• Title/Summary/Keyword: Specific Absorption (SAR)

Search Result 106, Processing Time 0.02 seconds

Implementation about measurement of the head SAR and variable parameter according to operation control mode in brain MR study with 1.5Tesia (1.57 BRAIN MRI검사에서의 작동제어모드를 통한 두부 SAR측정과 변화인자에 관한 고찰)

  • Lee, Kyu-Su;Sim, Hyun;Moon, Ji-Hoon;Oh, Jae-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.58-60
    • /
    • 2007
  • Magnetic Resonance Imaging(MRI) has become a very widely used medical procedur e. Clo.sed and open systems are typically used with static magnetic fields at or below 2 Tesla. BWhole body SAR(specific absorbsion rate) is the value of SAR averaged over the entire body of the patient over any period of 15 minutes. Head SAR is the value of SAR averaged over the head of the patient for any period of 10 minutes. SAR is a measure of the absorption of electromagnetic energy in the body' (typically in watts per kilogram (W/kg)). The normal operating mode comprises values of head SAR not higher than 3 W/kg. The second level controlled operating mode comprises values higher than 3 W/kg. Current FDA guidance limits the SAR in the whole body. including the head to a range of 1.5 to 4.0 W/kg, depending on the patient's clinical condition. SAR, limit restrictions are incorporated in all MRI systems. and domestic' s guidance limits the SAR in a part body. including the head to 3.2w/kg and less. The purpose of this study is to evaluate on change of head SAR in using MRI pulse sequence and to check if exceed 3.2(w/kg) level in domestic a part exposure through measured head SAR. 23 patient's the average head SAR of pulse sequence is that T2WI sagittal is 0.5375. T2WI axial(FSE) is 0.4817, T1WI axial(SE) is, 0.8179. FLAIR axial is 0.4580. GRE axial is 0.0077, Diffusion is 0.0824w/kg. The head SAR exposed per patient was proved 2.3845w/kg less than the international standard. Coefficient of correlation for the relations body weight and SAR or for the relations ETL(echo train length) and SAR is 1 value. Coefficient of correlation for the relations between TR(time to repeat) and SAR is -0.602 value. so SAR increased relative to weight body and ETL. But the relations between TR and SAR is negative definite.

  • PDF

Dosimetry for Resonance-Based Wireless Power Transfer Charging of Electric Vehicles

  • Park, Sang-Wook
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.129-133
    • /
    • 2015
  • This paper presents the dosimetry of a resonance-based wireless power transfer (RBWPT) system for electric vehicles applications. The compact RBWPT system is designed to transfer power at 150-mm distance. The electric and magnetic fields generated by the RBWPT system and the specific absorption rate in the human body model, which stands around the system, are calculated. These analyses are conducted in two cases: the alignment and the misalignment between the transmitter and the receiver. The matching loops are adjusted to maximize the power transfer efficiency of the RBWPT system for the misalignment condition. When the two cases were compared for the best power transfer efficiency, the specific absorption rates (SAR) in the misalignment case were larger than those in the alignment case. The dosimetric results are discussed in relation to the international safety guidelines.

Comparison with SAR Patterns of Biological Objects Contacted with Coaxial Waveguide Antenna Using MUR and GPML ABCs in the FDTD Method (유한차분법에서 MUR과 GPML 흡수경계조건을 이용한 동축 도파관 안테나에 접촉된 생체의 SAR 패턴 비교)

  • 구성모;권광희;이창원;원철호;조진호
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.2
    • /
    • pp.149-158
    • /
    • 1998
  • The SAR patterns of biological objects contacted with coaxial waveguide antennal has been investigated, in which the biological object was modeled by a homogeneous and four-layered lossy human body. We derived the finite-difference time-domain(FDTD) algorithm and equation of MUR and generalized perfectly matched layer(GPML) ABCs in cylindrical coordination. The coupling between coaxial waveguide antenna and a biological object was analyzed by use of MUR and GPML ABCs in the FDTD method to obtain the absorbed power patterns in the media. The specific absorption rates (SAR) distribution which was corresponding to the temperature distribution was calculated in each region by use of the steady-state response in the FDTD method. The SAR patterns of the FDTD method using MUR absorbing boundary conditions(ABCs) was compared with those of the FDTD method using GPML ABCs. The comparison exhibits that the penetration depth of the SAR patterns using MUR ABCs is deeper than that of the SAR patterns using GPML ABCs because of loss in free space. However, the spread in the lateral directions of the SAR patterns using GPML ABCs is smaller than of the SAR patterns using MUR ABCs.

  • PDF

Comparison and Optimization of Parallel-Transmission RF Coil Elements for 3.0 T Body MRI (3.0 T MRI를 위한 병렬전송 고주파 코일 구조 비교와 최적화)

  • Oh, Chang-Hyun;Lee, Heung-K.;Ryu, Yeun-Chul;Hyun, Jung-Ho;Choi, Hyuk-Jin
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.55-60
    • /
    • 2007
  • In high field (> 3 T) MR imaging, the magnetic field inhomogeneity in the target object increases due to the nonuniform electro-magnetic characteristics of the relatively high RF frequency. Especially in the body imaging, the effect causes more serious problems resulting in locally high SAR(Specific Absorption Ratio). In this paper, we propose an optimized parallel-transmission RF coil and show the utility of the coil by FDTD simulations to overcome the unwanted effects. Three types of TX coil elements are tested to maximize the efficiency and their driving patterns(amplitude and phase) optimized to have adequate field homogeneity, proper SAR level, and sufficient field strength. For the proposed coil element of $25cm{\times}8cm$ loop structure with 12 channels for a 3.0 T body coil, the field non-uniformity of more than 70% without optimization was reduced to about 26 % after the optimization of driving patterns. The experimental as well as simulation results show that the proposed parallel driving scheme is clinically useful for (ultra) high field MRI.

Children's Mobile Phone Use and Dosimetry

  • Lee, Ae-Kyoung;Kwon, Jong-Hwa
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.167-172
    • /
    • 2015
  • Research results on possible effects caused by radiofrequency fields in children are limited because most of the studies published so far have focused on adults, rather than children. Mobile phone use is now widespread, even among younger children. If a biological risk due to mobile phone exposure is found, it might be greater in children because their bodies might be more sensitive to radiofrequency energy. The issue of a possible difference in sensitivity between adults and children begins with whether any difference exists physically in terms of electromagnetic absorption. This paper presents a review of recent publications on dosimetric comparisons between children and adults with respect to radiation from mobile phones. The issue of the health effects of mobile phone use is beyond the scope of the present review. Most of the dosimetry research on possible differences in power absorption between children and adults has been based on numerical modeling and analysis. The understanding of the results so far is presented and needed studies are described.

SAR Pattern of Biological Objects Contacted with Coaxial Waveguide Using the FDTD Method

  • Koo, Sung-Mo;Won, Chul-Ho;Lee, Chang-Won;Cho, Jin-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.185-188
    • /
    • 1996
  • Noninvasive multifrequency microwave radiometry using coaxial waveguide antenna has been investigated for a homogeneous and four layer human body model. The coupling between coaxial waveguide antenna and a. biological object is analyzed by use of the FDTD method to obtain the absorbed power patterns in the media. The object studied in this paper is a homogeneous and four-layered lossy medium. The specific absorption rates(SAR) distribution is calculated in each region by use of the steady-state response in FDTD method.

  • PDF

Computation of Temperature Rising by Absorbed Power Radiated from a Portable Phone (휴대폰 전파인 인제 흡수전력량과 온도 상승량 산출)

  • 이승학;김채영;강승진
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.3
    • /
    • pp.409-426
    • /
    • 2001
  • Absorbed power of the human head radiated from a 900 MHz portable phone and temperature rise are computed using FDTD(Finite-Difference Time-Domain) method. For this computation the 5 layered media for the human head modeling and the monopole antenna attached to metallic box for the portable phone are used. To reflect the real circumstances typical sizes of human heads and portable phones are considered in the calculation. The length of monopole antenna is 8.15 cm, and the output power of a phone is 600 mW. Under the predetermined model the distribution of 1 g, 10 g averaged SAR and temperature rise rate over the human head are calculated, from which it was found that the position of maximum SAR is near at the head skin surface, not deep places far into the head. The position of the highest temperature is located far from the head skin more than that of the maximum SAR occured. The averaged SAR and temperature along the distance between the head and phone are calculated according to seperation distance between the head and phone.

  • PDF

Comparison and Optimization of Parallel-Transmission RF Coil Elements for 3.0 T Body MRI (3.0 T MRI를 위한 Parallel-Transmission RF 코일 구조의 비교와 최적화)

  • Oh, Chang-Hyun;Lee, Heung-K.;Ryu, Yeun-Chul;Hyun, Jung-Ho;Choi, Hyuk-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.61-63
    • /
    • 2007
  • In high field (> 3 T) MR imaging, the magnetic field inhomogeneity in the target object increases due to the nonuniform electro-magnetic characteristics and relatively high Larmor frequency. Especially in the body imaging, the effect causes more serious problems resulting in locally high SAR(Specific Absorption Ratio). In this paper, we propose an optimized parallel-transmission RF coil element structure and show the utility of the coil by FDTD simulations to overcome the unwanted effects. Three types of TX coil elements are tested to maximize the efficiency and their driving patterns(amplitude and phase) optimized to have adequate field homogeneity, proper SAR level, and sufficient field strength. For the proposed coil element of 25 cm ${\times}$ 8 cm loop structure with 12 channels for a 3.0 T body coil, the 73% field non-uniformity without optimization was reduced to about 26% after optimization of driving patterns. The experimental as well as simulation results show the utility of the proposed parallel driving scheme is clinically useful for (ultra) high field MRI.

  • PDF

Effects of 835-MHz Radiation on the Intracellular Calcium, Reactive Oxygen Species, and F-actin Polymerization in Rat-2 Fibroblasts

  • Hong Sae-Yong;Lee Zee-Won;Son Tae-Ho;Chang Sung-Keun;Choi Jong-Soon
    • Biomedical Science Letters
    • /
    • v.12 no.1
    • /
    • pp.9-16
    • /
    • 2006
  • We investigated the effects of 835-MHz electromagnetic field (EMF), one of the most popular communication frequency band in Korean code-division multiple-access (CDMA) mobile phone system, on cellular signal transduction. For this, we examined the change of intracellular calcium $([Ca^{2+}]_i)$, reactive oxygen species (ROS) and F-actin polymerization after exposure to 835-MHz EMF followed by the treatment of agonists in Rat-2 fibroblast cells. Culture cells were pretreated with serum-tree medium and concomitantly exposed to 835-MHz at specific absorption rate (SAR) of 4.0 W/kg for 24 hr in a specialized designed apparatus based on Transverse Electro Magnetics (TEM) wave theory. Intracellular $Ca^{2+}$ responses to lysophosphatidic acid (LPA) and epidermal growth factor (EGF) in Rat-2 fibroblast after exposure to 835-MHz EMF were shown to be similar pattern as observed in normal cultured cells. However, the LPA-induced calcium spiking was slightly delayed to 7 sec and sustained thereafter to a little higher ground level under 835-MHz EMF radiation compared to unexposed cells. ROS production level by LPA in the exposed cells was not different from that in control. Furthermore, LPA induced the production of stress fibers with no significant difference in the exposed and unexposed cells. These results suggest that mobile phone radiation (835-MHz, SAR 4.0 W/kg) may not be directly related to signal transduction in Rat-2 fibroblasts except the slight effect of calcium spiking in LPA-induced cells but remain to be further elucidated for possible indirect intervention.

  • PDF

Research on An Equivalent Antenna Model for Induced Human Body Current by RFID Reader Antenna of HF Band (단파(HF) 대역 RFID 리더 안테나에 의한 인체 유도 전류의 등가 안테나 모형 연구)

  • Lee, Jong-Gun;Byun, Jin-Kyu;Choi, Hyung-Do;Cheon, Chang-Yul;Lee, Byung-Je;Chung, Young-Seek
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.6
    • /
    • pp.503-508
    • /
    • 2009
  • There are many researches on human effect by electromagnetic equipments and applications. However, most of research and guidelines for limiting human exposure to electromagnetic fields are established by mobile communication of SAR(Specific Absorption Ratio). Therefore we need to study different effects on human body when exposed to high frequency(HF) band equipments, such as human induced current etc. In this paper, we measured human induced current by RFID reader antenna of HF band in the near field and we propose human equivalent antenna which has orthogonal loops to each other. Then, we compared the induced currents on proposed equivalent antenna with human.