• 제목/요약/키워드: Sound reduction performance

검색결과 212건 처리시간 0.032초

건식벽체 차음성능 분석 및 평가 (Analysis and evaluation of sound reduction performance of drywall system)

  • 백승경;장천상;고종철;이종인;김현배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.727-732
    • /
    • 2009
  • The objective of this study is to analyze and evaluate design factors relating to sound reduction performance in dry wall system. The main contents of this study are as follows. 1) Analysis and pre-evaluation of sound reduction performance of drywall system ; The sound reduction performance was pre-evaluated by INSUL simulation and these results of analyzing walls were analyzed by screening DOE(design of experiment) for selecting major factors that dominant influence the sound reduction performance. These main factors relating to sound reduction performance can be used for development of 1st grade sound reduction performance drywall system. 2) Design and evaluation of 1st grade sound reduction performance drywall system; The evaluation test of the sound reduction performance gave vaues higher than 1st grade (Rw+C=64). When campared with existing dry wall system, respectivelly, the new system shows performance higher than 8 dB.

  • PDF

건식 이중바닥구조의 중량충격음 저감성능 평가 (Evaluation for The Heavy-weight Impact Sound Reduction Performance of Dry Double-Floor System)

  • 연준오;김경우;최현중;양관섭;김경호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.280-285
    • /
    • 2012
  • The 1st assessment (performance test) was applied to assure the floor impact sound performance for developing the dry double- floor with the change of rubber hardness of the upper panel's support and the ceiling structure of the sub-floor. Depends on the change of the rubber hardness in substructure, the heavy-weight sound impact value is improved up to 3 dB, and the light-weight sound impact value is moved up to 21 dB, comparing with the bare-slab. Also, the improved value for the floor impact sound conjugating with the sub-floor's ceiling was 5dB. Based on this result, the 2nd assessment (performance test) was made the state that the rubber hardness of the sub-floor support was ranged between 50 and 70 for considering the stability of walking patients. In addition to this process, the assessment was carried out with a variety of ceiling structure applied to the dry doublefloor structure with the air flow system on the sub-floor's ceiling. The result for the 2nd assessment proved that TYPE-11 had the better sound reduction performance in the heavy-weight impact sound test than other types, and also for the light-weight impact sound TYPE-11 had the 29 dB sound reduction performance overall. Henceforth, based on the result the research for the sound reduction performance from the floor impact sound shall be ongoing process as well as the development of a double-dry floor and a sound reduction ceiling to suitable on the field.

  • PDF

압전재료에 따른 지능패널의 전달소음저감성능 (Transmitted sound reduction performance of smart panels with different piezoelectric materials through piezo-damping)

  • 이중근;김재환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.127-132
    • /
    • 2001
  • In this paper, transmitted sound reduction performance of smart panels is studied according to different piezoelectric materials with piezoelectric shunt damping. Peizo-damping is implemented by using a newly proposed tuning method. This method is based on electrical impedance model and maximizing the dissipated energy at the shunt circuit. By measuring the electrical impedance at the piezoelectric patch bonded on a structure, an equivalent electrical model is constructed near the system resonance frequency. After shunting elements are connected to the equivalent circuit, the shunt parameters are optimally searched based on the criterion of maximizing the dissipated energy at the shunt circuit. Transmitted sound reduction performance is compared according to different piezoelectric materials with peizo-damping. Two piezoelectric materials are selected: PZT-5 and QuickPack IDE actuator. When resonant shunt circuit is considered, the use of PZT-5 exhibited the good sound reduction performance.

  • PDF

건식이중바닥구조의 중량충격음에 대한 실험적 평가 - 지지구조 및 천장구조 구성에 따른 영향 - (Experiment Evaluation for the Heavy-weight Impact Sound of Dry Double-floor System - Effect of Rubber Hardness and Ceiling Structure -)

  • 연준오;김경우;최현중;양관섭;김경호
    • 한국소음진동공학회논문집
    • /
    • 제23권1호
    • /
    • pp.34-40
    • /
    • 2013
  • The 1st assessment(performance test) was applied to assure the floor impact sound performance for developing the dry double-floor with the change of rubber hardness of the upper panel's support and the ceiling structure of the sub-floor. Depends on the change of the rubber hardness in sub-structure, the heavy-weight sound impact value is improved up to 3 dB, and the light-weight sound impact value is moved up to 21 dB, comparing with the bare-slab. Also, the improved value for the floor impact sound conjugating with the sub-floor's ceiling was 5 dB. Based on this result, the 2nd assessment(performance test) was made the state that the rubber hardness of the sub-floor support was ranged between 50 and 70 for considering the stability of walking patients. In addition to this process, the assessment was carried out with a variety of ceiling structure applied to the dry double-floor structure with the air flow system on the sub-floor's ceiling. The result for the 2nd assessment proved that TYPEII-3 had the better sound reduction performance in the heavy-weight impact sound test than other types, and also for the light-weight impact sound TYPEII-3 had the 29 dB sound reduction performance overall. Henceforth, based on the result the research for the sound reduction performance from the floor impact sound shall be ongoing process as well as the development of a double-dry floor and a sound reduction ceiling to suitable on the field.

관 경사출구에 부착된 플랜지가 소음방사에 미치는 영향 (The effect of the flange attached to the inclined exit of tube on the noise radiation)

  • 백두산;양윤상;이동훈;이영균
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.134-137
    • /
    • 2014
  • The noise reduction performance of a passive facility is dependent on the its length or volume. In other words, this means that the larger the size of passive facility is, the better the noise reduction performance is. The sound directivity control has been proposed as an alternative for the noise reduction without a passive facility. The purpose of this study is to investigate the correlation between the flange attached to inclined exit of the tube and sound directivity when the sound radiates from the tube to the outside. As a result, the sound radiated from flanged tube had weak sound directivity in the wide angle. Also as the flange was bigger, the sound pressure level was lower in the behind the flange.

  • PDF

바닥충격음 저감방안에 따른 성능평가 (Evaluation of Floor Impact Sound Performance according to the Reduction Methods)

  • 김경우;최경석;최현중;양관섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.131-136
    • /
    • 2004
  • Impact sounds, such as those created by footsteps, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The character and level of impact noise generated depends on the object striking the floor, on the basic structure of the floor, and on the floor covering. This study base on the evaluate of isolation performance of impact sound according to the impact noise reduction methods. Reduction methods consist of four ways. First way is increase thickness of bare floor and other ways are using the soft coverings on the floor and ceiling assembles. Last way is make floating floor with shock absorbing materials.

  • PDF

바닥충격음 저감방안에 따른 성능평가 (Evaluation of Floor Impact Sound Performance according to the Reduction Methods)

  • 최경석;최현중;양관섭;김경우
    • 한국소음진동공학회논문집
    • /
    • 제14권9호
    • /
    • pp.811-818
    • /
    • 2004
  • Impact sounds, such as those created by footsteps, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The character and level of impact noise generated depends on the object striking the floor, on the basic structure of the floor, and on the floor covering. This study base on the evaluate of isolation performance of impact sound according to the impact noise reduction methods. Reduction methods consist of four ways. First way is increase thickness of bare floor and other ways are using the soft coverings on the floor and ceiling assembles. Last way is make floating floor with shock absorbing materials.

실증 적용을 통한 외부 전동블라인드의 성능 평가 및 개선 방안 (Evaluation and improvement of external electric blinds through field application)

  • 강민우;이희동;오양기
    • 한국음향학회지
    • /
    • 제42권3호
    • /
    • pp.181-188
    • /
    • 2023
  • 일반적인 거주 공간에서 창호는 외부소음에 직접적으로 노출된다. 외부소음을 가장 효과적으로 저감할 수 있는 방법은 내부가 아닌 외부에서 바로 소음을 차단하는 방법이다. 태양 빛 차단을 위한 외부 블라인드는 다양하게 제품화되어 있지만, 우리나라에서는 아직 적극적으로 활용되지 못하고 있다. 앞선 연구에서는 차광용으로 제작된 외부 전동블라인드의 차음성능을 검증하기 위해 공인 실험실에서 실험하였다. 그 결과 일반창호 저감 성능 대비 6 dBA의 추가 차음성능을 검증하였다. 이 연구에서는 외부 전동블라인드의 차음성능을 실제 거주 공간 창호에 실증 적용하여 저감성능을 확인하고자 하였으며, 효과적인 소음저감 성능 추가확보를 위해 개선방안을 모색하고자 하였다. 실험결과, 외부 전동블라인드 자체의 저감 성능은 기본 창호 대비 1 dBA ~ 3 dBA 수준으로 미미했다. 하지만 블라인드 슬릿 사이의 틈새 충진을 통해 2 dBA 수준의 추가 저감성능을 확인하였다.

단일수치 평가방법에 따른 방음벽의 흡음성능 고찰 (Sound Absorption Performance of Noise Barrier According to Single Number Rating Methods)

  • 김용희;이성찬
    • 한국소음진동공학회논문집
    • /
    • 제27권2호
    • /
    • pp.243-250
    • /
    • 2017
  • In this study, single number rating methods of sound absorption coefficients are discussed. After that the sound absorption performance of noise barriers which are classified by Korea Standard are analyzed according to several standards. The existing rating methods such as NRC (noise reduction coefficient), SAA (sound absorption average) or ${\alpha}_w$ (weighted sound absorption coefficient) from ASTM C423, KS F 3505 and ISO 11654 are introduced. The sound absorption performance of noise barrier is evaluated to compare NRC and ${\alpha}_w$ value. When the value is over 0.6 there are large variance between NRC and ${\alpha}_w$ value. As results, it is needed to unify single number rating methods of sound absorption coefficients for Korean standards on sound absorbing materials.

하부틈새 크기에 따른 도어의 음향감쇠계수 분석 (Sound Reduction Index of Interior Door by Aperture Sizes at Door's Bottom)

  • 김명준
    • 한국소음진동공학회논문집
    • /
    • 제20권9호
    • /
    • pp.834-840
    • /
    • 2010
  • The Sound reduction indices(SRIs) of interior door with 13 different size apertures are measured in acoustic chamber. Also, as a theoretical approach, the SRIs are estimated using Gomperts' theory. In this study, the aperture of interior door is focused on the lower part of door leaf which is well known as a main cause to deteriorate the sound insulation performance of door. The results show that the SRI of door strongly depends on the aperture width and the dip in the measured sound reduction index curve by the resonance effect within aperture is observed at high-frequency. On the whole, the values calculated by theory are in good agreement with the measured values including the position of resonance dip. The average difference between the measured and the calculated values is 0.9 dB for 13 doors with different size aperture in terms of the weighted SRI.