• 제목/요약/키워드: Speckle tracking

검색결과 18건 처리시간 0.017초

Subclinical left ventricular dysfunction in children after hematopoietic stem cell transplantation for severe aplastic anemia: a case control study using speckle tracking echocardiography

  • Kim, Beom Joon;Moon, Kyung Pil;Yoon, Ji-Hong;Lee, Eun-Jung;Lee, Jae Young;Kim, Seong Koo;Lee, Jae Wook;Chung, Nack Gyun;Cho, Bin;Kim, Hack Ki
    • Clinical and Experimental Pediatrics
    • /
    • 제59권4호
    • /
    • pp.190-195
    • /
    • 2016
  • Purpose: Severe aplastic anemia (SAA), a fatal disease, requires multiple transfusion, immunosuppressive therapy, and finally, hematopoietic stem cell transplantation (HSCT) as the definitive treatment. We hypothesized that iron overloading associated with multiple transfusions and HSCT-related complications may adversely affect cardiac function. Left ventricular (LV) function was assessed in children after HSCT for SAA. Methods: Forty-six consecutive patients with a median age of 9.8 years (range, 1.5-18 years), who received HSCT for SAA and who underwent comprehensive echocardiography before and after HSCT, were included in this study. The data of LV functional parameters obtained using conventional echocardiography, tissue Doppler imaging (TDI), and speckle-tracking echocardiography (STE) were collected from pre- and post-HSCT echocardiography. These data were compared to those of 40 age-matched normal controls. Results: In patients, the LV ejection fraction, shortening fraction, end-diastolic dimension, mitral early diastolic E velocity, TDI mitral septal E' velocity, and STE LV longitudinal systolic strain rate (SSR) decreased significantly after HSCT. Compared to normal controls, patients had significantly lower post-HSCT early diastolic E velocity and E/A ratio. On STE, patients had significantly decreased LV deformational parameters including LV longitudinal systolic strain (SS), SSR, and diastolic SR (DSR), and circumferential SS and DSR. Serum ferritin levels showed weak but significant correlations (P<0.05) with LV longitudinal SS and SSR and circumferential SS and DSR. Conclusion: Subclinical LV dysfunction is evident in patients after HSCT for SAA, and was associated with increased iron load. Serial monitoring of cardiac function is mandatory in this population.

Preliminary study on the effects of pergolide on left ventricular function in the horses with pituitary pars intermedia dysfunction

  • Gehlen, Heidrun;Fisch, Judith;Merle, Roswitha;Trachsel, Dagmar S.
    • Journal of Veterinary Science
    • /
    • 제22권5호
    • /
    • pp.64.1-64.12
    • /
    • 2021
  • Background: Pituitary pars intermedia dysfunction (PPID), a neurodegenerative disease leading to reduced dopamine production, is a common disease in aged horses. The treatment is based on administration of the dopamine agonist pergolide. This drug has been related to valvular fibrosis in humans, but the cardiovascular effect of this drug has not yet been investigated in horses. Objectives: To determine whether pergolide induces valvular disease in horses or affects the cardiac function. Methods: Standard, tissue Doppler (TDE) and two-dimensional speckle tracking (STE) echocardiography were performed in horses with diagnosed PPID based on adrenocorticotropic hormone dosage. Measurements taken in horses treated with pergolide were compared with those from untreated horses with nonparametric t-tests. Furthermore, measurements from follow-up examinations performed at least three months after the initial exam were compared with a Wilcoxon signed rank test for repeated measurements in each group. Results: Twenty-three horses were included. None of the 12 horses under treatment developed valvular regurgitation. Furthermore, no differences in the measurements of the left ventricular systolic or diastolic function could be seen between the group of horses with treatment and those without treatment. Measurements taken in the follow-up exam did not differ compared to those taken in the initial exam in both groups. Conclusions: No changes of the left ventricular function assessed by TDE and STE could be shown in a small population of horses with confirmed PPID. Treatment with pergolide did not affect the ventricular function nor induce valvular disease.

Global Left Ventricular Myocardial Work Efficiency in Patients With Severe Rheumatic Mitral Stenosis and Preserved Left Ventricular Ejection Fraction

  • Estu Rudiktyo;Amiliana M Soesanto;Maarten J Cramer;Emir Yonas;Arco J Teske;Bambang B Siswanto;Pieter A Doevendans
    • Journal of Cardiovascular Imaging
    • /
    • 제31권4호
    • /
    • pp.191-199
    • /
    • 2023
  • BACKGROUND: Assessment of left ventricular (LV) function plays a pivotal role in the management of patients with valvular heart disease, including those caused by rheumatic heart disease. Noninvasive LV pressure-strain loop analysis is emerging as a new echocardiographic method to evaluate global LV systolic function, integrating longitudinal strain by speckle-tracking analysis and noninvasively measured blood pressure to estimate myocardial work. The aim of this study was to characterize global LV myocardial work efficiency in patients with severe rheumatic mitral stenosis (MS) with preserved ejection fraction (EF). METHODS: We retrospectively included adult patients with severe rheumatic MS with preserved EF (> 50%) and sinus rhythm. Healthy individuals without structural heart disease were included as a control group. Global LV myocardial work efficiency was estimated with a proprietary algorithm from speckle-tracking strain analyses, as well as noninvasive blood pressure measurements. RESULTS: A total of 45 individuals with isolated severe rheumatic MS with sinus rhythm and 45 healthy individuals were included. In healthy individuals without structural heart disease, the mean global LV myocardial work efficiency was 96% (standard deviation [SD], 2), Compared with healthy individuals, median global LV myocardial work efficiency was significantly worse in MS patients (89%; SD, 4; p < 0.001) although the LVEF was similar. CONCLUSIONS: Individuals with isolated severe rheumatic MS and preserved EF, had global LV myocardial work efficiencies lower than normal controls.

DTTL 비트동기장치의 평균시간지연 편차 성능에 관한 연구 (Mean time delay variation performane of DTTL bit synchronizer)

  • 김관옥
    • 한국통신학회논문지
    • /
    • 제22권11호
    • /
    • pp.2401-2408
    • /
    • 1997
  • The measured pulse shapes provided in the given data package demonstrated pulse distortions due to laser speckle. the distorted pulse shapes were carefully analyzed, modeled, and then applied to the DTTL(Digital-data Transition Tracking Loop)[1] bit synchronizer simulator to measure the mean time delay and its delay variation performance. The result showed that the maximum mean time delay variation with the modeled data was 12.5% when window size equals 1. All the data given were located within this modeled boundary and the maximum eman time delay variation was 7% in this case. The mean time delay variation was known to be smaller by reducing the window size [2][5][6]. The mitigated delay variation was 2.5% in the modeled case and 1.4% in the data set given when the windown size equals 0.1. With the digital DTTL insteal of analog DTTL, similar results was obtained.

  • PDF

속도 벡터 영상 방법 (Velocity Vector Imaging)

  • 권성재
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권1E호
    • /
    • pp.11-27
    • /
    • 2010
  • Nowadays, ultrasound Doppler imaging is widely used in assessing cardiovascular functions in the human body. However, a major drawback of ultrasonic Doppler methods is that they can provide information on blood flow velocity along the ultrasound beam propagation direction only. Thus, the blood flow velocity is estimated differently depending on the angle between the ultrasound beam and the flow direction. In order to overcome this limitation, there have been many researches devoted to estimating both axial and lateral velocities. The purpose of this article is to survey various two-dimensional velocity estimation methods in the context of Doppler imaging. Some velocity vector estimation methods can also be applied to determine tissue motion as required in elastography. The discussion is mainly concerned with the case of estimating a two-dimensional in-plane velocity vector involving the axial and lateral directions.

Cardiac Phenotyping of SARS-CoV-2 in British Columbia: A Prospective Echo Study With Strain Imaging

  • Jeffrey Yim;Michael Y.C. Tsang;Anand Venkataraman;Shane Balthazaar;Ken Gin;John Jue;Parvathy Nair;Christina Luong;Darwin F. Yeung;Robb Moss;Sean A Virani;Jane McKay;Margot Williams;Eric C. Sayre;Purang Abolmaesumi;Teresa S.M. Tsang
    • Journal of Cardiovascular Imaging
    • /
    • 제31권3호
    • /
    • pp.125-132
    • /
    • 2023
  • BACKGROUND: There is limited data on the residual echocardiographic findings including strain analysis among post-coronavirus disease (COVID) patients. The aim of our study is to prospectively phenotype post-COVID patients. METHODS: All patients discharged following acute COVID infection were systematically followed in the post-COVID-19 Recovery Clinic at Vancouver General Hospital and St. Paul's Hospital. At 4-18 weeks post diagnosis, patients underwent comprehensive echocardiographic assessment. Left ventricular ejection fraction (LVEF) was assessed by 3D, 2D Biplane Simpson's, or visual estimate. LV global longitudinal strain (GLS) was measured using a vendor-independent 2D speckle-tracking software (TomTec). RESULTS: A total of 127 patients (53% female, mean age 58 years) were included in our analyses. At baseline, cardiac conditions were present in 58% of the patients (15% coronary artery disease, 4% heart failure, 44% hypertension, 10% atrial fibrillation) while the remainder were free of cardiac conditions. COVID-19 serious complications were present in 79% of the patients (76% pneumonia, 37% intensive care unit admission, 21% intubation, 1% myocarditis). Normal LVEF was seen in 96% of the cohort and 97% had normal right ventricular systolic function. A high proportion (53%) had abnormal LV GLS defined as < 18%. Average LV GLS of septal and inferior segments were lower compared to that of other segments. Among patients without pre-existing cardiac conditions, LVEF was abnormal in only 1.9%, but LV GLS was abnormal in 46% of the patients. CONCLUSIONS: Most post-COVID patients had normal LVEF at 4-18 weeks post diagnosis, but over half had abnormal LV GLS.

Trans-Aortic Flow Turbulence and Aortic Valve Inflammation: A Pilot Study Using Blood Speckle Imaging and 18F-Sodium Fluoride Positron Emission Tomography/Computed Tomography in Patients With Moderate Aortic Stenosis

  • Soyoon Park;Woo-Baek Chung;Joo Hyun O;Kwan Yong Lee;Mi-Hyang Jung;Hae-Ok Jung;Kiyuk Chang;Ho-Joong Youn
    • Journal of Cardiovascular Imaging
    • /
    • 제31권3호
    • /
    • pp.145-149
    • /
    • 2023
  • BACKGROUND: 18F-sodium fluoride positron emission tomography/computed tomography (18F-NaF PET/CT) has been proven to be useful in identification of microcalcifications, which are stimulated by inflammation. Blood speckle imaging (BSI) is a new imaging technology used for tracking the flow of blood cells using transesophageal echocardiography (TEE). We evaluated the relationship between turbulent flow identified by BSI and inflammatory activity of the aortic valve (AV) as indicated by the 18F-NaF uptake index in moderate aortic stenosis (AS) patients. METHODS: This study enrolled 18 moderate AS patients diagnosed within the past 6 months. BSI within the aortic root was acquired using long-axis view TEE. The duration of laminar flow and the turbulent flow area ratio were calculated by BSI to demonstrate the degree of turbulence. The maximum and mean standardized uptake values (SUVmax, SUVmean) and the total microcalcification burden (TMB) as measured by 18F-NaF PET/CT were used to demonstrate the degree of inflammatory activity in the AV region. RESULTS: The mean SUVmean, SUVmax, and TMB were 1.90 ± 0.79, 2.60 ± 0.98, and 4.20 ± 2.18 mL, respectively. The mean laminar flow period and the turbulent area ratio were 116.1 ± 61.5 msec and 0.48 ± 0.32. The correlation between SUVmax and turbulent flow area ratio showed the most positive and statistically significant correlation, with a Pearson's correlation coefficient (R2) of 0.658 and a p-value of 0.014. CONCLUSIONS: The high degree of trans-aortic turbulence measured by BSI was correlated with severe AV inflammation.

Changes in Cardiac Structure and Function After Kidney Transplantation: A New Perspective Based on Strain Imaging

  • Darae Kim;Minjeong Kim;Jae Berm Park;Juhan Lee;Kyu Ha Huh;Geu-Ru Hong;Jong-Won Ha;Jin-Oh Choi;Chi Young Shim
    • Journal of Cardiovascular Imaging
    • /
    • 제31권2호
    • /
    • pp.98-104
    • /
    • 2023
  • BACKGROUND: We aimed to investigate left ventricular (LV) global longitudinal strain (GLS) in end-stage renal disease patients and its change after kidney transplantation (KT). METHODS: We retrospectively reviewed patients who underwent KT between 2007 and 2018 at two tertiary centers. We analyzed 488 patients (median age, 53 years; 58% male) who had obtained echocardiography both before and within 3 years after KT. Conventional echocardiography and LV GLS assessed by two-dimensional speckle-tracking echocardiography were comprehensively analyzed. Patients were classified into three groups according to the absolute value of pre-KT LV GLS (|LV GLS|). We compared longitudinal changes of cardiac structure and function according to pre-KT |LV GLS|. RESULTS: Correlation between pre-KT LV EF and |LV GLS| were statistically significant, but the constant was not high (r = 0.292, p < 0.001). |LV GLS| was widely distributed at corresponding LV EF, especially when the LV EF was > 50%. Patients with severely impaired pre-KT |LV GLS| had significantly larger LV dimension, LV mass index, left atrial volume index, and E/e' and lower LV EF, compared to mildly and moderately reduced pre-KT |LV GLS|. After KT, the LV EF, LV mass index, and |LV GLS| were significantly improved in three groups. Patients with severely impaired pre-KT |LV GLS| showed the most prominent improvement of LV EF and |LV GLS| after KT, compared to other groups. CONCLUSIONS: Improvements in LV structure and function after KT were observed in patients throughout the full spectrum of pre-KT |LV GLS|.