• Title/Summary/Keyword: Spacing Distance

Search Result 273, Processing Time 0.021 seconds

Effect of Plant Density on Growth Responses and Yield in Yacon

  • Ryu, Jeom-Ho;Doo, Hong-Soo;Lee, Kang-Soo;Park, Sun-Young
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.46 no.5
    • /
    • pp.407-410
    • /
    • 2001
  • This study was conducted to determine the optimal planting distance in cultivation of yacon (Polymnia sonchifolia Poeppig & Endlicher). Plug seedlings were planted with 6 different plant densities of 80 $\times$ 60, 80 $\times$ 50, 70 $\times$ 50, 70 $\times$ 45, 70 $\times$ 40 and 60 $\times$ 45 cm. The plant height and the petiole length were increased with increasing the planting distance. The tallest plant height of yacon was 165.4cm with the plant density of 80 $\times$ 60 cm. However, branch number per plant, leaf number on main stem and stem diameter were not significantly difference among planting densities. Tuberous root was harvested 31.42 tons/ha in 70 $\times$ 50 cm spacing. The ratio of heavier tuberous roots than 200 g to total tuberous roots decreased significantly according to increase of planting density. Fresh weights of shoot and root, contain the crown bud, were decreased, as planting distance was shorter. Tuberous root number was fewer but its weight was heavier in wide planting than in dense planting. We think that optimal planting density is about 30,000 plants/ha, if it were to be 70 cm row spacing, intrarow spacing should calculate about 47cm.

  • PDF

Measurement System of Photosynthetic Photon Flux Distribution and Illumination Efficiency of LED Lamps for Plant Growth

  • Lee, Jae Su;Kim, Yong Hyeon
    • Journal of Biosystems Engineering
    • /
    • v.37 no.5
    • /
    • pp.314-318
    • /
    • 2012
  • Purpose: This study was conducted to develop a measurement system for determining photosynthetic photon flux (PPF) distribution and illumination efficiency of LED lamps. Methods: The system was composed of a linear moving sensor part (LMSP), a rotating part to turn the LMSP, a body assembly to support the rotating part, and a motor controller. The average PPF of the LED lamp with natural cooling and water cooling was evaluated using the measurement system. Results: The PPF of LED lamp with water cooling was 3.1-31.7% greater than that with natural cooling. Based on the measured value, PPF on the horizontal surface was predicted. Illumination efficiency of the LED lamp was slightly increased with water cooling by 3.4%, compared with natural cooling. A simulation program using MATLAB was developed to analyze the effects of the vertical distance from lighting sources to growing bed, lamp spacing, and number of LED lamps, on the PPF distribution on the horizontal surface. The uniformity of the PPF distribution of the LED lamps was fairly improved with 15 cm spacing, as compared to the 5 cm spacing. By simulation, PPF of $217.0{\pm}27.9{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ was obtained at the vertical distance of 40 cm from six LED lamps with 12 cm spacing. This simulated PPF was compared to the measured one of $225.9{\pm}25.6{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. After continuous lighting of 346 days, the relative PPF of LED lamps with water cooling and natural cooling was decreased by 6.6% and 22.8%, respectively. Conclusions: From these results, it was concluded that the measurement system developed in this study was useful for determining PPF and illumination efficiency of artificial lighting sources including LED lamp.

Development of an Evaluation Index for Identifying Freeway Traffic Safety Based on Integrating RWIS and VDS Data (기상 및 교통 자료를 이용한 교통류 안전성 판단 지표 개발)

  • Park, Hyunjin;Joo, Shinhye;Oh, Cheol
    • Journal of Korean Society of Transportation
    • /
    • v.32 no.5
    • /
    • pp.441-451
    • /
    • 2014
  • This study proposes a novel performance measure, which is referred to as Hazardous Spacing Index (HSI), to be used for evaluating safety of traffic stream on freeways. The basic principle of the proposed methodology is to investigate whether drivers would have sufficient stopping sight distance (SSD) under limited visibility conditions to eliminate rear-end crash potentials at every time step. Both Road Weather Information Systems (RWIS) and Vehicle Detection Systems (VDS) data were used to derive visibility distance (VD) and SSD, respectively. Moreover, the K-Nearest Neighbors (KNN) method was adopted to predict both VD and SSD in estimating predictive HSIs, which would be used to trigger advanced warning information to encourage safer driving. The outcome of this study is also expected to be used for monitoring freeway traffic stream in terms of safety.

Impingement heat transfer within 1 row of circular water jets: Part 2-Effects of nozzle to heated surface distance (1열 원형 충돌수분류군에 의한 열전달의 실험적 연구 (제2보, 노즐-전열면간 거리의 영향))

  • 엄기찬;이종수;김상필
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.1
    • /
    • pp.59-66
    • /
    • 2000
  • In a previous paper, we have examined the effects of nozzle configuration and jet to jet spacing on the heat transfer of 1 row of circular water jets. In this paper, experiments have been conducted to obtain the effects of nozzle to target plate distances on the heat transfer of 1 row of 3 jets and 1 row of 5 jets. The nozzle configurations are Cone type, Reverse cone type and Vertical circular type. Nozzle to target plate distance H was varied from 16 mm(H/D=2) to 80mm(H/D=10). For fixed value of mass flow rate and nozzle to target plate distance, larger values of average Nusselt number were obtained for the smaller jet to jet spacing. For the array of water jets, the average heat transfer was decreased slightly with increasing nozzle to target plate distance at low jet velocity of $\textrm{V}_{o}$=3 m/s. However, except for $\textrm{V}_{o}$=8 m/s of 1 row of 5 jets, it was increased with increasing nozzle to target plate distance at high jet velocity of $\textrm{V}_{o}$$\geq$6m/s. We proposed to apply the nozzle configuration of maximum average heat transfer to each nozzle to target plate distance for 1 row of 3 jets, and, it was Reverse cone type nozzle for 1 row of 5 jets(Reynolds number$\geq$36000).

  • PDF

Effect of Subsurface Drip Pipes Spacing on the Yield of Lettuce, Irrigation Efficiency, and Soil Chemical Properties in Greenhouse Cultivation (지중 점적관수 호스 설치 간격이 상추 수량, 관수량 및 토양 화학성에 미치는 영향)

  • Park, Jin Myeon;Lim, Tae Jun;Lee, Seong Eun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.5
    • /
    • pp.683-689
    • /
    • 2012
  • This research was carried out to investigate the effect of installation spacing of subsurface drip irrigation pipe on the mineral content, nutrient uptake, yield of lettuce, water requirement for irrigation, and soil chemical properties in greenhouse cultivation. Semi-forcing and retarding culture were implemented in this experiment, with four treatments containing overhead spray irrigation and three subsurface irrigation lateral spacing intervals of 30, 40, 50 cm at a depth of 30 cm from soil surface, respectively. Each mineral content of lettuce grown under subirrigation system did not show significant difference between treatments, however the uptake of nutrients was lower at 50 cm-distance. The yield was largest in 30 cm-subirrigation (SI), followed by 40 cm-SI, overhead spray, and 50 cm-treatment. Water requirement for irrigation was highest in overhead spray, and it was in reverse proportion to the distance of irrigation pipes. $NO_3$-N content in the soil, at a depth of 10 cm, showed a higher value in 50 cm-SI, followed by 40 cm-SI, overhead spray and 30 cm-SI. Exchangeable K content was highest in 50 cm-SI, Mg was highest in 40 cm-SI, and Ca was lowest in 30 cm-SI. In conclusion, the lettuce yield was not different between 30 and 40 cm-SI, but water requirement for irrigation was lower as the distance of irrigation pipes was further. And it seems to be needed more precise research on this theme, because crop yield and the dynamics of soil minerals in subsurface irrigation can vary with the depth and distance of irrigation pipes, dripper, water flow depending on the soil texture, and plant response to soil minerals.

Installed Spacing and Reponse Time Index of Heat Detection Devices (열감지장치의 응답시간지수와 경계구역)

  • 권오승;이복영;김동석
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.72-75
    • /
    • 1996
  • The objectives of this paper investigate the effect of installed spacing on the activation of spot type heat detection devices. The flow of hot gases under a ceiling resulting from the impingement of a fire plume activates heat detectors and sprinklers. Local temperature and velocity in this ceiling jet are usually expressed with the function of a ceiling height, the distance from a fire location and the heat release rate of fire. And detectors having different. RTI respond in different ways to the same temperature and velocity of ceiling jet. Thus great care should be taken to decide installed spacing of heat detection devices by considering above effects.

  • PDF

Novel Raman Fiber Laser and Fiber-Optic Sensors Using Multi-Channel Fiber Gratings

  • Han, Young-Geun;Kim, Sang-Hyuck;Lee, Sang-Bae;Kim, Chang-Seok;Kang, Jin-U.;Paek, Un-Chul;Chung, Young-Joo
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.97-101
    • /
    • 2003
  • The transmission characteristics of multi-channel long period fiber gratings (LPFGs) in terms of the physical parameters like the separation distance, grating length and number of gratings will be discussed. Their transmission characteristics such as channel spacing, number of channels, loss peak depth, and channel bandwidth can be easily controlled by physical parameters. Based on the experimental results, their applications to optical multiwavelength Raman lasers and optical sensors will be investigated. A multiwavelength Raman fiber ring laser with 9 WDM channels with 100 ㎓ spacing and 19 channels with 50 ㎓ spacing using tunable multi-channel LPFGs will be experimentally demonstrated. The fiber-optic sensing applications with high resolution and sensitivity based on multi-channel LPFGs will be also presented.

Effect of baffle parameters on heat transfer in shell-and-tube heat exchangers (원통다관형 열교환기에서 배플인자가 열전달에 미치는 영향)

  • Lee, Sang-Cheon;Jo, Yeong-U;Nam, Sang-Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.1
    • /
    • pp.185-194
    • /
    • 1997
  • An experimental study has been performed on the effect of baffle parameters on shell -side heat transfer in a conventional shell-and-tube heat exchanger. The baffle spacing distance and the number of baffle were varied to investigate the behavior of unequal baffle spacing correction factor which is appeared in the Bell Delaware method for prediction of the shell-side heat transfer coefficient. It was obvious that heat duties obtained from the experiment significantly deviated from those calculated by the conventional Bell-Delaware method. A new correlation of the unequal baffle spacing correction factor was developed. It was shown that the new correlation improves the accuracy of the Bell-Delaware method considerably. This result may induce the use of the Bell-Delaware method in developing a computer software for design of shell-and-tube heat exchangers.

Optimum Design of High Speed Transmission SMF Link Using DCF (분산보상 광섬유를 이용한 초고속 단일모드 광섬유 전송링크의 최적 설계 연구)

  • 김용범
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.9B
    • /
    • pp.1518-1526
    • /
    • 2000
  • This paper proposes an optical transmission link design method based on an optimum compensation scheme using dispersion compensating fiber (DCF), so that high-speed long-distance optical transmission would be possible over the conventional standard single mode fiber (SMF) link. The proposed design method provides the maximized transmission distances according to the signal speeds, where the amplifier spacing and repeater spacing are optimized wit respect to self-phase modulation(SPM) due to fiber nonlinearity and amplified spontaneous emission (ASE) noises caused by optical amplifies. It is also shown that there exists an optimum input signal power range balancing the effects of ASE noise and SPM for the given amplifier spacing and repeater spacing.

  • PDF

Influence of Electrode Spacing on Methane Production in Microbial Electrolysis Cell Fed with Sewage Sludge (하수슬러지를 기질로 하는 미생물전기분해전지에서 전극간 거리가 메탄 생산에 미치는 영향)

  • Im, Seongwon;Ahn, Yongtae;Chung, Jae-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.12
    • /
    • pp.682-688
    • /
    • 2015
  • Effect of electrode spacing on the performance of microbial electrolysis cells(MECs) for treating sewage sludge was investigated through lab scale experiment. The reactors were equipped with two pairs of electrodes that have a different electrode spacing (16, 32 mm). Shorter electrode distance improved the overall performance of MEC system. With the 16 mm of electrode distance, the current density was $3.04{\sim}3.74A/m^3$ and methane production was $0.616{\sim}0.804Nm^3/m^3$, which were higher than those obtained with 32 mm of electrode spacing ($1.50{\sim}1.82A/m^3$, $0.529{\sim}0.664Nm^3/m^3$). The COD removal was in the range of 34~40%, and the VSS reduction ranged 32~38%. As the current production increased, VSS reduction and methane production were increased possibly due to the improved bioelectrochemical performance of the system. Methane production was more affected by current density than VSS reduction. These results imply that the reducing the electrode spacing can enhance the methane production and recovery from sewage sludge with the decreased internal resistance, however, it was not able to improve VSS reduction of sewage sludge.