• Title/Summary/Keyword: Sound Speaker

검색결과 267건 처리시간 0.025초

고지향성 스피커를 위한 새로운 전력 증폭기 설계 (Design of High-efficiency Power Amplifier System for High-directional Speaker)

  • 김진영;김인동;문원규
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1215-1221
    • /
    • 2017
  • Parametric array transducers are used for highly directional speaker in an air environments. Piezoelectric micromachined ultrasonic transducers for parametric array transducers need DC-biased voltage driving signals in order to get high-directional quality-sound features. The existing power amplifier such as class A amplifiers has low efficiency and require large volume heatsinks. To overcome the above-mentioned disadvantages of the conventional amplifier, this paper proposes a new power amplifier system. The proposed power amplifier system ensures high linearity of output characteristic by utilizing the push-pull class B type amplifier. Furthermore, the proposed power amplifier system gets high efficiency because it contains the DC-DC converter-type power supply which can perform energy recovery and envelope tracking function. Also the paper suggests the detailed circuit topology. Its characteristics are verified by the detailed experimental results.

An Acoustic Study of English Non-Phoneme Schwa and the Korean Full Vowel /e/

  • Ahn, Soo-Woong
    • 음성과학
    • /
    • 제7권4호
    • /
    • pp.93-105
    • /
    • 2000
  • The English schwa sound has special characteristics which are distinct from other vowels. It is non-phonemic and occurs only in an unstressed syllable. Compared with the English schwa, the Korean /e/ is a full vowel which has phonemic contrast. This paper had three aims. One was to see whether there is any relationship between English full vowels and their reduced vowel schwas. Second was to see whether there is any possible target in the English schwa sounds which are derived from different full vowels. The third was to compare the English non-phoneme vowel schwa and the Korean full vowel /e/ in terms of articulatory positions and duration. The study results showed that there is no relationship between each of the full vowels and its schwa. The schwa tended to converge into a possible target which was F1 456 and F2 1560. The Korean vowel /e/ seemed to have its distinct position speaker-individual which is different from the neutral tongue position. The evidence that the Korean /e/ is a back vowel was supported by the Seoul dialect speaker. In duration, the English schwa was much shorter than the full vowels, but there was no significant difference in length between the Korean /e/ and other Korean vowels.

  • PDF

화자식별 기반의 AI 음성인식 서비스에 대한 사이버 위협 분석 (Cyber Threats Analysis of AI Voice Recognition-based Services with Automatic Speaker Verification)

  • 홍천호;조영호
    • 인터넷정보학회논문지
    • /
    • 제22권6호
    • /
    • pp.33-40
    • /
    • 2021
  • 음성인식(ASR: Automatic Speech Recognition)은 사람의 말소리를 음성 신호로 분석하고, 문자열로 자동 변화하여 이해하는 기술이다. 초기 음성인식 기술은 하나의 단어를 인식하는 것을 시작으로 두 개 이상의 단어로 구성된 문장을 인식하는 수준까지 진화하였다. 실시간 음성 대화에 있어 높은 인식률은 자연스러운 정보전달의 편리성을 극대화하여 그 적용 범위를 확장하고 있다. 반면에, 음성인식 기술의 활발한 적용에 따라 관련된 사이버 공격과 위협에 대한 우려 역시 증가하고 있다. 기존 연구를 살펴보면, 자동화자식별(ASV: Automatic Speaker Verification) 기법의 고안과 정확성 향상 등 기술 발전 자체에 관한 연구는 활발히 이루어지고 있으나, 실생활에 적용되고 있는 음성인식 서비스의 자동화자 식별 기술에 대한 사이버 공격 및 위협에 관한 분석연구는 다양하고 깊이 있게 수행되지 않고 있다. 본 연구에서는 자동화자 식별 기술을 갖춘 AI 음성인식 서비스를 대상으로 음성 주파수와 음성속도를 조작하여 음성인증을 우회하는 사이버 공격 모델을 제안하고, 상용 스마트폰의 자동화자 식별 체계를 대상으로 실제 실험을 통해 사이버 위협을 분석한다. 이를 통해 관련 사이버 위협의 심각성을 알리고 효과적인 대응 방안에 관한 연구 관심을 높이고자 한다.

대공간에서 전기음향 시스템에 따른 음향특성 변화 (The Effect of Sound Reinforcement Systems on the Acoustics of a Large-Span Spaces)

  • 정대업;주현경;최영지
    • 한국공간구조학회논문집
    • /
    • 제11권1호
    • /
    • pp.67-75
    • /
    • 2011
  • 본 연구는 컴퓨터 시뮬레이션을 이용하여 대공간에서 스피커 시스템의 변화에 따른 음장의 특성 변화를 검토하였다. 실의 음향특성변화는 실의 흡음력과 동시에 스피커 시스템의 지향성, 설치높이 및 개수를 조절하면서 예측 분석하였다. 연구 결과, 명료도 관련 지표인 D50 및 RASTI는 실의 흡음력 증가의 변화를 효과적으로 나타내는 것으로 분석되었다. 또 초기감쇠시간은 흡음력 증가에 따라 선형적으로 감소하였으나 저 고주파수대역에서는 오히려 증가하거나 변화를 보이지 않았으며, 잔향시간은 전체주파수대역에서 실의 흡음력 증가에 따라 감쇠하였으나 주파수대역별 결과에서는 오히려 증가하거나 비슷한 결과를 보였다. 이는 실의 음향특성이라기 보다는 감쇠구간의 비선형성에 기인한 것으로 판단된다. 스피커 시스템의 적용에 따른 분석결과, D50 및 RASTI는 실의 흡음력 증가에 크게 상관없이 거의 모든 시스템에서 'fair'이상으로 평가되었으며, 스피커의 설치위치가 높을수록 실의 흡음력 증가보다 스피커 지향특성 변화에 더 큰 영향을 받는 것으로 나타났다. 또한 스피커의 설치위치가 낮을수록 실의 잔향시간은 더 짧은 것으로 분석되었다. 시스템의 적용에 따른 잔향시간은 스피커 설치높이가 높을 경우 실의 흡음력 증가에 비례하여 감쇠하는 경향을 보였으나 스피커 설치높이가 낮은 경우 흡음력 증가에 의한 영향보다 시스템의 영향을 받는 것으로 나타났다.

대공간 스피커 배치 방식의 주관적 평가 연구 (Subjective Evaluation of Loudspeaker Layouts for a Large Dome)

  • 정대업;최영지;김정수
    • 한국공간구조학회논문집
    • /
    • 제10권3호
    • /
    • pp.75-80
    • /
    • 2010
  • 본 연구는 음향증폭시스템 중에서 청취자에게 가장 많은 영향을 미치는 스피커 시스템의 배치방식과 스피커 특성변화에 따른 청취자들의 주관적 반응을 명료도와 음향선호도 측면에서 측정하고 비교 분석함으로써 향후 대공간의 음향증폭시스템의 설계 시 활용할 수 있는 기초자료를 제공하고자 하였다. 연구 결과, 전체적으로 실의 흡음률이 결정적인 영향을 미치며, 천장의 흡음률이 높을수록 지각된 명료도는 높아지는 것으로 나타났다. 스피커가 낮게 설치된 경우에는 적용된 스피커의 개수가 많고 지향각이 좁은 스피커들이 사용된 경우의 명료도가 가장 높게 평가되었다. 그러나 전체적으로는 스피커가 천장 흡음면에 가까울수록, 그리고 60도 이하의 좁은 지향각을 갖는 스피커를 사용할 때 높은 명료도를 얻을 수 있으며, 본 연구의 검토범위에서는 8~10개 정도의 스피커가 적용되었을 때 주관적인 명료도 및 선호도가 가장 높게 평가되었다.

  • PDF

선박의 장비 공기소음이 수중소음에 미치는 영향 (Effect of Airborne Noise from Ship Machinery on Underwater Noise)

  • 김현실;김재승;김봉기;김상렬;이성현
    • 대한조선학회논문집
    • /
    • 제48권6호
    • /
    • pp.569-574
    • /
    • 2011
  • In research vessels or naval ships, airborne noise from machineries such as diesel engine is the major source of underwater noise at low speed. In this paper, effect of engine noise on underwater noise is studied by considering two paths; sound radiation from hull plate and direct airborne noise transmission through hull plate. SEA (Statistical energy analysis) is used to predict hull plate vibration induced by engine noise, where SEA model consists of only two subsystems; engine room air space and hull plate. The pressure level in water is calculated from sound radiation by plate. Engine noise transmission through hull plate is obtained by assuming plane wave propagation in air-limp plate-water system. Two effects are combined and compared to the measurement, where speaker is used as a source in engine room and sound pressure levels in engine room and water are measured. The hydrophone is located 1 m away from the hull plate. It is found below 1000 Hz, prediction overestimates underwater sound pressure level by 5 to 12 dB.

Tonal development and voice quality in the stops of Seoul Korean

  • Yu, Hye Jeong
    • 말소리와 음성과학
    • /
    • 제10권4호
    • /
    • pp.91-99
    • /
    • 2018
  • Korean stops are currently undergoing a tonogenetic sound change, as found in the Seoul dialect in which a merged VOT of aspirated and lax stops induces F0 to be the primary cue for distinguishing the two stops and the lax stops have lower F0 than the aspirated stops. In tonal languages, low tone is produced with a breathy voice. This study investigated whether there are changes in voice quality with respect to the tonogenetic sound change of Korean stops. Two age groups speaking the Seoul dialect participated in this study: five females and six males born in the 1940s and 1950s and nine females and eight males born in the 1980s and 1990s. This study replicated previous findings of VOT and F0 and further examined H1-H2, H1-A1, and H1-A2 to see how they correlate with the sound change. In the older and younger generations, H1-H2, H1-A1, and H1-A2 were significantly lower after the tense stops than after the aspirated and lax stops, but they were not significantly different after the aspirated and lax stops. However, the younger females exhibited some different results for H1-H2 and H1-A2 than the older generation. In the younger females, the H1-H2 mean was higher after the aspirated stops than it was after the lax stops at the vowel onset, and the H1-H2 difference increased at the vowel midpoint. Although there was an inter-speaker variation in the results of H1-H2 and H1-A1, analyses of individual speakers showed that the H1-H2 and H1-A1 were higher after the lax stops than after the aspirated stops in the younger female speakers. These results indicate that lax stops tend to be breathier than aspirated stops in the younger female speakers. They also indicate that changes in voice quality are on Korean stops with tonal sound change, but are still developing.

전력선통신 기반 음향 시스템 설계 및 특성 분석 (Sound System Design and Characteristic Analysis based on Power Line Communication)

  • 김관규;염경태;김관웅;김용갑
    • 한국콘텐츠학회논문지
    • /
    • 제8권6호
    • /
    • pp.1-7
    • /
    • 2008
  • 본 논문은 기존의 음향 시스템이 가지고 있는 시스템 구성의 어려움, 추가설치비용 증가, 비 친화적인 인테리어의 문제점을 해결하기 위한 연구이다. 기존 시스템의 문제점을 해결하기 위하여 전력선통신을 기반으로 새로운 음향 시스템을 설계하고 특성을 연구하였다. PLC 전용칩 INT5500CS을 사용하여 송신기와 수신기를 설계하였으며, 송신부에서 CD PLAYER로 음향 신호를 제공하고 수신부에 스피커를 연결하여 출력하는 음향 시스템을 구성하였다. 구성된 시스템의 특성분석을 위해 USBPre 외장사운드 카드와 PC기반의 음향 측정/분석 프로그램인 Smaart Live 5를 추가 구성하여 실험하였다. 실험 결과, Measurement 신호는 Reference 신호보다 $2{\sim}3$[dB]정도의 낮은 신호레벨을 보였으며, Latency는 16.69[ms]을 확인하였고, Coherency는 고 주파수대역에서 특성이 나빠졌음을 확인하였다. 반면에, Pink Noise 및 특정 주파수 1[kHz], Phase, Magnitude를 확인한 결과 90[%] 이상으로 정상적인 신호의 송수신이 이루어 졌음을 확인하였다. 이러한 결과, 본 고에서 설계한 시스템의 성능이 우수함을 밝혔고, 이를 통해 기존 오디오 신호 전송 시스템의 문제점을 해결하였다.

음파 소화기를 이용한 안전 스토브 시스템 개발 (Development of Safe Stove System using Sound Wave Fire Extinguisher)

  • 서윤원;이석재;박형주;김기남;최용래;황형준;한승한;심동하
    • 한국화재소방학회논문지
    • /
    • 제32권6호
    • /
    • pp.34-39
    • /
    • 2018
  • 본 논문에서는 최초로 음파 소화기를 이용한 자동 화재진압 기능을 가진 안전 스토브 아키텍처를 제안하고 개발하였다. 화재가 발생하면 화재 센서와 연동된 마이크로컨트롤러가 화재를 감지하고 음파 소화기를 구동하여 화재를 진압하는 구조를 가진다. 음파 소화기는 스피커와 콜리메이터로 구성되며, 오디오 증폭기를 포함하는 구동모듈에 의해 구동된다. 스토브를 둘러싸는 인클로저를 사용해 거리에 따른 음파의 확산을 막아 음파의 감쇠를 줄일 수 있었다. 이때, 사용된 음파의 주파수는 50 Hz이며, 음압은 소화기로 부터 0.5 m 거리에서 93 dBA로 측정되었다. 7 cc 및 14 cc의 가연성 액체에서 발생한 화염에 대해 진화에 소요되는 시간은 각각 최대 8 s와 15 s로, 각각 자연소화 시간의 24%와 42%에 해당한다. 제안된 안전 스토브는 기존 안전 스토브와 비교하여 무해하고 잔여물질이 남지 않기 때문에, 다양한 가전기기에 적용되어 원활한 초기 화재 진압 및 화재 확산 방지에 기여할 것으로 기대된다.

Design and Analysis of Experimental Anechoic Chamber for Localization

  • Kim, Keon-Wook
    • 한국음향학회지
    • /
    • 제31권4호
    • /
    • pp.225-234
    • /
    • 2012
  • The anechoic chamber is essential tool to measure the various acoustic parameters with high precision. The chamber provides the climate controlled indoor environments but requires the dedicated room at a great cost in order to isolate and absorb sound field. Provided the purpose of the chamber is specific to the experiments of sound localization, the performance requirements excluding free field can be alleviated for cost effective solution. This paper designs low cost and profile anechoic chamber based on acoustic pyramids and evaluates the performance specified by the Annex of ISO 3745. Data analysis is employed to measure the free and hemi-free field performance over five straight paths for working areas and four paths for non-working areas. The identical two measurement campaigns were conducted for free and hemi-free field chamber which is easily interchangeable by simple labor in this chamber design. In the working area with conventional speaker, the results of these analyses demonstrate that lab-designed anechoic chamber is in conformance with ISO 3745 for 250 Hz - 16 kHz one-third octave band at free field chamber and for 1 kHz - 16 kHz one-third octave band at hemi-free field chamber.