• 제목/요약/키워드: Specimen thickness

Search Result 1,052, Processing Time 0.027 seconds

Interpretation of Stress Crack Resistance of Damaged Geomembranes (손상된 지오멤브레인의 응력균열 저항성 해석)

  • Jeon, Han-Yong;Kahn, Belas Ahmed;Jang, Yeon-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.305-313
    • /
    • 2010
  • HDPE smooth and textured GMs were cut into dumbbell shape and notched where depth of the notch produced a ligament thickness of 90% to 10% of the nominal thickness of the specimen at 10% interval. Yield stress and elongation were measured of those samples and plotted on Graph. Yield stress and elongation at yield point decreases gradually as the notch depth is increased. Both installations damaged and notched GMs were used to understand stress crack behavior. Intact sample were notched in such a manner that the depth of notch produced a ligament thickness of 80% of the nominal thickness of the specimen. Installation damaged samples were not notched. Stress Crack Resistance behavior was observed using NCTL Test at $50{\pm}1^{\circ}C$ at different yield stresses immerging with pH 4 and pH 12 buffer solutions. Significant difference was observed in both cases.

  • PDF

A Study on the Fatigue Crack Propagation Behavior by the Variation of Heat Treatment Temperature and Thickness in Mild Steel (연강의 열처리 온도와 두께 변화에 따른 피로균열성장거동에 관한 연구)

  • 오환교
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.3
    • /
    • pp.40-44
    • /
    • 2000
  • The fatigue and tensile test were carried out with Mild steel using the Dump Frame of commercial car. The specimens were heat-treated at $810^{\circ}C$ and $930^{\circ}C$ and worked 4.5, 6.0, 8.0mm thickness in order to look over the mechanical properties and fatigue life by heat treatment and thickness from the tensile test result, the yield strength of the heat treated specimens was increased about 35% more than that of the non-heat treated specimen. The fatigue life of non-heated specimen was decreased 15% but that of heat treated specimens at $870^{\circ}C$ and $930^{\circ}C$ were decreased 16.38% and 13.16% respectably according to increasing the thickness from 4.5 to 8.0mm.

  • PDF

Shear bond strength of zirconia to resin: The effects of specimen preparation and loading procedure

  • Chen, Bingzhuo;Yang, Lu;Lu, Zhicen;Meng, Hongliang;Wu, Xinyi;Chen, Chen;Xie, Haifeng
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.313-323
    • /
    • 2019
  • PURPOSE. Shear bond strength (SBS) test is the most commonly used method for evaluating resin bond strength of zirconia, but SBS results vary among different studies even when evaluating the same bonding strategy. The purpose of this study was to promote standardization of the SBS test in evaluating zirconia ceramic bonding and to investigate factors that may affect the SBS value of a zirconia/resin cement/composite resin bonding specimen. MATERIALS AND METHODS. The zirconia/resin cement/composite resin bonding specimens were used to simulate loading with a shear force by the three-dimensional finite element (3D FE) modeling, in which stress distribution under uniform/non-uniform load, and different resin cement thickness and different elastic modulus of resin composite were analyzed. In vitro SBS test was also performed to validate the results of 3D FE analysis. RESULTS. The loading flat width was an important affecting factor. 3D FE analysis also showed that differences in resin cement layer thickness and resin composite would lead to the variations of stress accumulation area. The SBS test result showed that the load for preparing a SBS specimen is negatively correlated with the resin cement thickness and positively correlated with SBS values. CONCLUSION. When preparing a SBS specimen for evaluating bond performance, the load flat width, the load applied during cementation, and the different composite resins used affect the SBS results and therefore should be standardized.

A study on the transmittance due to thickness of zirconium core (지르코니아 코어의 두께에 따른 분광광도계 투과율에 관한 연구)

  • Jung, In-Ho;Park, Myung-Ja;Kim, Joo-Won
    • Journal of Technologic Dentistry
    • /
    • v.33 no.2
    • /
    • pp.129-136
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the transmittance differences of zirconium core due to thickness within the visible light spectrum. Methods: 36 specimens were divided into 3 groups (0.6mm, 0.8mm, 1.0mm) which have each 12 specimens. The size of specimens was 10mm high and 10mm wide. The transmittance of specimens are measured by spectrophotometer Model Cary 500 that can measure infrared-ray, visible wave and ultraviolet-ray. Results: The results shows that there was no significant difference between specimen's thickness and transmittance. Conclusion: The individual's color perception is personal and there are numerous factors that influence on it. In general, human eye can perceive the color of thing only within visible light spectrum but in this experiment through spectrophotometer there was no big difference between specimen's thickness and transmittance. To sum up, The most important factors were a layed porcelain structure and its thickness rather than core thickness in the porcelain crown.

Design of a specimen holder for living cell in the soft X-ray microscopy (연 X-선 현미경을 위한 생체시료 고정장치 설계)

  • 권영만;김경우;윤권하
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.705-708
    • /
    • 2003
  • To observe a hydrated biological specimen, an environmental chamber was necessary to keep the specimen in a wet state under vacuum surroundings. The specimen holder is as follows designed consequently. The specimen holder consisted of two Si wafers, the centers of which were Si$_3$N$_4$(100nm thickness) windows of a 0.3mm square. The windows were made by a photo-lithographic method. The transmission of a window at 400eV is about 70%. A hydrated biological specimen was put between the two windows. When the chamber was closed, two wafers were contact at the metal mesh by the pressure of O-rings, and the specimen holder moved by the three micrometers.

  • PDF

Evaluation of Optimized Ring Specimen Shape for the Hoop Behavior Test of Nuclear Fuel Clad Tube (핵연료 피복관의 후우프 거동시험을 위한 시편의 최적형상 평가)

  • 서기석
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2000.04a
    • /
    • pp.171-178
    • /
    • 2000
  • In order to evaluate the tensile behaviors of hoop direction for the nuclear fuel cladding tubes the shapes of specimen and jig fixtures for the ring test are decided with various conditions under the elastic-large plastic deformations. The axial displacement of the jig cylinders is converted to the circumferential direction elongations of specimen. The stress distributions on specimen are depended on the radii and locations of specimen and jig size and central angle. Therefore we calculated the stress distributions and decided the optimum shapes to get the uniform stress in the area of specimen gage length. Form the analysis the stress distributions in gate area are reviewed with the radii and location of specimen notch and the central angle of jig cylinder,. The optimum shapes of specimen and jig are proposed to the clad tube having 10.62 mm in diameter and 0.63mm in thickness for 16x16 PWR nuclear fuel assembly.

  • PDF

Fracture Behaviour Analysis of the Crack at the Specimen with the Type of Mode I Composed of the Bonded Carbon Fiber Reinforced Plastic (접합된 CFRP로 구성된 Mode I형 시험편 크랙의 파괴 거동 해석)

  • Lee, Jung-Ho;Cho, Jae-Ung;Cheon, Seong-Sik;Kook, Jeong Han
    • Composites Research
    • /
    • v.28 no.6
    • /
    • pp.356-360
    • /
    • 2015
  • In this paper, the carbon fiber reinforced plastic is processed as the double cantilever beam in order to estimate the fracture behavior of composite and is carried out with the static analysis as the mode I. The specimen sizes are 25 mm, 30 mm, 35 mm and 40 mm. And the material property is used with carbon. As the analysis result of mode I, the adhesive part is detached latest by the small force at the specimen thickness of 25 mm. The largest force is happened at the specimen thickness of 40 mm. The defection of the adhesive interface is shown slowest at the displacement of 9.75 mm at the specimen thickness of 25 mm. And the defection is shown quickest at the displacement of 7.82 mm at the specimen thickness of 40 mm. This defection is due to the fracture of specimen. The result of this study on the defection of the adhesive interface and the reaction force due to this defection is thought to be contributed to the safe structural design of the carbon fiber reinforced plastic.

Hysteretic behaviour of circular tubular T-joints with local chord reinforcement

  • Shao, Y.B.;Wang, Y.M.;Yang, D.P.
    • Steel and Composite Structures
    • /
    • v.21 no.5
    • /
    • pp.1017-1029
    • /
    • 2016
  • When a welded circular hollow section (CHS) tubular joint is subjected to brace axial loading, failure position is located usually at the weld toe on the chord surface due to the weak flexural stiffness of the thin-walled chord. The failure mode is local yielding or buckling in most cases for a tubular joint subjected to axial load at the brace end. Especially when a cyclic axial load is applied, fracture failure at the weld toe may occur because both high stress concentration and welding residual stress along the brace/chord intersection cause the material in this region to become brittle. To improve the ductility as well as to increase the static strength, a tubular joint can be reinforced by increasing the chord thickness locally near the brace/chord intersection. Both experimental investigation and finite element analysis have been carried out to study the hysteretic behaviour of the reinforced tubular joint. In the experimental study, the hysteretic performance of two full-scale circular tubular T-joints subjected to cyclic load in the axial direction of the brace was investigated. The two specimens include a reinforced specimen by increasing the wall thickness of the chord locally at the brace/chord intersection and a corresponding un-reinforced specimen. The hysteretic loops are obtained from the measured load-displacement curves. Based on the hysteretic curves, it is found that the reinforced specimen is more ductile than the un-reinforced one because no fracture failure is observed after experiencing similar loading cycles. The area enclosed by the hysteretic curves of the reinforced specimen is much bigger, which shows that more energy can be dissipated by the reinforced specimen to indicate the advantage of the reinforcing method in resisting seismic action. Additionally, finite element analysis is carried out to study the effect of the thickness and the length of the reinforced chord segment on the hysteretic behaviour of CHS tubular T-joints. The optimized reinforcing method is recommended for design purposes.

A STUDY ON THE CURING EFFECT OF COMPOSITE RESIN BY VISIBLE LIGHT THROUGH TOOTH SUBSTANCE (가시광선(可視光線)의 치질투과(齒質透過) 후(後) 복합(複合)레진 경도(硬度)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Bang, Sang-Hoon;Park, Sang-Jin;Min, Byung-Soon;Choi, Ho-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.1
    • /
    • pp.85-93
    • /
    • 1986
  • The purpose of this study was to investigate the curing effect of visible light through tooth substance, 0.5mm, 1.0mm thickness of enamel and dentin were prepared. Experimental specimen were made by Bisfil M & Silux packing into cylindrical brass mold 6.0mm in diameter, 2.0mm and 3.0mm, in height. All specimen were irradiated by visible light (Grip type) model No. SDL-50 Shofu Co.) for 30 seconds through tooth substance. Experimental groups were classified into enamel group (group 1) and dentin group (group 2) according to the thickness of tooth materials and then were divided into 2 subgroups (0.5mm group and 1.0mm group). In experimental groups, visible light irradiated to the specimen through either 0.5mm in thick or 1.0mm in think of tooth material. In Control group specimen were prepared by direct irradiation on the specimen surface of visible light without through tooth substance. The hardness was measured with a Barcol hardness tester (Barber-Colman Co. U.S.A.) for each prepared specimen. The results were as follows: 1. In control group, there were higher hardness values than those of in experimental group. 2. In experimental groups, 0.5mm groups had higher hardness values than 1.0mm groups did. 3. The hardness value at top surface of the specimen were higher than the hardness of bottom surface in each group. 4. Bisfil M had higher hardness values than Silux. 5. In all specimen of 3.0mm height polymerization effect was not occurred at bottom surface except Bisfil M in control group.

  • PDF

Numerical investigation of The characteristics of Biaxial Flexure Specimens (수치해석을 이용한 이방향 휨인장 시험체의 특성분석)

  • Kim, Ji-Hwan;Zi, Goang-Seup;Kang, Jin-Gu;Oh, Hong-Seob
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.614-617
    • /
    • 2008
  • This paper presents the numerical investigation of the characteristics of biaxial flexure specimens for the Biaxial Flexure Test(BFT) which was recently developed to measure the biaxial tensile strength of concrete. Using FEM, the effect of size and eccentricity on the specimens was evaluated. The parameters such as radious of the support and the loadings, thickness and free length were studied. The results of the FE analysis were entirely consistent with the predictive solution, when b/agt;0.4, h/alt;0.6 and the thickness of the specimens were increased. On the other hands, when b/agt;0.4, those with lesser free length showed good results. To limit the difference between the stresses at the end points of 2b as the specimen was sustained and the stress at the center point of the specimen are not over 10%, lateral eccentricity was analyzed to be in the limits of 3%.

  • PDF