positive cases and 4 false-negative cases for breast cancer were found in CESM, while 12 false-positive cases and 6 false-negative cases were found in US. Conclusion: The diagnostic performances of CESM and US are comparable in symptomatic women with dense breasts; however, the routine use of additional US imaging is questionable for lesions that can be detected by CESM.

Digital Image Analysis(DIA) of Color Changes in Field Growing Stages for Rice (벼의 성장단계별 색 변화에 관한 디지털 화상해석)

  • Park, Jong-Hwa;Shin, Yong-Hee;Park, Min-Seo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.623-626
    • /
    • 2003
  • Image analysis was performed with two color systems, Red-Green-Blue (RGB) values and normalized Hue-Saturation-Intensity (HSI). We conducted field studies in Cheongju to determine canopy spectral reflectance and digital image analysis of rice. Spectral reflectance measurements made with a portable spectrometer(LI-1800) correlated with growing stage and digital images for rice. Images in which the color was specified by the common RGB coordinates could be used when there was a sharp contrast between the color of the rice and that of the field soil. In the absence of sharp contrast, identification of the rice covered area was much easer after the color had been transformed into HSI coordinates. This study introduced fundamental theories in digital image analysis and applied that for field situations rice.

  • PDF

Evaluation of color reproduction characteristics of CRT display system (CRT 디스플레이 시스템의 색재현성 평가)

  • 김홍석;박승옥;백정기
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.3
    • /
    • pp.259-264
    • /
    • 1999
  • The relationship is derived for color CRT display system between the spectral radian existence emitted and digital inputs. The amount of spectral radiant existence depends on the characteristics of the video board, electric circuits, and CRT as well as digital inputs. Especially, the function of this relationship changes as the amplifier gain and offset voltage of electric circuits. In this study, we set the test display system on the optimum state which satisfies gun independence characteristics by using the contrast and the brightness controls of display. Temporal stability, special uniformity, and color distinction of CRT display system are evaluated at the optimum state. Also contrasts in dark room and illuminated room are compared.

  • PDF

Adaptive Contrast Stretching for Land Observation in Cloudy Low Resolution Satellite Imagery

  • Lee, Hwa-Seon;Lee, Kyu-Sung
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.3
    • /
    • pp.287-296
    • /
    • 2012
  • Although low spatial resolution satellite images like MODIS and GOCI can be important to observe land surface, it is often difficult to visually interpret the imagery because of the low contrast by prevailing cloud covers. We proposed a simple and adaptive stretching algorithm to enhance image contrast over land areas in cloudy images. The proposed method is basically a linear algorithm that stretches only non-cloud pixels. The adaptive linear stretch method uses two values: the low limit (L) from image statistics and upper limit (U) from low boundary value of cloud pixels. The cloud pixel value was automatically determined by pre-developed empirical function for each spectral band. We used MODIS and GOCI images having various types of cloud distributions and coverage. The adaptive contrast stretching method was evaluated by both visual interpretation and statistical distribution of displayed brightness values.

Spectral Sensitization and Photographic Characteristics of 9-Phenyl-5,5'-Diphenyl-3,3'-Bis(3-sulfopropyl)Benzoxazolo Carbocyanine Triethyl Ammonium Set (9-Phenyl-5,5'-Diphenyl-3,3'-Bis(3-sulfopropyl)Benzoxazolo Carbocyanine Triethyl Ammonium Salt의 분광증감과 사진특성)

  • Kim, Yeoung-Chan
    • The Journal of Information Technology
    • /
    • v.8 no.3
    • /
    • pp.51-56
    • /
    • 2005
  • In this paper, we describe a study on the relationship between spectral sensitization and photographic characteristics of color paper. The photographic emulsion used in this study is a green-sensitizing emulsion. U.V maximum absorption peak value of 9-phenyl-5,5'-diphenyl-3,3'-bis(3-sulfopropyl)benzoxazolo carbocyanine triethyl ammonium salt was observed 507nm, and wedge spectrograms maximum peak value of color paper added dye to photographic emulsion was shown 553nm. As compared with the absorption peak of the dye in methanol solution, the sensitizing peaks of 9-phenyl-5,5'-diphenyl-3,3'-bis(3-sulfopropyl)benzoxazolo carbocyanine triethyl ammonium salt have red shifts of 46nm. The photographic characteristics of green-sensitizing emulsion were obtained contrast(2.6), speed(48-57), fog(0.08). Therefore, benzoxazolo carbocyanine dye is of industrial importance as green-sensitizing dye in the spectral sensitization of photographic emulsion.

  • PDF

Korean ESL Learners' Perception of English Segments: a Cochlear Implant Simulation Study (인공와우 시뮬레이션에서 나타난 건청인 영어학습자의 영어 말소리 지각)

  • Yim, Ae-Ri;Kim, Dahee;Rhee, Seok-Chae
    • Phonetics and Speech Sciences
    • /
    • v.6 no.3
    • /
    • pp.91-99
    • /
    • 2014
  • Although it is well documented that patients with cochlear implant experience hearing difficulties when processing their first language, very little is known whether or not and to what extent cochlear implant patients recognize segments in a second language. This preliminary study examines how Korean learners of English identify English segments in a normal hearing and cochlear implant simulation conditions. Participants heard English vowels and consonants in the following three conditions: normal hearing condition, 12-channel noise vocoding with 0mm spectral shift, and 12-channel noise vocoding with 3mm spectral shift. Results confirmed that nonnative listeners could also retrieve spectral information from vocoded speech signal, as they recognized vowel features fairly accurately despite the vocoding. In contrast, the intelligibility of manner and place features of consonants was significantly decreased by vocoding. In addition, we found that spectral shift affected listeners' vowel recognition, probably because information regarding F1 is diminished by spectral shifting. Results suggest that patients with cochlear implant and normal hearing second language learners would experience different patterns of listening errors when processing their second language(s).

Feature-Vector Normalization for SVM-based Music Genre Classification (SVM에 기반한 음악 장르 분류를 위한 특징벡터 정규화 방법)

  • Lim, Shin-Cheol;Jang, Sei-Jin;Lee, Seok-Pil;Kim, Moo-Young
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.5
    • /
    • pp.31-36
    • /
    • 2011
  • In this paper, Mel-Frequency Cepstral Coefficient (MFCC), Decorrelated Filter Bank (DFB), Octave-based Spectral Contrast (OSC), Zero-Crossing Rate (ZCR), and Spectral Contract/Roll-Off are combined as a set of multiple feature-vectors for the music genre classification system based on the Support Vector Machine (SVM) classifier. In the conventional system, feature vectors for the entire genre classes are normalized for the SVM model training and classification. However, in this paper, selected feature vectors that are compared based on the One-Against-One (OAO) SVM classifier are only used for normalization. Using OSC as a single feature-vector and the multiple feature-vectors, we obtain the genre classification rates of 60.8% and 77.4%, respectively, with the conventional normalization method. Using the proposed normalization method, we obtain the increased classification rates by 8.2% and 3.3% for OSC and the multiple feature-vectors, respectively.

A Study on the Improvement of Image Fusion Accuracy Using Smoothing Filter-based Replacement Method (SFR 기법을 이용한 영상 융합의 정확도 향상에 관한 연구)

  • Yun Kong-Hyun;Sohn Hong-Gyoo
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.04a
    • /
    • pp.187-192
    • /
    • 2006
  • Image fusion techniques are widely used to integrate a lower spatial resolution multispectral image with a higher spatial resolution panchromatic image. However, the existing techniques either cannot avoid distorting the image spectral properties or involve complicated and time-consuming decomposition and reconstruction processing in the case of wavelet transform-based fusion. In this study a simple spectral preserve fusion technique: the Smoothing Filter-based Replacement(SFR) is proposed based on a simplified solar radiation and land surface reflection model. By using a ratio between a higher resolution image and its low pass filtered (with a smoothing filter) image, spatial details can be injected to a co-registered lower resolution multispectral image minimizing its spectral properties and contrast. The technique can be applied to improve spatial resolution for either colour composites or individual bands. The fidelity to spectral property and the spatial quality of SFM are convincingly demonstrated by an image fusion experiment using IKONOS panchromatic and multispectral images. The visual evaluation and statistical analysis compared with other image fusion techniques confirmed that SFR is a better fusion technique for preserving spectral information.

  • PDF

Research for development of small format multi -spectral aerial photographing systems (PKNU 3) (소형 다중분광 항공촬영 시스템(PKNU 3호) 개발에 관한 연구)

  • 이은경;최철웅;서영찬;조남춘
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.11a
    • /
    • pp.143-152
    • /
    • 2004
  • Researchers seeking geological and environmental information, depend on remote sensing and aerial photographic datum from various commercial satellites and aircraft. However, adverse weather conditions as well as equipment expense limit the ability to collect data anywhere and anytime. To allow for better flexibility in geological and environmental data collection, we have developed a compact, multi-spectral automatic Aerial Photographic system (PKNU2). This system's Multi-spectral camera can record visible (RGB) and infrared (NIR) band (3032*2008 Pixels) images Visible and infrared band images were obtained from each camera respectively and produced color-infrared composite images to be analyzed for the purpose of the environmental monitoring. However this did not provide quality data. Furthermore, it has the disadvantage of having the stereoscopic overlap area being 60% unsatisfied due to the 12 seconds of storage time of each data The PKNU2 system in contrast, photographed photos of great capacity Thus, with such results, we have been proceeding to develop the advanced PKNU2 (PKNU3) system that consists of a color-infrared spectral camera that can photograph in the visible and near-infrared bands simultaneously using a single sensor, a thermal infrared camera, two 40G computers to store images, and an MPEG board that can compress and transfer data to the computer in real time as well as be able to be mounted onto a helicopter platform.

  • PDF