• 제목/요약/키워드: Sound Exposure Level

검색결과 75건 처리시간 0.037초

진동작업 종사 근로자의 진동노출 실태에 관한 연구 (Research on the actual vibration exposure of workers engaging in vibration induced works)

  • 김갑배;정은교
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.178-185
    • /
    • 2012
  • In Korea, researches on the exposure assessment of the hand-transmitted vibration started from the mid-90, however, they were performed in the limited industries such as auto-assembly plants and the evaluation of the vibration was mostly conducted by ISO 5349(1986). Therefore, it was necessary to assess hand-transmitted vibration levels of workplace such as ship building/repairing industry or mining industry where occupational injuries are largely occurred and to evaluate the vibration levels using revised ISO 5349(2001). The SVAN 949 Four Channels Sound & Vibration Analyser was used for the measurement. The workers using a chain saw were exposed to $1.7{\sim}2.8m/s^2$ of daily vibration level. Workers using a rock drill in a coal mining were exposed to the highest vibration acceleration among workers and the levels were $7.1{\sim}10.8m/s^2$. Vibration levels of grinders were different according to the types of grinders. The hand-transmitted vibration of 3 types of grinders were measured and the levels were $3.3{\sim}11.1m/s^2$. Workers using a impact wrench were exposed to $1.5{\sim}1.6m/s^2$ of vibration. Out of 20 kinds of machines, only 4 tools provided the information of vibration acceleration on the instructions. In addition, the current condition of workplaces to control vibration was not much different from the past because there are no vibration exposure limit.

  • PDF

일부 진동작업 종사 근로자의 진동노출 수준 평가 (Assessment on the Actual Vibration Exposure of Workers Engaging in Vibration Induced Works)

  • 김갑배;정은교;유기호;장재길
    • 한국소음진동공학회논문집
    • /
    • 제22권10호
    • /
    • pp.940-948
    • /
    • 2012
  • In Korea, researches on the exposure assessment of the hand-transmitted vibration started from the mid-90, however, they were performed in the limited industries such as auto-assembly plants and the evaluation of the vibration was mostly conducted by ISO 5349(1986). Therefore, it was necessary to assess hand-transmitted vibration levels of workplace such as ship building/repairing industry or mining industry where occupational injuries are largely occurred and to evaluate the vibration levels using revised ISO 5349(2001). The SVAN 948 Four Channels Sound & Vibration Analyser was used for the measurement. The workers using a chain saw were exposed to 1.7~2.8 $m/s^2$ of daily vibration level. Workers using a rock drill in a coal mining were exposed to the highest vibration acceleration among workers and the levels were 7.1~10.8 $m/s^2$. Vibration levels of grinders were different according to the types of grinders. The hand-transmitted vibration of 3 types of grinders were measured and the levels were 3.3~11.1 $m/s^2$. Workers using a impact wrench were exposed to 1.5~1.6 $m/s^2$ of vibration. Out of 20 kinds of machines, only 4 tools provided the information of vibration acceleration on the instructions. In addition, the current condition of workplace to control vibration was not much different from the past because there are no vibration exposure limit.

일 제조업체의 작업장 소음실태에 관한 연구 (A Study on Actual Condition of the Noise in a Factory)

  • 신수옥
    • 한국보건간호학회지
    • /
    • 제9권2호
    • /
    • pp.43-51
    • /
    • 1995
  • Many poeple has been engaged in industry is aware of the dangers from exposure to high intensity nose levels. The exposure to high intensity noise is encountered in a large number of situations. Laws governing the safety and health of employed people being to create a suitable working environment and eliminate unsafety practices and processes. Work areas should be designed and laid out so that they are satisfactory both from the environmental and safety points of view. In this connection safety also implies that noise is kept at a level which is not likety to cause hearing damage. This study was performed to measure the noise of press and assembly process in an automobile factory. and suggested the method of noise control. Consequently the effect ways of reducing level in working environment are as follows; 1. Changes to machines which would reduce noise generation. 2. Alteration of equipment to avoid impact in machinery and handing materials. 3. Enclosure of noisy machines or machine parts. 4. Mounting of attenuators on gas and air outlets as well as ventilation ducts. 5. Erection of sound absorbing screens. linings. and baffles in work areas. 6. The personal ear protectors can be chosen to protect the workers.

  • PDF

도로 교통소음의 전파특성 연구 - 인체에 미치는 영향에 대한 고찰 - (The propagation characteristics of road traffic noise - with respect to human response -)

  • 장호경
    • 한국의학물리학회지:의학물리
    • /
    • 제11권1호
    • /
    • pp.19-27
    • /
    • 2000
  • 본 연구에서는 평탄한 지면 위의 도로 교통소음의 전파특성을 해석하고자 점음원과 쌍극자음원을 모델로 사용하였으며, 연속 지표면 음향임피던스에 대한 초과감쇠를 실험으로 조사하였다 연구결과 수음점이 지표면 가까이 있을 때, 도로 교통소음의 전파특성은 소음 전파경로 상의 지표면 음향임피던스에 크게 영향을 받는 것을 확인하였다. 또한 진행 차량으로부터 측정한 등가에너지레벨의 거리별 감쇠값을 이용하여 등음압곡선을 해석하였다 그리고 도로 교통소음이 인체에 미치는 영향을 조사하고자 초저주파 소음에 대한 응답특성, 깊은 수면율과 잠을 깨는 비율에 대한 연속적인 교통소음의 .효과, 연령과 소음폭로등 다양한 변수에 대하여 청력손실과 청감민감도 변화 등을 고찰하였다 해석결과 과도한 소음은 일시적 청력손실의 원인이며, 폭로가 길어지거나 강력하면 영구적 청력손실의 원인이 될 수 있음을 확인하였다.

  • PDF

적응형 파라미터 알고리즘을 이용한 개별 소음원의 음향파워 예측 연구 (Parameter-setting-free algorithm to determine the individual sound power levels of noise sources)

  • 문성호
    • 한국도로학회논문집
    • /
    • 제20권3호
    • /
    • pp.59-64
    • /
    • 2018
  • PURPOSES : We propose a parameter-setting-free harmony-search (PSF-HS) algorithm to determine the individual sound power levels of noise sources in the cases of industrial or road noise environment. METHODS :In terms of using methods, we use PSF-HS algorithm because the optimization parameters cannot be fixed through finding the global minimum. RESULTS:We found that the main advantage of the PSF-HS heuristic algorithm is its ability to find the best global solution of individual sound power levels through a nonlinear complex function, even though the parameters of the original harmony-search (HS) algorithm are not fixed. In an industrial and road environment, high noise exposure is harmful, and can cause nonauditory effects that endanger worker and passenger safety. This study proposes the PSF-HS algorithm for determining the PWL of an individual machine (or vehicle), which is a useful technique for industrial (or road) engineers to identify the dominant noise source in the workplace (or road field testing case). CONCLUSIONS : This study focuses on providing an efficient method to determine sound power levels (PWLs) and the dominant noise source while multiple machines (or vehicles) are operating, for comparison with the results of previous research. This paper can extend the state-of-the-art in a heuristic search algorithm to determine the individual PWLs of machines as well as loud machines (or vehicles), based on the parameter-setting-free harmony-search (PSF-HS) algorithm. This algorithm can be applied into determining the dominant noise sources of several vehicles in the cases of road cross sections and congested housing complex.

고화질 TV Set의 음향 파워 레벨 측정 및 평가 어휘 선정에 관한 실험적 연구 - LCD·PDP TV Set를 중심으로 - (A Study on the Power Level Measurement and Evaluating Vocabulary of H.D. TV Sets -Focused on LCD·PDP Tv Sets-)

  • 이태강;박현구;이주엽;이재천;신종근;김희진;김선우
    • 한국소음진동공학회논문집
    • /
    • 제15권9호
    • /
    • pp.1092-1099
    • /
    • 2005
  • This experimental study deals with the characteristics of LCD or PDP TV set noise, which are differ form those of CRT TV set. These characteristics are most important for establishing the effective method to reduce noise level, searching for the appropriate exposure level and evaluation method of LCD or PDP TV set noise. This study adopt two measurement method to specify the power level of LCD or PDP TV set noise in anechoic room(ISO 3741) and reverberation room(ISO 3745) . Comparing with each results of the two method, the reverberation room method is more simple in measuring and calculating the power level. And the subjective response test are carried out to select the pair of appropriate adjectives to present the characteristics of LCD or PDP TV set noise. The pair of 17 adjectives are selected from the 168 adjectives which are used in presenting the sound and noise form literature.

국내소음지도 표준화를 위한 현황 평가 (Evaluation of Present Status for the Korean Noise Map Standardization)

  • 박인선;박상규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.517-520
    • /
    • 2005
  • Noise mapping covers the whole mapping process from the collection of raw data, storage and retrieval of the data for computation/modeling, to the presentation of information related to outdoor sound levels, sound exposure, noise effects or numbers of affected person. This presentation can be in either a graphical or numerical form. In Europe, the Directive 2002/49/EC of the European Parliament and of the Council relating to the assessment and management of environmental noise is now being implemented in the EU Member States. Here, The first maps for major areas are required by mid 2007, and action plans required one year later. These activities are repeated at five yearly intervals and all defined areas are incorporated in the following round of deadlines starting in 2012. The above are minimum requirements and some countries are expected to go further and faster. In this study, present status of domestic and international noise maps has been introduced to implemente the Korean noise map standard. This will help to get more convenient and, more fair result, and produce correct map at domestic level.

  • PDF

실험적으로 제작한 Videodensitometer의 디지털 영상처리와 임상적 적용에 관한 연구 (DIGITAL IMAGE PROCESSING AND CLINICAL APPLICATION OF VIDEODENSITOMETER)

  • 박관수;이상래
    • 치과방사선
    • /
    • 제22권2호
    • /
    • pp.273-282
    • /
    • 1992
  • The purpose of this study was to propose the utility which was evaluated the digital image processing and clinical application of the videodensitomery. The experiments were performed with IBM-PC/16bit-AT compatible, video camera(CCdtr55, Sony Co., Japan), an color monitor(MultiSync 3D, NEC, Japan) providing the resolution of 512×480 and 64 levels of gray. Sylvia Image Capture Board for the ADC(analog to digital converter) was used, composed of digitized image from digital signal and the radiographic density was measured by 256 level of gray. The periapical radiograph(Ektaspeed EP-21, Kodak Co., U. S. A) which was radiographed dried human mandible by exposure condition of 70 kVp and 48 impulses, was used for primary X-ray detector. And them evaluated for digitzed image by low and high pass filtering, correlations between aluminum equivalent values and the thickness of aluminum step wedge, aluminum equivalent values of sound enamel, dentin, and alveolar bone, the range of diffuse density for gray level ranging from 0 to 255. The obtained results were as follows: 1. The edge between aluminum steps of digitized image were somewhat blurred by low pass filtering, but edge enhancement could be resulted by high pass filtering. Expecially, edge enhancement between distal root of lower left 2nd molar and alveolar lamina dura was observed. 2. The correlation between aluminum equivalent values and the thickness of aluminum step wedge was intimated, yielding the coefficient of correlation r=0.9997(p<0.00l), the regression line was described by Y=0.9699X+0.456, and coefficient of variation amounting to 1.5%. 3. The aluminum equivalent values of sound enamel, dentin, and alvolar bone were 15.41㎜, 12.48㎜, 10.35㎜, respectively. 4. The range of diffuse density for gray level ranging from 0 to 255 was wider enough than that of photodenstiometer to be within the range of 1-4.9.

  • PDF

PC방(게임방)에서 헤드셋을 착용한 중•고등학생의 소음 노출수준 (Noise Exposure Levels for the Middle and the High School Students using Headsets in the PC Rooms)

  • 신재우;김현욱
    • 한국산업보건학회지
    • /
    • 제15권2호
    • /
    • pp.135-143
    • /
    • 2005
  • This study was conducted to measure the exposure levels to noise for the middle and the high school students who worn headsets in the PC rooms. The noise levels from the headsets were measured with noise dosimeters, and the statistical relationships between the utilization pattern, user's views on the PC rooms and it's environment were analyzed for the selected PC rooms in the Ahnshan area. The results were as follows; 1. No significant difference was found in the number of uses and average time spent per day by education level and by sex of the users(p>0.05). 2. No statistical significant difference was found between the contents selected by education level of the users (p>0.05). The male participants overwhelmingly enjoyed the PC games (98.3 %) while females selected for listening music (75.0 %) with significant difference(P<0.05), followed by browsing internet and PC communications (70.0 %), PC game (66.7 %) and chatting (33.3 %). 3. The actual noise measurements of the headsets worn by the users of different sexes and educational backgrounds produced no differences(p>0.05), while a significant difference was found between genders (p<0.05). 4. For sound pressure level measurements, the weighted average(Lavg) of 84.5 dB(A) on the left headsets exceeded that of 79.8 dB(A) on the right headsets significantly(p<0.01) and the maximum value of 96.9 dB(A) on the left headsets exceeded the maximum value of 93.5 dB(A) on the right headsets(p<0.01). 5. The actual noise measurements of the headsets worn by the users of different sexes and educational backgrounds produced no differences(p>0.05), however, the contents selected by the users with different educational backgrounds were noted with significant difference(p<0.05) while no difference was found by gender(p>0.05).

미세 매연입자의 응집을 위한 초음파장의 적용 (Application of Ultrasonic for agglomeration of fine soot particles)

  • 정상현;홍원석;심성훈;김용진;이성범
    • 한국연소학회지
    • /
    • 제8권2호
    • /
    • pp.41-49
    • /
    • 2003
  • Ultrasonic field of 28kHz with sound pressure level 162dB has been employed to agglomerate the fine soot particle produces in a diffusion flame in a chamber. The agglomeration process has been investigated with digital camcorder and analysed in terms of the decrease of number density with exposure time. From the observation of agglomeration process, the initial agglomeration has been carried out during the short time, and it has been dominated by the orthokinetic collision. Thereafter, a slower agglomeration mechanism, driven by acoustic streaming in the chamber takes over and agglomeraters grew to diameters of several millimeters were levitated at the pressure node of the acoustic wave. And, the circular disk shape of large agglomeraters with the rotational and translational motion is observed.

  • PDF