• Title/Summary/Keyword: Specimen thickness

Search Result 1,058, Processing Time 0.043 seconds

Effects of the cis-Dichlorodiammineplatinum on the Fine Structures of the Interalveolar Septum in the Mouse (cis-Dichlorodiammineplatinum (II) 이 생쥐 폐포간중격의 미세구조에 미치는 영향)

  • Baik, Tai-Kyeoung;Kwon, Ik-Seung;Kim, Won-Kyu;Baik, Doo-Jin;Chung, Ho-Sam;Lee, Kyu-Sik
    • Applied Microscopy
    • /
    • v.23 no.1
    • /
    • pp.35-55
    • /
    • 1993
  • cis-Dichlorodiammineplatinum (II) (cis-Platin), a metallic compound, has widely been used as an effective anticancer chemotherapeutic agent. The precise mechanism of action of this agent is still unknown, but it is postulated that cis-Platin may act on the cancer cell like bifunctional alkylating agents. Although this agent is very beneficial to the patients with cervical cancer, germinoma of testis, neuroblastoma and others, it may also damage to the normal cell so that many side effects; severe hemorrhagic enterocolitis, bone marrow depression, renal damage and liver damage will develope. This experiment has been undertaken to pursue the cytotoxic effects of the cis-Platin on the ultrastructures of the interalveolar septum in the mouse lung. A total of 55 healthy male mice of ICR strain were used as experimental animals and divided into 5 mice of normal control group and 50 mice of cis-Platin treated group. The mice of cis-Platin treated group were sacrificed by carotid exsanguination at 6, 12, 24 hours, 3 days and 7 days after intraperitoneal injection of 6.0 mg of cis-Platin ($Abiplatin^R$ Abic Co. Ltd.) per kg of mouse body weight. The specimen obtained from the lower lobe of left lung were sliced into $1mm^3$ and prefixed with 2% glutaraldehyde -2.5% paraformaldehyde solution prepared with Millonig's phosphatae buffer solution (pH 7.4) at $4^{\circ}C$ for 3-4 hours. After postfixation with 1% osmium tetroxide solution all specimens were embedded in Epon 812. Ultrathin sections about $600-800{\AA}$ in thickness were stained with uranyl acetate and lead citrate and observed with Hitachi-600 electron microscope. The results obtained were as follows: 1. Local swellings with increase of electron density and number of pinocytic vesicles in the cytoplasms of the type I pneumocyte and endothelial cell of the blood air barrier in interalveolar septum of cis-platin treated mice were observed. 2. Cisternae of rough endoplasmic reticulum were dilated and sacculated in association with detachment of membrane bound ribosomes of the type II pneumocyte in interalveolar septum of cis-Platin treated mice. 3. Swollon mitochondria with uneven electron density of their matrix were observed in the type II pneumocyte of interalveolar septum in the cis-Platin treated mice. 4. The lamellae of lammelar bodies in type II pneumocyte of interalveolar septum in cis-Platin treated mice were devoided or transformed into homogeneous electron dense material. It is consequently suggested that cis-Platin would induce the cellular edema of type I pneumocyte and endothelial cell, and degenerative changes of cytoplasmic organelles of the type II pneumocyte in the interalveolar septum of the mouse lung.

  • PDF

An Effect of $Al_{2}O_{3}$ on the Reaction between Molten Converter Slag and CaO pellet (용융전로(熔融轉爐)슬래그와 CaO펠렛의 상호반응(相互反應)에 미치는 $Al_{2}O_{3}$의 영향(影響))

  • Kim, Young-Hwan;Ko, In-Yong
    • Resources Recycling
    • /
    • v.15 no.2 s.70
    • /
    • pp.3-9
    • /
    • 2006
  • As a basic study on the conversion of molten converter slag to the ordinary portland cement, the effects of $Al_{2}O_{3}$ addition on the interface reaction between solid CaO and molten converter slag has been studied. Alumina added converter slag whose basicity was controlled to 1 and 2 was melted and hold for 30 minutes in MgO crucible at $1500^{\circ}C$. Then sintered CaO pellet heated at the same temperature was dipped into the molten slag and held for 30minutes. After the reaction, the crucible was cooled in air and the specimen was cut off to the horizontal direction of the crucible. The dissolution rate of CaO pellet with the addition of $Al_{2}O_{3}$ was measured by the change of the radius or sintered CaO pellet and the interface layer was observed by SEM/EDX. As a result. At the basicity 2 slag, thickness of created $C_{3}S$ layer increased 3.5 times and quantity of $C_{6}AF_{2}\;or\;C_{4}AF$ phase increase 2 times than baisicy 1 slag.

A STUDY ON THE RESPONSES OF OSTEOBLASTS TO VARIOUS SURFACE-TREATED TITANIUM

  • Lee Joung-Min;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.3
    • /
    • pp.307-326
    • /
    • 2004
  • Statement of problem. The long-term success of implants is the development of a stable direct connection between bone and implant surface, which must be structural and functional. To improve a direct implant fixation to the bone, various strategies have been developed focusing on the surface of materials. Among them, altering the surface properties can modify cellular responses such as cell adhesion, cell motility and bone deposition. Purpose. This study was to evaluate the cellular behaviors on the surface-modified titanium by morphological observation, cellular proliferation and differentiation. Material and methods. Specimens were divided into five groups, depending on their surface treatment: electropolishing(EP) anoclizing(AN), machining(MA), blasting with hydroxyapatite particle(RBM) and electrical discharge machining(EDM). Physicochemical properties and microstructures of the specimens were examined and the responses of osteoblast-like cells were investigated. The microtopography of specimens was observed by scanning electron microscopy(SEM). Surface roughness was measured by a three-dimensional roughness measuring system. The microstructure was analyzed by X-ray diffractometer(XRD) and scanning auger electron microscopy(AES). To evaluate cellular responses to modified titanium surfaces, osteoblasts isolated from neonatal rat were cultured. The cellular morphology and total protein amounts of osteoblast-like cell were taken as the marker for cellular proliferation, while the expression of alkaline phosphatase was used as the early differentiation marker for osteoblast. In addition, the type I collagen production was determined to be a reliable indicator of bone matrix synthesis. Results. 1. Each prepared specimen showed specific microtopography at SEM examination. The RBM group had a rough and irregular pattern with reticulated appearance. The EDM-treated surface had evident cracks and was heterogeneous consisting of broad sheet or plate with smooth edges and clusters of small grains, deep pores or craters. 2. Surface roughness values were, from the lowest to the highest, electropolished group, anodized group, machined group, RBM group and EDM group. 3. All groups showed amorphous structures. Especially anodized group was found to have increased surface oxide thickness and EDM group had titaniumcarbide(TiC) structure. 4. Cells on electropolished, anodized and machined surfaces developed flattened cell shape and cells on RBM appeared spherical and EDM showed both. After 14 days, the cells cultured from all groups were formed to be confluent and exhibited multilayer proliferation, often overlapped or stratified. 5. Total protein amounts were formed to be quite similar among all the group at 48 hours. At 14 days, the electropolished group and the anodized group induced more total protein amount than the RBM group(P<.05). 6. There was no significant difference among five groups for alkaline phosphatase(ALP) activity at 48 hours. The AN group showed significantly higher ALP activity than any other groups at 14 days(P<.05). 7. All the groups showed similar collagen synthesis except the EDM group. The amount of collagen on the electropolished and anodized surfaces were higher than that on the EDM surface(P<.05).

Effect of Accelerated Aging on the Color Stability of Dual-Cured Self-Adhesive Resin Cements

  • Kim, Ah-Rang;Jeon, Yong-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • Journal of Korean Dental Science
    • /
    • v.8 no.2
    • /
    • pp.49-56
    • /
    • 2015
  • Purpose: The effect of accelerated aging on color stability of various dual-cured self-adhesive resin cements were evaluated in this study. Materials and Methods: Color stability was examined using three different brands of dual-cured self-adhesive resin cements: G-CEM LinkAce (GC America), MaxCem Elite (Kerr), and PermaCem 2.0 (DMG) with the equivalent color shade. Each resin cement was filled with Teflon mold which has 6 mm diameter and 2 mm thickness. Each specimen was light cured for 20 seconds using light emitting diode (LED) light curing unit. In order to evaluate the effect of accelerated aging on color stability, color parameters (Commission Internationale de l'Eclairage, CIE $L^*$, $a^*$, $b^*$) and color differences (${\Delta}E^*$) were measured at three times: immediately, after 24 hours, and after thermocycling. The $L^*$, $a^*$, $b^*$ values were analyzed using Friedman test and ${\Delta}E^*$ values on the effect of 24 hours and accelerated aging were analyzed using t-test. These values were compared with the limit value of color difference (${\Delta}E^*=3.7$) for dental restoration. One-way ANOVA and Scheff's test (P<0.05) were performed to analyze each ${\Delta}E^*$ values between cements at each test period. Result: There was statistically significant difference in comparison of color specification ($L^*$, $a^*$, $b^*$) values after accelerated aging except $L^*$ value of G-CEM LinkAce (P<0.05). After 24 hours, color difference (${\Delta}E^*$) values were ranged from 2.47 to 3.48 and $L^*$ values decreased and $b^*$ values increased in all types of cement and MaxCem Elite had high color stability (P<0.05). After thermocycling, color change's tendency of cement was varied and color difference (${\Delta}E^*$) values were ranged from 0.82 to 2.87 and G-CEM LinkAce had high color stability (P<0.05). Conclusion: Color stability of dual-cured self-adhesive resin cements after accelerated aging was evaluated and statistically significant color changes occurred within clinically acceptable range.

A Study for Evaluation of Performance and Influence Factors for Steel Pipe Supports ( I ) (강제파이프서포트의 성능평가 및 영향요인에 대한 연구( I ))

  • Hwang Jung-Hyun;Shin Sang-Tae;Yun Sang-Moon;Kim Kyung-Hwa
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.2 s.80
    • /
    • pp.139-146
    • /
    • 2004
  • Recently, interest on the performance of the construction temporary equipment have been greatly increased. Since the application of the 'Performance Test Code' for the equipment in 1992 according to the Industrial Safety and Health Act, a basic study of Steel Pipe Supports have been carried out for the last 2 years based on the Performance Test Results. The present code specification for the Steel Pipe Supports and research status are introduced. So far, total 849 specimen have been examined on their outer and inner pipe's length, thickness, their overlapping length, and their load carrying capacities. The test was conducted separately into two groups - used and new equipment, and it was found that the used ones revealed a decrease on their load carrying capacity, almost $10\%$ compared to the new ones. Considering this fact, it is strongly recommended to ensure the quality of the equipment before use at the jobsite. First of all, based on this basic investigation, the statistical values on the Steel Pipe Supports are suggested and further analysis on the effect of each component is in progress. It is, however, expected that this report can be used as a basic information on the Steel Pipe Supports.

Translucency and Color Stability of Various Core Ceramics for All-Ceramic Restoration (전부도재수복물을 위한 수종의 코어 세라믹의 반투명도 및 색 안정성)

  • Oh, Sang-Chun;Lee, Hae-Hyoung;Shin, Mee-Ran;Park, Kwang-Su
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.2
    • /
    • pp.157-170
    • /
    • 2007
  • Purpose: This investigation was designed to determine the translucency and color stability of various core ceramics for all-ceramic restoration using the CIE $L^*a^*b^*$ system. Material and Methods: IPS e.max Press ceramic(Ivoclar-Vivadent, Liechtenstein), $LAVA^{TM}$ All Ceramic(3M-Espe, Germany), Cercon Smart Ceramic(Dentsply, Germany), and Z-match Ceramic(DentAim, Korea) were used for this study. For the specimens of zirconia oxide ceramics, the as-sintered cylindrical blanks($11.0{\times}25.0mm$) were machined into the shape of a disk(0.4, 0.8, 1.5 mm in thickness, 10 mm in diameters) with a diamond grind machine. The IPS e.max Press specimens ($0.8{\times}10mm$) were fabricated using the "lost wax" technique. CIE $L^*a^*b^*$ coordinates and light transmission were recorded for each specimen with a spectrophotometer(CM-2600d, Minolta, Japan). Color differences were calculated using the equation, ${\Delta}E^*ab=[({\Delta}L^*)2+({\Delta}a^*)2+({\Delta}b^*)2]1/2$. Results: The results were obtained as follows: 1. The most translucent group was IPS e.max Press ceramic that is a glass-ceramic, and $Lava^{TM}$ and Z-match ceramic were more translucent than Cercon Smart ceramic in zirconia ceramic group. 2. In the all groups, there was no significant translucent change after 6 times heat-treatments required to make a final restoration. 3. Colored zirconia was showed more yellowish and dark than uncolored zirconia. 4. After heat-pressing, IPS e.max Press ceramic was showed high ${\Delta}E^*ab$ value(4.1 of eM1, 6.8 of eM2) that means to be more whiter than before heat-pressing. However, there was no color change after additive heat treatments for final restoration. 5. In the colored zirconia groups, there was no significant color change after some heat-treatments required to make a final restoration.

THE EFFECT OF FERMENTED FOODS ON THE COLOR CHANGE OF SOFT DENTURE LINERS (발효음식에 의한 연성 의치상 이장재의 색상 변화에 관한 연구)

  • Cho Seong-Hwan;Lim Heon-Song;Shin Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.572-582
    • /
    • 2004
  • Statement of problem: The clinical criteria of soft lining materials are resilience over an extended period, capability of forming a strong bond with denture base materials, dimensional stability, adequate tear strength, and color stability. Many researches and reports dealt with food colorants or denture cleanser, but not with fermented foods. Purpose : This study was designed to assess what fermented foods, such as soy sauce and red pepper paste that many Koreans have eaten, influence on the color stability of soft denture liners. Material and methods: The color differences (${\Delta}E^*$) were measured by spectrophotometer with different immersion time. For the procedure, thirty disk-shape specimens per 4 soft denture linears(Molloplast-$B^{(R)}$, Ufi Gel $SC^{(R)}$, Dura $Base^{(R)}$, Sofreliner $MS^{(R)}$) were fabricated with a thickness of 2mm and 16mm in diameter. Each 10 specimen were immersed into the beakers of fermented foods distilled water, and $L^*$, $a^*$, $b^*$ values were measured for the color difference(${\Delta}E^*$), on the 1st, 7th, and 28th day with spectrophotometer. Result and conclusion : 1. There were significant differences between samples(soy sauces, red pepper pastes, and distilled water) in Sofreliner $MS^{(R)}$ of 1st day after immersion(p<0.05). There were significant differences between samples in Sofieliner $MS^{(R)}$ and Ufi Gel $SC^{(R)}$ of 7th days after immersion(p<0.05). There were significant differences between samples in Molloplast-$B^{(R)}$ of 28th day after immers ion(p<0.05). 2. In red pepper pastes, ${\Delta}E^*$ values of Molloplast-$B^{(R)}$, Ufi Gel $SC^{(R)}$, Sofrelinev $MS^{(R)}$ weve higher than 3.3. Those values were not clinically acceptable. In soy sauces, ${\Delta}E^*$ values of all denture liners were lower than 3.3. ${\Delta}E^*$values of Ufi Gel $SC^{(R)}$ were higher than those of other denture liners 3. Based on the above results , red pepper paste causes more discoloration than soy sauce.

Failure Characteristics of Scarf Patch-repaired Composite Single-lap Joints (스카프 패치로 수리한 복합재 단일겹침 체결부의 파손 특성 연구)

  • Kim, Choong-Hyun;Yoo, Jae-Seung;Byeon, Chang-Seok;Ju, Hyun-Woo;Park, Min-Young;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.29 no.3
    • /
    • pp.117-124
    • /
    • 2016
  • The failure strength of composite single-lap joint repaired using scarf patch was investigated by test and finite element method. A total of 45 specimens were tested changing scarf ratio, stacking pattern, and defect size to study the failure strength and mode. Except for one case, all repaired specimens showed the equal or higher strength than the sound specimens and the effect of considered repair parameters was not remarkable. It was found through the failure mode inspection that the surface treatment for bonding was not enough in the case which failed at the lower load than the sound specimen. Three-dimensional finite element analysis was conducted to verify the test results. It was confirmed that the considered repair parameters do not significantly affect the stress distribution of the specimens. It was also observed that the applied tensile load is relieved passing through the overlapped region thickness of which is almost double. From this study, it is concluded that if the bonding procedure for adherends and patch including surface treatment for fabric layer is thoroughly followed, the strength of repaired single-lap joint can be restored up to the strength of sound one.

The Corrosion Behavior of Hydrogen-Charged Zircaloy-4 Alloys (수소 장입된 Zircaloy-4 합금에서의 부식거동)

  • Kim, Seon-Jae;Kim, Gyeong-Ho;Baek, Jong-Hyeok;Choe, Byeong-Gwon;Jeong, Yo-Hwan
    • Korean Journal of Materials Research
    • /
    • v.8 no.3
    • /
    • pp.268-273
    • /
    • 1998
  • Standard Zircaloy-4 sheets, charged with 230-250ppm hydrogen by the gas-charging method and homogenized at $400^{\circ}C$ for 72hrs in a vacuum, were corroded in pure water and aqueous LiOH solutions using static autoclaves at $350^{\circ}C$. Their corrosion behaviors were characterized by measuring their weight gains with the corrosion time and observing their microstructures using an optical microscope and a scanning electron microscope. The elemental depth profiles for hydrogen and lithium were measured using a secondary ion mass spectrometry(S1MS) to confirm their distributions at the oxidelmetal interface. The normal Zircaloy-4 specimens corroded abruptly and heavily at the concentration of Li ions more than 30ppm in the aqueous solution. This is due to accelerations by the rapid oxidation of many Zr- hydrides formed by the large amount of absorbed hydrogen, resulting from the increased substitution of $Li^{+}$ ions with $Zr^{4+}$-sites in the oxide as the Li ion concentration increased. The specimens that had been charged with amounts of hydrogen greater than its solubility corroded early with a more rapid acceleration than normal specimens, regardless of the corrosion solutions. At longer corrosion times. however, normal specimens showed a rather accelerated corrosion rate compared to the hydrogen-charged specimens. These slower corrosion rates of the hydrogen-charged specimens at the longer corrosion times would be due to the pre-existent Zr-hydride in the matrix, which causes the hydrogen pick- up into the specimen to be depressed, when the oxide with an appropriate thickness formed.

  • PDF

REMOVAL PATTERNS OF SMEAR LAYER ACCORDING TO APPLICATION TEMPERATURE AND TIME OF EDTA (EDTA의 적용 온도와 시간에 따른 도말층의 제거양상)

  • Shin, Jang-Shik;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.535-542
    • /
    • 2002
  • The purpose of this study was to evaluate the effect of EDTA irrigant according to application time and temperature. 31 human mature extracted teeth with a single canal were sectioned with microtome in 3mm thickness and gained 62 samples of root canals. They were distributed randomly into 6 groups of 10 specimens each and control group of 2 specimens. Each specimen was prepared with GT rotary file (Dentsply, Maillefer Co., Swiss) and irrigated with 3 ml sodium hypochlorite every minute. Then smear layer was removed with EDTA solution (PULPDENT$^{\circledR}$, PULPDENT Co., USA.) except two control specimens. Specimens of each group were irrigated with 17% EDTA. The time and temperature of application were as follows : (Table omitted) All specimens were split longitudinally and prepared for examination by scanning electron microscopy. A set of reference micrographs was used to award a debris score as follows: 0 = no smear layer, all tubules clean and open; 1 = no superficial smear layer, tubule openings visible, but some contain debris plug or soft tissue remnants: 2 = moderate smear layer, some tubules open and others closed; 3 = heavy smear layer, most/all tubule openings obscured. Results were evaluated with Kruskal-Wallis test to determine whether there was statistically significant difference among six groups. Pairs of groups were analyzed using the Student-Newman-Keuls Method and Mann-Whitney test. The results were as follows : 1. Control specimens showed heavy smear layer at the canal walls 2. Among the groups applied with EDTA for 2 minutes, group 1 showed the heaviest smear layer, and there was statistically significant difference between group 1 and the other groups(p<0.05). 3. Among the groups applied with EDTA for 5 minutes, group 4 and group 6 showed smear layer but there was no significant difference between them. 4. Among the groups applied with EDTA for the same temperature, group 1 showed heavier smear layer than group 4, and there was statistically significant difference(p<0.05). 5. Among the groups applied with EDTA for the same temperature, group 2 showed heavier smear layer than group 5 and group 3 showed heavier smear layer than group 6. But there was no statistically significant difference among them. From the results above, it could be concluded, EDTA solution is effective in removing of smear layer when it is applied for 5 minutes. If EDTA is applied for 2 minutes, it should be applied above room temperature.