Comparison of Effectiveness in Differentiating Benign from Malignant Ovarian Masses between IOTA Simple Rules and Subjective Sonographic Assessment

  • Tongsong, Theera;Tinnangwattana, Dangcheewan;Vichak-ururote, Linlada;Tontivuthikul, Paponrad;Charoenratana, Cholaros;Lerthiranwong, Thitikarn
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권9호
    • /
    • pp.4377-4380
    • /
    • 2016
  • Background: To compare diagnostic performance in differentiating benign from malignant ovarian masses between IOTA (the International Ovarian Tumor Analysis) simple rules and subjective sonographic assessment. Materials and Methods: Women scheduled for elective surgery because of ovarian masses were recruited into the study and underwent ultrasound examination within 24 hours of surgery to apply the IOTA simple rules by general gynecologists and to record video clips for subjective assessment by an experienced sonographer. The diagnostic performance of the IOTA rules and subjective assessment for differentiation between benign and malignant masses was compared. The gold standard diagnosis was pathological or operative findings. Results: A total of 150 ovarian masses were covered, comprising 105 (70%) benign and 45 (30%) malignant. Of them, the IOTA simple rules could be applied in 119 (79.3%) and were inconclusive in 31 (20.7%) whereas subjective assessment could be applied in all cases (100%). The sensitivity and the specificity of the IOTA simple rules and subjective assessment were not significantly different, 82.9% vs 86.7% and 94.0% vs 94.3% respectively. The agreement of the two methods in prediction was high with a Kappa index of 0.835. Conclusions: Both techniques had a high diagnostic performance in differentiation between benign and malignant ovarian masses but the IOTA rules had a relatively high rate of inconclusive results. The IOTA rules can be used as an effective screening technique by general gynecologists but when the results are inconclusive they should consult experienced sonographers.

The Difference of the Changes of Images on Ultrasound Scanner Setting Parameters

  • Kang, Hae-Kyung;Kim, Youn-Min;Kim, Hyun-Soo;Lee, Sung-Hee;Cho, Se-Youn;Lyu, Young-Eun;Jung, In-A
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.81-87
    • /
    • 2010
  • The setting parameters of ultrasound scanner give influences to change of image. Sonographers have used a Matlab program to make Low Contrast Sensitivity(LCS) value and compared original images in order to evaluate the use of the supersonic diagnosis machinery. We confirmed the change of image in Grayscale values using Photoshop program. Experiment equipment of our research used A Medison Accuvix V10, A Multi-Tissue Ultrasound Phantom(040 GSE) of CHRIS Company, A Adobe Photoshop CS4 Program, A Convex Probe, A USB memory stick, A Probe Fixation Equipment. The method used Gain, Dynamic Range(DR) of the setting parameters of ultrasound scanner and researched Gain and DR was set to 10 dB. We changed the different settings to see the changes of images using Grayscale values of a Photoshop program about tissue images of a phantom. This study evaluated DR and Gain whether it is an image controller to get the optimum contrast to produce an image to see the how effect on the images. We did not use Gateway in supersonic diagnosis machinery. We can easily open to open the files through Photoshop program before we get Digital Imaging and Communications in Medicine(DICOM) files use USB memory stick in supersonic diagnosis machinery. When we diagnosed the lesion of the patient with ultrasound, the contrast and the Gray scale value of image are very important. In this research, we determined the optimum setting parameters that provided useful information to diagnose disease and evaluated the change of improved images.

  • PDF

초음파검사에 대한 방사선사 업무범위의 법적 고찰 (A Scope of Work of Radiological Technologists for Ultrasound Examinations)

  • 임창선;진계환
    • 한국방사선학회논문지
    • /
    • 제15권4호
    • /
    • pp.481-490
    • /
    • 2021
  • 한국에 초음파사 자격제도는 없다. 그러나 「의료기사 등에 관한 법률」에 방사선사가 초음파 진단기를 취급할 수 있도록 규정하고 있다. 따라서 방사선사가 초음파검사를 시행하는데 허용되는 업무 범위와 한계에 대하여 논란이 있다. 이에 한국 보건복지부의 유권해석과 행정심판 재결, 법원의 판결을 분석해 보았다. 그 결과 유권해석에서는 방사선사가 초음파영상검사를 수행할 때 의사가 방사선사의 촬영영상을 동시에 보면서 실시간으로 진단과 구체적인 지도가 이루어질 수 있다면, 물리적으로 동일한 공간에 있어야 한다는 의미로서 입회 또는 기타 의료기술을 활용한 "의사의 실시간 지도하에 방사선사의 초음파검사 및 촬영"은 가능하며, 이 경우 의사의 지도는 방사선사와 1:1로 이루어져야만 한다'고 풀이하고 있다. 행정심판에서는 초음파 관련 장비의 취급은 방사선사의 업무라고 재결하였다. 법원에서는 의사의 구체적인 지휘·감독 없이 방사선사가 단독으로 초음파검사를 시행하고, 방사선사가 초음파검사에 대하여 의학적 판단을 하는 것은 위법이라고 판결하였다. 그러나 미국, 캐나다, 호주, 일본 등에서는 초음파사(sonographer, 超音波検査士)가 의사의 처방에 따라 독자적으로 환자에 대한 초음파검사를 하고, 그 결과에 대한 예비소견을 작성하여 의사에게 전달하고 있다. 따라서 한국에서도 미국 등과 같이 초음파검사를 시행하는 방사선사가 실시간 지도를 받지 않고 의사의 처방에 따라 초음파검사를 수행할 수 있도록 제도적 개선이 요구된다.

초음파 장비에 따른 정도관리와 화질 비교 (Quality Control and Image Quality Comparison according to Ultrasonic Equipment)

  • 홍동희
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.935-942
    • /
    • 2022
  • 초음파 유도 하 중재적 시술 시 먼저 초음파 장비로 병변의 위치를 파악하며 angio needle을 삽입한다. 이때 실제와 초음파 상 병변의 위치 또는 바늘의 투과 깊이의 차이가 클수록 인체의 주요 혈관이나 조직에 손상을 일으킬 수 있는 위험이 있다. 그러므로 우리는 초음파 장비 업체와 연식에 따라 성능의 차이가 나는지, 이것이 시술의 정확도에 얼마나 영향을 끼치는지 의문이 들어 이를 연구 주제로 삼았다. 본 연구에서는 임의의 초음파 5대의 장비를 사용하여 초음파상 주사침의 길이와 실제 길이를 비교하여 왜곡에 영향을 주는 요인을 분석하고자 하였다. 초음파 유도 하 돼지고기 투과 시 각 연식과 업체가 다른 다섯 대의 초음파 장비로 실제 소시지의 깊이와 바늘의 투과 길이를 영상에서의 값을 측정하여 오차율을 비교하기 위해 spss 22 통계 프로그램의 단일 표본 T 검정을 이용하였다. 그 결과 모두 통계적으로 유의한 범위의 수치가 나왔고, 장비의 연식과 업체만으로 성능을 평가하는 것은 옳지 않다고 판단하였다. 그러므로 초음파 정도 관리를 정기적으로 실시하고 시술자의 숙련도를 높여 실제 시술 부위와 영상에서의 오차율을 줄여야한다고 결론을 내리는 바이다.

초음파 진단기의 설정 파라미터가 영상의 질에 미치는 효과 (Effects of Ultrasonic Scanner Setting Parameters on the Quality of Ultrasonic Images)

  • 양정화;이경성;강관석;팽동국;최민주
    • 한국음향학회지
    • /
    • 제27권2호
    • /
    • pp.57-65
    • /
    • 2008
  • 초음파 진단기의 설정은 영상의 질에 영향을 준다. sonographer는 최적의 영상을 얻기 위해 초음파 영상의 질에 영향을 주는 설정 변수에 대한 효과를 이해해야 한다. 본 연구에서는 4가지 대표적인 영상 조절 변수 즉 TGC (Time Gain Control), 이득 (Gain), 주파수 (Frequency), DR (Dynamic Range)를 고려하였다. 초음파 영상의 질은 LCS (Law Contrast Sensitivity) 관점에서 정량적으로 비친 평가하였다. 실험은 임상용 초음파 진단기 (SA-9000 PRIME, Medison, Korea)를 사용하여 초음파 평가 팬텀 (539, ATS, USA)의 LCS 타겟을 영상화하였다. 영상 조절 변수의 설정을 변화하면서, 각 설정에 대한, 6개의 LCS 영상 (+15 dB, +C dB, +3 dB, -3 dB, -6 dB, -15 dB)을 취득하고, 영상에 대한 LCS픽셀 값을 계산하였다. 실험결과 TGC가 최대, Gain은 중간에서 최대사이, 주파수가 Pen모드, DR이 40-66 dB일 때 타겟 영상 (LCS)의 평균 픽셀 값이 높았다. 모든 타겟 영상에서 DR이 40 dB일 때에 LCS가 좋은 영상을 얻었다. 본 결과는 임상에서 잘 발견되는 solid lesion (+15, +6, +3 dB 타겟과 유사) 또는 cystic lesion (-15, -6, -3 dB 타겟과 비슷)이 있는 mass 평가 시 적절한 영상조절 변수 설정에 유용한 정보를 제공할 것으로 기대된다.