• 제목/요약/키워드: Sound noise control

검색결과 441건 처리시간 0.026초

가청화를 이용한 돔형 체조연습장의 음향 성능평가에 관한 연구 (A Study on Valuation of Acoustic Performance about Dome-typed Gymnastics Training Floor utilizing Auralization)

  • 윤재현;주덕훈;정은정;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.132-136
    • /
    • 2007
  • In case of indoor gymnastics training floor, in view of its characteristics, since it is simultaneously required the related smooth communication between the coach and the player, also the acoustic performance regarding to the Clearness of Music, besides the sport activity, the consideration about the acoustic character has entered the stage as an indispensable element. On such viewpoint, on the object of the recently built dome-typed gymnastics training floor, after making the optimized acoustic design with the remodeling through acoustic simulation, by means of measurement and valuation on human's psychological(sensual) degree utilizing Auralization that enables to experience the virtual sound field at the stage of design, this thesis has attempted to survey of the acoustic satisfaction degree and its reaction about the gymnastics training floor. As the result of investigation about the research on the space of object, it could be known that the valuation regarding to the acoustic performance of 'After-Improvement' was distinctly more refined than that of 'Before-Improvement'. It is now considering that such result of the study can be utilized as the useful data which enables to improve the retrenchment effect of the construction cost as well as the acoustic capability, by means of the prediction control on the acoustic problem from the stage of design, for the occasion when the similar indoor sport gymnasium is planning to build for the near future.

  • PDF

진동작업 종사 근로자의 진동노출 실태에 관한 연구 (Research on the actual vibration exposure of workers engaging in vibration induced works)

  • 김갑배;정은교
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.178-185
    • /
    • 2012
  • In Korea, researches on the exposure assessment of the hand-transmitted vibration started from the mid-90, however, they were performed in the limited industries such as auto-assembly plants and the evaluation of the vibration was mostly conducted by ISO 5349(1986). Therefore, it was necessary to assess hand-transmitted vibration levels of workplace such as ship building/repairing industry or mining industry where occupational injuries are largely occurred and to evaluate the vibration levels using revised ISO 5349(2001). The SVAN 949 Four Channels Sound & Vibration Analyser was used for the measurement. The workers using a chain saw were exposed to $1.7{\sim}2.8m/s^2$ of daily vibration level. Workers using a rock drill in a coal mining were exposed to the highest vibration acceleration among workers and the levels were $7.1{\sim}10.8m/s^2$. Vibration levels of grinders were different according to the types of grinders. The hand-transmitted vibration of 3 types of grinders were measured and the levels were $3.3{\sim}11.1m/s^2$. Workers using a impact wrench were exposed to $1.5{\sim}1.6m/s^2$ of vibration. Out of 20 kinds of machines, only 4 tools provided the information of vibration acceleration on the instructions. In addition, the current condition of workplaces to control vibration was not much different from the past because there are no vibration exposure limit.

  • PDF

초임계 보일러 재열기 급수 공급배관의 과도 음향진동 진단 및 회피설계 (Mechanism Diagnosis and Avoidance Design on Transient Acoustic Vibration of Reheater Water Supply Piping in Supercritical Boiler)

  • 김연환;배용채;김재원;이두영;허해용
    • 한국소음진동공학회논문집
    • /
    • 제23권5호
    • /
    • pp.385-393
    • /
    • 2013
  • In this paper, the mechanism identification and the avoidance measures on the phenomena of transient acoustic vibration amplified at the water-supply piping system to regulate the steam temperature of the boiler reheater in 500MW class supercritical power plant are presented. The pressure pulsation waves induced by the impeller passing of two feed-water pumps with five blades are coincident with the local acoustic modes of boiler reheater water-supply piping system. There are the phenomena amplified at the peaks of 5X, 10X, 15X and 20X in spectrums of piping vibration, sound pressure, and the feed-water's pressure pulsation waves. The shut-off device is installed in the piping system for the interception of pressure pulsation waves transmitted from two feed-water pumps and the modified design change of the piping layout is applied for the acoustic resonance avoidance. The acoustic natural frequencies are separated from the harmonics of pressure pulsation waves induced by the pump impellers passing through the design change of the span length. The acoustic vibration is gone by resonance avoidance measures. As a result, more than 20 dBA reduction is achieved from 100 dBA to 80 dBA.

일부 진동작업 종사 근로자의 진동노출 수준 평가 (Assessment on the Actual Vibration Exposure of Workers Engaging in Vibration Induced Works)

  • 김갑배;정은교;유기호;장재길
    • 한국소음진동공학회논문집
    • /
    • 제22권10호
    • /
    • pp.940-948
    • /
    • 2012
  • In Korea, researches on the exposure assessment of the hand-transmitted vibration started from the mid-90, however, they were performed in the limited industries such as auto-assembly plants and the evaluation of the vibration was mostly conducted by ISO 5349(1986). Therefore, it was necessary to assess hand-transmitted vibration levels of workplace such as ship building/repairing industry or mining industry where occupational injuries are largely occurred and to evaluate the vibration levels using revised ISO 5349(2001). The SVAN 948 Four Channels Sound & Vibration Analyser was used for the measurement. The workers using a chain saw were exposed to 1.7~2.8 $m/s^2$ of daily vibration level. Workers using a rock drill in a coal mining were exposed to the highest vibration acceleration among workers and the levels were 7.1~10.8 $m/s^2$. Vibration levels of grinders were different according to the types of grinders. The hand-transmitted vibration of 3 types of grinders were measured and the levels were 3.3~11.1 $m/s^2$. Workers using a impact wrench were exposed to 1.5~1.6 $m/s^2$ of vibration. Out of 20 kinds of machines, only 4 tools provided the information of vibration acceleration on the instructions. In addition, the current condition of workplace to control vibration was not much different from the past because there are no vibration exposure limit.

발포알루미늄의 제조공정 및 흡음특성 (Acoustic Abosrption Characteristic and Fabrication process of Foamed Aluminum)

  • 허보영;안효준;전성환;최대철;김상렬;허윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.396-402
    • /
    • 2000
  • Porous structures of aluminum foam have been studied. The apparent foam shape, foam hight, density, pore size, shape, and their distributions in various section areas of the experimental samples have been investigated. The sample have been cast into metallic mold, using aluminum foam prepared from a precursor based on pure Al ingot mixed with various amount of 1-2wt% increasing viscosity and foam agent materials. The process provides for flexibility in design of foam structures via relatively easy control over the amount of hydrogen evolution and the drainage processes which occur during foam formation. This is facilitated by manupulating parameters such as the foaming agent, thermal histories during solidification and mix melt viscosities. The acoustical performance of the panel made with the foamed aluminum is considerably improved; its absorption coefficient shows NRC 0.6-0.8. It has been found that the Al foam is very preferable for the compactness of the thermal system.

  • PDF

심한 소음환경에서 언어장애인 음성 인식률 향상을 위한 단어선정 방법 및 장치 개선에 관한 연구 (A Study on Word Selection Method and Device Improvement for Improving Speech Recognition Rate of Speech-Language-impaired in Severe Noise Environment)

  • 양기웅;이형근
    • 한국정보통신학회논문지
    • /
    • 제23권5호
    • /
    • pp.555-567
    • /
    • 2019
  • 언어장애인, 언어 사용이 불편한 분들의 경우 조금의 잡음 환경에도 음성인식률이 저하되어 사회 생활시 어려움을 겪게 된다. 언어 사용 시 불편함을 장치로 개선시킴과 동시에, 언어 장애인의 발음 특성을 고려하여 단어 선정 시 자체 개선한 단어 선정 방법을 사용하여 280개 단어를 선정하였다. 실험에 사용된 MEMS 개발 장치는 재질, 유도선 종류, 길이, 방향을 고려하여 제작되었으며 잘못된 발음으로 인한 음성과 심한 소음에서 음성 인식률 향상을 위하여 개발된 MEMS 장치와 개발된 단어 선정 방법을 사용하여 개선시켰다. 개선 방법으론 새로운 단어 선정 방법과 mems 장치를 개선하여 진행하였으며 결과를 포함하였다.

Tractor 동력취출장치(P.T.O.)의 동력전달구조에 관한 연구 (A Study on the Characteristic of Power Transmission by the Power-take-off(P.T.O.) of farm Tractor)

  • 송현갑
    • 한국농공학회지
    • /
    • 제15권3호
    • /
    • pp.3089-3095
    • /
    • 1973
  • The power transmission to the traction devices may be very important for the tractor performance and therefore this system has been studied very much in the past. On the other hand, the PTO(Power-take-off) has been considered as an accessary on the tractor with a few work for its power transmission. Because of increased use of PTO operation in various kind of farming operations in recent years, the function of PTO may become such important as the traction facilities. In this study, the power transmission characteristics of PTO drive was analyzed theoretically and some experimental work was done to study on it. The results of the study are as follows: 1) The most stable condition of PTO work was obtained when the intersection angle of the two curves for driving and driven torques was about ${\pi}/2$. 2) To obtain the most stable operation it is better to use both the speed control and the full control together. 3) Six steps differential gear may not be enough to use the PTO power smoothly. It is thought that the three steps differential gear on the shaft of PTO may be necessary additionally for a smooth operation. 4) When the traction facilities and the PTO are used at the same time, the torque of crank shaft becomes Tt + Tp, and the high efficiency and good stability of word will be obtained with the small variation of driving speed. 5) When the tractor was operated with 75% of the rated horse power and 70% of maximum speed, the best thermal efficiency could be obtained. 6) The most dangerous sound for human occured at the rated speed of PTO and tus it may be necessary to control the dangerous noise.

  • PDF

스펙트럼 변조를 이용한 청각정보의 촉감재현 가능성 연구 (Feasibility Study on Audio-Tactile Display via Spectral Modulation)

  • 곽현구;김희국;정주노;강대임;박연규;구민모
    • 한국정밀공학회지
    • /
    • 제28권5호
    • /
    • pp.638-647
    • /
    • 2011
  • Various approaches directly using vibrations of speakers have been suggested to effectively display the aural information such as the music to the hearing-impaired or the deaf. However, in these approaches, the human can't sense the frequency information over the maximum perceivable vibro-tactile frequency (around 1kHz). Therefore, in this study, an approach via spectral modulation of compressing the high frequency audio information into perceivable vibro-tactile frequency domain and outputting the modulated signals through the designated speakers is proposed. Then it is shown, through simulations of using Short-Time Fourier Transform (STFT) with Hanning windows and through preliminary experiments of using the vibro-tactile display testbed which is built and interfaced with a notebook PC, that the modulated signal of a natural sound composing sounds of a frog, a bird, and a water stream could produce the noise-free signal suitable enough for vibro-tactile speakers without causing Significant interfering disturbances, Lastly, for three different combinations of information provided to the subject, that is, i) with only video image, ii) with video image along with the modulated vibro-tactile stimuli as proposed in this study to the forearm of the subject, and iii) with video image along with full audio information, the effects to the human sense of reality and his emotion to given audio-video clips including various sounds and images are investigated and compared. It is shown from results of those experiments that the proposed method of providing modulated vibro-tactile stimuli along with the video images to the human has very high feasibility to transmit pseudo-aural sense to the human.

성악도들의 음성관리 및 성대화상술상의 문제점과 발성에 대한 음향분석학적 특징 (Problems of Strobovideolarygoscopic Findings and Usual Voice Management of Vocal Major Students, and Acoustic Characteristics of Singing Voice)

  • 진성민;김대영;반재호;이상혁;송윤경;권기환;이경철;이용배
    • 대한후두음성언어의학회지
    • /
    • 제10권1호
    • /
    • pp.43-49
    • /
    • 1999
  • Objectives : The purpose of this study was to systematically analyze and compare e acoustic sound structure of vocal major student's singing voice. Materials and Methods : The nineteen vocal major students were the subject group and healthy nineteen females were the control group for this study. The subject group was taken a strobovideolaryngoscopy by the use of flexible nasopharyngoscopy. And acoustic analysis was taken between two groups. Additionally the inquiry on usual voice problems and management was performed by thirty-six vocal major students. Results : The subject group presents many functional voice disorder findings such as AP contraction(44%), phase difference(36%) tremor(25%), posterior gap(17%), hyperadduction of vestibular fold(6%), and anterior gap(3%) on strobovideolaryngoscopy. And the vocal major students did reveal an enhanced number of high frequency harmonic partials when singing compared to the control group in the narrow band spectrum study. But there was no significant difference in jitter, shimmer and noise to harmonic ratio in both groups. Almost all vocal major students present a lot of voice problems in singing such as loss of high note(17%), loss of quiet voice(17%), effortful and tired voice(36%) etc on inquiry. And they always effort to prevent vocal dysfunction by the use of various type of method such as voice rest(28%), hydration(28%), gargling with salt(11%) etc. Conclusions : The vocal major students always take care of maintaining a good voice condition, but a lot of vocal major students revealed abnormal strobovideolaryngoscopic findings and they are absent in the conception of systemic and scientific voice management. Therefore, the young singers need a good voice training and voice therapy Program under the good ralationship of laryngologist and voice training teacher.

  • PDF

에어로빅스가 청각유발전위에 미치는 영향 (The Effects of an Aerobics on the Auditory Evoked Potential)

  • 박상남;김영활;김병원
    • 대한임상검사과학회지
    • /
    • 제38권3호
    • /
    • pp.224-230
    • /
    • 2006
  • Up to now, there have been rare clinical studies on leaders and aerobics athletes. To get the useful data for protecting from auditory disorder, we selected 15 female aerobics leaders (experimental group) and 15 females (control group) unexperienced in aerobics and a without neurological and octolaryngological disorder. The average age was $34.87{\pm}8.80$ (experimental group) and $34.07{\pm}8.45$ (control group) years, and the average career of an aerobics leader (experimental group) was $8.33{\pm}4.73$ years. We measured the auditory evoked potential (AEP) of the two groups treated with 70, 75 and 85 dB intensity from January 2006 to May 2006 and analyzed the absolute latency (AL) and interpeak latency (IPL) by the SPSS/pc+ 12.0 program. In the comparison of the AL between the experimental group and the control group according to intensity, both ears treated with 70 and 75 dB had a significant difference (p<0.05) in the I, III, V wave and in the I, V wave respectively, and the experimental group treated with 85 dB showed a difference in the I, III, V wave (left ear) and in the I wave (right ear) respectively. The IPL of the two groups treated with various intensities had no prolongation. In the comparison of the AL between the experimental group and the control group according to ages, the experimental group in their 20s treated with 70 dB showed a significant difference (p<0.05) in the V wave (left ear) and in the I, III, V wave (right ear), and the experimental group in their 20s treated with 75 dB in the I, III wave (left ear) and in I, III, V wave (right ear), and experimental group in their 20s treated with 85 dB in the V wave (left ear) and in the III, V wave (right ear). The experimental group in their 30s treated with 70 dB had a significant difference (p<0.05) only in the V wave (right ear). Only in the IPL of subjects in their 20s treated with 85 dB, III-V and I-V of both ears was extended. In the comparison of the AL and IPL according to career, there was no significant difference between the two groups. From this results, we concluded that the lower sound intensity (70 dB) showed a more significant difference in the experimental group than the control group. We concluded that the leader of aerobics exposed to louder sounds than normal people are affected by auditory neurological and octolaryngological disorders. So we think that the leaders of aerobics need to control the noise level for protecting themselves against a disease.

  • PDF