• Title/Summary/Keyword: Source of loss

Search Result 1,216, Processing Time 0.037 seconds

The Model Development of Coupled Thermo-Electromagnetic Analysis in Three-phase Induction Motors by using Heat loss Mapping Method (3상 유도 전동기에서의 열손실 사상법을 이용한 열전달-전자기장 연계 수치 해석 모델 개발)

  • Kim, Dong-Hee;Kim, Chi-Won;Jung, Hye-Mi;Lee, Ju;Um, Suk-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.788-789
    • /
    • 2011
  • A comprehensive thermo-electromagnetic model has been developed to estimate temperature and electromagnetic distribution in an three-phase induction motor under steady state operation. Electromagnetic modeling enables us to predict thermal dissipation rates by eddy-current loss and copper loss in induction motors. Non-uniform temperature distributions are investigated to account for the strong effect of local temperature build-up on the motor performance and expected life-span. For more accurate thermal modeling purpose, Heat loss mapping method, which is matched up with electromagnetic losses and volumetric heat source, is developed and performed analysis. Heat loss mapping method can be greatly used as a design or diagnostic tool for three-phase induction motors with complex structural electromagnetic fields.

  • PDF

Flyback switching loss analysis by capacitor charge and energy conservation

  • Jin, ChengHao;Chung, Bong-Geun;Moon, SangCheol;Koo, Gwan-Bon
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.179-180
    • /
    • 2015
  • The task of measuring losses becomes more challenging with ever increasing efficiencies and operating frequencies in power electronics applications. Generally, the process of traditional switching loss calculation in flyback converter is very complicated. MOSFET drain-source voltage and current waveforms are needed to calculate switching loss. However, as we know in switched capacitor converter, switching loss can be easily calculated by charge and energy conservation law with known initial and final capacitor voltages. In this paper, the same method is applied to fly-back converter switching loss analysis to simplify calculation procedure.

  • PDF

Environmental Noise Prediction of Power Plants (발전소 환경소음 예측)

  • 조대승;유병호
    • Journal of KSNVE
    • /
    • v.7 no.4
    • /
    • pp.621-629
    • /
    • 1997
  • For computer aided design and costruction of low noisy power plants, indoor and outdoor noise prediction program has been developed. The program utilizes the predefined data of noise sources and building materials and has the faculty to estimate the source level using the empirical formula in case of the measured data not being available. In the noise prediction, the mutual noise propagation between indoor and outdoor sites are considered. The outdoor noise source in the calculation of geometric divergence effects is modelled as the omni-directional finite line or planar source according to the source geometry and the receiving points. Outdoor noise prediction is carried out to consider the diffraction effect due to plant structures as well as the attenuation effect due to atmospheric absorption and soft ground. The results of indoor and outdoor noise prediction for a recently constructed diesel engine power plant show good agreement with the measured.

  • PDF

Ship Radiated Noise Measurement Methods and Accuracy Analysis (선박 방사소음의 측정방법 및 정확도 해석)

  • Lee, Phil-Ho;Yoon, Jong-Rak
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.6 s.99
    • /
    • pp.738-748
    • /
    • 2005
  • The ship radiated noise level fluctuates by the difference of interference and reverberation according to measurement methods and environmental conditions. These phenomena cause error of the source level estimation even in the same environment conditions. This paper describes a quantitative analysis and a reduction method for an error value to the source level estimation in spatial and temporal interference environment. The design criteria of the radiated noise measurement array composed of omni-directional hydrophones and the source level accuracy in the deep water range are given. The source level accuracy in the shallow water range is also derived based on the statistical model of the multiple reflection paths. The results are verified using the water tank experiment and the sea trial.

Design and Measurement of Dissipative Silencers for Noise Reduction of Large Maritime Gas Turbine Engines (해상용 대형 가스터빈의 소음 저감을 위한 흡음형 소음기의 설계 및 성능 측정)

  • Baek, Seonghyeon;Lee, Kanghee;Gwon, Daehun;Lee, Iljae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.367-371
    • /
    • 2014
  • Based on ISO 7235, an experimental setup to measure the acoustic performance of splitter type dissipative silencers are fabricated. The length of each duct, sound source, microphone locations, modal filter, and anechoic termination are considered in the design of this setup. The modal filter is a particularly important factor because it affects the limit of measurement, which is also determined by the amount of flanking transmission of sound generated by the sound source to microphones. The effects of absorptive materials, media which covers the materials, and the number of splitters on the noise reduction of the sample silencers are experimentally investigated. The insertions loss of silencers with media and higher number of splitters increases, especially at higher frequencies.

  • PDF

Improved Circuit Model for Simulating IGBT Switching Transients in VSCs

  • Haleem, Naushath Mohamed;Rajapakse, Athula D.;Gole, Aniruddha M.
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1901-1911
    • /
    • 2018
  • This study presents a circuit model for simulating the switching transients of insulated-gate bipolar transistors (IGBTs) with inductive load switching. The modeling approach used in this study considers the behavior of IGBTs and freewheeling diodes during the transient process and ignores the complex semiconductor physics-based relationships and parameters. The proposed circuit model can accurately simulate the switching behavior due to the detailed consideration of device-circuit interactions and the nonlinear nature of model parameters, such as internal capacitances. The developed model is incorporated in an IGBT loss calculation module of an electromagnetic transient simulation program to enable the estimation of switching losses in voltage source converters embedded in large power systems.

Design and Implementation of a Single Bias FET Source Mixer

  • Kim, Hwoa-Yuol;Lee, Sung-Woo;Lim, Kyung-Taek;Cho, Hong-Goo
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.1
    • /
    • pp.22-28
    • /
    • 1998
  • A new type of FET source mixer with a single bias voltage has been presented. It is designed to operate at Vds=0 [V] with only one positive supply voltage, which makes mixer circuits simple. The proposed mixer has shown improved stability and less sensitivity to both bias and LO power compared with conventional active mixers. It also shows lower conversion loss than that of diode mixers. The minimum conversion loss measured at RF frequency of 5.6㎓ is 0.6㏈ for a LO frequency of 5.8㎓.

  • PDF

High-Speed EMU : Basic Research on the Noise Reduction (동력분산형 고속철도 : 소음저감기술의 기초 연구)

  • Hong, Yun-H.;Kim, Jeung-T.;Kim, Jung-Soo;Kim, Seock-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1441-1447
    • /
    • 2008
  • This research studies the effects of community noise around railway, noise from the inside/outside noise of the High-Speed EMU. First study part of this year is research of the noise source. The modeling methodology for prediction of noise level including the frequency property, velocity dependence, sound pressure of noise source is investigate. Second part is research on the sound transmission loss. An exclusive program which could analyze the sound transmission loss of the floor, the sides(mirror), insulator in High-Speed EMU has to be developed. Third part is research on the train inside/outside and Prediction for community Noise. In order to predict the noise when the High-Speed EMU is traveling at the outside and along tunnels, the result of the research can be derived by evaluating the effect of the noise on the upper/middle parts of the carriage and on the railroad way round about with using the program.

  • PDF

Modeling of non-isothermal CO2 particle leaked from pressurized source: I. Behavior of single bubble

  • Chang, Daejun;Han, Sang Heon;Yang, Kyung-Won
    • Ocean Systems Engineering
    • /
    • v.2 no.1
    • /
    • pp.17-31
    • /
    • 2012
  • This study investigated the behavior of a non-isothermal $CO_2$ bubble formed through a leak process from a high-pressure source in a deep sea. Isenthalpic interpretation was employed to predict the state of the bubble just after the leak. Three modes of mass loss from the rising bubble were demonstrated: dissolution induced by mass transfer, condensation by heat transfer and phase separation by pressure decrease. A graphical interpretation of the last mode was provided in the pressure-enthalpy diagram. A threshold pressure (17.12 bar) was identified below which the last mode was no longer present. The second mode was as effective as the first for a bubble formed in deep water, leading to faster mass loss. To the contrary, only the first mode was active for a bubble formed in a shallow region. The third mode was insignificant for all cases.

Source Identification of PM2.5 at the Tokchok Island on the Yellow Sea (황해상 덕적도 PM2.5오염원의 확인)

  • 윤용석;배귀남;김동술;황인조;이승복;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.4
    • /
    • pp.317-325
    • /
    • 2002
  • An air pollution monitoring station has been operated at Tokchok Island since April 1999 to characterize the background atmosphere in the vicinity of the Yellow Sea. In this study, eight chemical species in PM$_{2.5}$ and three gaseous species were analyzed. A total of 53 samples were collected for the analysis of PM$_{2.5}$ and gaseous species from April, 1999 to April, 2001. The overall mean mass concentration of PM$_{2.5}$ was 20.8 $\mu\textrm{g}$/㎥ and the eight soluble ionic species accounted for about 46.8% of PM$_{2.5}$ mass. Approximately 80% of samples appeared to experience the chloride loss effect. Air pollutant sources of PM$_{2.5}$ measured at Tokchok Island were qualitatively identified by the principal component analysis. It was found that five principal components are secondary aerosol, soil, incineration, phase change of nitrate, and ocean.and ocean.