Proceedings of the Korean Society for Noise and Vibration Engineering Conference (한국소음진동공학회:학술대회논문집)
- 2014.10a
- /
- Pages.134-137
- /
- 2014
- /
- 1598-2548(pISSN)
The effect of the flange attached to the inclined exit of tube on the noise radiation
관 경사출구에 부착된 플랜지가 소음방사에 미치는 영향
Abstract
The noise reduction performance of a passive facility is dependent on the its length or volume. In other words, this means that the larger the size of passive facility is, the better the noise reduction performance is. The sound directivity control has been proposed as an alternative for the noise reduction without a passive facility. The purpose of this study is to investigate the correlation between the flange attached to inclined exit of the tube and sound directivity when the sound radiates from the tube to the outside. As a result, the sound radiated from flanged tube had weak sound directivity in the wide angle. Also as the flange was bigger, the sound pressure level was lower in the behind the flange.