• 제목/요약/키워드: Sound noise control

검색결과 441건 처리시간 0.037초

음향 인텐시티를 이용한 하드디스크 드라이브의 소음원 파악 및 음향파워 제어 (Noise Source Identification and Acoustic Radiation Power Reduction of Hard Disk Drive Using Sound Intensity)

  • 강성우;한윤식;황태연;손영;구자춘
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1540-1548
    • /
    • 2000
  • Sound intensity techniques and ODS(Operational Deflection Shape) techniques are applied to identify the acoustic noise source of a hard disk drive and its control system. The sound intensity is used to visualize the noise source locations, and the ODS information to visualize the vibration pattern and to obtain the dynamic characteristics of the noise sources. The measurement systems are customized to accurately measure the sound intensity and ODS distributions of HDD system in space domains as well as frequency domains. The measurement systems for the sound absorption and transmission loss of materials are also used to support the background data for the efficient noise control. Using the visual information of source locations and its dynamic characteristics, the partial noise barrier structure and optimum absorption are designed and its controlled sound power level is proved to be under 3.1 Bel(Idle)/3.3Bel (Seek) which is the lowest level in the disk drive industry.

  • PDF

순시 인텐시티 측정 기법의 개발 및 응용 (Development and Application of Measuring Method of Instantaneous Intensity)

  • 이장우;김영종;안병하;이운섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.560-563
    • /
    • 1997
  • Sound intensity method is well known as a visualization technique of sound field and sound propagation in noise control. Sound intensity is a vector quantity that describes the magnitude and the direction of net flow of acoustic energy at a given position. The current measuring method is expensive and difficult to identify the noise source exactly. In this paper, we have studied the noise source identification and the characteristics of noise source of rotary compressor for air conditioner using complex sound intensity method. The new method for instantaneous sound intensity is also proposed and it is useful for transient state and steady state. The criteria of these states select auto correlation coefficient. The advantage, simplicity and economic attribution of this method are verified by analyzing the characteristics of noise source with instantaneous sound intensity compared to mean sound intensity.

  • PDF

관 경사출구에 부착된 플랜지가 소음방사에 미치는 영향 (The effect of the flange attached to the inclined exit of tube on the noise radiation)

  • 백두산;양윤상;이동훈;이영균
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.134-137
    • /
    • 2014
  • The noise reduction performance of a passive facility is dependent on the its length or volume. In other words, this means that the larger the size of passive facility is, the better the noise reduction performance is. The sound directivity control has been proposed as an alternative for the noise reduction without a passive facility. The purpose of this study is to investigate the correlation between the flange attached to inclined exit of the tube and sound directivity when the sound radiates from the tube to the outside. As a result, the sound radiated from flanged tube had weak sound directivity in the wide angle. Also as the flange was bigger, the sound pressure level was lower in the behind the flange.

  • PDF

Two Dimensional Complex Sound Intensity를 이용한 압축기 소음원 규명에 관한 연구 (A Study on Noise Identification of Compressor Based on Two Dimensional Complex Sound Intensity)

  • 안병하;김영수
    • 한국정밀공학회지
    • /
    • 제17권1호
    • /
    • pp.83-92
    • /
    • 2000
  • Sound intensity method is well known as a visualization technique of sound field or sound propagation in noise control. Sound intensity or energy flux is a vector quantity which describes the amount and the direction of net flow of acoustic energy at a given position. Especially two dimensional sound intensity method is very useful in evaluating periodic characteristics and acoustic propagation mode of noise source. In this paper, we have studied the noise source Identification, acoustic sound field analysis, and characteristics of noise source of rotary compressor and scroll compressor for air conditioner using complex sound intensity method. Also we proposed a now method of time domain analysis which is used in evaluating of position of noise source in rotary and scroll compressor in this paper This paper presents the advantage, simplicity and economical efficiency of this method by analysing the characteristics of noise source with two dimensional complex sound intensity simultaneously.

  • PDF

잔향실을 이용한 콘트롤 밸브 소음 예측 방법 (Prediction Method of Control Valve Noise)

  • 이용봉;윤병로;박경암;이두희;유선학
    • 한국음향학회지
    • /
    • 제21권8호
    • /
    • pp.703-707
    • /
    • 2002
  • 새로운 콘트롤 밸브 소음 예측 방법을 제안하고 밸브 및 배관으로 이루어진 시스템에 적용하여 그 가능성을 할인하였다. 기존의 소음 예측 방법은 무향실을 이용하는 기존의 예측방법보다 일반 산업체에서 시험 시설을 설치하기가 용이한 장점이 있다. 측정된 음향파워를 이용하여 소음예측식을 결정하고 상대유량계수 0.11인 경우 소음예측식에 따라 유량 및 차압의 변화에 따른 음향파워레벨을 평가하였고 그 결과가 측정값과 잘 일치함을 확인하였다. 제안된 밸브소음 예측기법은 콘트롤밸브의 소음특성을 나타내는 지표로서 사용할 수 있다.

다수의 음원을 사용한 공간의 소리 제어 방법론 (Spatial Manipulation of Sound using Multiple Sources)

  • 최정우;김양한;박영진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.620-628
    • /
    • 2005
  • Spatial control of sound is essential to deliver better sound to the listener's position in space. As it can be experienced in many listening environments, the quality of sound can not be manifested over every position in a hall. This motivates us to control sound in a region we select. The primary focus of the developed method has to do with the brightness and contrast of acoustic image in space. In particular, the acoustic brightness control seeks a way to increase loudness of sound over a chosen area, and the contrast control aims to enhance loudness difference between two neighboring regions. This enables us to make two different kinds of zone - the zone of quiet and the zone of loud sound - at the same time. The other perspective of this study is on the direction of sound. It is shown that we can control the direction of perceived sound source by focusing acoustic energy in wavenumber domain. To begin with, the proposed approaches are formulated for pure-tone case. Then the control methods are extended to a more general case, where the excitation signal has broadband spectrum. In order to control the broadband signal in time domain, an inverse filter design problem is defined and solved in frequency domain. Numerical and experimental results obtained in various conditions certainly validate that the acoustic brightness, acoustic contrast, direction of wave front can be manipulated for some finite region in space and time.

  • PDF

조용한 공간 만들기 (방법론과 예) (Design and control of quiet zone (principle and example))

  • 김양한;윤두병;남경욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.565-570
    • /
    • 2000
  • In order to make a quiet zone, one can consider methods to generate a secondary sound field that cancels a primary sound field. Active noise control (ANC) is one of the kinds. This paper mainly deals with the issues on determining the optimal positions of control sources and sensors for making a desired quiet zone. The issues address the reason why the positions are important, how the positions are optimized, and what the measure on the optimal positions is in an uncertain sound field. It is also shown that a power control is applicable to a specific uncertain sound field. In addition, this paper shows that a control material method, which passively changes a boundary condition, is essentially found to be on the same road of ANC.

  • PDF

LED 조명 발열의 순차 제어시스템 연구 (Temperature Control for LED lamps using RF Communication)

  • 최형식;신희영;오지윤;이상섭
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2012년도 전기공동학술대회 논문집
    • /
    • pp.130-132
    • /
    • 2012
  • In this paper, a temperature control for LED(Light Emitting Diode) lamp using a cooling fan is studied. An efficient temperature control scheme for the LED lamp using the fan wind at the lowest sound noise is studied. For the study, after measurement of the minimum sound noise of the fan and related temperature of the LED lamp through tests, experiments on temperature control of the LED lamp using the fan with various size of heat sinks was performed. To minimize the fan sound noise, optimal size of the heat sink was studied. Also, a teleoperting control of LED lamps using RF communication was studied.

  • PDF

흡음재 배치를 통한 닫힌 공간에서의 소음원 방사 파워 제어 (Radiation Power Control by Means of Absorptive Material Arrangement in an Enclosure)

  • 조성호;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.688-691
    • /
    • 2004
  • We have studied the possibility of global noise reduction by the sound power control through selection of distribution and impedance of absorptive materials. It is necessary to investigate the relation between the global sound energy in the field and the total sound power radiated by sources. In the previous work (1,2), the authors presented a useful design method to change boundary condition that can be useful to reduce noise in acoustically small enclosures. The possibility of total acoustic potential energy reduction by acoustic source power control is examined in an acoustically small cavity. Using acoustic energy balance equation, the relation between global noise control performance and absorptive material's arrangement/impedance is deduced. Numerical simulation is performed to interpret its physical meaning in terms of absorbent's distribution and impedance.

  • PDF

다채널 적응 알고리즘을 이용한 잔향 음장에서의 능동소음제어에 관한 연구 (Active Noise Control of Reverberant Sound Field Using the Multi-Channel Adaptive Algorithm)

  • 김홍섭;손동구;오재응
    • 한국자동차공학회논문집
    • /
    • 제3권6호
    • /
    • pp.23-29
    • /
    • 1995
  • In this study, Active noise controlis implemented with single channel and multi-channel adaptive algorithm in 3 dimensional reverberant enclosure sound. field, which occurrs in complicated acoustic mode. First, for the one case excited with the resonant frequency of an enclosure, a target of control and the other cases excited with band-pass filtered random noise(100~400Hz), it is implemented to control reducing interior noise of enclosure with single channel and realtime multi-channel adaptive algorithm for global noise reduction in enclosure.

  • PDF