• Title/Summary/Keyword: Solution Plasma

Search Result 736, Processing Time 0.027 seconds

Control of surface defects on plasma-MIG hybrid welds in cryogenic aluminum alloys

  • Lee, Hee-Keun;Chun, Kwang-San;Park, Sang-Hyeon;Kang, Chung-Yun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.7 no.4
    • /
    • pp.770-783
    • /
    • 2015
  • Lately, high production rate welding processes for Al alloys, which are used as LNG FPSO cargo containment system material, have been developed to overcome the limit of installation and high rework rates. In particular, plasma-metal inert gas (MIG) hybrid (PMH) welding can be used to obtain a higher deposition rate and lower porosity, while facilitating a cleaning effect by preheating and post heating the wire and the base metal. However, an asymmetric undercut and a black-colored deposit are created on the surface of PMH weld in Al alloys. For controlling the surface defect formation, the wire feeding speed and nozzle diameter in the PMH weld was investigated through arc phenomena with high-speed imaging and metallurgical analysis.

The Study of Improvement in the Characteristics of Oxide Thin Film Transistor by using Atmospheric Pressure Plasma (대기압 플라즈마를 이용한 산화물 박막 트랜지스터 표면처리에 관한 연구)

  • Kim, Ga Young;Kim, Kyong Nam;Yeom, Geun Young
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.1
    • /
    • pp.7-10
    • /
    • 2015
  • Recently, oxide TFTs has attracted a lot of interests due to their outstanding properties such as excellent environmental stability, high mobility, wide-band gap energy and high transparency, and investigated through the method using vacuum system and wet solution. In the case of the method using wet solution, process is very simple, however, annealing process should be included. In this study, to overcome the problem of annealing process, atmospheric pressure plasma was used for annealing, and the electrical characteristics such as on/off ration and mobility of device were investigated.

Analysis of $Si_3N_4$ Ultra Fine Powder Using High-pressure Acid Digestion and Slurry Injection in Inductively Coupled Plasma Atomic Emission Spectrometry

  • Kim, K.H.;Kim, H.Y.;Im, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.2
    • /
    • pp.159-163
    • /
    • 2001
  • Si3N4 powder has been analyzed by inductively coupled plasma atomic emission spectrometry (ICP-AES). The sample was dissolved by high-pressure acid digestion with HF, H2SO4 (1+1), and HNO3 mix ture. This technique is well suited for the impurity analysis of Si3N4 because the matrix interference is eliminated. A round-robin samples trace elements, such as Ca, W, Co, Al, Fe, Mg, and Na, were determined. For the direct analysis, slurry nebulization of 0.96 mm Si3N4 powder also has been studied by ICP-AES. Emission intensities of Fe were measured as ICP operational conditions were changed. Significant signal difference between slurry particles and aqueous solution was observed in the present experiment. Analytical results of slurry injection and high-pressure acid digestion were compared. For the use of aqueous standard solution for calibration, k-factor was determined to be 1.71 for further application.

Determination of Bi Impurity in Lead Stock Standard Solutions by Hydride-generation Inductively Coupled Plasma Mass Spectrometry

  • Park, Chang J.
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.2
    • /
    • pp.233-236
    • /
    • 2004
  • Total impurity analysis of a primary standard solution is one of the essential procedures to determine an accurate concentration of the standard solution by the gravimetry. Bi impurity is determined in Pb standard solutions by inductively coupled plasma mass spectrometry (ICP-MS). The direct nebulization of the Pb standard solution produces a significant amount of the Pb matrix-induced molecular ions which give rise to a serious spectral interference to the Bi determination. In order to avoid the spectral interference from the interferent $^{208}PbH^+$, the hydride generation method is employed for the matrix separation. The Bi hydride vapor is generated by reaction of the sample solution with 1% sodium borohydride solution. The vapor is then directed by argon carrier gas into the ICP after separation from the mixture solution in a liquid-gas separator made of a polytetrafluoroethylene membrane tube. The presence of 1000 ${\mu}$g/mL Pb matrix caused reduction of the bismuthine generation efficiency by about 40%. The standard addition method is used to overcome the chemical interference from the Pb matrix. Optimum conditions are investigated for the hydride-generation ICPMS. The detection limit of this method is 0.5 pg/mL for the sample solutions containing 1000 ${\mu}$g/mL Pb matrix.

수처리 목적의 대기압플라즈마를 이용한 유사 폴리도파민 필름 증착

  • Mun, Mu-Gyeom;Yeom, Geun-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.124-124
    • /
    • 2018
  • Polydopamine은 수중 접착력, 친환경 접착제, nanoparticle absorption 등 다양한 특성으로 많이 연구되고 있는 소재이다. 본 연구에서는 dopamine을 이용하여 수중 금속을 흡착시키는 thin film을 제작하였다. 종래의 Polydopamine coating 방법으로 wet coating 이 사용되고 있다. 하지만 wet 방식의 경우 시간이 오래 걸릴 뿐만 아니라 in-line, roll to roll 방식을 적용하는 것이 어렵기 때문에 생산적이지 않다. 이에 본 연구에서는 Atmospheric Pressure Plasma(APP)를 이용 하여 Polydopamine-like film을 coating 하였다. APP의 경우 vacuum system, solution tank가 필요 없고 in-line, roll to roll 방식을 적용 할 수 있기 때문에 더 경제적이고 생산적인 공정이다. 또한 기존의 Plasma polymerization 방법은 Plasma energy가 높기 때문에 source의 분자구조가 바뀌거나 atom 단위로 분해된다. source의 분자구조가 바뀌는 "Atomic polymerization", Neiswender-Rosskamp Mechanism이 적용되면 wet 방식 coating한 film과는 다른 특성을 갖게 된다. 하지만 APP polymerization은 Plasma energy가 vacuum plasma 보다 매우 낮기 때문에 stile polymerization mechanism을 구현 하는데 적합 하다. stile polymerization mechanism은 Plasma 내부에서 polymer source를 분해 성장 시켜서 Polymer film 얻는 것이 아닌 source의 분자구조가 깨지지 않으면서 polymer growing 시키는 방법이다. dopamine source의 분자구조를 최대한 유지하려고 하는 이유는 metal absorption과 같은 특성이 dopamine chemical structure에 영향을 받기 때문이다. 많은 논문들에서 dopamine의 catechol group이 metal absorption, adhesion force에 영향을 주는 주요 인자라고 주장하고 있기 때문이다. 그래서 본 논문에서는 Dopamine source의 형태를 보존하면서 Polymerization 하는 방법으로 APP process를 사용 하여 낮은 전압에서 Polydopamine-like film을 제작 하였다. APP system 의 Plasma 방전부 에 Dopamine source를 유입하기 위하여 본 논문에서는 Piezo Spray 방식을 사용 하였다. Dopamine을 evaporator 하는 것이 어렵고 chemical composition이 유사한 monomer를 사용해서 Plasma Polymerization으로 Dopamine 분자 구조를 재현하는 것도 어렵다. 그래서 본 연구에서는 Dopamine을 water에 immerse 하고 Dopamine solution을 mist 상태로 만들어서 Plasma discharge area에 유입하였다. 이러한 방법으로 만들어진 film은 Polydopamine film은 아니지만 Polydopamine film과 유사한 Chemical composition, chemical structure, metal absorption을 갖는 것을 FT-IR, SEM, XPS을 이용 하여 확인 하였다. Dopamine source의 보존에 대하여 명확하게 확인하기 위하여 FT-IR을 측정 하였다. 전압에 따른 Benzene ring, hydroxyl group의 비율을 확인 하였다. 낮은 전압으로 coating 된 Polydopamine-like film 일수록 hydroxyl group peak($3400{\sim}3000cm^{-1}$)과 비교하여 Benzene ring peak($1600{\sim}1580cm^{-1}$ and $1510{\sim}500cm^{-1}$)이 흡수를 더 많이 하는 것을 확인 할 수 있다. 이것은 Benzene ring이 파괴되지 않고 보존되는 것을 보여준다. Dopamine에서 Benzene ring은 absorption main factor인 catechol에 있는 chemical structure이다. 즉 Benzene ring peak이 높을수록 Catechol이 잘 보존 되었다는 의미 이다. Catechol의 보존은 absorption main factor가 보존 된다는 의미 이다. 이러한 Polydopamine-like film으로 As, Cr, Mg, Cu 200ppm solution에 대한 filtration 능력을 확인 하였다. As, Cr, Cu, Mg 의 제거율이 각각 약25%, 35%, 45%, 65%인 것을 확인 하였다. 이 수치는 시중에 판매되는 제품들과 비교했을 때 300%~500% 향상된 수치 이다.

  • PDF

Solution Plasma Synthesis of BNC Nanocarbon for Oxygen Reduction Reaction

  • Lee, Seung-Hyo
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.5
    • /
    • pp.332-336
    • /
    • 2018
  • Alkaline oxygen electrocatalysis, targeting anion exchange membrane alkaline-based metal-air batteries has become a subject of intensive investigation because of its advantages compared to its acidic counterparts in reaction kinetics and materials stability. However, significant breakthroughs in the design and synthesis of efficient oxygen reduction catalysts from earth-abundant elements instead of precious metals in alkaline media still remain in high demand. One of the most inexpensive alternatives is carbonaceous materials, which have attracted extensive attention either as catalyst supports or as metal-free cathode catalysts for oxygen reduction. Also, carbon composite materials have been recognized as the most promising because of their reasonable balance between catalytic activity, durability, and cost. In particular, heteroatom (e.g., N, B, S or P) doping on carbon materials can tune the electronic and geometric properties of carbon, providing more active sites and enhancing the interaction between carbon structure and active sites. Here, we focused on boron and nitrogen doped nanocarbon composit (BNC nanocarbon) catalysts synthesized by a solution plasma process using the simple precursor of pyridine and boric acid without further annealing process. Additionally, guidance for rational design and synthesis of alkaline ORR catalysts with improved activity is also presented.

Effect of AZ31 PEO Coating Layer Formation According to Alginic Acid Concentration in Electrolyte Solution

  • Kim, Min Soo;Kim, Jong Seop;Park, Su Jeong;Koo, Bon Heun
    • Korean Journal of Materials Research
    • /
    • v.32 no.6
    • /
    • pp.301-306
    • /
    • 2022
  • This study explored the possibility of forming a coating layer containing alginic acid on the surface of a magnesium alloy to be used as a biomaterial. We formed a coating layer on the surface of a magnesium alloy using a plasma electrolytic oxidation process in an electrolytic solution with different amounts of alginic acid (0 g/L ~ 8 g/L). The surface morphology of all samples was observed, and craters and nodules typical of the PEO process were formed. The cross-sectional shape of the samples confirmed that the thickness of the coating layer became thicker as the alginic acid concentration increased. It was confirmed that the thickness and hardness of the sample significantly increase with increasing alginic acid concentration. The porosity of the surface and cross section tended to decrease as the alginic acid concentration increased. The XRD patterns of all samples revealed the formation of MgO, Mg2SiO4, and MgF2 complex phases. Polarization tests were conducted in a Stimulate Body Fluid solution similar to the body's plasma. We found that a high amount of alginic acid concentration in the electrolyte improved the degree of corrosion resistance of the coating layer.

Optical Properties of Spherical YAG:Ce3+ Phosphor Powders Synthesized by Atmospheric Plasma Spraying Method Appling PVA Solution Route and Domestic Aluminium Oxide Seed (PVA 용액법과 국산 산화알루미늄을 적용하여 대기 플라즈마 용사법으로 합성된 구형의 YAG:Ce3+ 형광체의 발광특성)

  • Yong-Hyeon Kim;Sang-Jin Lee
    • Journal of Powder Materials
    • /
    • v.30 no.5
    • /
    • pp.424-430
    • /
    • 2023
  • YAG phosphor powders were fabricated by the atmospheric plasma spraying method with the spray-dried spherical YAG precursor. The YAG precursor slurry for the spray drying process was prepared by the PVA solution chemical processing utilizing a domestic easy-sintered aluminum oxide (Al2O3) powder as a seed. The homogenous and viscous slurry resulted in dense granules, not hollow or porous particles. The synthesized phosphor powders demonstrated a stable YAG phase, and excellent fluorescence properties of approximately 115% compared with commercial YAG:Ce3+ powder. The microstructure of the phosphor powder had a perfect spherical shape and an average particle size of approx imately 30 ㎛. As a result of the PKG test of the YAG phosphor powder, the synthesized phosphor powders exhibited an outstanding luminous intensity, and a peak wavelength was observed at 531 nm.

HPLC Assay and Renal Excretion Characteristics of Theophylline and Its Metabolites in Rat (테오필린과 그 대사체의 HPLC 동시 정량 및 신(腎) 배설 특성)

  • Kuh, Hyo-Jeong;Shim, Chang-Koo;Lee, Min-Hwa;Kim, Shin-Keun
    • Journal of Pharmaceutical Investigation
    • /
    • v.21 no.1
    • /
    • pp.33-41
    • /
    • 1991
  • A high-performance liquid chromatographic (HPLC) method was developed for the simultaneous determination of theophylline(TP) and its metabolites, 1-methyluric acid (1-MU) and 1,3-dimethyluric acid (1,3-DMU), in rat plasma and urine. An $100\;{\mu}l$ aliquot of a plasma or urine sample was mixed with $250\;{\mu}l$ of acetonitrite and vortexed. After centrifugation, $200\;{\mu}l$ (plasma) or $20\;{\mu}l$ (urine) aliquot of the supernatant was dried by $N_2$ stream and redissolved in $100\;{\mu}l$ (plasma) or $200\;{\mu}l$ (urine) of the mobile phase. A $20\;{\mu}l$ of the mobile phase solution was injected onto a $C_{18}$ reversed-phase column. The column was maintained at $45^{\circ}C$ by the aid of electric heating jacket. The mobile phase was a 3%(v/v) methanol solution in deionized water which contains sodium acetate (100 mM) and tetrabutyl ammonium hydroxide (4 mM). pH of the mobile phase was adjusted 4.5 by the addition of acetic acid. Detection limits for TP, 1-MU, and 1,3-DMU in plasma were 0.2, 0.1 and $0.1\;{\mu}/ml$, respectively and the corresponding values in urine were all $5\;{\mu}g/ml$. Inter- and intra-day variability of the assay for all compounds in the plasma samples was less than 5.5 and 3.8%, respectively. The retention times for 1-MU, 1,3-DMU, and TP were approximately 7, 8.5 and 18 min, respectively. Sample preparation procedure used in this method was simple, rapid and reproducible. Renal clearance of TP and its metabolites in rats showed plasma concentration dependency indicating renal tubular secretion and reabsorption of them.

  • PDF

Bioavailability of Tripotassium Dicitrato Bismuthate by ICP-MS in Human Volunteers (ICP-MS를 사용한 구연산비스마스칼륨 (Tripotassium dicitrato bismuthate)의 생체이용률 측정)

  • Kwon, Oh-Seung;Kwon, Jee-Young;Yoon, Ae-Rin;Park, Kyung-Soo
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.2
    • /
    • pp.79-84
    • /
    • 2007
  • This study was aimed to establish analytical method of Bi to develop a guideline of the bioequivalence test of tripotassium dicitrato bismuthate (TDB). For this purpose, a simple, specific and sensitive inductively coupled plasma-mass spectrometry (ICP/MS) method were developed and validated in human plasma. Various concentrations of bismuth standard solution (0-25ng/mL) were prepared with distilled water and human blank plasma. To 10mL of the volumetric flasks, 2mL of blank plasma was added with 8ml of distilled water. Bi standard solution was added to prepare the calibration samples and injected into ICP-MS. The plasma samples obtained from volunteers given 3 tablets of bismuth (total 900mg as TDB) were analyzed as described above. As a result, the coefficients of variation were <20% in quantitation limit (0.2 ng/mL) and <15% at the rest of concentrations. The stability test by repeated freezing-thawing cycles showed that the samples were stable only for 24hr. The stability tested for samples with a short-term period of storage at room temperature and pre-treatment prior to the analysis showed very stable over 24hr. In 8 healthy Korean subjects received Denol tablets at the dose of 900mg bismuth, AUC, $C_{max},\;T_{max}$ and half-life $(t_{1/2})$ were determined to be $198.33{\pm}173.78 ng{\cdot}hr/mL,\;64.48{\pm}27.06 ng/mL,\;0.52{\pm}0.21 hr,\;and\;5.15{\pm}2.67 hr$, respectively, from the plasma bismuth concentration-time curves. In conclusion, the method was suitable for the determination of bismuth in human plasma samples and could be applied to bioequivalence test of bismuth tablet.