• Title/Summary/Keyword: Song Mode

Search Result 1,051, Processing Time 0.027 seconds

A Method to Accelerate Convergence of Hessenberg process for Small Signal Stability Analysis of Large Scale Power Systems (대규모 전력계통의 미소신호 안정도 해석을 위한 Hessenberg Process의 수렴특성 가속화 방법)

  • Song, Sung-Geun;Nam, Ha-Kon;Shim, Kwan-Shik;Moon, Chae-Ju;Kim, Yong-Gu
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.871-874
    • /
    • 1998
  • It is most important in small signal stability analysis of large scale power systems to compute only the dominant eigenvalues selectively with numerical stability and efficiency. Hessenberg process is numerically very stable and identifies the largest eigenvalues in magnitude. Hence, transformed system matrix must be used with the process. Inverse transformation with complex shift provides high selectivity centered on the shift, but does not possess the desired property of computing the dominant mode first. Thus, advantage of high selectivity of the transformation can be fully utilized only when the complex shift is given close to the dominant eigenvalues. In this paper, complex shift is determined by Fourier transforming the results of dynamic simulation with PTI's PSS/E transient simulation program. The convergence in Hessenberg process is accelerated using the iterative scheme. Overall, a numerically stable and very efficient small signal stability program is obtained. The stability and efficiency of the program has been validated against New England 10-machines 39-bus system and KEPCO system.

  • PDF

An Experimental Study on the Flame Dynamics in the Model Combustor with V-gutter type Flameholder (V-gutter 형 보염기가 장착된 모델 연소기 내에서 발생하는 화염 동특성 연구)

  • Song, Jin-Kwan;Jeong, Chan-Young;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.379-385
    • /
    • 2010
  • Mechanism of combustion frequencies occurring during combustion is experimentally investigated in a model combustor with V-gutter flameholder. The combustor has a long duct shape with a cross section area of $40{\times}40mm$. The v-gutter type flameholder with 10, 12, 14mm width is mounted at the side wall of combustor. CNG were used as fuel, and the fuel was injected transversely into air crossflow. It is found that combustion frequencies were considered as first longitudinal mode caused by combustor geometry. And it is found that flameholder length affects the flame holding range. Also, it is observed first longitudinal pressure oscillations make significant changes of flame structure.

  • PDF

Analysis of Damage Trend for Gas Turbine 1st Bucket Related to the Change of Models (모델 변천에 따른 가스터빈 1단 버켓의 손상경향 분석)

  • Kim, Moon-Young;Park, Sang-Yeol;Yang, Sung-Ho;Choi, Hee-Sook;Ko, Won;Song, Kuk-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.6 s.261
    • /
    • pp.718-724
    • /
    • 2007
  • Some of gas turbine model of 7F-Class has constructed and is operating with units domestically. Non-destructive testing (NDT) is one of the methods being used to inspect damage $1^{st}$ stage bucket and review damage trends. We also analyze damage configuration and microstructure according to material and compare with pape of electric power research institute (EPRI). The damaged mode could be determined by leveraging failure analysis. Especially, configuration uprate of bucket is not only to prevent damage during operation but also avoid domestic manufacturing by the competitors. Modifications were mainly concentrated on surfaces such as cooling hole and bucket tips. Analyzing of bucket damage, the earlier model of 7F-Class used with one cycle with equivalent operation hour (EOH), has various cracking of the bucket surface. Bucket damage of new model is centered on tip area (54%) as analyzed by EPRI research. We conclude that improving bucket configuration would increase repair rate on the bucket tip.

A Study on the Development Strategy of Tianjin Bonded Port in China (천진보세항구의 발전방안에 관한 연구)

  • HAN, Jia-Wei;SHIN, Han-Won;SONG, Xiao-Ming
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.6
    • /
    • pp.1706-1714
    • /
    • 2016
  • In the 21th century, with the development of the economic global progress, the competition is more stiff. During the fierce competition, 85% of the world's trade volume is root from the sea transportation, that means the harbor trade is becoming an important part in the world's trade. With the strong support of the Chinese national ministries, Tianjin Dongjiang Bonded Port Area had made a series of encouraging results and now becoming a positive mode of the chinese harbor trade port. In the meanwhile, the Dongjiang Bonded Port Area is also searching for the change and a better development. From this year, the Dongjiang Bonded Port Area is apply for the experimental unit to change from the Bonded Port Area to the Free Trade Zone. This paper focus on the Tianjin Dongjiang Bonded Port Area which is the largest port area in the northern part of China. The development progress of the Dongjiang Bonded Port Area is concerned and studied in the paper. This paper expected to research on the transformation progress from the Bonded Port Area to the Free Trade Zone, to find out appropriate ways for the blossom of the harbor trade and the bonded area.

AN OPTICAL FIBER FEED LITTROW-MOUNTED SPECTROMETER (광섬유 피드 리트로마운트형 분광계)

  • Bae, J.H.;Song, J.W.;Yoon, T.S.
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.3
    • /
    • pp.87-93
    • /
    • 2012
  • A low-dispersion fiber feed Littrow-mounted grating spectrometer for education was designed and fabricated. The dispersion element is a reflective type blazed grating Edmundoptics NT 46-075 (spatial frequency 600 lines/mm, dimension $30mm{\times}30mm$, blazed angle 8.6 degree). The optical fiber coupler module for optical guiding from telescope to spectrometer is composed of a multi-mode FC connector - FC connector optical fiber patch cord (core/cladding diameter $50{\mu}m/125{\mu}m$) and two 1.25" throw-tube couplers. The lens for collimating and imaging is a general purpose focal length 50 mm camera lens (f/1.8). The device for optical path control is a rectangular prism (size $25mm{\times}25mm$). The imaging camera sensor is a Meade DSI Pro 2 CCD sensor (black and white, $752{\times}582$ pixels and pixel size $8.3{\mu}m{\times}8.6{\mu}m$). Softwares for data logging and analysis consist of Meade Autostar Suite, NIH imagej and Vernier Logger Pro 3. The wavelength coverage range of the spectrometer is 205 nm at central wavelength 550 nm. The wavelength resolution is 1.7 nm.

THE SHEAR BOND STRENGTH OF RESIN TEETH TO THE DENTURE BASE RESIN (레진치와 의치상 레진간의 전단 결합강도에 관한 연구)

  • Song, Young-Kuk;Jung, Young-Wan;Jin, Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.235-241
    • /
    • 1999
  • The bond failure of resin teeth In denture base resin is one of the failure in prosthodontic treatment. The purpose of this study was to evaluate the bond strength of artificial resin teeth to the denture base resins. Specimens were made with heat curing acrylic resins (Vertex Rs, Lucitone 199) and artificial resin teeth (Tiger, Trubyte biotone, Endura, Orthosit, Tubyte bioform IPN) and the bond strength were measured with testing machine(Zwick. Germany) and the mode of bond failure were observed. The results were as follows; 1. The bond strength of Vertex Rs to artificial resin teeth was the highest in Tubyte biotone, and It was the lowest in Tiger and Trubyte bioform IPN. 2. The bond strength of Lucitone 199 to artificial resin teeth were higher in Orthosit and Trubyte bioform IPN than in Tiger and Trubyte biotone. 3. The bond strength of Trubyte biotone to Vertex Rs was higher than to Lucitone 199 and that of the Trubyte bioform IPN to Lucitone 199 was higher than to Vertex Rs. 4. Nearly all bond failures of specimens occured cohesively within the resin teeth.

  • PDF

A study on the accelerated life test model for life prediction of piston assemblies (피스톤 조립체의 수명예측을 위한 가속실험모델에 관한연구)

  • Lee, Yong-Bum;Kim, Hyoung-Eui;Song, Kyu-Joe;Kim, Tae-Suk
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2006.05a
    • /
    • pp.116-125
    • /
    • 2006
  • Piston assemblies, which are key components of hydraulic high pressure pumps & motors, are major failure products operating at high pressure and high speed, and the main failure mode is wearout of the shoe surface. To predict the actual life of piston assemblies. we require to find out the most sensitive parameters and establish related empirical formula. In this study, we analyzed the life of piston and shoe assemblies in accordance with variation of speed, pressure, and temperature to reduce the life test time, then analyzed the result of combined accelerated life test which is applied by high speed, speed pressure, and high temperature simultaneously, and finally developed combined accelerated life test model.

  • PDF

EXPERIMENTAL INVESTIGATIONS ON HEAT TRANSFER TO CO2 FLOWING UPWARD IN A NARROW ANNULUS AT SUPERCRITICAL PRESSURES

  • Kim, Hwan-Yeol;Kim, Hyung-Rae;Kang, Deog-Ji;Song, Jin-Ho;Bae, Yoon-Yeong
    • Nuclear Engineering and Technology
    • /
    • v.40 no.2
    • /
    • pp.155-162
    • /
    • 2008
  • Heat transfer experiments in an annulus passage were performed using SPHINX(Supercritical Pressure Heat Transfer Investigation for NeXt Generation), which was constructed at KAERI(Korea Atomic Energy Research Institute), to investigate the heat transfer behaviors of supercritical $CO_{2}$. $CO_{2}$ was selected as the working fluid to utilize its low critical pressure and temperature when compared with water. The mass flux was in the range of 400 to 1200 $kg/m^{2}s$ and the heat flux was chosen at rates up to 150 $kW/m^{2}$. The selected pressures were 7.75 and 8.12 MPa. At lower mass fluxes, heat transfer deterioration occurs if the heat flux increases beyond a certain value. Comparison with the tube test results showed that the degree of heat transfer deterioration in the heat flux was smaller than that in the tube. In addition, the Nusselt number correlation for a normal heat transfer mode is presented.

Current-induced Phase Demodulation Using a PWM Sampling for a Fiber-optic CT

  • Park, Hyoung-Jun;Lee, June-Ho;Kim, Hyun-Jin;Song, Min-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.240-244
    • /
    • 2010
  • In this work, we used PWM sampling for demodulation of a fiber-optic interferometric current transformer. The interference signal from a fiber-optic CT is sampled with PWM triggers that produce a 90-degree phase difference between two consecutively sampled signals. The current-induced phase is extracted by applying an arctangent demodulation and a phase unwrapping algorithm to the sampled signals. From experiments using the proposed demodulation, we obtained phase measurement accuracy and a linearity error, in AC current measurements, of ~2.35 mrad and 0.18%, respectively. The accuracy of the proposed method was compared with that of a lock-in amplifier demodulation, which showed only 0.36% difference. To compare the birefringence effects of different fiber-optic sensor coils, a flint glass fiber and a standard single-mode fiber were used under the same conditions. The flint glass fiber coil with a Faraday rotator mirror showed the best performance. Because of the simple hardware structure and signal processing, the proposed demodulation would be suitable for low-cost over-current monitoring in high voltage power systems.

An Experimental Study on the Performance Characteristics of a Single-Circuit Multi Cycle and a Bypass Two-Circuit Multi Cycle (단일유로 멀티사이클 및 바이패스유로 멀티사이클 적용 냉동시스템의 성능특성에 관한 실험적 연구)

  • Song, Young-Seung;Jung, Hae-Won;Yoon, Won-Jae;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.7
    • /
    • pp.513-519
    • /
    • 2011
  • The object of this study is to investigate the performance characteristics of refrigerators using a single-circuit multi cycle and a bypass two-circuit multi cycle. Each refrigeration cycle was tested by varying secondary fluid mass flow rate and temperature. Based on the experimental data, the optimum refrigerant charge was 48 g and the COP at the optimum secondary fluid mass flow rate was 1.53 for the single-circuit multi cycle. For freezer(F)-only mode, both the single-circuit multi cycle and the bypass two-circuit multi cycle were operated at overcharge conditions, resulting in an increase of the secondary fluid mass flow rate. The maximum COPs of the single-circuit multi cycle and the bypass two-circuit multi cycle were 1.22 and 1.35, respectively. The COP increased by 10.7% with the application of the bypass two-circuit multi cycle.