• 제목/요약/키워드: Solid-state nuclear track detectors (SSNTDs)

검색결과 3건 처리시간 0.017초

스크린도어 설치 후 서울지하철역 라돈 농도의 변화 특성 (A Noticeable Change in Indoor Radon Levels After Platform Screen Doors Installation in Seoul Subway Station)

  • 전재식;윤종철;이호찬;엄석원;채영주
    • 한국대기환경학회지
    • /
    • 제28권1호
    • /
    • pp.59-67
    • /
    • 2012
  • Platform screen doors (PSD) installed at 289 stations in Seoul metropolitan subway from November 2005 to December 2009, are expected to prevent death from a fall and improve air quality. In this study, we systematically surveyed changes in radon concentrations before and after PSD installation in Seoul metropolitan subway stations. By solid-state nuclear track detectors (SSNTD), the radon concentrations before and after the PSD installation were measured at 54 stations of 6 lines from 2 to 7 reported to have relatively high radon concentrations. Mean radon concentrations at platforms were decreased by approximately 56% from 121.7 Bq/$m^3$ to 54.0 Bq/$m^3$. Before PSD installation, mean radon concentrations were in the decreasing order for subway lines 7, 5, 6, 3, 4 and 2. On the other hand, after PSD installation the order was changed to 5, 6, 7, 3, 4 and 2. According to a radon map of Seoul metropolitan subway, the number of platforms where radon concentration over was 74 Bq/$m^3$ decreased from 38 to 12 after PSD installation.

Characterization of saturation of CR-39 detector at high alpha-particle fluence

  • Ghazaly, M. El;Hassan, Nabil M.
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.432-438
    • /
    • 2018
  • The occurrence of saturation in the CR-39 detector reduces and limits its detection dynamic range; nevertheless, this range could be extended using spectroscopic techniques and by measuring the net bulk rate of the saturated CR-39 detector surface. CR-39 detectors were irradiated by 1.5 MeV high alpha-particle fluence varying from $0.06{\times}10^8$ to $7.36{\times}10^8\;alphas/cm^2$ from Am-241 source; thereafter, they were etched in a 6.25N NaOH solution at a temperature of $70^{\circ}C$ for different durations. Net bulk etch rate measurement of the 1.5 MeV alpha-irradiated CR-39 detector surface revealed that rate increases with increasing etching time and reaches its maximum value at the end of the alpha-particle range. It is also correlated with the alpha-particle fluence. The measurements of UV-Visible (UV-Vis) absorbance at 500 and 600 nm reveal that the absorbance is linearly correlated with the fluence of alpha particles at the etching times of 2 and 4 hour. For extended etching times of 6, 10, and 14.5 hour, the absorbance is saturated for fluence values of $4.05{\times}10^8$, $5.30{\times}10^8$, and $7.36{\times}10^8\;alphas/cm^2$. These new methods pave the way to extend the dynamic range of polymer-based solid state nuclear track detectors (SSNTDs) in measurement of high fluence of heavy ions as well as in radiation dosimetry.

제주지역 일부 농업 시설 내 라돈 농도 예비 조사 (A Preliminary Investigation of Radon Concentration for Some Agricultural Greenhouses in Jeju Island)

  • 강태우;송명한;김태형;장병욱;김용재;김근호;박재우
    • 한국환경농학회지
    • /
    • 제31권1호
    • /
    • pp.9-15
    • /
    • 2012
  • 본 연구는 제주지역에서 온실 내 냉난방 및 $CO_2$ 공급 목적으로 지하공기를 이용하는 14개 농업 시설을 대상으로 약 3개월 동안 지하공기 이용 온실과 미이용 공간 내 라돈 농도 및 지하공기 이용 시설의 가동에 따른 지하공기 유입구 내 라돈 농도 분포를 조사하였다. 장기간 라돈 농도는 수동형 알파 입자비적 검출기(Raduet, Radosys Ltd., Hungary)로, 실시간 라돈 농도는 능동형 연속측정 검출기(RAD7, Durridge Co., USA)를 이용하여 측정하였다. 지하공기 이용 온실 내 라돈 농도는 지하공기 미이용 공간과 국내 가옥의 실내 평균값보다 높은 범위였으며, 대부분 농업 시설에서는 국제방사선 방호위원회에서 권고한 근무지에서의 참조준위 1,000 Bq/$m^3$ 보다 낮은 반면 한 개 지점에서는 높은 결과를 보였다. 장기간 및 실시간 지하공기 이용 시설의 가동에 따른 유입구의 라돈 농도 분포는 각각 1,228~5,259 및 3,322~17,900 Bq/$m^3$ 범위로 지역적인 차이를 보였다. 본 연구 결과, 지하공기 중 라돈 농도는 농업 시설이 위치한 지역의 지질 특성 및 시추공 깊이와 밀접한 관계가 있을 것으로 판단된다.