• Title/Summary/Keyword: Specimen thickness

Search Result 1,052, Processing Time 0.029 seconds

New test method for real-time measurement of SCC initiation of thin disk specimen in high-temperature primary water environment

  • Geon Woo Jeon;Sung Woo Kim;Dong Jin Kim;Chang Yeol Jeong
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4481-4490
    • /
    • 2022
  • In this study, a new rupture disk corrosion test (RDCT) method was developed for real-time detection of stress corrosion cracking (SCC) initiation of Alloy 600 in a primary water environment of pressurized water reactors. In the RDCT method, one side of a disk specimen was exposed to a simulated primary water at high temperature and pressure while the other side was maintained at ambient pressure, inducing a dome-shaped deformation and tensile stress on the specimen. When SCC occurs in the primary water environment, it leads to the specimen rupture or water leakage through the specimen, which can be detected in real-time using a pressure gauge. The tensile stress applied to the disk specimen was calculated using a finite element analysis. The tensile stress was calculated to increase as the specimen thickness decreased. The SCC initiation time of the specimen was evaluated by the RDCT method, from which result it was found that the crack initiation time decreased with the decrease of specimen thickness owing to the increase of applied stress. After the SCC initiation test, many cracks were observed on the specimen surface in an intergranular fracture mode, which is a typical characteristic of SCC in the primary water environment.

S45C 강의 피로균열전파 지연거동의 영향인자에 관한 실험적 연구 (An Experimental Study on the Factors that Affect Fatigue Crack Growth Retardation Behavior in S45C Steel)

  • 김선진;안석환
    • 대한기계학회논문집A
    • /
    • 제25권3호
    • /
    • pp.470-477
    • /
    • 2001
  • Constant ΔK fatigue crack growth tests were performed by applying an intermediate multiple overload for S45C steel. The purpose of the present study is to investigate effects of specimen thickness at various baseline stress intensity factor range levels (ΔK(sub)b), overload application position (a/W) and overload application frequency (OL(sub)HZ) on fatigue crack growth retardation behavior. The principal results are summarized as follows. The amount of retardation for a given ΔK(sub)b level is increased with increasing the baseline stress intensity factor range level for all specimen thickness. The normalized minimum crack growth rate is increased with increasing the specimen thickness, except for ΔK=45MPa√m. The retardation cycle is decreased with increasing a/W and increased with OL(sub)HZ.

Dimensional Responses of Wood Under Cyclical Changing Temperature at Constant Relative Humidity

  • Yang, Tiantian;Ma, Erni;Shi, Yi
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권5호
    • /
    • pp.539-547
    • /
    • 2015
  • To investigate dimensional responses of wood under dynamic temperature condition, poplar (populous euramericana Cv.) specimens, 20 mm in radial (R) and tangential (T) directions with two thicknesses of 4 and 10 mm along the grain, were exposed to cyclic temperature changes in square wave between $25^{\circ}C$ and $40^{\circ}C$ at 60% relative humidity (RH) for three different cycling periods of 6 h, 12 h and 24 h. R and T dimensional changes measured during the cycling gave the following results: 1) Transverse dimensional changes of the specimens were generally square but at an opposite phase and lagged behind the imposed temperature changes. The phase lag was inversely correlated with cycling period, but positively related to specimen thickness, while the response amplitude was directly proportional to cycling period, but in a negative correlation with specimen thickness. 2) The specimens showed swelling hysteresis behavior. The heat shrinkage coefficient (HSC) became greater as cycling period increased or specimen thickness decreased. 3) Dimensional changes of the specimens produced deformation accumulation during repeated adsorption and desorption. The deformation accumulating ratio decreased with an increase in cycling period and specimen thickness. 4) Wood suffered 1.5 times as many dimensional changes per unit temperature variation as per unit humidity variation, and this deformation behaved even more seriously under static condition.

SM45C 강의 피로균열전파 지연거동에 미치는 영향인자에 관한 실험적 연구 (An Experimental Study on the Factors that Affect Fatigue Crack Growth Retardation Behavior in SM45C Steel)

  • 김선진;김종훈;안석환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.55-60
    • /
    • 2000
  • Constant ${\Delta}K$ fatigue crack growth tests were performed applying an intermediate multiple overload for SM45C steel. The purpose of the present study is to investigate the effects of specimen thickness at various baseline stress intensity levels$({\Delta}K_b)$, overload application frequency(a/W) and overload application frequency$(OL_{HZ})$ on fatigue crack growth retardation behavior. The principal results are summarized as follows. The amount of retardation for a given ${\Delta}K_b$ level is increased with increasing the baseline stress intensity level in all specimen thickness. The normalized minimum crack growth rate is increased with increasing the specimen thickness, except for ${\Delta}K=45MPa \sqrt m$. The retardation cycle is decreased with increasing the overload application position and increased with the overload application frequency.

  • PDF

경량화용 박육부재의 형상비가 압궤특성에 미치는 영향 (Influence of dimensional ratio on collapse characteristics for the thin-walled structures of light weight)

  • 정종안;김정호;양인영
    • 한국안전학회지
    • /
    • 제13권3호
    • /
    • pp.11-23
    • /
    • 1998
  • In this study, collapse test of thin-walled structure is performed under axially quasi-static and impact load in collapse characteristic to develop the optimum structural member for a light-oriented automobile. Furthermore, the energy-absorbing capacity is observed according to the variety of configuration(circular, square), aspect ratio in aluminum specimen to obtain basic data for the improved member of vehicle. In both quasi-static and impact collapse test, Al circular specimens collapse, in general, with axisymmetric mode in case of thin thickness while collapse with non-axisynmetric mode according to the thickness increase. For Al rectangular specimens, they collapse with axisymmetric mode in case of thin thickness, with mixed collapse mode according to the increase of thickness. In terms of initial max. load, Al square specimen turns out the best member among specimens, and then Al square, circular and circular with large scaling ratio, respectively. In case of quasi-static compression test, the absorbed energy per unit volume and mass shows higher in Al circular specimen, and then Al square, circular with large scaling ratio, respectively, according to shape ratio the absorbed energy per unit volume and mass in case of max. impact compression load is higher than that of static load. But the absorbed energy per unit volume and mass shows that Al circular specimen is the best member. Especially, unlike max. compression loan, the absorbed energy per unit volume and mass in impact test turns out the low value.

  • PDF

판두께에 따른 압흔가공에 의한 피로크랙 전파거동 (The Effect of Thickness of Plate on Fatigue Crack Propagation Behavior by Indentations)

  • 송삼홍;최진호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.826-830
    • /
    • 1994
  • Making Brinell indentations facing each other near the crack tip is very effective method in increasing fatigue life. In this paper, fatigue test was performed after indentation to investigate the effect of thickness of specimen. The results show that fatigue lives increased my making indentation and retardation cycle is inverse proportional to thickness of specimen.

  • PDF

Effect of Lateral Diffusion on Hydrogen Permeation Measurement in Thick Steel Specimens

  • Traidia, A.;El-Sherik, A.M.;Attar, H.;Enezi, A.
    • Corrosion Science and Technology
    • /
    • 제16권4호
    • /
    • pp.201-208
    • /
    • 2017
  • A finite element analysis is proposed to study the effect of specimen dimensions on lateral diffusion of hydrogen during hydrogen permeation flux measurements. The error of measurement on thick specimens because of 1D diffusion approximation may be as much as 70%. A critical condition for accurate measurements is to designate the area of hydrogen monitoring/exit surface smaller than the area of hydrogen charging/entry surface. For thin to medium thickness specimens (ratio of thickness to specimen radius of 5:10 and below), the charging surface should be maximized and the monitoring surface should be minimized. In case of relatively thick specimens (ratio of thickness to specimen radius above of 5:10), use of a hydrogen-diffusion barrier on the specimen boundaries is recommended. It would completely eliminate lateral losses of hydrogen, but cannot eliminate the deviation towards 2D diffusion near the side edges. In such a case, the charging surface should be maximized and the monitoring surface should be as closer in dimension as the charging surface. A regression analysis was carried out and an analytical relationship between the maximum measurement error and the specimen dimensions is proposed.

파괴인성치 Jic 결정에 대한 시험편 두께의 영향에 관한 연구 (The Thickness Effect on the Determination of Fracture Toughness Jic)

  • 고성위
    • 수산해양기술연구
    • /
    • 제24권2호
    • /
    • pp.83-93
    • /
    • 1988
  • 본 연구에서는 J 적분을 이용하여 두께의 변화에 따른 파괴인성치의 거동을 검토하기 위하여 두께 25mm의 일반구조용 압연강판을 평면가공하여 두께 5, 10, 15, 20, 25mm의 CT 시험편을 제작하였다. 이때 크랙비는 z=0.60인 상태에서 두께를 변화시켜가면서 파괴인성수 J 하(C)와 열단계수 T의 거동을 고찰하였다. 얻어진 결과를 요약하면 다음과 같다. 1) 평면응력 파괴인성치 J 하(C)는 각각의 두께에 대하여 Merkle식에 의한 결과가 가장 높게 나타나고 Rice식, Simpson식, Yoon식의 순서로 나타난다. 2) 평면응력 파괴인성치 J 하(C)는 동일한 J 적분식을 적용하였을 때 두께가 감소함에 따라 증가하였다가 두께 15mm를 기준으로 다시 감소한다. 3) Yoon식을 사용할 경우 평면응력 파괴인성치 J 하(C)와 시험편 두께 B의 상관관계를 무차원화시켜 다음과 같은 실험식을 얻었다. J 하(C)/J 하(IC)=1.7-15.1(B/W)+112.9(B/W) 상(2) -301.3(B/W) 상(3) +260.6(B/W) 상(4) R=0.999 4) 열단계수 T는 각각의 두께에 대하여 Merkle식에 의한 결과가 가장 높게 나타나며, Rice식, Simpson식, Yoon식에 의한 결과의 순으로 나타난다. 5) 열단계수 T는 각각의 단면의 두께에 대하여 동일한 J 적분식을 적용하였을 때 두께의 변화에 따라 거의 일정한 값을 나타내며, 이에 많은 대한 연구 검토가 요망된다

  • PDF

한국형 발사체 적용 대형 박판 배관 시편 제작 및 성능 평가 (Manufacturing and Performance Evaluation on Specimen pipes with Large Size Diameter and Thin Thickness for KSLV-II)

  • 이한주;이정호;오승협
    • 항공우주기술
    • /
    • 제12권1호
    • /
    • pp.81-86
    • /
    • 2013
  • 본 연구에서는 다양한 발사체 추진기관 공급계 배관 자재 중 STS 300 계열의 금속보다 강도가 높고 용접성이 우수할 것이라고 판단되는 21-6-9 합금소재를 이용하여 산화제 주배관의 시편을 제작 하였다. 제작된 시편은 내압 시험을 수행하여 요구되는 내압 강도를 유지할 수 있는지를 확인하였다.

콘크리트 두께에 따른 질소투과계수 영향실험 (A Nitrogen Permeability Experiment with the Various Thickness of Concrete)

  • 이명규;정상화;김도현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.767-772
    • /
    • 2002
  • Using the diffusion cell, a experimental study on the nitrogen permeability was performed with the various thickness of concrete. This is important with relating to the carbonation study because the study of $CO_2$ diffusivity needs to use thin concrete specimen. Experimental results show that the nitrogen permeability is few affected by concrete specimen's thickness. But, specimens with 1cm thickness have a high permeability and deviation relatively. Also, specimens with w/c ratio 0.40 have a low permeability than 0.58. Consequently, the 3cm thickness is the better stable than others but the 1cm thickness specimens will be stable in case having a lot of specimens.

  • PDF