• Title/Summary/Keyword: Sound noise control

Search Result 441, Processing Time 0.032 seconds

Temperature Control for LED Lamps Using RF Communication (RF통신을 이용한 LED 조명의 온도제어)

  • Choi, Hyeung-Sik;Shin, Hee-Young;Oh, Ji-Youn;Lee, Sang-Seop
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.10
    • /
    • pp.759-765
    • /
    • 2012
  • In this paper, a temperature control for LED (light emitting diode) lamp using a cooling fan is studied. An efficient temperature control scheme for the LED lamp using the fan wind at the lowest sound noise is studied. For the study, after measurement of the minimum sound noise of the fan and related temperature of the LED lamp through tests, experiments on temperature control of the LED lamp using the fan with various size of heat sinks was performed. To reduce the fan sound noise, a method of reducing the operation time with optimal size of the heat sink was studied. Also, a control of LED lamps using RF communication was studied.

Sound Field Controller Design Method based on Partial Model Matching on Frequency Domain

  • Kumon, Makoto;Eguchi, Kazuki;Mizumoto, Ikuro;Iwai, Zenta
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1398-1403
    • /
    • 2003
  • In this paper, a simple method to design an MIMO sound field control system was proposed. The control system was designed to achieve 1) noise attenuation and 2) sound equalization by utilizing feedback and feedforward controllers. The method was based on partial model matching on frequency domain which only required measured frequency response data, or impulse response data in order to tune parameters of the controller. The proposed method was applied to a normal office room and results of experiment showed effectiveness of the proposed method.

  • PDF

Active Control of Sound Fields from Vibrating Plates Using Piezoelectric and Viscoelastic Material (압전재료와 점탄성 재료를 이용한 평판 진동 음장의 능동제어)

  • Kang, Young-Kyu
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.12
    • /
    • pp.950-955
    • /
    • 2002
  • The coupled finite/boundary element method is used in numerical analysis for acoustic radiation from the vibration of rectangular composite plate which is simply supported. This analysis is validated using the Wallace equation for an isotropic plate. Active control of sound fields has been tarried out using 3 pairs of piezoelectric sensor/actuator and a pair of viscoelastic material by Passive constrained layer damping treatment. The results show that the optimal placement of piezoelectric sensor/actuator and VE patch is required to control the sound fields from a vibrating composite plate.

An interior noise characteristic analysis of Busan Metro Line 3 (부산 도시철도 3 호선 실내소음 특성분석)

  • Ahn, Chan-Woo;Hong, Do-Kwan;Han, Geun-Jo;Gang, Hyeon-Uk;Lee, Kwon-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.362-367
    • /
    • 2010
  • This paper deals with the correlation between the interior noise and the floor vibration of the train from rolling, impulse and friction in Busan Metro line 3. The correlation is verified by sound and vibration measurement causing friction between the railway and the wheel. If ANC(Active Noise Control) system can reduce 5 dB in below 500 Hz, the sound pressure level of the whole band pass can be reduced about 1.8-4.8 dB in squeal noise. Curve squeal noise is the intense high frequency tonal that can occur when a railway vehicle transverses a curve. The frequency range is from around 500 to almost 20,000 Hz, with noise levels up to about 15 dB in curve.

  • PDF

A Study on the Prediction & Transformation of Blasting Noise for Environmental Regulation Standard (발파소음의 예측기법과 환경규제 기준으로의 변환 연구)

  • 김남수;양형식
    • Explosives and Blasting
    • /
    • v.18 no.2
    • /
    • pp.14-22
    • /
    • 2000
  • The estimation of proper prediction method and the alteration of transformation method of environmental regulation standard were carried out by measuring blasting noise in construction field. The correlation of scaled distance with sound pressure level were better than with sound level, but it was proved to be difficult to control blasting noise because the correlation factor was too 1ow. three methods to transform sound pressure levee to sound level were examined. The method is the transformation by correlation equation of sound pressure level and sound level which are measured at the same time, and simplified transformation of A-weighting network corresponding to dominant frequency, and the transformation of sound pressure level by FFT. There were many errors to transform. The best effective method is the transformation using correlation equation of sound pressure level and sound level which are measured at the same time.

  • PDF

A Study on the Noise Reduction and Performance Improvement of the Hot Water Distributing System (시스템분배기 소음방지 및 성능개선방안 연구)

  • Kim, Yong-Ki;Lee, Tae-Won;Han, Tae-Su;Yoo, Sun-Hak
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1055-1060
    • /
    • 2009
  • Noise is one of the major environmental problems in human life. But hot water distributers with the flow rate control valve bring about often noise according to the heating control condition in residential buildings. The sound power level increased as the flow rate and pressure difference increased. And thus, experimental analyses for the flow rate control and the pressure difference control were carried out in this study to reduce the noise emitted from the flow rate control valve. As the results, the flow rate control method using a SMA(Shape Memory Alloy)-valve and the flow rate control system using a pressure difference sensor can be expected to control noise in the region of below 50 dB of sound power level.

  • PDF

Sound Intensity Control in a Duct Using Smart Foam (스마트 폼을 이용한 덕트 내의 음향 인텐시티 제어)

  • 한제헌;강연준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1132-1137
    • /
    • 2001
  • The smart foam that is first proposed by Fuller(2) is not applicable to active noise control in a duct having flow. Thus. this paper presents the ring-type smart foam as an alternative. The ring-type smart foam consists of polyurethane acoustic foam of lining shape and PVDF film embedded along the mid-surface of the foam lining. A feedforward adaptive filtered-x LMS controller is used to minimize the signal from the error microphone. To enlarge quiet sound region. two error microphones are used to update system modeling filter (SIMO method). Sound intensity control using the ring-type smart foam is also discussed

  • PDF

Characteristics of Machinery Noise (기계류의 소음 특성)

  • Kang, Dae-Joon;Gu, Jin-Hoi;Lee, Jae-Won;Kwon, Hyuk-Je;Park, Hyeong-Kyu;Kim, Ji-Yoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.904-908
    • /
    • 2008
  • As the various industrial production machinery has come into being by development of industrial technology, the productivity of the basic industrial production machinery has improved and the international competitiveness of the one of Korea has strengthened. However, at the same time, noise from various industrial production machinery disturbs the quiet environment. There are 35 kinds of the noise emission machinery defined in the noise and vibration control act according to the horse power and the number of machinery. These were classified in 1992 through investigation from 1990 to 1991, and the characteristic of the noise emission machinery may be different from the past one. So we need to investigate the characteristics of the noise emitted by machinery to control it rightly. Also we need to investigate the new noise emission machinery which has come into being recently. In this survey, we measured sound intensity of 32 noise emission machinery to calculate the sound power levels of those and investigated the characteristic of the sound power level of those according to the frequency. From the survey, we found that the forging machine, concrete pipe and pile making machine, sawing machine, etc. are the noisy machinery. And the automatic packing machine, sewing machine, centrifuge, etc. are the silent machinery. Also the generator, the concrete pipe and pile making machine, the printing machine, etc. emit the low frequency noise, and the molding machine, the stone cutter, the metal cutter, etc. emit the high frequency noise. Lastly, we intented to propose the proper guide line of classifying noise emission machinery.

  • PDF

Noise Control of Hard Disk Drive Using Structural Mobility Analysis (STRUCTURAL MOBILITY 분석을 통한 하드 디스크 드라이브의 소음제어(현장개발사례: SAMSUNG HDD 'SPINPOINT V20/P20 SERIES' ))

  • Kang, Seong-Woo;Han, Yun-Sik;Hwang, Tae-Yeon;Son, Young;Oh, Dong-Ho;Pham, Tho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.911-916
    • /
    • 2001
  • Structural acoustic modification method based on the structural mobility analysis is applied to reduce the structure-borne noise radiated from hard disk drive system. Sound intensity techniques and ODS(Operational Deflection Shape) techniques are also used in order to provide the structural acoustic information for the mobility modification. The sound intensity is for the acoustic visualization of the noise source locations, and the ODS is for the visualization of the vibration pattern and its dynamic characteristics of the noise sources. Using visualization information of sound and vibration, local structural input mobility is reduced in the frequency band of interest by designing asymmetrical wave-stringer structure in the wave-number domain as well as frequency domain. The overall sound pressure level is reduced by 4dB and its controlled sound power radiated from the disk drive is proved to under 2.8Bel in idle-spinning mode and 3.1 Bel in random-seeking mode, which are the lowest noise levels in the hard disk drive industry.

  • PDF

Active Noise Transmission Control Through a Panel Structure Using a Frequency Domain Identification Method (주파수 영역 모델 방법을 이용한 평판 구조물의 능동 소음전달 제어)

  • Kim, Yeung-Shik;Kim, In-Soo;Moon, Chan-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.9
    • /
    • pp.71-81
    • /
    • 2001
  • This paper analyzes the effectiveness of minimizing vibration and sound transmission on/through a thin rectangular plate by both feedback control and hybrid control which combines adaptive feedforward control with a feedback loop. An experimental system identification technique using the matrix-fractional curve-fitting of the frequency response data is introduced for complex shaped structures. This identification technique reduces the model order o the MIMO(Multi-Input Multi-Output) system which simplifies the practical implementation. The adaptive feedforward control uses a Multiple filtered-x LMS(Least Mean Square) algorithm and the feedback control uses a multivariable digital LQG(Linear Quadratic Gaussian) algorithm. Experimental results show that an effective reduction of sound transmission is achieved by the hybrid control scheme when both vibration and noise measurement signals are incorporated in the controller.

  • PDF