• Title/Summary/Keyword: Speaker Sound

Search Result 267, Processing Time 0.025 seconds

Design of High-efficiency Power Amplifier System for High-directional Speaker (고지향성 스피커를 위한 새로운 전력 증폭기 설계)

  • Kim, Jin-Young;Kim, In-Dong;Moon, Wonkyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.8
    • /
    • pp.1215-1221
    • /
    • 2017
  • Parametric array transducers are used for highly directional speaker in an air environments. Piezoelectric micromachined ultrasonic transducers for parametric array transducers need DC-biased voltage driving signals in order to get high-directional quality-sound features. The existing power amplifier such as class A amplifiers has low efficiency and require large volume heatsinks. To overcome the above-mentioned disadvantages of the conventional amplifier, this paper proposes a new power amplifier system. The proposed power amplifier system ensures high linearity of output characteristic by utilizing the push-pull class B type amplifier. Furthermore, the proposed power amplifier system gets high efficiency because it contains the DC-DC converter-type power supply which can perform energy recovery and envelope tracking function. Also the paper suggests the detailed circuit topology. Its characteristics are verified by the detailed experimental results.

An Acoustic Study of English Non-Phoneme Schwa and the Korean Full Vowel /e/

  • Ahn, Soo-Woong
    • Speech Sciences
    • /
    • v.7 no.4
    • /
    • pp.93-105
    • /
    • 2000
  • The English schwa sound has special characteristics which are distinct from other vowels. It is non-phonemic and occurs only in an unstressed syllable. Compared with the English schwa, the Korean /e/ is a full vowel which has phonemic contrast. This paper had three aims. One was to see whether there is any relationship between English full vowels and their reduced vowel schwas. Second was to see whether there is any possible target in the English schwa sounds which are derived from different full vowels. The third was to compare the English non-phoneme vowel schwa and the Korean full vowel /e/ in terms of articulatory positions and duration. The study results showed that there is no relationship between each of the full vowels and its schwa. The schwa tended to converge into a possible target which was F1 456 and F2 1560. The Korean vowel /e/ seemed to have its distinct position speaker-individual which is different from the neutral tongue position. The evidence that the Korean /e/ is a back vowel was supported by the Seoul dialect speaker. In duration, the English schwa was much shorter than the full vowels, but there was no significant difference in length between the Korean /e/ and other Korean vowels.

  • PDF

Cyber Threats Analysis of AI Voice Recognition-based Services with Automatic Speaker Verification (화자식별 기반의 AI 음성인식 서비스에 대한 사이버 위협 분석)

  • Hong, Chunho;Cho, Youngho
    • Journal of Internet Computing and Services
    • /
    • v.22 no.6
    • /
    • pp.33-40
    • /
    • 2021
  • Automatic Speech Recognition(ASR) is a technology that analyzes human speech sound into speech signals and then automatically converts them into character strings that can be understandable by human. Speech recognition technology has evolved from the basic level of recognizing a single word to the advanced level of recognizing sentences consisting of multiple words. In real-time voice conversation, the high recognition rate improves the convenience of natural information delivery and expands the scope of voice-based applications. On the other hand, with the active application of speech recognition technology, concerns about related cyber attacks and threats are also increasing. According to the existing studies, researches on the technology development itself, such as the design of the Automatic Speaker Verification(ASV) technique and improvement of accuracy, are being actively conducted. However, there are not many analysis studies of attacks and threats in depth and variety. In this study, we propose a cyber attack model that bypasses voice authentication by simply manipulating voice frequency and voice speed for AI voice recognition service equipped with automated identification technology and analyze cyber threats by conducting extensive experiments on the automated identification system of commercial smartphones. Through this, we intend to inform the seriousness of the related cyber threats and raise interests in research on effective countermeasures.

The Effect of Sound Reinforcement Systems on the Acoustics of a Large-Span Spaces (대공간에서 전기음향 시스템에 따른 음향특성 변화)

  • Jeong, Dae-up;Joo, Hyun-kyung;Choi, Young-Ji
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.1
    • /
    • pp.67-75
    • /
    • 2011
  • The present work investigate the effect of sound reinforcement systems on the acoustics of a large dome stadium using a computer simulation. The acoustics of a dome stadium was predicted analyzed by varying room absorption, as well as the configuration of speakers including their directivity, installed height, and numbers. It was found that both D50 and RASTI were improved by increasing room absorption. Larger EDTs were observed according to the increase of room absorption at mid and high frequencies. On the other hand, RT did not show any significant correlation with the changes in room absorption, which might be the effect of a forced linear fitting for non -linear energy decay process. With respect to the speaker configuration, the speech intelligibility of a sound reforcement system installed at higher placed more relied upon their directivity rather than room absorption, Also, lower placing of speakers was found to be effective in decreasing RTs regardless of room absorption.

Subjective Evaluation of Loudspeaker Layouts for a Large Dome (대공간 스피커 배치 방식의 주관적 평가 연구)

  • Jeong, Dae-Up;Choi, Young-Ji;Kim, Jeong-Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.3
    • /
    • pp.75-80
    • /
    • 2010
  • The present study tried to provide useful data for the acoustic design of sound amplification system with measuring and analyzing subjective preference and intelligibility by varying the number of speakers and their directivity. The results suggest that the room absorption plays a key role in subjective responses of listeners and the large sound absorption of ceiling contributes to the increase of intelligibility. Also, larger number of speakers with narrow directivity improves perceived intelligibility when speakers were installed at the lower height. However, the highest degree of intelligibility and preference were obtained when speakers were installed close enough to the sound absorptive ceiling. The highest intelligibility and preference were observed when 8 to 10 speakers with the directivity of 60 degree were used.

  • PDF

Effect of Airborne Noise from Ship Machinery on Underwater Noise (선박의 장비 공기소음이 수중소음에 미치는 영향)

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kim, Bong-Ki;Kim, Sang-Ryul;Lee, Seong-Hyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.6
    • /
    • pp.569-574
    • /
    • 2011
  • In research vessels or naval ships, airborne noise from machineries such as diesel engine is the major source of underwater noise at low speed. In this paper, effect of engine noise on underwater noise is studied by considering two paths; sound radiation from hull plate and direct airborne noise transmission through hull plate. SEA (Statistical energy analysis) is used to predict hull plate vibration induced by engine noise, where SEA model consists of only two subsystems; engine room air space and hull plate. The pressure level in water is calculated from sound radiation by plate. Engine noise transmission through hull plate is obtained by assuming plane wave propagation in air-limp plate-water system. Two effects are combined and compared to the measurement, where speaker is used as a source in engine room and sound pressure levels in engine room and water are measured. The hydrophone is located 1 m away from the hull plate. It is found below 1000 Hz, prediction overestimates underwater sound pressure level by 5 to 12 dB.

Tonal development and voice quality in the stops of Seoul Korean

  • Yu, Hye Jeong
    • Phonetics and Speech Sciences
    • /
    • v.10 no.4
    • /
    • pp.91-99
    • /
    • 2018
  • Korean stops are currently undergoing a tonogenetic sound change, as found in the Seoul dialect in which a merged VOT of aspirated and lax stops induces F0 to be the primary cue for distinguishing the two stops and the lax stops have lower F0 than the aspirated stops. In tonal languages, low tone is produced with a breathy voice. This study investigated whether there are changes in voice quality with respect to the tonogenetic sound change of Korean stops. Two age groups speaking the Seoul dialect participated in this study: five females and six males born in the 1940s and 1950s and nine females and eight males born in the 1980s and 1990s. This study replicated previous findings of VOT and F0 and further examined H1-H2, H1-A1, and H1-A2 to see how they correlate with the sound change. In the older and younger generations, H1-H2, H1-A1, and H1-A2 were significantly lower after the tense stops than after the aspirated and lax stops, but they were not significantly different after the aspirated and lax stops. However, the younger females exhibited some different results for H1-H2 and H1-A2 than the older generation. In the younger females, the H1-H2 mean was higher after the aspirated stops than it was after the lax stops at the vowel onset, and the H1-H2 difference increased at the vowel midpoint. Although there was an inter-speaker variation in the results of H1-H2 and H1-A1, analyses of individual speakers showed that the H1-H2 and H1-A1 were higher after the lax stops than after the aspirated stops in the younger female speakers. These results indicate that lax stops tend to be breathier than aspirated stops in the younger female speakers. They also indicate that changes in voice quality are on Korean stops with tonal sound change, but are still developing.

Sound System Design and Characteristic Analysis based on Power Line Communication (전력선통신 기반 음향 시스템 설계 및 특성 분석)

  • Kim, Kwan-Kyu;Yeom, Keong-Tae;Kim, Kwan-Woong;Kim, Yong-Kab
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.6
    • /
    • pp.1-7
    • /
    • 2008
  • The paper is to solve the problem of existing sound system, which has difficulties of system organization and the increase of additional install cost and unfriendly interior. To solve the existing system, we drew the new sound system based on PLC and studied it. A transmitter and a receiver were designed using the PLC chip INT5500CS. Sound system was configured with a CD player that sound signals are sent from the transmitter and a speaker connected to the receiver. For analysis of characteristics of this system, a USBPre external sound card and Smaart Live 5 which is a PC-based sound measuring program were added. As a result of our experiment, the measured signal level is $2{\sim}3$[dB] lower than reference signal, latency is 16.69[ms] and the specific character of coherency is bad in high frequency band. Otherwise, this system transmits and receives signals over 90[%] in good condition as a result of measuring pink noise, frequency(1kHz), and phase, magnitude. In view of the result so far achieved, the system designed our team has excellent performance, it resolves defect of existing audio signal transmition system.

Development of Safe Stove System using Sound Wave Fire Extinguisher (음파 소화기를 이용한 안전 스토브 시스템 개발)

  • Seo, Yunwon;Lee, Sukjae;Park, yungjoo;Kim, Kinam;Choi, Yongrae;Hwang, Hyungjun;Han, Seunghan;Shim, Dongha
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.34-39
    • /
    • 2018
  • In this paper, the architecture of a safe stove with an automatic fire suppression function using a sound wave fire extinguisher has been proposed and developed for the first time. A microcontroller connected to a fire sensor detects and suppresses a fire by driving a fire extinguisher. The sound wave fire extinguisher is composed of a speaker and collimator, and is driven by a driver module including an audio amplifier. The attenuation of the sound wave is reduced by preventing the sound diffusion with an enclosure surrounding a stove. The frequency of the sound wave is set to 50 Hz, and the sound pressure of 93 dBA is measured at the distance of 0.5 m. It takes maximum 8 and 15 seconds to suppress the flame from 7-cc and 14-cc flammable liquid, respectively, which corresponds to 24% and 42% of the natural extinguishing time. Since the proposed safe stove is non-toxic and leaves no residues over the conventional ones, it would combine with various home appliances to suppress early-stage fires and prevent fire expansion.

Design and Analysis of Experimental Anechoic Chamber for Localization

  • Kim, Keon-Wook
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.4
    • /
    • pp.225-234
    • /
    • 2012
  • The anechoic chamber is essential tool to measure the various acoustic parameters with high precision. The chamber provides the climate controlled indoor environments but requires the dedicated room at a great cost in order to isolate and absorb sound field. Provided the purpose of the chamber is specific to the experiments of sound localization, the performance requirements excluding free field can be alleviated for cost effective solution. This paper designs low cost and profile anechoic chamber based on acoustic pyramids and evaluates the performance specified by the Annex of ISO 3745. Data analysis is employed to measure the free and hemi-free field performance over five straight paths for working areas and four paths for non-working areas. The identical two measurement campaigns were conducted for free and hemi-free field chamber which is easily interchangeable by simple labor in this chamber design. In the working area with conventional speaker, the results of these analyses demonstrate that lab-designed anechoic chamber is in conformance with ISO 3745 for 250 Hz - 16 kHz one-third octave band at free field chamber and for 1 kHz - 16 kHz one-third octave band at hemi-free field chamber.