• 제목/요약/키워드: Spectral CT

검색결과 28건 처리시간 0.02초

Improvement of Analytic Reconstruction Algorithms Using a Sinogram Interpolation Method for Sparse-angular Sampling with a Photon-counting Detector

  • Kim, Dohyeon;Jo, Byungdu;Park, Su-Jin;Kim, Hyemi;Kim, Hee-Joung
    • 한국의학물리학회지:의학물리
    • /
    • 제27권3호
    • /
    • pp.105-110
    • /
    • 2016
  • Sparse angular sampling has been studied recently owing to its potential to decrease the radiation exposure from computed tomography (CT). In this study, we investigated the analytic reconstruction algorithm in sparse angular sampling using the sinogram interpolation method for improving image quality and computation speed. A prototype of the spectral CT system, which has a 64-pixel Cadmium Zinc Telluride (CZT)-based photon-counting detector, was used. The source-to-detector distance and the source-to-center of rotation distance were 1,200 and 1,015 mm, respectively. Two energy bins (23~33 keV and 34~44 keV) were set to obtain two reconstruction images. We used a PMMA phantom with height and radius of 50.0 mm and 17.5 mm, respectively. The phantom contained iodine, gadolinium, calcification, and lipid. The Feld-kamp-Davis-Kress (FDK) with the sinogram interpolation method and Maximum Likelihood Expectation Maximization (MLEM) algorithm were used to reconstruct the images. We evaluated the signal-to-noise ratio (SNR) of the materials. The SNRs of iodine, calcification, and liquid lipid were increased by 167.03%, 157.93%, and 41.77%, respectively, with the 23~33 keV energy bin using the sinogram interpolation method. The SNRs of iodine, calcification, and liquid state lipid were also increased by 107.01%, 13.58%, and 27.39%, respectively, with the 34~44 keV energy bin using the sinogram interpolation method. Although the FDK algorithm with the sinogram interpolation did not produce better results than the MLEM algorithm, it did result in comparable image quality to that of the MLEM algorithm. We believe that the sinogram interpolation method can be applied in various reconstruction studies using the analytic reconstruction algorithm. Therefore, the sinogram interpolation method can improve the image quality in sparse-angular sampling and be applied to CT applications.

New Unsymmetric Dinuclear Copper(II) Complexes of Trans-disubstituted Cyclam Derivatives: Spectral, Electrochemical, Magnetic, Catalytic, Antimicrobial, DNA Binding and Cleavage Studies

  • Prabu, R.;Vijayaraj, A.;Suresh, R.;Jagadish, L.;Kaviyarasan, V.;Narayanan, V.
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권5호
    • /
    • pp.1669-1678
    • /
    • 2011
  • Six new binuclear copper(II) complexes have been prepared by template condensation of the dialdehydes 1,8-[bis(3-formyl-2-hydroxy-5-methyl)benzyl]-l,4,8,11-tetraazacyclotetradecane (PC-a) and 1,8-[bis(3-formyl-2-hydroxy-5-bromo)benzyl]-l,4,8,11-tetraazacyclotetradecane (PC-b) with appropriate aliphatic diamines, and copper(II) perchlorate. The structural features of the complexes have been confirmed by elemental analysis, IR, UV-vis and mass spectra etc. The electrochemical behavior of all the copper(II) complexes show two irreversible one electron reduction process. The room temperature magnetic moment studies depict the presence of an antiferromagnetic interaction in the binuclear complexes. The catechol oxidation and hydrolysis of 4-nitrophenylphosphate were carried out by using the complexes as catalyst. The antimicrobial screening data show good results. The binding of the complexes to calf thymus DNA (CT DNA) has been investigated with absorption and emission spectroscopy. The complex [$Cu_2L^{1a}$] displays significant cleavage property of circular plasmid pBR322 DNA in to linear form. Spectral, electrochemical, magnetic and catalytic studies support the distortion of the copper ion geometry that arises as the macrocyclic ring size increases.

Unusual Fluorescence Spectroscopic Properties of 9-Anthrylethylene Derivatives : Photoisomerization

  • 최정권;Mahipal A. Reddy;윤민중
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권9호
    • /
    • pp.973-980
    • /
    • 1998
  • The fluorescence spectroscopic properties of both trans and cis forms of 9-anthryiethylene derivatives such as 9-AnthCH=$CHCO_2CH_3$ [Ⅰ] and 9-AnthCH=CHCN [Ⅱ] as well as 9-AnthCH=>TEX>$CHCH_2O_2CCH_3$ [Ⅲ] and 9-AnthCH=$CHCH_2OH$ [Ⅳ] have been measured in various solvents. In nonpolar solvent, the trans-I and trans-Ⅱ show dual emission spectral bands at 340 nm and 460 nm when exciting with 270 nm while the other trans derivatives show single emission band at 430 or 460 nm. The dual emissions exhibit different excitation spectra, indicating that two emissive states are different from each other. It is interesting to note that the 340 nm emission of both trans-Ⅰ and trans-Ⅱ is enhanced at the expense of the drastic quenching of the 460 nm emission as the solvent polarity increases. The dual emissions are also observed for both cis-Ⅰ and cis-Ⅱ. The solvent dependence of the fluorescence decay times and quantum yields can be correlated with the solvent and excitation wavelength dependences of the trans→cis photoisomerization quantum yields. These results indicate that the 340 nm emission is originated from the $S_2$ state of the cis-form, and the $S_1$ state is the only singlet excited state presenting a large CT (charge transfer) character to facilitate the photoisomerization.

토양에서 추출한 흄산의 분자량별 분류에 따른 분광학적 성질 비교 (Spectroscopic Characterization of Soil Humic Acid Fractions by Molecular Weight)

  • 신현상;문희정;양한범;윤석승
    • 대한화학회지
    • /
    • 제39권1호
    • /
    • pp.66-70
    • /
    • 1995
  • 토양에서 얻어진 흄산(HA)을 한외 여과법을 이용 분자량에 따라 4개의 소부분(F1 : 100,000 dalton 이상; F2 : 100,000 dalton 이하;10,000 dalton 이하; F4 : 2,000 dalton 이하)으로 분리한 뒤 적외선 분광법과 핵자기 공명 분광법을 통하여 각 소부분들의 분광학적 특성을 규명하고 상호간에 비교 분석하였다. 4개 소부분들의 $1^H$$13^C$ NMR 스펙트럼은 전체적인 특성에서 모두 흄산 모액 스펙트럼과 유사하게 나타났다. 이 결과는 분자량이 변하더라도 흄산의 전체적 특성이 그대로 유지됨을 제시한다. 차이점으로는 IR 스펙트럼 결과 분자량이 적어지면서 다당류 성분 함량이 다소 감소된 반면 카르복실기 성분 함량은 조금 증가된 것으로 나타났다.

  • PDF

Optical Properties of Oxotitanium (Ⅳ) Meso-tetrakis(4-sulfonatophenyl)porphyrin Intercalated into the Layered Double Hydroxides (LDH) Studied by Laser Spectroscopy

  • Ryu, Su-Young;Yoon, Min-Joong;Choy, Jin-Ho;Hwang, Sung-Ho;Frube, Akihiro;Asahi, Tsuyoshi;Hiroshi, Masuhara
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권4호
    • /
    • pp.446-452
    • /
    • 2003
  • Some new nanohybrid materials have been synthesized by intercalating the oxotitanium(IV) meso-tetrakis(4- sulfonatophenyl) porphyrin$(O=Ti^{(IV)} TSPP)$ into the Zn/Al layered double hydroxides (LDHs), and their structures and photophysical properties have been investigated by various laser spectroscopic techniques. According to the XRD pattern of the synthesized nanohybrid materials, the macrocycle plane of $O=Ti^{(IV)}$ TSPP are grafted perpendicular to the LDH layers. The $O=Ti^{(IV)}$ TSPP-intercalated LDH exhibits band broadening of the absorption spectrum and a blue shift of Q-band as compared to that observed in solution. Resonance Raman spectral measurements demonstrate that the positively charged LDHs give rise to a slight decrease of the electronic density of the porphyrin ring accompanying a small change of the electronic distribution of the $O=Ti^{(IV)}$ TSPP. Consequently the LDH environment affects the energies of the two highest occupied molecular orbitals (HOMOs) of the $O=Ti^{(IV)}$) TSPP, $a_{1u}$ and $a_{2u}$, producing a mixed orbital character. Being consistent with these electronic structural changes of $O=Ti^{(IV)}$ TSPP in LDH, both the fluorescence spectral change and the fsdiffuse reflectance transient measurements imply that the photoexcitation of the $O=Ti^{(IV)}$ TSPP intercalated into LDH undergoes fast relaxation to the O=Ti(IV) $TSPP^+-LDH^- $charge transfer (CT) state within a few picoseconds, followed by a photoinduced electron transfer between the O=Ti(IV) TSPP and LDHs with a rate constant greater than %1×10^{10}S^{-1}$. No evidence is found for back electron transfer. In conclusion, the $O=Ti^{(IV)}$ TSPP intercalated LDH seems to be a possible candidate for an artificial reaction center for an efficient solar energy conversion system.

Accurate Measurement of Agatston Score Using kVp-Independent Reconstruction Algorithm for Ultra-High-Pitch Sn150 kVp CT

  • Xi Hu;Xinwei Tao;Yueqiao Zhang;Zhongfeng Niu;Yong Zhang;Thomas Allmendinger;Yu Kuang;Bin Chen
    • Korean Journal of Radiology
    • /
    • 제22권11호
    • /
    • pp.1777-1785
    • /
    • 2021
  • Objective: To investigate the accuracy of the Agatston score obtained with the ultra-high-pitch (UHP) acquisition mode using tin-filter spectral shaping (Sn150 kVp) and a kVp-independent reconstruction algorithm to reduce the radiation dose. Materials and Methods: This prospective study included 114 patients (mean ± standard deviation, 60.3 ± 9.8 years; 74 male) who underwent a standard 120 kVp scan and an additional UHP Sn150 kVp scan for coronary artery calcification scoring (CACS). These two datasets were reconstructed using a standard reconstruction algorithm (120 kVp + Qr36d, protocol A; Sn150 kVp + Qr36d, protocol B). In addition, the Sn150 kVp dataset was reconstructed using a kVp-independent reconstruction algorithm (Sn150 kVp + Sa36d, protocol C). The Agatston scores for protocols A and B, as well as protocols A and C, were compared. The agreement between the scores was assessed using the intraclass correlation coefficient (ICC) and the Bland-Altman plot. The radiation doses for the 120 kVp and UHP Sn150 kVp acquisition modes were also compared. Results: No significant difference was observed in the Agatston score for protocols A (median, 63.05; interquartile range [IQR], 0-232.28) and C (median, 60.25; IQR, 0-195.20) (p = 0.060). The mean difference in the Agatston score for protocols A and C was relatively small (-7.82) and with the limits of agreement from -65.20 to 49.56 (ICC = 0.997). The Agatston score for protocol B (median, 34.85; IQR, 0-120.73) was significantly underestimated compared with that for protocol A (p < 0.001). The UHP Sn150 kVp mode facilitated an effective radiation dose reduction by approximately 30% (0.58 vs. 0.82 mSv, p < 0.001) from that associated with the standard 120 kVp mode. Conclusion: The Agatston scores for CACS with the UHP Sn150 kVp mode with a kVp-independent reconstruction algorithm and the standard 120 kVp demonstrated excellent agreement with a small mean difference and narrow agreement limits. The UHP Sn150 kVp mode allowed a significant reduction in the radiation dose.

폐경 전과 폐경 후 비만 여성의 심박변이도에 관한 연구 (Heart Rate Variability in Obese Climacteric Women in Korea;Relations between Autonomic Nervous System Activity and Obesity)

  • 황덕상;황미자;이윤재;이경섭;송미연
    • 한방비만학회지
    • /
    • 제8권1호
    • /
    • pp.81-88
    • /
    • 2008
  • Objectives To investigate the relationship between Heart Rate Variability and menopause among obese middle-aged women in Korea. Subjects and Methods Forty middle-aged women (age 49.05 $\pm$ 2.64 years) with BMI > $23kg/m^2$ were recruited by local advertisement. Blood profiles of estrogen, FSH, LH, glucose, total cholesterol, HDL-cholesterol, and triglyceride were measured. Autonomic Nervous System (ANS) was estimated by short-term spectral analysis of heart rate variability (HRV). Visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT) were accessed using Computerized Tomography (CT), Bioimpedance Analysis (BIA), and anthropometry. To scrutinize the influence of ANS on obesity-related factors, we divided the subjects into pre- and post-menopausal women. Results The total cholesterol, FSH and LH were significantly higher in post-menopausal obese women group. The estradiol and standard deviation of all normal R-R intervals (SDNN), high-frequency components (HF) of the HRV were significantly lower in postmenopausal obese women group (P<0.05). Adipose tissue distribution and blood profiles were not significantly different between two groups. Conclusion Menopause induced a decrease in SDNN and HF values and increase in total cholesterol level in obese women although the VAT itself was not related with ANS in obese women.

  • PDF

디지털 유방단층영상합성법의 FBP 알고리즘 적용을 위한 다양한 필터 조합에 대한 연구 (A Study of Various Filter Setups with FBP Reconstruction for Digital Breast Tomosynthesis)

  • 이행화;김예슬;이영진;최성훈;이승완;박혜숙;김희중;최재구;최영욱
    • 한국의학물리학회지:의학물리
    • /
    • 제25권4호
    • /
    • pp.271-280
    • /
    • 2014
  • 최근에 디지털 유방촬영술(digital mammography, DM)의 해부학적 구조의 겹침 현상과 컴퓨터단층촬영영상(computed tomography, CT)의 높은 환자 선량을 해결하기 위해 디지털 유방단층영상합성장치(digital breast tomosynthesis, DBT)에 대한 연구 개발이 활발하게 수행되고 있다. 하지만 DBT 시스템은 제한된 각도로 영상을 획득하면서 급격한 데이터 결핍으로 인해 다른 층의 간섭으로 인한 인공물(artifacts)이 발생한다. 이를 완화시키기 위해 적절한 필터가 필요하다. 본 논문에서는 DBT 시스템에서 FBP 알고리즘을 이용하여 영상재구성 시 발생되는 인공물을 줄이기 위해 적절한 필터조합을 찾는 것이 궁극적인 목적이다. 시뮬레이션과 실제 실험을 통해 동일한 영상 획득조건에서 FBP 알고리즘을 이용해 재구성된 영상을 분석하여 다양한 필터 조합들의 특성을 조사했다. 필터 특성에 대한 평가를 하기 위해 영상 및 프로파일의 분석과 COV (coefficient of variation)를 이용하여 인공물과 잡음에 대한 평가를 하였다. 본 연구 결과를 통해 분광필터(spectral filter)의 파라미터 인자 값들을 조절하여 cut-off frequency를 설정함으로써 고주파 영역에 있는 영상의 잡음을 줄일 수 있었다. DBT 시스템에서 유방팬텀을 재구성한 영상들을 비교했을 때 분광필터의 파라미터 인자를 0.25로 적용한 영상의 결과는 분광필터를 적용하지 않았을 때보다 영상의 잡음을 10%로 감소시킬 수 있었다. 절편두께필터(slice thickness filter)의 파라미터 인자의 값들을 조절하여 정보들의 불균형을 줄임으로써 다른 층의 간섭으로 인한 인공물을 감소시킬 수 있었다. 결론적으로, 본 연구를 통해 FBP 알고리즘으로 재구성했을 때 필터들의 기본 특성을 확인 할 수 있었으며, 적절한 필터 조합이 실제 화질 개선에 기여한 것으로 확인할 수 있었다. 이 연구 결과는 다양한 필터 조합에 따른 잡음과 데이터 결핍에 의한 인공물에 대한 정보를 제공하여 DBT 시스템의 개발 및 임상화적용 연구에 기반이 될 것으로 기대된다.