Uncertainty in the Calibration of Coaxal Thermal Noise Sources using a Noise Figure Measuring Equipment

  • Kang, Tae-Weon;Kim, Jeong-Hwan;Park, Jeong-Il
    • Journal of electromagnetic engineering and science
    • /
    • 제4권2호
    • /
    • pp.79-86
    • /
    • 2004
  • In this paper, the uncertainty in the calibration of coaxial thermal noise sources using a noise figure measuring (NFM) equipment is evaluated. Contributions to the uncertainty such as the calibration uncertainty of the standard noise source, mismatch, measurement of adapter efficiency, ambient temperature variation, and repeatability are evaluated in the frequency range of 10 MHz to 18 ㎓. Results show that the expanded uncertainty(k=2) is 0.23 ㏈ for the noise sources of 5 ㏈ and 15 ㏈ ENR, and 0.27 ㏈ for those of 21 ㏈.

측정용 전리함에 따른 고 선량율 근접치료용 방사성 선원의 겉보기 활성도의 정확도 비교 분석 (Analysis of Accuracy of Apparent Activity According to Calibration Method for High Dose Rate Brachytherapy Source)

  • 허현도;최진호;최상현;김성훈;김우철;김헌정;이레나;김금배;홍성언;신동오
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.305-312
    • /
    • 2008
  • 본 연구에서는 측정 방법이 다른 두 전리함을 이용하여 고선량율 근접치료용 방사성 선원의 겉보기 활성도를 측정하여 선원의 활성도 정확성 및 두 장비간의 정확도를 비교 분석하였다. 국내 5개 의료기관을 선정하여 공기 중 기준거리에서 겉보기 활성도를 측정하고 동일한 선원에 대하여 측정 방법이 다른 두 팬톰을 동시에 측정하여 측정방법에 따른 상호 오차와 측정용 전리함의 정확도를 평가하였다. 우물형 전리함과 Jig 팬톰의 상대 오차는 각각 -2.1%~0.2%, -2.8%~-1.0%로 나타났다. 동일한 방사성선원에 대하여 두 교정 장비간의 정확도 평가는 최대 상대오차 1%로 나타났다. 선원의 세기 검증 시 측정 방법에 따른 의존도는 없었다. 고 선량율 근접방사선치료에 사용되는 방사성 선원의 세기의 변화는 환자의 종양 및 인접장기에 미치는 영향이 매우 크므로 방사성 선원의 세기 오차는 환자치료의 최적화에 심각한 영향을 미칠 수 있다. 그러므로 새로운 선원 교체 시 뿐만 아니라 주기적인 선원 점검이 요구된다.

  • PDF

Noise PDF Analysis of Nonlinear Image Sensor Model with Application: Iterative Radiometric Calibration Method

  • Myung, Hwan-Chun;Youn, Heong-Sik
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 International Symposium on Remote Sensing
    • /
    • pp.247-250
    • /
    • 2008
  • The paper presents the advanced radiometric calibration method, called the lRCM (Iterative Radiometric Calibration Method), in order to avoid an operational constraint (solar source) for calibration. The IRCM assumes that an optical instrument is equipped with a filter assembly which consists of same band filters with different transmission ratios. Given all the noise sources (including the artificial one caused by the filters) of an image sensor, the noncentral ${\chi}^2$ distribution of the output result is induced by the approach of a noise PDF (Power Density Function). Finally, the radiometric calibration problem is transformed into equating two independent relations for the image sensor gains through the specified distribution.

  • PDF

밀도검층 검출기 보정에 관한 기초 연구 (An Experimental Study on Density Tool Calibration)

  • 김영화;김기주;임헌태;김지훈;공남영
    • 지구물리
    • /
    • 제7권4호
    • /
    • pp.237-245
    • /
    • 2004
  • 밀도 검층에 미치는 각 영향 요소들을 검토하고 현행 사용자 보정의 한계와 문제점 파악을 위한 기초 실험이 수행되었다. 간접 보정 방법에 속하는 현행 사용자 보정을 물과 알루미늄 블럭을 사용하는 사용자 보정과 반감기 식을 이용한 사용자 보정으로 구분하여 분석하였으며 국내에서 처음 시도된 지구물리모형 시추공을 이용한 직접 보정 방법의 적용 결과와 비교, 분석되었고 이로부터 기존의 사용자 보정의 한계와 가능성을 평가할 수 있었다.

  • PDF

기준점에서의 물 흡수선량을 이용한 Ir-192 선원의 공기커마 세기 계산을 위한 알고리즘 개발 (The Development of Air-kerma Strength Calculation Algorithm in Terms of the Absorbed Dose to Water for HDR Ir-192 Source)

  • 허현도;김우철;노준규;이석;이상훈;조삼주;신동오;최진호;권수일;김성훈
    • 한국의학물리학회지:의학물리
    • /
    • 제17권4호
    • /
    • pp.232-237
    • /
    • 2006
  • 본 연구의 목적은 Ir-192 선원의 검교정을 겉보기 방사능(apparent activity)을 이용하지 않고 물속 기준점에서 흡수선량을 측정함으로써 공기커마 세기(air-kerma strength, Sk)를 계산하고자 알고리즘을 개발하였다. 연구를 위하여 근접치료용 다목적 팬톰(multi purpose brachytherapy Phantom, MPBP)을 제작하였다. 물 흡수선량 측정은 고선량률 근접치료기(micro-Selectron, Nucletron, Netherlands)에 장착된 Ir-192 선원(Mallinckrodt Medical B.V., Netherlands)을 대상으로 측정하였다. 물 흡수선량은 몬테칼로 계산방법으로 계산된 이온전리함(TM30013, PTW, Germany)의 물 흡수선량 교정인자($N_{D.W.Q}$)를 이용하여 결정하였다. 물 흡수선량은 한 개의 선원에 대하여 4 cm에서 7 cm까지 측정하였다. 측정된 값은 전산화 치료계획 장치에서(plato BPS, ver 13.2, Nucletron, Netherlands) 계산된 값과 비교하였다. 공기커마 세기(Sk)는 기준점 5 cm되는 곳에서 3개의 Ir 선원에 대하여 구하였다. 계산된 공기커마 세기는 선원제조사에서 제공된 값과 비교하였다. 몬테칼로 계산방법으로 계산된 이온전리함의 물 흡수선량 교정인자는 5.28 cGy/nC이었다. 한 개 선원에서 측정한 물 흡수선량 값은 -2.16%에서 -0.84%까지 상대오차를 나타내었다. 공기커마 세기는 제조사에서 제공된 값과 비교하여 -0.6%에서 +1.8% 제조사 권고치 ${\pm}5%$ 이내로 잘 일치하였다. 본 연구에서 개발한 알고리즘은 기준점에서의 물 흡수선량을 정확히 결정함으로써 선원의 공기커마 세기를 구할 수 있었다. 이러한 물 흡수선량을 통한 Ir-192 선원의 검교정 방법들은 미국의학물리학회(AAPM) 보고서 TG-43에서 권고한 흡수선량 계산 알고리즘에 바로 적용할 수 있는 것으로 사료된다.

  • PDF

Development of an energy and efficiency calibration method for stilbene scintillators

  • Kim, Chanho;Kim, Jaehyo;Hong, Wooseong;Yeom, Jung-Yeol;Kim, Geehyun
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3833-3840
    • /
    • 2022
  • A method for calibrating the energy scale and detection efficiency of stilbene scintillators is presented herein. This method can be used to quantitatively analyze the Compton continuum of gamma-ray spectra obtained using such scintillators. First, channel-energy calibration was conducted by fitting a semi-empirical equation for the Compton continuum to the acquired energy spectrum and a new method to evaluate the intrinsic detection efficiency, called intrinsic Compton efficiency, of stilbene scintillators was proposed. The validity of this method was verified by changing experimental conditions such as the number of sources being measured simultaneously and the detector-source distance. According to the energy calibration, the standard error for the estimated Compton edge position was ±1.56 keV. The comparison of the intrinsic Compton efficiencies calculated from the single- and two-source spectra showed that the mean absolute difference and the mean absolute percentage difference are 0.031 %p and 0.557%, respectively, demonstrating reasonable accuracy of this method. The feasibility of the method was confirmed for an energy range of 0.5-1.5 MeV, showing that stilbene scintillators can be used to quantitatively analyze gamma rays in mixed-radiation fields.

어레이 센서 위치보정 알고리즘을 적용한 광대역 다중 신호원 빔형성에서 새로운 신호원의 도래방향 추정 (DOA Estimation of New Appearing Source in Wideband Multisource Beamforming with Array Sensor Position Calibration Algorithm)

  • 심재광;강성현;윤원식
    • 한국음향학회지
    • /
    • 제18권3호
    • /
    • pp.49-54
    • /
    • 1999
  • 본 논문에서는 어레이 센서 위치보정 알고리즘을 적용한 광대역 다중 신호원 빔형성 및 추적에 있어서 새로운 신호원이 검출되었을 때 초기 도래방향을 추정하는 새로운 방법을 제안한다. 초기 도래방향 추정에 있어 빔패턴 형성식을 이용함으로써 추정오차를 추적범위 내에 있도록 한다. 제안한 방법은 추정 도래방향 각의 해상도를 조정할 수 있으므로 주엽폭 특성이 다른 다양한 빔형성기에 적용할 수 있다. 모의 시험을 통하여 양호한 신호원 검출 및 추적성능을 확인하였다.

  • PDF

수중 내 베타선 모니터링 센서 개발을 위한 기초연구 (Feasibility Study on Development of an Underwater Beta-ray Monitoring Sensor)

  • 박혜민;주관식
    • 센서학회지
    • /
    • 제25권5호
    • /
    • pp.333-336
    • /
    • 2016
  • In this study, a beta monitoring sensor was developed as a part of basic research for quantitative beta monitoring underwater, and its performance was evaluated using a calibration source. A beta detection sensor was manufactured by using SiPM(silicon photomultiplier) and $CaF_2$:Eu, YAG:Ce, YAP:Ce scintillator. A large-area light guide was introduced to improve beta-ray detection efficiency. As calibration sources, the Beta source $^{90}Sr$, which is the main fission product of a nuclear accident, and the gamma source $^{137}Cs$ are used. In the performance evaluation, it is confirmed that scintillator $CaF_2:Eu$ gives the highest beta-ray detection response. Compared to gamma ray, beta-ray detection responsivity and detection efficiency are verified. Therefore, this study is expected to contribute to basic research in the development of an underwater beta-ray monitoring system.

CHARACTERISTICS OF THE KAERI NEUTRON REFERENCE FIELDS FOR THE CALIBRATION OF NEUTRON MONITORING INSTRUMENTS

  • Kim, Bong-Hwan;Kim, Jang-Lyul;Chang, Si-Young;Cho, Gyu-Seong
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.243-248
    • /
    • 2001
  • Neutron reference fields of Korea Atomic Energy Research Institute (KAERI) for calibrating neutron measuring devices to be used in radiation workplace monitoring consist of two kinds of neutron spectra, the direct and the scattered neutron fields, which are produced by using radionuclide neutron sources, 252Cf and 241AmBe sources. Necessary parameters for calibration such as the anisotropy factor of each neutron source and the room-scattered fraction of some neutron surveymeters in the KAERI calibration facility were determined by calculation or measurement. Spectral measurement of scattered neutron fields were performed at each reference calibration point using a Bonner Multi-sphere Spectrometer (BMS) and the dosimetric quantities for calibration also estimated from the neutron energy spectra which were unfolded using the BUNKI code.

  • PDF

실리콘 웨이퍼 휨형상 측정 정밀도 향상을 위한 시스템변수 보정법 (System calibration method for Silicon wafer warpage measurement)

  • 김병창
    • 한국기계가공학회지
    • /
    • 제13권6호
    • /
    • pp.139-144
    • /
    • 2014
  • As a result of a mismatch of the residual stress between both sides of the silicon wafer, which warps and distorts during the patterning process. The accuracy of the warpage measurement is related to the calibration. A CCD camera was used for the calibration. Performing optimization of the error function constructed with phase values measured at each pixel on the CCD camera, the coordinates of each light source can be precisely determined. Measurement results after calibration was performed to determine the warpage of the silicon wafer demonstrate that the maximum discrepancy is $5.6{\mu}m$ with a standard deviation of $1.5{\mu}m$ in comparison with the test results obtained by using a Form TalySurf instrument.