• Title/Summary/Keyword: Specimens

Search Result 17,300, Processing Time 0.043 seconds

CLINICAL IMPLICATIONS OF TELOMERASE ACTIVITY IN ORAL SQUAMOUS CELL CARCIMOMA (구강편평세포암에서 telomerase 활성도의 임상적 연관성에 관한 연구)

  • Shim, Yu-Jin;Kim, Myung-Jin;Nahm, Dong-Seok;Lee, Jong-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.4
    • /
    • pp.289-300
    • /
    • 2001
  • Telomerase is a ribonucleoprotein that synthesizes telomere repeats. It has been reported that activation of telomerase was associtated with immortalization, proliferative activity and carcinogenesis. Recently, telomerase activity has been extensively studied in many kinds of malignant tumors for clinical diagnostic and/or prognostic utilities. In neuroblastoma, breast carcinoma, gastric carcinoma, non-small cell lung carcinoma, close relationship has been reported between high telomerase activity and lymph node metastasis, tumor aggressiveness and poor prognosis. The purpose of this study is to investigate the clinical implication of telomerase activity assay as an adjunctive factor in decision-making on neck node management, speedy pre-operative judging on histologic malignancy grading. Thus we performed semi-quantitative assay of telomerase activity using Telomerase PCR ELISA $kit^{(R)}$(Boeringer Manheim, Germany) and evaluated correlation between telomerase activity and tumor size, neck node metastasis, Anneroth malignancy score and influence of pre-operative chemotherapy on its activity in 27 cases of oral squamous cell carcinomas and 18 cases of normal oral epithelium. Also, correlation between telomerase activities and PCNA indices was evaluated. The results were obtained as follows: 1. The telomerase activities were detected in 24 specimens out of 27 oral squamous cell carcinoma specimens (88.9%) and in 5 specimens out of 18 normal oral epithelium specimens (27.8%). The mean value of telomerase activities was $0.9793{\pm}0.3428$ in 24 oral squamous cell carcinoma specimens and $0.4855{\pm}0.1117$ in 5 normal oral epithelium specimens. The positivity rate and mean value of telomerase activities in oral squamous cell carcinoma specimens were significantly higher than those of normal oral epithelium specimens (p<0.05). 2. There was no significant correlation between total Anneroth malignancy score and telomerase activity (p>0.05), but points of mitosis index and depth of invasion were significantly correlated with telomerase activities (p<0.05). 3. The positive immunohistochemical staining for PCNA(proliferating cell nuclear antigen) was observed in 26 specimens out of 27 oral squamous cell carcinoma specimens and mean value of PCNA indices of 26 specimens was $53.67{\pm}26.46$. PCNA indices were significantly correlated with telomerase activities (p<0.05). 4. The mean value of telomerase activities was significantly higher in pathologic T3/T4 group than in T1/T2 group (p<0.01). There was no significant difference of mean value of telomerase activities between pathologic neck node positive group and negative group (p> 0.05). Pre-operative chemotherapy significantly lowered the telomerase activities (p<0.05). The above results suggested telomerase activity could be used as diagnostic marker and adjunctive parameter for judging on histologic malignancy in oral squamous cell carcinoma.

  • PDF

Electrical Insulation Properties of Nanocomposites with SiO2 and MgO Filler

  • Jeong, In-Bum;Kim, Joung-Sik;Lee, Jong-Yong;Hong, Jin-Woong;Shin, Jong-Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.6
    • /
    • pp.261-265
    • /
    • 2010
  • In this paper, we attempt to improve the electrical characteristics of epoxy resin at high temperature (above $80^{\circ}C$) by adding magnesium oxide (MgO), which has high thermal conductivity. Scanning electron microscopy (SEM) of the dispersion of specimens with added MgO reveals that they are evenly dispersed without concentration. The dielectric breakdown characteristics of $SiO_2$ and MgO nanocomposites are tested by measurements at different temperatures to investigate the filler's effect on the dielectric breakdown characteristics. The dielectric breakdown strength of specimens with added $SiO_2$ decreases slowly below $80^{\circ}C$ (low temperature) but decreases rapidly above $80^{\circ}C$ (high temperature). However, the gradient of the dielectric breakdown strength of specimens with added MgO is slow at both low and high temperatures. The dielectric breakdown strength of specimens with 0.4 wt% $SiO_2$ is the best among the specimens with added $SiO_2$, and that of specimens with 3.0 wt% and 5.0 wt% MgO is the best among those with added MgO. Moreover, the dielectric strength of specimens with 3.0 wt% MgO at high temperatures is approximately 53.3% higher than that of specimens with added $SiO_2$ at $100^{\circ}C$, and that of specimens with 5.0 wt% of MgO is approximately 59.34% higher under the same conditions. The dielectric strength of MgO is believed to be superior to that of $SiO_2$ owing to enhanced thermal radiation because the thermal conductivity rate of MgO (approximately 42 $W/m{\cdot}K$) is approximately 32 times higher than that of $SiO_2$ (approximately 1.3 $W/m{\cdot}K$). We also confirmed that the allowable breakdown strength of specimens with added MgO at $100^{\circ}C$ is within the error range when the breakdown probability of all specimens is 40%. A breakdown probability of up to 40% represents a stable dielectric strength in machinery and apparatus design.

Effects of Microcapsules on Mechanical Properties and Thermal Stability of Microcapsule Embedded Polymeric Resins (마이크로캡슐이 폴리머 수지의 기계적 특성 및 열안정성에 미치는 영향)

  • Yoon, Sung Ho;Kim, Min Sik;Jang, Se Yong
    • Composites Research
    • /
    • v.28 no.5
    • /
    • pp.316-321
    • /
    • 2015
  • This study investigated the effects of microcapsules on mechanical properties and thermal stability of the composite material containing self-healing microcapsules. To this end, tensile specimens and flexural specimens containing melamine-urea-formaldehyde (M-U-F) shell walled microcapsules with diameters of $70{\sim}130{\mu}m$ were manufactured. Varying amount of microcapsules in the specimens was considered: 0 wt%, 0.5 wt%, and 1.0 wt%. The tensile and flexural tests were conducted to evaluate mechanical properties of the specimens containing the microcapsules and the thermogravimetric analysis test was performed to evaluate the thermal stability of the specimens containing the microcapsules. The results show that the tensile strength of the specimens was sensitive to the amount of the microcapsules compared to the tensile modulus even though the tensile modulus of the specimens was not significantly affected by the amount of the microcapsules. However, reduction of the tensile strength was not linearly proportional to the amount of microcapsules; similar results were observed in the flexural test. The weight changes of the specimens containing the microcapsules, as a function of temperature, were similar to those specimens without microcapsules. The thermal stability of the specimens was not affected significantly by the microcapsules embedded in the specimens.

EFFECT OF COLLAGEN DISSOLUTION IN ACID CONDITIONED DENTIN LAYER ON RESIN-DENTIN ADHESION (산 표면처리된 상아질 표층의 교원섬유 용해가 레진-상아질간 결합에 미치는 영향)

  • Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.856-868
    • /
    • 1995
  • The effect of collagen dissolution in acid conditioned dentin layer on resin - dentin adhesion was investigated. 160 freshly extracted human molars were divided into 4 groups randomly and dentin surfaces were exposed. 40 exposed dentin surfaces were not acid conditioned and each 10 of them were applied with bonding agents within dentin bonding systems of All Bond 2, Scotchbond Multipurpose, Clearfil Photobond and Superbond D - Liner respectively. Each 10 of another 40 exposed dentin surfaces were acid conditioned by the acid within the above four bonding systems respectively and applied with corresponding bonding systems. After acid conditioning of the other 40 exposed dentin surfaces as above, they were treated with 5% NaOCl for 2 minutes, and each 10 of them were applied with the above four dentin bonding systems respectively. The remaining 40 dentin surfaces were acid conditioned and treated with 10% NaOCl for 2 minutes, and each 10 of them were applied with corresponding bonding agents as the above. After the procedures were finished, composite resin (Z -100, 3M Dent. Prod., USA) were applied on the dentin surfaces and light cured. Shear bond strength values were measured. Surface changes of fractured dentin specimens were observed using SEM (Hitachi S-2350, Japan). The following results were obtained. 1. In all of dentin bonding systems, shear bond strengths of non - conditioned specimens were significantly lower than those of acid conditioned specimens (P<0.05). 2. A statistically significant difference of bond strengths did not exist between acid conditioned specimens and 5% NaGCI retreated specimens applied with All Bond 2, Scotchbond Multipurpose and Clearfil Photobond (P>0.05). However, strength values of 5% NaOCl retreated specimens applied with Superbond D - Liner were lower than those of acid conditioned specimens (P<0.05). 3. In all the applied dentin bonding systems except Clearfil Photobond, bond strengths of 10% NaOCl retreated specimens were lower than those of acid conditioned and 5% NaOCl retreated specimens (P<0.05). 4. The resin - dentin hybrid layer of 4 - $5{\mu}m$ thickness was formed in the acid conditioned specimens applied with All Bond 2, Scotchbond Multipurpose and Superbond D-Liner. 5. The resin - dentin hybrid layer of 3 - $4{\mu}m$ thickness was still formed in the 5% NaOCl retreated specimens applied with All Bond 2 and Scotchbond Multipurpose. In addition, this layer was not completely removed after the retreatment with 10% NaOCl. Above results indicate that the dissolution of collagen in acid conditioned dentin layer by NaOCl solution can not be achieved completely and the collagens contribute to the resin - dentin adhesion considerably.

  • PDF

Distribution and Classification of Cordyceps Parasites in Cicada (매미를 기주로 한 동충하초의 분포와 분류 동정)

  • Oh, Junsang;Han, Sang-Kuk;Shrestha, Bhushan;Sung, Gi-Ho;Sung, Jae-Mo
    • Journal of Naturopathy
    • /
    • v.8 no.2
    • /
    • pp.78-87
    • /
    • 2019
  • Purpose: The aim was to collect and classify the Cordyceps parasitized in cicadas from July to October every year from 1990 to 2016 in Korea. And they were frequently collected in Nepal, Vietnam, Japan, China, and Thailand. Methods: Cordyceps parasitizing cicadas collected in mountains and fields. Results: A total of 1,104 specimens were collected that belonged to 10 different species under nine genera. The highest number of samples belonged to Ophiocordyceps (563 specimens), followed by Isaria (361 specimens), Polycephalomyces (73 specimens), Cordyceps (70 specimens), Beauveria (25 specimens), Perennicordyceps (8 specimens), Metarhizium (2 specimens) and Purpureocillium (2 ones). Among Ophiocordyceps spp. O. longissima was most frequently collected with a total of 426 samples out of 563, followed by O. heteropoda with 120 ones and O. sobolifera with 17 specimens. The species mainly collected in Korea, but C. ishikariensis was collected in Nepal only. The new characteristic was that Isaria cicada-like synnemata were found growing together with C. ishikariensis stromata on the same host. In Korea, the collected 691 specimens in total out of 1,104 were found in Mt. Halla in Jeju Island. Other mountains in Korea where the samples were collected were Mountains Daeryong, Jiri, Yongmoon, Samag, Seolag, Gujeol, Duryun, Baegam, Chilgap, Chundeung, Naejang, Welchul, and Daeryong. The three samples were not identified. Conclusions: A total of 1,104 specimens belonged to 10 different species under nine genera, and the collected 691 samples were found in Mt. Halla in Jeju Island.

Evaluation of the repair capacities and color stabilities of a resin nanoceramic and hybrid CAD/CAM blocks

  • Bahadir, Hasibe Sevilay;Bayraktar, Yusuf
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.140-149
    • /
    • 2020
  • PURPOSE. This study evaluated the color stabilities of two computer-aided design and computer-aided manufacturing (CAD/CAM) blocks and a nanofill composite resin and the microtensile bond strength (µTBS) between the materials. MATERIALS AND METHODS. Twelve specimens of 4 mm height were prepared for both Lava Ultimate (L) and Vita Enamic (E) CAD/CAM blocks. Half of the specimens were thermocycled (10,000 cycle, 5° to 55℃) for each material. Both thermocycled and non-thermocycled specimens were surface treated with one of the three different methods (Er,Cr:YSGG laser, bur, or control). For each surface treatment group, one of the thermocycled and one of non-thermocycled specimens were restored using silane (Ceramic Primer II), universal adhesive (Single Bond Universal), and nanofill composite resin of 4-mm height (Filtek Ultimate). The other specimens were restored with the same procedure without using silane. For each group, 1 × 1 × 8 mm bar specimens were prepared using a microcutting device. Bar specimens were thermocycled (10,000 cycle, 5° to 55℃) and microtensile tests were performed. Staining of the materials in coffee solution was also compared using a spectrophotometer. Data were analyzed using one-way ANOVA, t-test and post-hoc Scheffe tests. RESULTS. µTBS were found similar between the thermocycled and non-thermocycled groups (P>.05). The highest µTBS (20.818 MPa) was found in the non-thermocycled, bur-ground, silane-applied E group. Silane increased µTBS at some E groups (P<.05). Composite resin specimens showed more staining than CAD/CAM blocks (P<.05). CONCLUSION. CAD/CAM blocks can be repaired with composite resins after proper surface treatments. Using silane is recommended in repair process. Color differences may be shown between CAD/CAM blocks and the nanofill composite after a certain time period.

FLEXURE STRENGTH AND COLOR CHANGE OF REUSED IPS EMPRESS 2 (반복 사용된 IPS Empress 2의 굽힘강도와 색변화에 관한 연구)

  • Song Young-Kuk;Kim Yu-Lee;Kim Sung-Hoon;Ahn Hee-Young;Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.1
    • /
    • pp.71-80
    • /
    • 2003
  • Development of new ceramic and esthetic need of patient increased the use of ceramic restorations. The purpose of this study was to confirm the possibility of recycling for IPS Empress2 which has a lot of advantages in esthetics. 1st, 2nd and 3rd pressed disc-shaped($10{\times}1.5mm$) IPS Empress 2 specimens were made with IPS Empress ingot(shade 200, Ivoclar, Liechtenstein) and pressing furnace(IPS Empress EP 500, Ivoclar, Liechtenstein). Flexure strength was measured with universal testing machine(Zwick 145641, Zwick, Germany), and color change and staining resistance of specimens were evaluated with colorimeter (Model TC-6FX, Tokyo Denshoku Co., Japan). The followings were drawn from this study : 1. Flexure strength of the 1st, the 2nd, and the 3rd pressed specimens showed 236.78 MPa. 247.16MPa, and 220.72MPa, respectively. Flexure strength of the 2nd pressed specimens was higher than others, but there's no statistical difference between them. 2. The color difference between the 1st and the 2nd pressed specimens was 3.25, and that between the 1st and the 3rd pressed specimens was 3.63(P<0.05). 3. The color change after staining of the 1st, the 2nd. and the 3rd pressed specimens were 1.43, 2.64, and 1.45, respectively. In this study, reused IPS Empress 2 specimens showed insignificant change of flexure strength and stain resistance, but they showed some color change according to reuse. From this results, the limited possibility of reuse for IPS Empress 2 could be considered.

Evaluation of Fatigue Behavior for Laser Welded High Strength Steel Sheets (SPFC590) (고장력 강판(SPFC590)의 레이저 용접부 피로거동 평가)

  • Heo, Cheol;Kwon, Jong-Wan;Cho, Hyun-Deog;Choi, Sung-Jong;Chung, Woo-Young
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.5
    • /
    • pp.53-64
    • /
    • 2012
  • Deep and narrow welds can be produced by laser welding at high welding speeds with a narrow heat-affected zone (HAZ) and little distortion of the workpiece. This study aims to evaluate the usefulness of laser welding at automobile component manufacture. Microstructure observation, hardness test, tensile test and fatigue life test are performed by using the fiber laser welded SPFC590 steel sheets which is used widely in the manufacture of automotive seat frame. Three kinds of specimens are only a SPFC590 steel plate, quasi-butt joint plate and lap joint plate by laser welding. The following results that will be helpful to understand the static strength, fatigue crack initiation and growth mechanism were obtained. (1) The tensile strength of quasi butt joint specimens nearly equal to base metal specimens, but lap joint specimens fractured in shear area of weld metal. (2) The fatigue strength of quasi-butt joint specimen was approximately 8 percent lower than that of the base metal specimens. Furthermore, the lap joint specimens were less than 86 percent of the base metal specimens. (3) The lap joint fatigue specimens fractured at shear area in high level stress amplitude, while fractured at normal area in low level stress amplitude. From these results, the applicability of the laser welding to the automobile component is discussed.

Fatigue Crack Growth Behavior of a Magnesium-Based Composite (마그네슘 금속복합재의 피로균열거동해석)

  • Kim, Doo Hwan;Park, Yong Gul;Kim, Sung Hoon;Han, Suk Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.4 s.33
    • /
    • pp.515-521
    • /
    • 1997
  • The effects of heat treatment and fiber orientation on tensile strength and fatigue behavior were studied in a continuously reinforced. magnesium-based composite Following an earlier TEM investigation, specimens were thermally aged to modified the interfacial zone between the alumina fibers and the magnesium alloy matrix. From the tensile experimental results, the ultimate tensile strength of the aged specimens were lower than that of the as-fabricated due to weak fiber-matrix interfacial strength with chemical reaction during the thermal processing. The fatigue crack growth experiments were conducted with specimens having the fiber orientation normal to the crack growth direction (longitudinal) and also specimens with the fibers oriented parallel to the crack growth direction(transverse). A comparison of the fatigue crack growth behavior indicates that aged longitudinal specimens are more resistant to fatigue crack growth the as-fabricated longitudinal specimens. Conversely, as-fabricated transverse specimens are more resistant to fatigue crack growth than aged transverse specimens.

  • PDF

SHEAR BOND STRENGTH OF COMPOSITE RESIN CORE USED IN COMBINATION WITH VARIOUS RESIN CEMENTS AND DENTIN BONDING AGENTS (레진 시멘트와 상아질접착제를 사용한 콤포지트 레진 코아의 전단결합강도에 관한 연구)

  • Kim Hyun-O;Vang Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.30-40
    • /
    • 2004
  • Purpose : The purpose of this study was aimed to compare the shear bond strength on dentin of three dentin bonding agents and two resin cements used in conjunction with self-cured composite resin core material. Material and method : Control group and six experimental groups were divided for this study. Control group was designated as specimens bonded with Tenure$ A&B^{(R)}$. Experimental groups were as follows : PB-BL group : specimens bonded with Prime&Bond $NT^{(R)}$, $BondLink^{(R)}$ SB-BL group : specimens bonded with $^{(R)}$, BondLink$SingleBond^{(R)}$ PB group : specimens bonded with Prime&Bond $NT^{(R)}$ SB group : specimens bonded with $SingleBond^{(R)}$ PF group : specimens bonded with $Panavia-F^{(R)}$ BI group specimens bonded with Bistite $II^{(R)}$ All specimens were stored in $37^{\circ}C$ distilled water for 24 hours, followed by the shear bond strength was tested by universal testing machine. The data was analysed statistically by Mann-Whitney test. Results : 1. For Prime&Bond $NT^{(R)}$ and $SingleBonde^{(R)}$, the shear bond strength was 0.24 MPa and 7.19 MPa each by each, while Tenure $A&B^{(R)}$ group control was measured at 13.93 MPa (p<0.05). Especially for Prime&Bond $NT^{(R)}$ it did not get conjunction with dentin. 2. For Prime&Bond $NT^{(R)}$ and $SingleBond^{(R)}$ using $BondLink^{(R)}$, there was no significant difference as a result of 11.73 MPa and 14.00 MPa each by each (p<0.05). 3. For $Panavia-F^{(R)}$ and Bistite $II^{(R)}$, they showed the highest shear bond strength as measured by 18.24 MPa and 16.09 MPa each (p<0.05).